Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹2.0 Cr | L1 | Accepted-AOC being lowest |
| 2 | L2₹2.0 Cr+₹2.3 L (1.14%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | ₹2.0 Cr+₹2.3 L (1.14%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹2.3 Cr+₹35.2 L (17.6%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹2.3 Cr+₹35.2 L (17.6%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹2.4 Cr+₹42.8 L (21.5%)Rejected-Finance | ₹2.4 Cr+₹42.8 L (21.5%) | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹2.4 Cr
EMD Value
₹3.2 L
Closing Date
26 May 2025, 6:00 pmClosed
CE SHILLONG ZONE
HQ CE SHILLONG ZONE, SPREAD EAGLE FALLS, MES COMPLEX, SHILLONG, MEGHALAYA 793011
RELOCATION OF UTILITY SERVICES DUE TO TRANSFER OF DEFENCE LAND TO NHIDCL UNDER GE SHILLONG
2025_MES_704884_1
89675/SHL
Open Tender
Civil Works
Item Rate
270 days
SHILLONG
ALL AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹2,000
GE SHILLONG
₹3.2 L
Yes
28 Jul 2025
21 Apr 2025
28 May 2025
21 Apr 2025
26 May 2025
13 May 2025
Amount
NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' BOQ
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for laying of cables, pipe lines, etc; or for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out in soft/loose soil.
Excavation in trenches not exceeding 1.50 m wide and exceeding 1.5 meter depth but not exceeding 3.0 m depth for laying of cables, pipe lines, etc; or for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and exceeding 1.50 m depth but not exc 3.0m depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point complete all as specified and as directed.
Supply & Fix Steel Tubular Swaged Poles Type 410-SP-22 (8.5 Metre long) complete with cast iron base plate, finial taper plug, cap, mild steel bolts, nuts and screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of PCC coping) including writting MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified including dismantling of old unserviceable pole. Note: (a) Earthwork and PCC will be measured and paid separately (b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC.
Supply & Fix Steel Tubular Swaged Poles Type 410-SP-55 (11 Metre long) complete with cast iron base plate, finial taper plug, cap, mild steel bolts,nuts and screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of PCC coping) including writting MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified including dismantling of old unserviceable pole. Note: (a) Earthwork and PCC will be measured and paid separately (b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC.
Supply and fix HT 11 KV, 150 mm height and 150 mm dia pin type insulator, polymer, vitreous, white/brown/green, conforming to IS-2486 for 11000 Volts grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut complete all as specified and directed.
Supply and fixing factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated made of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed.
M & L for Stay assembly using 20 mm stay rod complete with accessories as shown in electrical plate No 1 including loop type insulator, (stay clamps, excavation and concrete will be measured and paid seperately )complete all as specified and directed.
Dismantling and removing existing OH lines ACSR conductors of any size/ type from poles / two/ three/four pole structures etc., removing and including two/three/four pole structures taken as credit complete all as specified and directed.
Dismantling cross arms of MS channels or angle sections, clamps etc., complete and removing from site complete.
Dismantling insulators, any type , any size and removing from site.
Supply and fixing cable joining kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed including taking down/up old unserviceable one.
Supply and fixing cable joining kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed including taking down/up old unserviceable one.
Supply and fixing Cable joining kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm including taking down/up old unserviceable one.
M & L for XLPE insulated , screened, PVC bedded , galvanised steel strip or wire armoured, electric power cables( Heavy Duty) with aluminium conductor , 11000 volts , grade cross sectional area 120 Sq mm, 3core complete all as specified and as directed including taking down/up old unserviceable one. Note: Excavation and earthwork shall be measured and paid separately.
Supply,installation,testing & commissioning of 11 KV Outdoor type (IP54) Ring Main Unit, consisting of with 2 nos manual Vacuum Circuit Breaker as INCOMER, 3 nos manual Vacuum Circuit Breaker as OUTGOINGS and One load breaker switch to use for Buscoupler with Raiser arrangement. All live parts, bus bars,LBS & VCBs, ON-OFF offload switch, Earth switch of feeder should be enclosed inside gas tank sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP65 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200.RMU Gas Tank and cable chamber should be tested for an internal arc fault of 21kA for 1 sec with AFLR classification. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown.The Gas Insulated switchgear should be complete with all accessories such as Terminal kits suitable for 1Cx300sqmm Cable, VPIS, cable supports, all front cable terminations, mechanical indications for VCB, OFF load switch & Earth switch , Manometer as per with IEC standards 62271-1, 100, 200. Altitude of installation up to 1000m. The unit shall include the following with all necessary standard fitting required at site.License partnar / Authorized Integrators are not accepted.
Sr. Item No. 17 (Contd/...) VACUM CIRCUIT BREAKER feeder 630A VCB module for making & breaking of fault current alongwith Earth Swicth of full making capacity-2 Nos for INCOMER & 3 Nos for OUTGOINGS Manual operated 630 A Vacuum circuit breaker having spring stored mechanism. ON-OFF off load switch and earthing switch downstream vacuum circuit-breaker. Menometer per tank. “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec Making Capacity - 52.5KA VCB must confirm operating sequence O-0.3sec-CO-3Min-CO and 2000 mechanical operation. Power frequency withstand voltage - 28KV & Impulse withstand voltage - 75KV Front cover mechanism - IP2X. Green(ON)/Red(OFF) push buttons to operate VCB. Indication Lamp for ON, OFF, TCS, TRIP, SPRING CHARGE etc. Self powered numerical protection relay having Over Current, erath fault with Modbus protocol over RS485. Resin cast ring core CT on cables 200-100/1A, Class:5P10 , 2.5 VA - 3 Nos Mechanical ON/OFF/EARTH/Spring charge Indication Cable boxes should be Arc Proof interlocked with respective Earthing Switches. RMU, VCB, Vaccum Interrupter must be of same make.
Sr. Item No. 17 (Contd/...) LOAD BREAK SWITCH as Buscoupler cum Raiser 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity-1 Nos. Manual operated 630 A Load Break Switch having snap action mechanism. Short time current - 21kA/ 3 sec Power frequency withstand voltage - 28KV Impulse withstand voltage - 75KV Front cover mechanism - IP2X Mechanical ON/OFF/EARTH Indication
M&L for sand cushioning with clean river sand ,including spreading ,levelling and punning down for protection of cables complete all as specified and as directed. Note: Thickness after punning down shall be measured
Supplying and laying un-reinforced precast concrete cable cover. class LV, Type 1,flat, size 250 mm x 150mm x 40mm conforming to IS 5820-1970 complete all as specified and as directed
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mm x 180`mm x 40mm conforming to IS:5820-1970 complete all as specified and as directed
Supply and lay in trenches, floors or fix on wall/pole or passing through pipes etc., LT UG cable(heavy duty), 1100 volts grade, XLPE insulated, with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs etc, of size 185 Sq.mm 3.5 core , conforming to IS 7098(Part-I-1988) including taking down/up old unservicable one.
Supply and lay in trenches, floors or fix on wall/pole or passing through pipes etc., LT UG cable(heavy duty), 1100 volts grade, XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs etc, of size 120 Sq.mm 3.5 core, conforming to IS 7098(Part-I-1988) including taking down/up old unservicable one.
Supply and lay in trenches, floors or fix on wall/pole or passing through pipes etc., LT UG cable(heavy duty), 1100 volts grade, XLPE insulated, with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs etc, of size 95 Sq.mm 3.5 core, conforming to IS 7098(Part-I-1988) including taking down/up old unservicable one.
Supply and lay in trenches, floors or fix on wall/pole or passing through pipes etc., LT UG cable(heavy duty) , 1100 volts grade, XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs etc, of size 25 Sq.mm 4 core , conforming to IS 7098(Part-I-1988) including taking down/up old unservicable one.
Supply and lay in trenches, floors or fix on wall/pole or passing through pipes etc., LT UG cable(heavy duty) , 1100 volts grade, XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs etc, of size 16 Sq.mm 4 core, conforming to IS 7098(Part-I-1988) including taking down/up old unservicable one. Note for item No 21 to 25 :- Excavation and earth work shall be measured and paid separately.
M & L for shifting of high mast light any size and height including disconnecting of light fitting complete with CI base plate and finial including excavation, coping, PCC work in foundation complete and including disconnecting light fittings, timer board , panel board , nut bolts etc and re-fixing in new location complete all as specified and as directed. Note:(i) T&P for shifting & wiring are deemed to be inclusive in the quoted rate (ii) Earth work and PCC will be measured and paid separetly.
M & L for shifting of LT Panel board any size including foundation, coping , excavation and PCC work complete including disconnecting the connections etc and re-fixing in new location and reconnecting the connections complete all as specified and as directed. (i) T&P for shifting & wiring are deemed to be inclusive in the quoted rate. (ii) Earthwork and PCC will be measured and paid separetly
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, aluminium conductor cable of size 25 to 50 sqmm, indoor/outdoor type including taking down/up old unservicable one.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, aluminium conductor cable of size 70 to 120 sqmm, indoor/outdoor type including taking down/up old unservicable one.
M&L for cable route indicator made out 35X35X6mm angle iron 150mm clear height with 100 mm embedded in PCC (1:3:6) type C1 (using 20mm graded stone aggregate) block of size 200x200x200mm with letter MES LT cable suitably incribed on CI circular plate 100 mm dia 5mm thick welded with angle iron incl necessary earth work and two coat of synthetic enemal paint blue colour over a coat of red oxide primer on steel surface complete all as specified and as directed.
M&L for cutting existing bituminous road surfaces of width not exceeding 150mm for laying of pipes/cables and making good with PCC 1:3:6 type C1 using 20 mm graded aggregate to match with the adjacent surface.
M&L for PCC, type C1, (1:3:6, using 20mm graded stone aggregates) as in coping of poles including formwork complete all as specified and as directed.
M&L for PCC, type D2, (1:4:8, using 40mm graded stone aggregates) as in filling to road cutting, foundation and mass concrete complete all as specified and as directed .
M&L Electrical Earthing complete with copper plate 60cm×60cm ×3.15mm thick burried directly in ground vertically at a depth not less than 2.25 mtr, below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level, connected to copper strip of size 20×3mm earth lead by means of bolts, nuts and washers of galvanised iron, earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board /panel board, all as specified and shown in MES schedule Electrical Plate No:-5 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:2:4 type C1 in chamber, RCC 1:2:4 type C1 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoal dust, salt, funnel for watering complete and testing the Earth resistence and writing on the chamber by paint all as specified and as directed. Note :- Length of earthwire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge. Note :- Length of earthwire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge. Note :- Length of earthwire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately.
Supply & Lay of HDPE pipe PN 10 of bore 100 mm for UG cable protection complete all as specified & directed. Note - Excavation and earth work will be measured and paid seperately under relevant item
Supply & Lay of HDPE pipe PN 10 of bore 50 mm for UG cable protection complete all as specified & directed. Note - Excavation and earth work will be measured and paid seperately under relevant item
Supply, laying and connecting 25 mm dia GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc and laid in trenches complete all as specified and directed. Note - Excavation and earth work will be measured and paid seperately under relevant item
Supply , laying and connecting 50 mm dia GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc and laid in trenches complete all as specified and directed. Note - Excavation and earth work will be measured and paid seperately under relevant item
Supply , laying and connecting 80 mm dia GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc and laid in trenches complete all as specified and directed. Note - Excavation and earth work will be measured and paid seperately under relevant item
Supply , laying and connecting 100 mm dia GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc and laid in trenches complete all as specified and directed. Note - Excavation and earth work will be measured and paid seperately under relevant item
Supply, laying and jointing 150mm dia ductile iron pipes with spigot and socket ends suitable for push on rubber joint centrifugally cast, class (K-9) , inner side cement lining and outer side black bitumen coating, laid in trenches including push on rubber (EPDM) ring with ISI marked complete all as specified and as directed
Supply and fix 150 mm dia CI Sluice valve with flanged ends as per IS-14846 PN-1.0 including stainless steel spindle and wheel , ISI marked with nut bolts and jointing material i.e. rubber gasket complete all as specified and directed.
Supply and fix 100 mm dia CI Sluice valve with flanged ends as per IS-14846 PN-1.0 including stainless steel spindle and wheel , ISI marked with nut bolts and jointing material i.e. rubber gasket complete all as specified and directed.
