| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.2 L+₹5.4 L (15.0%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹44.0 L+₹8.2 L (22.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹45.4 L+₹9.6 L (26.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹67.4 L+₹31.6 L (88.4%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
22 Aug 2022, 6:00 pmClosed
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR, PO-GARHI, PIN-182121
Repair/Maint of street lights/security lights, post top lights, control switches, connected items and external water supply distribution system at certain different locations under GE (Utilities) Udhampur.
2022_MES_540828_1
GE/U-35/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (UTILITIES) UDHAMPUR
₹97,000
Yes
28 Sept 2022
25 Jul 2022
24 Aug 2022
25 Jul 2022
22 Aug 2022
8 Aug 2022
Amount
Taking down carefully Unserviceable Security light 60 watt /Flood Light/ High Mast light fitting from pole/Structure and repair/replacement of worn out parts such as driver, SPD etc, cleaning of fittings, cover, copper wire,clamps, nuts and bolts, mounting bracket and re assembling the same after repair, testing and refixing in pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of street light complete all as specified and directed by Engr-in-Charge. Note: - Replacement of defective spare parts of fitting (to make functional) will be measured and paid separately as supply only. However, cost of replacement screws, nuts, bolts, and cleaning of fittings shall be deemed to included in quoted rate.
All as per serial item No 1.00 here-in-before but Security/Street light fittings of 90 watt capacity.
All as per serial item No 1.00 here-in-before but Flood light fittings of 120 watt capacity.
All as per serial item No 1.00 here-in-before but Flood light fittings of 150 watt capacity.
Supply, Laying and jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 2.5 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engr-in-Charge.
Supply, Laying and jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 4 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engr-in-Charge.
Modular box of size 333 x 233 x 120 mm (in replacement) made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts complete all as specified and directed by Engr-in-Charge.
MS bracket for street light fittings made out of 40 mm dia GI pipe (in replacement) of medium grade 1.5 mtr long each bent to required shape & size and fixed to pole with and including flat iron clamps 02 Nos made out of 32x6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coats of aluminium paint over a coat of red oxide primer and fittings bracket to street light fittings complete all as specified and directed by Engr-in-Charge.
150 Watt LED Flood light (in replacement) with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engr-in-Charge.
120 Watt LED Flood light (in replacement) with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engr-in-Charge.
90 Watt LED street light (in replacement) with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 9000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engr-in-Charge.
60 Watt LED street light ( in replacement) with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engr-in-Charge.
60 Watt inverter type (in replacement) LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engr-in-Charge.
90 Watt inverter type (in replacement) LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engr-in-Charge.
15 Watt new generation, Post top lantern, energy saving, enviornmentla friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminarie with high power LEDs with IP-65 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 1500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided complete all as specified and directed by Engr-in-Charge.
Dismantling of old unserviceable steel tubular pole swaged pole/PCC pole including PCC complete with acessories complete all as specified and directed by Engr-in-Charge.
Dismantling of old unserviceable/broken/jointed ACSR conductor or earth wire from poles and removing from site of work complete all as specified and directed by Engr-in-Charge.
Taking down existing old cross arms of MS channel or angle sections etc all as specified and directed by Engineer-in-Charge.
Cleaning the existing exposed surfaces of steel tubular pole of 11.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laid in trenches or passing through pipe or fixed on poles complete all as specified and directed by Engr-in-Charge.
All as per serial item No 20.00 here-in-before but of size 16 Sqmm 4 core.
All as per serial item No 20.00 here-in-before but of size 25 Sqmm 4 core.
All as per serial item No 20.00 here-in-before but of size 35 Sqmm 3.5 core.
Taking down the old unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge
All as per serial item No 25.00 here-in-before but depth exceeding 1.5 mtr and not exceeding 3 mtr complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
Plain cement concreate M-15(1:2:4),type B-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specified and directed by Engr-in-Charge.
PCC M-7.5(1:4:8),type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc complete all as specified and directed by Engr-in-Charge.
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles, under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe complete all as specified and directed by Engr-in-Charge.
Erecting steel tubular swaged poles ( in replacement) erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engr-in-Charge. Note: - Excavation and Earth Work, PCC in foundation shall be measured and paid for separately.
Supply and installation (in replecement) steel tubular swaged poles Type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and double swan neck, Including foundation and coping.with necessary Foundation RCC 1:1:5:3 with 8Nos.16 mm dia tor bar as main bars and 8mm dia.Tor bars strips@190mm c/c as this reinforcement shall confirm to IS : 1786 latest edition.The foundation shall extend above surroundings ground/drive way level for 200 mm and have DWC 63 mm dia,PVC sleeve cast foundation for cable entry,Excavation,RCC and reinforcement etc as per manufacturer recommendation and the cost of necessary foundation , steel bars , strip as per Manufacturer instructions complete all as specified and directed by Engr-in-Charge.
Power contactor 3 phase 415 Volts, 40 Amps, coil voltage of rating 240 Volts (in replacement) including taking down old unserviceable power contactor complete all as specified and directed by Engr-in-Charge.
Power contactor 4 pole 240 Volts, 30 Amps , coil voltage of rating 240 Volts (in replacement) including taking down old unserviceable power contactor all as specified and as directed by Engr-in-Charge.
Supply only Driver for LED energy saving & enviornment area light fitting > 75 watts security light with active power factor correction (APFC) electronic driver. LED driver 75 Watt with operating voltage between 100-270 V of existing specifications & make complete all as specified and as directed by Engr-in-Charge.
Supply only Driver for LED energy saving & enviornment area light fitting > 45 watts security light with active power factor correction (APFC) electronic driver. LED driver 45 Watt with operating voltage between 100-270 V of existing specifications & make complete all as specified and as directed by Engr-in-Charge.
Supply only Surge protection 5 KV devices compatible with industrial & outdoor LED fixtures upto rated power of 45 W & up to 150 W with operating voltage between 100-270 V of existing specifications & make complete all as specified and as directed by Engr-in-Charge.
MS Channel/angle iron/flat iron (in replacement) of required size and bend to shape as cross arms, bracing and support including MS clamps back plates with bolts, nuts, and washers drilled for insulators including painting two coats of synthetic enemel paint (Aluminium shade) over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Aluminium conductor steel reinforced (ACSR) in replacement ) any size on poles, stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with Aluminium binding wire complete all as specified and directed by Engr-in-Charge.
MCCB four pole 63 Amps, 50 Hz (in replacement) with breaking capacity 16KA, Ics = 100% Icu , 415 Volts, Adjustable thermal & Fixed magnetic setting including making all incoming/ outgoing connections complete all as specified and directed by Engr-in-Carge.
On load change over switch 200 Amps, 415 Volt, 4 pole complete all as specified and directed by Engr-in-Charge.
On load change over switch 100 Amps, 415 Volt, 4 pole complete all as specified and directed by Engr-in-Charge.
On load change over switch 63 Amps, 415 Volt, 4 pole complete all as specified and directed by Engr-in-Charge.
Heat shrinkable End joint for PVC/XLPE (in replacement ) insulated armoured cable of size upto 50Sqmm 3.5/4 core complete all as specified and directed by Engr-in-Charge.
All as per serial item No 46.00 here-in-before but for LT cable size of 70 to 150 Sqmm.
Cuttig of existing road for crossing of underground electric cable for laying of any size GI tubing including necessary excavation and earth work including repairing the same as per existing with pre mix bituminious carpet complete all as specified and as directed by Engr-in-Charge. Note: - Width of trench shall be 15 cm and depth shall be upto 30 cm.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized iron earth wire 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, CI pit cover of size 30cmx30cmx10mm with angle iron frame and handle, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-Charge.
Rectification of leakage of UG water pipe lines of size 150 mm Bore of any description such as CI/DI pipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and as directed by Engr-in-Charge.
All as per item No 52.00 here-in-before but of size100mm dia pipe line.
All as per item No 52.00 here-in-before but of size 80mm dia pipe line.
Rectification of defective run lead joint by burning out lead joint in position including recovering lead and making new lead joint for 200 mm bore including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines complete all as specified and directed by Engr-in-Charge.
All as per item no 55.00 here-in-before but of size150mm dia pipe line.
All as per item no 55.00 here-in-before but of size 100 mm dia pipe line.
All as per item no 4.00 here-in-before but of size 80mm dia pipe line.
Attending Complaints for rectification of leakage of UG water pipe lines of size 100 mm Bore of GI pipe at any location including necessary excavation, earth work, dewatering including Cutting existing line & Welding with new one or repairs with suitable flanges, Joints or any other material complete all as specified and as directed by Engr-in-Charge.
All as per item No 59.00 here-in-before but of size 80mm dia pipe line.
All as per item No 59.00 here-in-before but of size 50mm dia pipe line.
All as per item No 59.00 here-in-before but of size 40mm dia pipe line.
Note for Item No 52.00 to 62.00 (i) Complaint shall be notified to contractor on mobile phone. Hence, it is mandatory to mention his mobile No. while quoting the tender. (ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and will be rectified within 12 hours after notification, failing which double of quoted rate per day per complaint will be recovered. (iii) Completion report of the complaint shall be given in writing and recorded in the register. (iv) Rates quoted shall be deemed to included the cost of T&P required. Pipes and Jointing material shall be measured and paid under relevant items of schedule (BOQ).
Attending leakage complaints of sluice valves 150mm bore by packing stuffing box, removing gland plate and pumping/taking water from water pit and proving gland packing and refitting by replacing worn out bolts,nuts and washers complete all as specified and directed by Engr-in-Charge. Note: bolts,nuts and washers should be included in quted rate.
All as per item No 63.00 here-in-before but of size 100mm dia pipe line.
All as per item No 63.00 here-in-before but of size 80mm dia pipe line.
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 15 mm complete all as specified and directed by Engr-in-Charge.
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm complete all as specified and directed by Engr-in-Charge.
Demolition of existing valve pit chamber and M&L for brick masonry valve pit of size 900x900x900mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer complete with locking arrangement complete all as specified and directed by Engr-in-Charge.
CI /DI Specials/fittings including breaking/taking out defective CI specials for spigot and socket end for CI mains upto 150 mm dia complete all as specified and directed by Engr-in-Charge.
Cast iron flanged drilled heavy duty sluice valve (in replacement) with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers of size 150 mm bore etc complete all as specified and directed by Engr-in-Charge.
All as per item No 70.00 here-in-before but of size 100mm dia.
All as per item No 70.00 here-in-before but of size 80mm dia.
Gun Metal globe or Gate valve, iron wheel head, screwed both ends for iron pipes of size 50mm dia bore complete all as specified and directed by Engr-in-Charge.
All as per item No 73.00 here-in-before but of size 40mm dia.
All as per item No 73.00 here-in-before but of size 25mm dia.
All as per item No 73.00 here-in-before but of size 20mm dia.
All as per item No 73.00 here-in-before but of size 15mm dia.
Dewatering and cleaning of overhead MS tank of capacity 20 KL gallons with high pressure jet to remove all masses ,algae and dirt and removal of dirty water along with sludge using sludge machine and disposal of same to a safe distance and including scrubbing of internal surface using industrial vacuum machine and applying of anti-bacterial sterilization spray and apply one coat food grade paint to wall , floor and ceiling , internal surface of reservoir where applicable all as specified and directed by Engr-in-Charge.
Taking down carefully old GI pipe of size 15 mm bore and setting aside for reuse if found serviceable complete all as specified and directed by Engr-in-Charge.
All as per serial item No 79.00 here-in-before but of size 20 mm bore.
All as per serial item No 79.00 here-in-before but of size 25 mm bore.
All as per serial item No 79.00 here-in-before but of size 40 mm bore.
All as per serial item No 79.00 here-in-before but of size 50 mm bore.
All as per serial item No 79.00 here-in-before but of size 80 mm bore.
Refixing old steel tubing and connections in new or old position (walls, ceiling , floors, etc) of size 20 mm bore complete all as specified and directed by Engr-in-Charge.
All as per serial item No 85.00 here-in-before but of size 25 mm bore.
All as per serial item No 85.00 here-in-before but of size 40 mm bore.
All as per serial item No 85.00 here-in-before but of size 50 mm bore.
All as per serial item No 85.00 here-in-before but of size 80 mm bore.
Supply laying and testing of GI tubing 15 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed by Engr-in-Charge.
All as per serial item No 90.00 here-in-before but of size 20 mm bore.
All as per serial item No 90.00 here-in-before but of size 25 mm bore.
All as per serial item No 90.00 here-in-before but of size 80 mm bore.
All as per serial item No 90.00 here-in-before but of size 50 mm bore.
All as per serial item No 90.00 here-in-before but of size 40 mm bore.
Prepration of surface of water pipe line above the ground level for Panting with two coats of weather proof, synthetic enamaled paint over one cote of primer complete all as specified and directed by Engr-in-Charge.
Supply and laying CI pipe line with spigot and socket ends and centrifugaly cast class A in any length laid in trenches of size 80 mm dia complete all as specified and directed by Engr-in-Charge.
All as per serial item No 97.00 here-in-before but of size 100 mm bore.
All as per serial item No 97.00 here-in-before but of size 150 mm bore.
All as per serial item No 97.00 here-in-before but of size 200 mm bore.
Supply ,installation ,testing and commissioning (in replacement) of feeder pillar board Kiosk type ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design complete Bus Bar chamber comprising incomer MCCB 315 Amp, 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engr-in-Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete as specified and directed by Engr-in-Charge.
Carry out Servicing from authorised rep or service engineer of the manufacturer of Industrial R.O+U.V. Water purifier system consisting of Fiber Reinforced Polymer Vessel with treatment media like FBM, AFM, MGS, ACM, CPM, etc of capacity 1000 LPH,complete all as specified and directed by Engr-in-Charge.
Attending Complaints for rectification of fault in RO i panel (contorl Panel) of Industrial R.O+U.V. Water purifier system consisting of Fiber Reinforced Polymer Vessel with treatment media like FBM, AFM, MGS, ACM, CPM, etc of capacity 1000 LPH including replacement of worn out relay, cable, fuse,diode etc complete all as specified and as directed by Engr-in-Charge.
Supply, fixing & testing (in replacement) of GSM based RO i panel (contorl Panel) of Industrial R.O+U.V. Water purifier system consisting of Fiber Reinforced Polymer Vessel with treatment media of capacity 1000 LPH complete all as specified and as directed by Engr-in-Charge. Make: Renuka water Tecnology or equvalant in Havells, L&T. Note: Model should be compatable for existing RO plant.
Supply, fix and testing food grade Activated carbon for RO plant of capacity 1000 LPH complete all as specified and as directed by Engr-in-Charge.
Supply,fix and testing food grade softner Resin 220 Na for RO plant of capacity 1000 LPH complete all as specified and as directed by Engr-in-Charge.
Supply,fix and testing 20" Jumbo Span Candel for RO plant of capacity 1000 LPH complete all as specified and as directed by Engr-in-Charge. Note : Model should be compatable for existing RO plant.
Supply,fix and testing RO Membrane 40 x 40 for RO plant of capacity 1000 LPH complete all as specified and as directed by Engr-in-Charge. Note : Model should be compatable for existing RO plant.
Supply and filling clean wash sand for RO plant of capacity 1000 LPH complete all as specified and as directed by Engr-in-Charge.
Supply and filling (NaCl) (Common Salt) for RO plant of capacity 1000 LPH complete all as specified and as directed by Engr-in-Charge.
K S BUILDERS
proach associates
m/s fangalia traders
slathia construction works
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .