Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 201 A SHUBHAM CENTRE NO 1 CARDINAL GRACIOUS ROAD VILLAGE TOWN CHAKALA ANDHERI EAST CITY MUMBAI MUMBAI MAHARASHTRA 400099 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400099 | Admitted-Finance |
Tender Value
₹54.9 L
EMD Value
₹1.1 L
Closing Date
5 Oct 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIRECTOR TMC
Office of Engineering services, Second Floor,Khanolkar Shodhika , ACTREC Kharghar Node, Navi Mumbai 410210
Supply,Installation,Testing and commissioning of Ventilation system for Shanti Sadan at ACTREC
2023_TMC_772138_1
ET-96/SITC Of Ventilation System/2023
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
150 days
ACTREC-Kharghar
As per Tender Document
2 documents required · 2 mandatory
₹0
₹1.1 L
Yes
ACTREC, KHARGHAR
15 Jan 2024
18 Sept 2023
6 Oct 2023
18 Sept 2023
5 Oct 2023
18 Sept 2023
18 Sept 2023 - 25 Sept 2023
26 Sept 2023
Amount
DX condensing Units
SITC of DX Outdoor Units complete with Rotary/scroll based type compressors & eco-friendly referigerant gas, cooling mode, low noise condenser fans, GI coated condenser stands, microprocessor panel with sequential starting of condensing unit, coils, expansion valves, Cu cabling, single phase preventor, all vibration isolators, Cowl Piece with Flexible Connection, safeties etc. ODU to have specially factory coated treatment for heat & rust corrosion for panels, motor, electricals & heat exchanger etc. condenser coil should be with blue fins and all necessary fittings and hardware as per instructed and as directed by OIC-ES. Air on condenser 45 Deg C. Note- Unit include with the condenser stand.
11TR with Expansion Wall, DRY and stand (or MS stucture if require)
Air handling Units
Supply, installation,testing and commissioning of factory built/site assembled Eurovent Certified/AHRI/BIS Certified/Equivalent , Horizontal/Vertical - Air handling units in Double skin type (Casing shall be of Non-Skeleton construction) with 40 ± 5 MM thick panels or Higher. AHU Construction should meet Mechanical performance of AHU casing as tested in Eurovent accredited laboratory as per EN1886 and meet the following characteristics: Mechanical Strength: D1, Thermal Bridiging: TB2, Thermal Transmittance: T2,Air lekage:L1 and Filter by pass: F9 or Higher Characterstics. The said mechanical performance should be meet by each AHU as mentioned below. AHU construction should consist of G.I casing of thickness 0.8 mm outside layer and 0.8 mm inside layer with 275 GSM or eqvivalnet zinc coating and polyurethene foam(PUF) insulation having density of 42 kg/m3, complete with Backward curved aerofoil blade Belt driven fan of Aerofoil design blade alongwith VFD suitable for static pressure as detailed below certified by OEM, chilled water cooling coil with aluminium finned copper tubes. Filter section having pre (EU4, more than 90% efficiency for 10 Microns EU 13 more than 95% efficiency for 10 Microns ), IE3 motor suitable for 415 +10% volts,50 Hz, 3 phase AC supply,drain connections with stainless steel drain pan and necessary vibration isolation arrangement to avoid any vibration etc. complete as per specifications. The static pressure should be verified as per actual site conditions. VFD should be capable to controll the speed of the fan.External Static considered is 25-30 mm. All accessory should be considered for the proper functioning.Cooling coils hould be 8 row.The VFD shall be suitable for atleast One PIDs. The scope shall include the AHU starter panel shall include VFD with bypass starter, temprature controller with suitable field sensor and wiring. suitable for input Voltage of 380 Vac to 480 Vac + 10% to -15% with inputs frequency of 50Hz +/- 5%. Overload shall be 120% for 60 Sec & VFD Shall be rated at 50 DegC. Temperature sensor should be included. VFD should be with weather proof enclosure. Sound level should not exceed 65 dbA at 1m.Mixing Box and Fresh Air Damper to be provided. Drain Pain to be provided with 18G SS or higher. Price include with AHU control panel and control cable, power cable from panel to AHU. All the cable and copper pipe should laid on cable perforated type tray as per instructed and as directed by OIC-ES.
4000 CFM with (1W+1S) motor and 20TR capacity
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric 19mm nitrile rubber with GC cloth tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. Note:- individual piping will not be measured All pipe should be laid in ladder/perforated type tray. External pipe should be cover with GI caping cable tray.
5/8",1" 1/8" with 1.2mm tube thickness and insulation as per OEM standard. Or equivelent to the unit of 11 TR
Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows, tees, reducers,sockets,u trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system complete. Nominal diameters of pipe in mms as indicated below:
25 mm dia pipe, Insulation thickness - 19 mm
Supply, laying & termination of copper cable from Departmental power supply/control cable to IDU & between IDU and ODU unit. Complete with lug fitting, ferruling, gland fitting etc. All Cable should be laid in GI perforated cable tray.
Design, Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications and as per SMACNA standard of following sheet thickness complete as required. Hot dipped Galvanised with 120GSM Zinc coatingThe price shall include necessary scaffolding required for working at required height.
Thickness: 0.63 mm Sheet
Thickness: 0.8 mm Sheet
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required thick ness of insulation is 19mm.
Design, Supply, installation, balancing and commissioning of Air fabric duct 100% polyester endless fibre(Multifilament) weight 225 g/m2, thickness 0.31mm, permebility 0m3/h/m2 by 120 pa.Strength (wrap/weft) 1810/1090 N (EN ISO 13934-1:1999) Fire resistance B-s1, d0 accordingly to EN 13501-1+A1:2010 & UL 723, Temprature resistance -30a +110C, washing shirinkage (Wrap/weft) 0.5/0.5% by 40C according to EN ISO 6330-2000, suitable fo cleanroom class no 4 (EN ISO 14664-1) washable in washing machine end blanking stiffner. duct Colour as per instructed and as directed by OIC-ES.The price shall include necessary scaffolding required for working at required height.
Supply, installation, testing and commissioning of GI volume control duct damper/Non Return damper 18 guage GI. frame & 20 guage GI blades complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
SITC of Motorized (ON-OFF type) duct mounted GI Volume control damper with enthalpy sensor and necessary control wire (minium 1.5 sqmmm) for integrated with AHU
Fire damper actuator UL listed suitable for above damper
SITC of Jet diffuzer with eye bolt type with 400 mm size with all necessary hardeware and fitting as per instruction and as directed by OIC-ES
Removing and refixing of polycarbonate sheet and other civil work realted to project as per instructed and as directed by OIC-ES.
SITC of Main feeder piller panel IP 67 incomer MCCB 200A 415volt 3 ph , 50HZ , TP+N 200 A-30kA MCCB-FROH with cable spreader , Manual, with integral LSIG protection, 3x metering CTs, MFM(EM6459), R/G/A lamps , R Y B indication , Voltmeter , On OFF Trip Indication , Rotory operating knob from outside suitable for connection of 3.5c x 150sqmm Cable , Pahse seperator , Protection sheet , Outgoing - 63A TPN MCCB 05 Nos , The work aslo includes MS channel foundation required for installation of panel , painting work and complete as directed by EIC ES. Panel manufacturer to be CPRI approved.
Supply, installation ,testing & commissioning the following cable on wall/floor/ceiling/structure member or on cable trays or down through PVC pipes, using MS spacers and GI saddles, cable clamp etc. complete in all respect. Cable, conforming to IS: 1554/Part 1/1998, XLPE, Aluminium stranded conductor, armoured, 1100 V class
3.5Cx35 Sq.mm A2XFY Aluminium Conductor cable
3.5Cx150 Sq.mm A2XFY Aluminium Conductor cable
SITC of Cable glands shall be Double compression type, tinned/Nickel plated (coating thickness not less than 20 microns in case of tin and 10 to 15 microns in case of nickel) brass cable glands for all power and control cables. They shall provide dust and weather proof terminations. They shall comprise of heavy duty brass casting, machine finished and tinned to avoid corrosion and oxidation. Rubber components used in cable glands shall be neoprene and of tested quality. Required number of packing glands to close unused openings in gland plates shall also be provided. The cable glands shall be tested as per BS: 6121. The cable glands shall also be duly tested for dust proof and weather proof termination.
SITC of gland for 3.5 x 35sqmm cable
SITC of gland for 3.5 x 150sqmm cable
Cables lugs shall be tinned copper solder less crimping type conforming to IS: 8309 and 8394 suitable for aluminium or copper conductor (as applicable). The cable lugs shall suit the type of terminals provided. The cable lugs shall be of Dowell make or equivalent.
SITC of Lugs for 16Sqmm
SITC of Lugs for 35Sqmm
SITC of Lugs for 70Sqmm
SITC of Lugs for 150Sqmm
SITC of 8 SWG tinned copper bare wire including all fixing accessories
ask enterprises
WEATHER COOL SALES PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .