| Sl No | Description | Qty | Unit | Zenium Cables Limited | Prime Cable Industries Limited | Suyog Electricals Limited |
|---|---|---|---|---|---|---|
| 1.01 | 1Cx400 Sqmm 1.1 KV HR-PVC insulated Al conductor FRLS LT Power cable (Armoured) | 6,000 | Meter | 708.12 ₹835.58 | 672 ₹792.96 | 731.71 ₹863.42 |
| 1.02 | 10Cx2.5 Sqmm 1.1 KV HR-PVC insulated Cu conductor FRLS LT Control cable (Armoured) | 3,000 | Meter | 435.23 ₹513.57 | 411 ₹484.98 | 423.68 ₹499.94 |
| 1.03 | 3Cx185 Sqmm 6.6 KV HT XLPE-AL FRLS cable (Armoured) | 3,000 | Meter | - | 1,500 ₹1,770 | 1,686.06 ₹1,989.55 |
Updated dates
Tender Value
₹99 L
EMD Value
₹2.0 L
Closing Date
16 Mar 2026, 3:00 pmClosed
CE MM MPPGCL Jabalpur
O/o ED MM, MPPGCL, BLOCK No.8, GROUND FLOOR, SHAKTI BHAVAN, RAMPUR, JABALPUR (M.P.)
Manufacture and supply of L.T. and H. T. Cables for ATPS Chachai
2026_MPPGC_483382_1
CE(MM)/P-VII/LT HT Cables ATPS Chachai
Open Tender
Miscellaneous Goods
60 days
Jabalpur
As per NIT
25 documents required · 25 mandatory
₹2,000
Yes
₹2.0 L
Yes
27 Apr 2026
21 Feb 2026
17 Mar 2026
21 Feb 2026
16 Mar 2026
23 Feb 2026
1Cx400 Sqmm 1.1 KV HR-PVC insulated Al conductor FRLS LT Power cable (Armoured)
10Cx2.5 Sqmm 1.1 KV HR-PVC insulated Cu conductor FRLS LT Control cable (Armoured)
3Cx185 Sqmm 6.6 KV HT XLPE-AL FRLS cable (Armoured)
Please Enable Macros to View BoQ information
M.P. Power Generating Company Limited (MPPGCL)
Name of office O/o EXECUTIVE DIRECTOR (MATERIAL MANAGEMENT)
“TECHNO-COMMERCIAL BID ”
TENDER NO - 2026_MPPGC_483382_1 (SUPPLY OF L.T & H.T. CABLES FOR ATPS, CHACHAI, MPPGCL)
All the documentary evidences should be enclosed alongwith this questionnaire
PART ‘A’ GENERAL INFORMATION
ii) Write ‘Yes’ or ‘No’ wherever applicable
Name & Address of the Authorized bidder/Organization/Company etc.including e-mail address and fax number.
Furnish Following details:
Whether the bidder is an ancillary unit of organizations like M/s Alstom Power, M/s BHEL or any other manufacturer of main Plant for Power Station either in past or at present for spares of Turbines/Boilers/Electrcal/Auxiliaries/Coal handling Plant of Thermal power Station
Any other Information that bidder may like to give in order to Highlight his bid.
If yes, give details
PART ‘B’ : COMMERCIAL INFORMATION
ii) Write ‘Yes’ or ‘No’ wherever applicable
NOTE:-Please note that application or acknowledgement of application submitted by bidder to NSIC regarding registration/renewal of registration shall not be considered against exemtion of EMD.
If no, Give the Details
a) To be paid by MPPGCL
b)Not Applicable
c) If not appicable presently, and if become aplicable during execution of the contract, then same shall be born by you
d) Exempted
a) To be paid by MPPGCL
b)Not Applicable
c) If not appicable presently, and if become aplicable during execution of the contract, then same shall be born by you
d) Exempted
a) To be paid by MPPGCL
b)Not Applicable
c) If not appicable presently, and if become aplicable during execution of the contract, then same shall be born by you
d) Exempted
GST No.of MPPGCL 23AADCM4472A1ZZ
Any other tax applicable
if yes then Indicate name of any other applicable tax & rate of the tax
Mode of dispatch Dispatch by road on freight prepaid and door delivery basis is only acceptable.
a)Freight Charges
Indicated in price schedule against each item
b)NOTE:-
Please confirm that benefit of input tax credit has been passed on while quoting the rates.
Whether MPPGCL’s terms of payment is acceptable to the tenderer
if no, Give the offered Payment Details
Delivery Period
(If "NO " then give details)
(If "No " then give details)
Whether agreeable to MPPGCL’s penalty clause.
(if no, Give the Details)
Whether agreeable to the Guarantee Period as per Tender Specification
(if no, Give the Details)
Whether agreeable to furnish MPPGCL’s standard security deposit @ 10% of value of order for satisfactory execution of the order and to cover guarantee period plus six months Grace Period for settlement of liabilities.
(if no, Give the Details - in case of non-acceptance for submission of SD as per NIT requirement, your offer may be rejected without any further correspondence in this regard)
Indicate GST Registration Number & place of registration (Please note that in case of non-registration with GST Department, GST as admissible shall be deducted by the purchaser from the bills of service provider)
Please confirm that benefit of input tax credit has been passed on while quoting the rates
Whether photocopy of the profit / loss account, turn over 03 years upto the last financial year have been enclosed.
Whether you are agreeable to accept extension order on the same rates, terms & condition, if any extension order is placed within 06 months from the date of the placement of order.
Please mention whether rates offered are applicable for Part quantities/Part Items .
(if NO,than indicate the conditions)
Whether agreeable to all the other terms & conditions of tender specification
If No, then give details
Name, address & telephone No. of your local Representative (if any)
PART ‘C’: TECHNICAL INFORMATION
Whether material offered is exactly as per the technical specifications (Please clearly indicate the technical particulars of the item in your offer.)
If no, give details of technical deviations in technical deviations schedule
If no then give details
Whether pamphlets / technical details / literature furnished with the offer.
Whether the tenderer agrees to furnish material test certificate in respect of chemical composition & physical properties from Govt. / Govt. approved laboratory with each batch of supplies. (In case of Govt. approved laboratory documentary evidence regarding their recognition to be furnished)
Whether the tenderer has furnished details of manufacturing equipments & short history of plant.
Whether details of tests to be conducted,furnished along with references & copy of relevant I.S./Specification,as per tender specification
Note :- Please upload scanned copies of requisite documents alogwith the questionnaire.
M.P. Power Generating Company Limited (MPPGCL)
Name of office - O/o EXECUTIVE DIRECTOR (MATERIAL MANAGEMENT)
“TECHNO-COMMERCIAL BID ”
TENDER NO - 2026_MPPGC_483382_1 (SUPPLY OF L.T & H.T. CABLES FOR ATPS, CHACHAI, MPPGCL)
Sub : Schedule of Commercial Deviations.
The following are commercial deviation and variations from and exception to the tender specifications and documents.These deviations,and variation are exhaustive .Except these deviation the entire order shall be executed as per your tender specifications and documents.We agree that any condition,variation,deviation etc,If found elsewhere in the proposal, apart from relating to any rebates offered shall not be given effect to.
Bidder’s Name & Address :-
Any Commercial Deviation (if YES,filled details)
Security Clause
Penalty Clause
Validity Clause
Guarantee Clause
Payment Clause
Delivery Clause
Quantity Tolerance Clause
Any Other Deviation
Except for aforesaid deviations, the entire order, if placed on us, shall be executed in accordance with your tender specification and any other conditions, variation/deviation etc., if found elsewhere, in our offer should not be given any considerations while finalizing the tender. Note : 1- Any Deviation in payment , Penalty and guaranty clause may make your offer liable for rejection without any futher correspondence in this regard.
SCHEDULE - B
Sub : Schedule of Technical Deviations.
The following are technical deviation and variations from and exception to the tender specifications and documents.These Deviations,and variation are exhaustive .Except these deviation the entire order shall be executed as per your tender specifications and documents. We agree that any condition,variation,deviation etc,If found elsewhere in the proposal, apart from relating to any rebates offered shall not be given effect to.
Any Technical Deviation (if YES,fill details)
Note - Any Technical Deviation may make your offer liable for rejection without any futher correspondence in this regard.
M.P. Power Generating Company Limited (MPPGCL)
Name of office - O/o EXECUTIVE DIRECTOR (MATERIAL MANAGEMENT)
“TECHNO-COMMERCIAL BID -”
TENDER NO - 2026_MPPGC_483382_1 (SUPPLY OF L.T & H.T. CABLES FOR ATPS, CHACHAI, MPPGCL)
SCHEDULE - I
PROPOSAL DATA : PART-I
TECHNICAL PROPOSAL DATA
Bidder’s Name & Address :-
LT Power Cables
Specifications and Standards
Design ambient temperature
System Particulars (Fill separate columns for the following particulars for each type and size of cables)
Name of the Manufacturer
Place of manufacturer
ISI registration and validity date
Cable type
Applicable specifications and standards
Whether cable shall carry ISI mark
Voltage grade
No. of cores and size
Suitable for earthed/unearthed system
Permissible voltage and frequency variation for satisfactory operation
Voltage
Frequency
Voltage and Frequency combined Continuous current carrying capacity
For standard conditions as per IS
In air
In ground
In duct
In trench
For site conditions :
In air
In ground
In duct
In trench
De-rating factors for various conditions of laying are not worse than the ones specified in applicable IS Yes/No
De-rating factor for fire resistance treatment
Conductor
Material reference standard for conductor
Grad and Shape of conductor
Nominal cross section area
Number of wires
Diameter of wire
Diameter/size of conductor
Screening/Shielding / heat barrier tape (as applicable)
Material
Type/applicable std.
Thickness
Insulation
Between cores
Between cores and inner sheath
Screening/Shielding / barrier tape(as applicable)
Material
Type/applicable std.
Thickness
Whether triple extrusion technique for HT adopted? : Yes/No
Inner sheath
Armouring
Material
Type of armouring
No. and size of strip/wire
Whether galvanized Yes/No
Diameter of cable over armouring
Outer sheath
a) Material confirming standard/ type
b) Extruded Yes/No
Minimum Thickness of sheath
Tolerance on thickness of sheath
Min. tensile strength
Min. elongation percentage at rupture
Colour of Outer sheath
Whether outer sheath shall be of FRLS material and shall meet the special tests as per specification : Yes/No
a) Overall diameter of cable
b) Tolerance on O.D
Scheme for identification of cores
Short circuit withstand capacity
Short circuit current
Duration of short circuit
Formula relating short circuit(rms) and duration
Allowable/attainable maximum conductor temperature when carrying continuously currents as per item 2.09.00 above(-ºC)
Allowable/attainable maximum conductor temperature at the termination of short circuit current as per item 2.17.00 above(-ºC)
Cable constants
Max. DC resistance of conductor at twenty (20) °C
AC resistance per core at twenty (20) °C
Reactance per core at 50 HZ
Capacitance per core at 50Hz
Insulation
a) Insulation resistance constant Mega at 27°C and at max. rated temperature
b) Volume resistivity ohm cm at 27°C and at max. rated temperature
c) Min. tensile strength
d) Min. elongation percentage at rupture
Loss tangent
Dielectric constant
Maximum cable charging current at normal
operating voltage
Factory tests (Enumerate in detail for each type of cable)
a)Type tests
b) Acceptance tests
c) Routine tests
d) Special tests to prove FRLS/FS properties.
Is the offered cable guaranteed to safely withstand continuous conductor temperature of 85°C for XLPE Yes/No
Cable weight
Recommended minimum bending radius
Safe pulling force
Maximum allowable spacing for angle iron supports
Length of cable per drum
Cable drum
Cable weight
Shipping weight
Drum weight
Control Cables
Name of Manufacturer :
Place & Country of manufacturer. :
a) Applicable standards. :
b) Whether cable will carry ‘ISI’/Standard mark?
a) Cable type :
b) Voltage grade of cable
c) Voltage designation of cable (Uo/U) :
d) No. of cores x cross sectional area of conductor (sq.mm)
Suitable for earthed or unearthed system :
Permissible voltage & frequency variation for satisfactory operation :
a) Voltage :
b) Frequency :
c) Voltage & frequency combined :
Continuous current rating with single cable laid in air in an ambient temperature of 50°C and for maximum conductor temperature of 70°C for HRPVC (For single core cables, the continuous current rating shall be furnished both for armour earthed at one end and for armour earthed at both ends)
Permissible conductor temp. corresponding to
Maximum continuous current :
Maximum permissible conductor temp. for Emergency over- loading
De-rating Factors for the following shall be furnished
Variation in ambient air temp.(for cables laid in air from 30°C to 55°C in steps of 5°C) :
Variation in ambient ground temp.
(for cables laid direct in ground from 25°C to 50°C in steps of 5°C).
Grouping
De-rating Factors
Furnish chart showing de-rating factors for Different spacing of cables in horizontal
Formation in single row and in trefoil formation (for single core cables) as well as in different tiers under the following methods of laying. :
i) Cable laid in concrete cable trenches with Removable covers. :
ii) Cables laid in ground
iii) Cables laid in air :
iv) Cables laid in pipes or ducts
v) Variation in depth of laying for cables
Laid directly in ground
vi) Variation in thermal resistivity of soil Of cables laid directly in ground in range 600 mm to 1500 mm
Short Circuit Capacity
a) Short circuit Amp. (rms)
b) Duration of short circuit
c) Conductor temp. allowed for the short circuit duty
d) Formula relating short circuit (rms) And duration (sec.)
Conductor
a) Material of conductor (if copper state whether tinned/un-tinned)
b) Material of conductor conforms to (state standard)
c) Grade :
d) Nominal cross-sectional area
e) Number and diameter of wires
f) Shape of conductor
g) Maximum conductor resistance (DC) At 20°C (ohms/km)
Shielding on Conductor/ heat barrier type(whichever is applicable)
a) Material :
b) Type/Applicable standard
c) Thickness :
Insulation :
a) Composition of Insulation
b) Material of insulation conforms to (Stage std & type & grade) :
c) Nominal thickness of insulation
d) Tolerance on thickness of insulation
e) Minimum Insulation resistance at 20°C
f) Minimum volume resistivity for HRPVC Insulation at
i) 27°C / room temp.
g) Minimum tensile strength :
h) Minimum elongation percentage at rapture :
Shielding on Insulation/ binder tape ( as applicable)
a) Material :
b) Type/Applicable standard
c) Thickness :
Colour scheme for identification of cores
Furnish details :
Details and type of filters used in
interstices should be specified
Inner sheath
a) Material :
b) Extruded or wrapped?
c) Material of inner sheath conforms to (State std. & type) :
d) Calculated diameter over laid up cores:
e) Minimum thickness
f) Colour of inner sheath
g) Calculated diameter over inner sheath
h) Whether inner sheath will be of ‘FRLS’ type and will meet the special tests of Purchaser’s Specification for FRLS cables
Armour
a) Type and Material of armour
b) Material of armouring conforms to (state standard).
c) Calculated diameter of cable over
d) Inner sheath (or even insulation for Single core cables) (Under armour) mm.
e) Size of armour wire/strip
f) Number of armour wires/strips
Outer Sheath
a) Material :
b) Material of outer sheath Conforms to (state std. & type) :
c) Method of application
d) Calculated diameter under the sheath (over armour)
e) Minimum thickness of sheath :
f) Minimum tensile strength of outer sheath
g) Minimum elongation percentage At rupture
h) Colour of outer-sheath
i) State whether outer sheath will be of ‘FRLS’ type and will meet the special tests as per Purchaser’s specification for FRLS type cables
Overall diameter of cables
Tolerance on outer diameter
Weight of cable for 1000 meters (kg) (without drum).
Bending Radius :
Cable Constants
a) DC conductor resistance at 20°C Per 1000 meters
b) Approx. A.C. Resistance of conductor At 85°C
c) Calculated Reactance per phase at 50 Hz
d) Calculated Electrostatic capacitance Per phase at 50 Hz
Maximum charging current for cable
At nominal voltage
Test voltage & Voltage Duration
a) High Voltage tests
b) Water Immersion test
c) Test procedures conforms to(state std.)
Loss Tangent at normal frequency
Dielectric constant at normal frequency
Recommended minimum bending radius In terms of O.D. of cable
Recommended spacing of angle iron supports
Safe pulling force when pulled by pulling eye(kg)
A) Full details of tests proposed to be carried out and special tests for FRLS Cables
Whether all type test certificates enclosed
Whether progressive sequential marking on
Outer sheath of cables can be provided? (Yes/No)
De-rating factor for following Ambient Temperature In Air/Ground
Cable Drums
a) Dimensions
i) Flange diameter :
ii) Barrel diameter :
iii) Traverse :
b) Shipping weight of drum for standard Drum length
c) Standard cable length for drum For each size of cable (single length)
M.P. Power Generating Company Limited (MPPGCL)
Name of office - O/o EXECUTIVE DIRECTOR (MATERIAL MANAGEMENT)
“ TECHNO-COMMERCIAL BID”
TENDER NO - 2026_MPPGC_483382_1 (SUPPLY OF L.T & H.T. CABLES FOR ATPS, CHACHAI, MPPGCL)
SCHEDULE - II
PROPOSAL DATA : PART-I
TECHNICAL PROPOSAL DATA
Bidder’s Name & Address :-
Applicable Standard :
Voltage Grade :
Suitable for system with:-
Maximum Conductor Temperature :
Conductor:
Shielding on Conductor:
Insulation
Shielding on Insulation
Inner Sheath:
Armouring :
Overall Sheath:
Standard drum length with tolerance ........ mtrs.
Net weight of cables Kg/Km. :
Continuous current rating for Standard IS Condition laid direct
Short time current rating for 1 Sec. KA :
DC Resistance at 20 Deg.C.Ohm/km:
Electrical Parameters at maximum operating temperature :
Recommended minimum bending radius ........xOverall dia : :
Derating factor for following ambient temperature in air/ground
Group factor for following No. of cables laid touching/2x dia centre to centre
The cables shall be tested as per relevant standards and tender specification
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Tendernotice_1.pdf
PDF • 0.75 MB
emdformatnew1.pdf
Tender Documents • 0.10 MB
Model_Certificate.pdf
Tender Documents • 0.01 MB
annexureXV.pdf
Tender Documents • 0.18 MB
AnnexXItenderacceptance.pdf
Tender Documents • 0.11 MB
AnnexIVethicalpractice.pdf
Tender Documents • 0.18 MB
AnnexIIIsuccesfulexecution.pdf
Tender Documents • 0.18 MB
SBD_AMENDMENTS.pdf
Tender Documents • 0.65 MB
AnnexIXblacklisting.pdf
Tender Documents • 0.10 MB
Affidavit_for_no_solvency_bankruptcy.pdf
Tender Documents • 0.13 MB
SBD.pdf
Tender Documents • 2.30 MB
InstructionsToBidderForOnlineBidSubmission.pdf
Tender Documents • 0.45 MB
TS.pdf
Tender Documents • 1.02 MB
BOQ_568578.xls
BOQ • 0.36 MB
TnC_Schedule_483382.xls
Additional Documents • 0.43 MB
Download all tender documents and submit your bid