Supply and fix 80 mm dia CI Sluice valve with flanged ends as per IS-14846 PN-1.6 including stainless steel spindle and wheel , ISI marked with nut bolts and jointing material i.e. rubber gasket complete all as specified and directed.
S&F Gun metal gate valve class I (ISI) of 50mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F Gun metal gate valve class I (ISI) of 25mm dia marked with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M& L Ductile iron fitting such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable upto 200mm bore all as specified and directed.
M&L for construction of PCC block masonry valve pit of size 90 cm x 90 cm x 90 cm (inner dimension) with precast cement concrete 1:3:6 type C-1 solid block set in CM (1:4) with PCC M-7.5(Nominal mix) (using 40 mm graded stone aggregate) for foundation including 15mm thick plastering in CM (1:4) inside the valve pit and on external portion upto150mm below the ground level, including 3mm thick MS cover welded around with MS flat iron of size 40x6mm with provision of hings, handle and looking arrangement including MS angle iron frame of size 40x40x6mm fixed on top of valve pit by means of hold fast 150 mm long, embedded in PCC block 1:2:4, type B-1(using 20mm graded stone aggregate) of size 230mm x 200mm x 100mm including painting with two coats of anti-corrosive paint over a coat of red oxide zinc chrome primer including necessary earthwork in soft/loose soil, well ramming of soil around the constructed valve pit complete all as per drawing No TD/EM/06, Sheet No 1/2 & 2/2.
S & F of LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system wattage not less than 45 W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments.
Sr. Item No. 51 Contd/… The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including with necessary brackets / pipes clamps & nuts & bolts for holding the street light fitting and three core copper flexible cable of 1.5 Sqmm as required at site. incl suitable bracket for fixing complete all as directed.
Supply & fix mild steel TMT bar 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for Precast cement concrete block masonry with PCC 1:3:6 type C1 using 20 mm graded stone aggregate solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 including necessary formwork and moulds complete all as specified.
M&L for Precast Reinforced Cement Concrete type type B1 1:2:4, using 20 mm graded stone aggregate as in cover slab of man holes, septic tank, etc. set in Cement Mortar (1:4) including necessary form, mould work, etc. complete all as specified and as directed.
M&L for Plain Cement Concrete (1:3:6), type C-2 using 40 mm graded stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the completely surrounding pipes with concrete after they are laid and tested for 150mm bore pipe complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
M&L for Plain Cement Concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in benching of man holes including forming centre channels half round or 1/4 section complete all as specified and as directed.
Supply & Fix PVC (SWR) pipes 150mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors or any other situation complete all as specified and as directed.
M&L for Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces in two layers with first layer 10 mm thick and second layer 5mm thick, finished even and smooth without using extra cement, finishing coat shall be mixed with water proofing compound (WPC) as per manufacturers instruction complete all as specified and as directed. Note : WPC shall be measured and paid separately.
Supply only integral water proofing compound as per IS complete all as specified and directed.
M & L for RCC septic tank conventional type for 50 users design to carry sewage and sludge water constructed with RCC M-25 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m, brick work, plastering and as shown in TD drawing No. CESZ/2019/STD-01 sheet 1/1 and as specified and directed.
M & L for RCC septic tank conventional type for 100 users design to carry sewage and sludge water constructed with RCC M-25 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m, brick work, plastering and as shown in TD drawing No. CESZ/2018/STD-06 sheet 1/1 and as specified and directed.
Material & Labour for Soakage of size 3.25 M dia X 4.5 M effective depth including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC and as shown in TD drawing No. CESZ/2020/TD-45 sheet 1/1 & 2/2 complete filled with brick bats complete all as specified and directed.
Material & Labour for Soakage of size 1.6 M dia X 4.5 M effective depth including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC and as shown in TD drawing No. CESZ/2020/TD-45 sheet 1/1 & 2/2 complete filled with brick bats complete all as specified and directed.
Supply and fixing cable joining kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed including taking down/up old unserviceable one.
Supply and fixing cable joining kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed including taking down/up old unserviceable one.
Supply and fixing Cable joining kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core including taking down/up old unserviceable one.
Rajan Traders (BID ID -3300444)
PURBANCHAL BUILDERS (BID ID -3299882)
S.G.ENGINEERING COMPANY (BID ID -3300052)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .