Sr. Xen, Civil Works Division, PSTCL, Jalandhar.
Room No. 301, Shakti Sadan, Jalandhar.
Construction of all technical civil works for up-gradation of 66 kV S/S Chitti to 220 kV.
2026_POWER_161958_1
CWJ/T-21/2025-26
Open Tender
Civil Works
425 days
at 66 kV S/S Chitti.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹7.7 L
Yes
1 Jun 2026
26 Feb 2026
24 Apr 2026
26 Feb 2026
23 Apr 2026
26 Feb 2026
Earth work in excavation in foundations, trenches etc. In all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches , stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15 cm layers with compaction including diposal of all surplus soil as directed within a lead of 30 metres.
Earth filling Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Dismantling brick work tile, masonry or tile lining : In cement .
Dismantling Cement concrete plain1:2:4 mix .
Dismantling Cement concrete Reinforced cement concrete
Dismantling roofing Second class mud roofing
Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.
Scraping Bricks dismantled from brick work in lime or cement.
Removing doors and windows together with the dismantling of walls Doors
Removing doors and windows together with the dismantling of walls Windows
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.
Cement Concrete 1:8:16 With stone aggregates 40mm gauge (mixing by mechanical means using concrete mixer volumetric type) .
Cement Concrete 1:8:16 With stone aggregates 20mm gauge (mixing by mechanical means using concrete mixer volumetric type) .
Cement Concrete 1:6:12 with stone aggregate 40mm gauge(mixing by mechanical means using concrete mixer volumetric type)
Cement concrete 1:5:10 with stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure .
Damp proof course 7.5 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded.
Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines.
Supplying & laying dry brick bats
Extra for using needle vibrator where not included in the rates .
Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.
First class burnt work laid in cement sand mortar 1:7 in foundation and plinth
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level
First class burnt brick work laid in mud mortar in foundation and plinth
115mm thick brick wall in cement sand mortar 1:4 without reinforcement in foundations and plinth
Extra labour for First class burnt brick masonry in well steining of circular well.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing .
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16
Bottom Khurra on ground 1.2mx0.6m consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Providing and Fixing ceiling at height upto 4 mtr. consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and to the entire satisfaction of engineer-in- charge.
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia UPVC bend for rain water pipe as per IS : 14735 including jointing as per specifications and to the entire satisfaction of Engineer-in-charge. UPVC 110 mm bend
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material
Conglomerate floor 25mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Flat brick or tile flooring laid in cement sand mortor 1:4 on 100mm thick cment concret 1:8 :16 and 100mm thick sand filling and cement pointed 1:2 on top.
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.Size 600x600 mm
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing 10mm thick acid and/or alkali resistant tiles 300 mm x 300 mm of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge, in flooring or in dado / skirting on a bed of 12 mm thick mortar 1 : 4 (1 acid proof cement: 4 coarse sand).
12.5 mm thick cement plaster 1:3
12.5 mm thick cement plaster 1:4
12.5 mm thick cement plaster 1:5
12.5 mm thick cement plaster 1:6
20 mm thick cement plaster 1:4 in two coat work
20mm thick cement plaster 1:5 in two coat work
Plastering on underside of ceiling 10mm thick cement plaster 1:4
20mm thick cement plaster in damp proof course 1:3 with two coats of bitumen at 1.65Kg. Per Sqm laid hot and sanded Vertical
Finishing walls withcement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats with aluminum paint to give an even shade excluding priming coat
Painting two or more coats with anticorrosive bitumastic Paint to give an even shade
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Finishing walls with acrylic smooth exterior paint of required shade with two coats applied@ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Painting with acid proof paint of approved brand and manufacture to give an even shade two or more coats
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish
Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. Glazing and paneling to be paid for separately) : For fixed portion and chawkhats
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) Float glass panes of 5 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin- charge.
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm
Steel work fixed independently without connecting plates including cutting hoisting and fixing in position R S Joists
Steel work fixed independently without connecting plates including cutting hoisting and fixing in position FLATS (Labour Rate)
Mild steel requirement for RCC work where not including the complete rate of RCC including bending, binding and placing in position complete in all respects. Above 20mm dia bars (Labour Rate)
Cold twisted detormed (Ribbed/ ToR S teel Bar) Bars (Fe 500 grade as per IS 1786-1985) , for R.C.C works, where not including in the complete rate of RCC including bending and biding placing in position complete. (Labour Rate)
Welding by gas or by electric plant, including carriage to and from workshop etc.
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications
Brick on end edging Providing and laying of Brick on end edging 6.83cm wide, 11.11cm long and 22.86cm high half brick deep including excavation, refilling and disposal of surplus earth up to 50mtr complete as per Punjab PWD specifications
Boring for hand-pump in clay fitting strainer and pipe. Above 75mm dia bore but not exceeding 100mm. From 0 to 15 m.
Boring for hand-pump in clay fitting strainer and pipe. Above 75mm dia bore but not exceeding 100mm. Exceeding 15 m but upto 30 m.
Hand pumps Lowering pipe in the hole up to 40mm dia.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
110mm o/d PVC pipe of 4 Kgf. / sqcm
Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B Class including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete.
Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.
15mm i/d G.I. Union
20mm i/d G.I. Union
Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.
20mm i/d Gun Metal peet valve heavy pattern.
25mm i/d Gun Metal peet valve heavy pattern.
Providing & fixing Cast Iron suface box for Peet Valve, Stop Cock including all carriages complete
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 22.86 cm thick
Cutting holes upto 23cm square for pipes in flooring and roofs of bricks, tiles with lime concrete or cement concrete and making good the same & finishing according to existing finish where required
Through floor or roof 15.00cm thick
Excavation manually in trenches with straight or open cutting in built up street/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineerin- charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for all lifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects.
All classes of soil except rocky
Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineerin- charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects Depth upto 1.5 m B.G.L All classes of soil except rocky
Providing and fixing RCC manhole covers only 500mm i/d RCC man hole cover only as per ISI Heavy duty
Providing and fixing RCC manhole covers only 450mm i/d RCC man hole cover only as per ISI Medium duty
Foot Rest for Manhole. Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Providing and fixing RCC manhole covers only 450mm i/d RCC man hole cover only as per ISI Light duty
Providing and fixing RCC manhole covers only 455 x 610 mm rectangular RCC man hole cover only as per ISI Light duty
Providing, lowering, cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS: 651-2007 class Sp-1 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc., cutting of concrete beds and joints holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching, haunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun Jute yarn as per IS:1887, finishing and trowelling of each joint at an angle of 45 degree with the longitudinal axes of pipe, watering, keeping the joint covered and wetted till the same are cured, testing the sewerage line for leakage and making all leakages and defects good as laid in the contract specification, chipping and finishing the cut surface to uniform finish to the entire satisfaction of engineer-in-charge Including all cartage etc complete in all respects. 100mm i/d pipe
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.
For pipes 100 to 250 mm Diametre
Extra for every 0.30 metre depth of inspection chamber. 450mm x 450mm inside
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing C.P. brass 32mm short bend complete
Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 550 mm x 400 mm x 815 mm
Providing and fixing in position 32 mm dia G.I waste pipe embedded in wall upto floor level including cost of fittings complete as required by the Engineer-in-charge.
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. Vitreous chinaware standard white pedestal for wash hand basin.
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P. brass towel Rails size 15mm dia 610mm long
Providing and fixing in position C.P. Acrylic shelf with C.P. bracket and guard rails of approved make (to the approval of Engineer in-charge ) fixed in with rawl plugs and C.P brass screws complete in all respect
CP brass Acrylic Shelf size 560mmx130mm
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)
Size 600mmx450mm
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P.brass 15mm stop cock Male and female end
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.
PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut
Providing and fixing in position Centrifugally cast iron soil waste vent or antisyphonage pipes single socket to I.S.I. specification of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of lead jointing.
100mm i/d single socket Centrifugally cast iron pipe lines laid complete
75 mm i/d single socket Centrifugally cast iron pipe lines laid complete
Providing and fixing in position gratings 150mm x 150mm for gully trap. H.C.I. grating including painting with black bitumastic superior paint of approved manufacture three coats.
Providing lead caulked joints to H.C.I. pipes and specials conforming to I.S.I. Specification of E.L.C. manufacture or any other reputed firm including cost of lead yarn,fuel and tools etc.
100mm i/d (1.36 kg.)
75mm i/d (1.13 kg.)
Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc.
With 100mm x 75mm i/d Floor Trap (weighing 5.8 Kg)
Providing and fixing in position H.C.I special for soil waste vent or anti syphonage pipes to I.S.I specifications of E.L.C manufacture or any other reputed firm including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 100mm i/d pipes 100mm i/d H.C.I. Heal Rest Bend
For 100mm i/d pipes 100mm i/d Cowls
For 75mm i/d pipes 75mm i/d H.C.I. Heal Rest Bend
For 75mm i/d pipes 75mm i/d Collars
For 75mm i/d pipes 75mm i/d Cowls
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Triple Layer Tanks
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerincharge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
RECESSED HDPE PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100volts grade to be laid in HDPE electrical conduit pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point (withoutfan box)
Wiring fan point (with fan box)
Wiring light point
Wiring call-bell point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
HEAVY GAUGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
HGW Conduit Pipe 25mm dia. (1.6mm thick) On Surface
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 0.5-4amp. (10kA, Curve C)
MCB Single Pole 50, 63amp. (10kA, Curve- C)
Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 12 way each
Supplying and fixing Acid Vapour Proof Tube Fitting of Crompton Make (MODEL T5PFC11228EB) of 2x28 W T-5
Supplying and Fixing General Purpose tube Fitting of 20 watts LED of Havells make.
Supplying & Fixing 15 watt Panel Trim Havells make Round downlitter.
Supplying and fixing Ceilimg Light of 42 watt 2'*2' fitting of havells make.
Providing & Fixing of ceiling fan 1400mm sweep with regulator of crompton make.
Supplying and fixing exhaust fan 12” sweep of Crompton Make including louver ( MODEL T5JB1328EB) of 1x28 W T-5
Supplying and fixing exhaust fan 18" sweep of Crompton Make including louver (MODEL T5JB1328EB) of 1x28 W T-5
Providing and fixing wire gauge 12*22 size in aluminium section without cost of aluminium beading in section.
P&F Angle Iron Posts of various sizes and shapes as per PSTCL Drawing.
P&F 1mtr wide uc fencing gate for station T/f as per Arch. Drawing
P&F of GI wire netting mesh of 12 gauge 50 x 50 mesh 180cms. High fastened with 4 nos ms wire rope 6/7 strand 1/16" dia each complete in all respects as per drg no. HW/TB-5635R-2 and Arch Drg No. 8 Rs/ Job No. 112/S and conforming to IS- 2721/1974 and 3459/1977 respectively
P & F of 3BHP 3 phase NON Clog Pump crompton make
P/F of Steel gate type G-2 5.80 mtr wide as per Arch. Drawing
Prov./Fixing top post lantern (Gate Light) lantern of Crompton Make
P & F of barbed wire fencing consisting of glavanised steel barbed wire having dia 2.24mm( 2 Ply) barbed with 4 points as per IS 278/1962 i/c all fittings such as U clamp tighting nuts and bolts unrolling and strching complete.
P & F MS Base Plate 235X220X12 MM for T/F Plinth
P & F of MS Tappered washers/Cleats 65X65X6 mm 19mm for T/F Plinth.
Providing & Fixing 12.5 x 300 mm Anchor Bolts.
Providing & Fixing 30X30X3mm Angle Iron nosing for indoor cable trenches
Providing & Fixing MS checquered plate 5mm thick
Providing & Fixing Cable Racks of various sizes
P&F MS Angle iron Nozzing made out of 50x50x3 mm angle iron for cable trenches
P&F of MS Angle Nosing made out of 50x50x6mm
Suppling and Hoisting of Ferro Cement Trench Covers of size 2'8" x 1'6" T-1 & T-2 Type
Suppling and Hoisting of Ferro Cement Trench Covers of size 1'9" x 2'6" T-4 Type
Suppling and Hoisting of Ferro Cement Trench Covers of size 2'2" X 2'2" T-3 Type
Suppling and Hoisting of Ferro Cement Trench Covers of size 3'4"x1'6" T-p Type
P&F Template along with foundation bolts as per drawing
Cement Slurry of cement to sand ratio 1:6 with cement content not less than 150kg/100 sqm as per AOR
Suppling and Spreading of Gravel in yard area as per AOR
Laying PCC Flooring of Cement Concrete 1:5:10 with crushed stone & stone Aggregateas per AOR
desposal of debries as per AOR
Recovery of bricks
Recovery of brick bat
Recovery of tiles
Recovery of tiles bat
Recovery of Steel Scrap
Recovery of door
Recovery of window
Providing Earth Fillling as per AOR (including carriage and compaction,etc)
Extra Carriage of material- Cement
Extra Carriage of material- Steel
Extra Carriage of material- Fine sand
Extra Carriage of materials & diff. of rates of material- Coarse Aggregate 12/13.2 mm
Extra Carriage of materials & diff. of rates of material- Bricks
Extra Carriage of materials & diff. of rates of material- Coarse Aggregate 10/11.2 mm
Extra Carriage of materials & diff. of rates of material- Coarse Sand
Extra Carriage of materials & diff. of rates of material- Stone metal 40mm
Extra Carriage of materials & diff. of rates of material- Stone metal 63mm
Extra Carriage of materials & diff. of rates of material- Tiles
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.76 MB
TC.pdf
Tender Documents • 2.98 MB
TCAR.pdf
Tender Documents • 0.34 MB
TECHSPEC1.pdf
Tender Documents • 9.95 MB
TECHSPEC2.pdf
Tender Documents • 19.10 MB
DNIT.pdf
Tender Documents • 29.19 MB
BOQ_328120.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid