Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC PANCHAYATI RAJ ROHTAK | L1 | Accepted-AOC ok | |
| 2 | L2₹16.4 L+₹1,749.98 (0.11%)Rejected-Finance | L2 | Rejected-Finance ok | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Copy of HEWP Registration certificate not attached |
Tender Value
₹17.2 L
EMD Value
₹34,000
Closing Date
23 Dec 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Anil Narwal
EXECUTIVE ENGINEER PROV DIV NO 4 PWD B AND R PGIMS ROHTAK
Construction of Gas Plant Room in open area behind Psychiatric Deptt in University of Health Sciences Rohtak COVID 19
2021_HRY_200087_1
PWD/P4/677
Open Tender
Civil Works
Works
90 days
PGIMS Rohtak
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹34,000
Yes
22 Feb 2022
16 Dec 2021
23 Dec 2021
16 Dec 2021
23 Dec 2021
16 Dec 2021
120 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge.:- All kinds of soil (HSR 4.12.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level:- 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size) (HSR 6.1.4)
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size):- 40mm thick (HSR 6.8.2)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:-Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.21.2)
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in :- Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed.110 mm diameter (HSR 9.57.2)
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling.:- Re-compacting excavated soil in plinth under floors, including watering, ramming, consolidating and dressing complete.(HSR 10.1.1)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(HSR 10.62)
Laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (HSR 10.63.2) Size of Tile 600x600 mm (Tiles shall be Supplied by the department). (Labour rate)
12 mm cement plaster of mix :-1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.6.2)
Applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 11.58) (Labour rate)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:- New work (two or more coats) over and including water thinnable priming coat with cement primer.(HSR 11.64.1) (Labour rate)
Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 litre/1O sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (HSR 11.95.1) (Labour rate)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:(HSR 12.9)
12.9.7:- Float glass panes
12.9.7.2:- 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws.(HSR 12.10) 12.10.2:- Kiln seasoned and chemically treated Hollock wood 12.10.2.2:- 30 mm thick
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws:(HSR 12.19) 12.19.2:- 30 mm thick shutters. 12.19.2.1:-with ISi marked M.S. pressed butt hinges bright 12.19.2.1.2:- Kiln seasoned and chemically treated Hollock wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.(HSR 12.36)
12.36.1:-35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws
Supply & fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm & Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets & screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1 :2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire satisfaction of Engineer-in-charge.(HSR 13.21)
13.21.2:- Door Frame of size 125mm x 60mm with 37mm wide double metre rebate for 35mm door shutter
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes (HSR 13.30.1)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.(HSR 4.33)
Fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:(HSR 22.1) (Labour rate)
22.1.1:- White vitreous chinaware Wash basin size 630x450 mm with a pair of 15 mm C. P. brass pillar taps (Labour rate)
Fixing white vitreous chinaware water closet squatting pan (Indian type):-Orissa pattem W.C. pan of size 580x440 mm (HSR 22.28.2) (Labour rate)
Fixing partitions for different type of urinals. Vitreous Chinaware Partition plate. (HSR 22.50.1.1.2) Single Colour (Labour rate)
Fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.(HSR 22.106.1)15 mm nominal bor (Labour rate)
Fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bor (HSR 22.107.1) (Labour rate)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm (HSR 22.210.2)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(HSR 22.181)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(HSR 22.85)
22.85.2:- 20 mm nominal outer dia Pipes
22.85.3:- 25 mm nominal outer dia Pipes
22.85.5:- 40 mm nominal outer dia Pipes
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade.:- One or more coats on old work(HSR 30.28.1) (Labour rate)
N.S ITEMS
Providing & fixing of composite factory made dis-continuous line prefabricated sandwich LP/HP-PUF 50/80 mm roofing panel comprising of two sides facing of colour coated galvanised steel sheet and sandwiched between them CFC free close cell high density rigid polyurethane (PUF) foam insulation of 40+2 kg/m3, having a thermal conductivity value of 0.023 w/mk. The top & bottom sheel shall be off white RAL9002 galvanised steel sheet of 0.5 mm TCT steel min 240 Mpa having a coating Mass of min 120 gsm zinc. coating total of both sides as per IS:277 and finished with 20 microns colour coating of SMP polyester quality paint coat over a 5 microm primer on exposed side and back coat of 5 microns on inner side over a 5 microns primer.
The top sheet shall have profile depth of 41- 44 mm at a pitch distance of 300-333 mm. The inner sheet shall be in the form of a liner tray. The outer profile sheel and the inner liner tray shall have core of 50 mm thick polyurethane (PUF) foam insulation. The PUF insulation shall have fire retardant and self extinguishing properties as per IS 12436. The Panels should be of required length and 1 Mtr in width. The prefabricated panels shall be fixed throught the Profies directly to the purlins using self-grilling fasteners with neoprene washers mechanically with the help of machines. The metal sheet shall conform to IS:513, As:1397 & 2728. The Polyurethane foam (PUF) insulation shall conform to IS:12436 (N.S)
Providing & fixing of composite factory made dis-continuous prefabricated sandwich panel - LP/HP-80 mm thick PUF for wall comprising of two sides facing of colour coated Galvanised steel sheet and sandwiched between them CFC free close cell high density rigid polyurethane foam 40+ 2 kg/m3 having a thermal conductivity value of 0.023 w/mk. The outer & inner sheet shall be off white RAL9002 galvanised steel sheet of 0.5 mm TCT steel min 240 Mpa having a coating mass of min 120 gsm zinc coating total of both sides as per IS: 277 and finished with 20 microns colour coating of SMP polyrster quality paint coat over a 5 micron primer on exposed side and back coat of 5 microns on inner side over a 5 microns primer. The outer and inner sheet shall have a core of 50 mm thick polyurethane foam insulation. The PUF insulation shall have fire retardant and self extinguishing properties as per IS 12436. The Panels should be of required length and in 1190 mm width with tounge and groove arrangment on the sides having hidden fastener jointing arrangement. The prefabricated panels shall be fixed to the support structure. The metal sheet shall conform to IS:277 & 14246. The polyurethane insulation shall conform to IS:12436. The work shall be carried out as per direction of E.I.C (N.S)
Providing & fixing of guttermade out of 0.5 mm PPG/PPGL sheet including ridge cap (N.S)
Providing & fixing of flashing gutter, down take pipe made out of 0.5 mm TCT Galvanized steel sheet (N.S)
The DRN Cooperative Multipurpose Society Ltd. Gohana
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .