Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.0 CrAccepted-AOC | ₹24.0 Cr | L-1 | Accepted-AOC Lowest and reasonable bid |
| 2 | L-2₹25.7 CrRejected-AOC PROP ZISHAN ALI ADARSH NAGAR NEW BUS STAND RAMGARH CANTT RAMGARH | ₹25.7 Cr | L-2 | Rejected-AOC Other than lowest bid |
| 3 | L-3₹26.0 CrRejected-AOC | ₹26.0 Cr | L-3 | Rejected-AOC Other than lowest bid |
| 4 | L-4₹26.7 CrRejected-AOC CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹26.7 Cr | L-4 | Rejected-AOC Other than lowest bid |
| 5 | L-5₹27.2 CrRejected-AOC | ₹27.2 Cr | L-5 | Rejected-AOC Other than lowest bid |
Tender Value
₹25.5 Cr
EMD Value
₹15 L
Closing Date
15 Jul 2023, 6:00 pmClosed
CE 31 Srinagar Zone
HQ CE 31 Srinagar Zone Sonwar Srinagar
UPGRADATION OF AVN INFRA PHASE I AT SHARIFABAD DESIGN AND BUILD
2022_MES_555422_3
800137/E8
Open Tender
Civil Works
900 days
Sharifabad
As per tender documents
14 documents required · 14 mandatory
₹3,000
Yes
AGE (I) CIF (K)
₹15 L
Yes
2 Sept 2023
15 Jun 2023
17 Jul 2023
15 Jun 2023
15 Jul 2023
22 Jun 2023
15 Jun 2023 - 19 Jun 2023
Amount
Note: (i) Please refer Schedule 'A' Notes of tender documents. (ii) Unless otherwise specified, earth work and excavation shall be measured and paid separately. (iii) This Schedule 'A' Part-XVIII to XXXIII is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. (iv) In case rate of any item is not quoted by the bidder the rate for the same item will be considered as zero and no claim in this regard at later date will be entertained.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 34
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 37
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 39
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS listed in Schedule 'A' Part-IV brought forward from serial page No. 41
Lump sum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 43
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 44
BLANK
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 48
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTH WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 50
Lump sum price worked out by the contractor for DISPERSAL AREA AND TAXI WAY WORKS listed in Schedule 'A' Part-X brought forward from serial page No. 53
Lump sum price worked out by the contractor for SOLAR WATER HEATING SYSTEM WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 55
Lump sum price worked out by the contractor for ACOUSTICS FOR HANGARETTES WORKS as listed in Schedule 'A' Part-XII brought forward from serial page No. 57
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-XIII brought forward from serial page No. 61
Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS as listed in Schedule 'A' Part-XIV brought forward from serial page No. 62
Lump sum price worked out by the contractor for AIR CONDITIONING WORKS as listed in Schedule 'A' Part-XV brought forward from serial page No. 63
Lump sum price worked out by the contractor for FIRE FIGHTING WORKS as listed in Schedule 'A' Part-XVI brought forward from serial page No. 65
Lump sum price worked out by the contractor for DISMANTLING / DEMOLITION WORKS as listed in Schedule 'A' Part-XVII brought forward from serial page No. 67
BUILDING WORKS BASED ON DESIGN & BUILD (SCHEDULE 'A' Part-XVIII)
(c) Supply and fixing of Motorized sliding door both side electrically operated (also provision of manual operated in case of power shutdown) as directed by manufacture instructions. The wall of the door shall be Pre-painted camouflage pattern galvalume PUF sandwich sheet of thickness 0.50mm thick, yield strength 250 Mpa (External skin of sheet shall be corrugated and inner skin of sheet shall Micro-rib ,Wave or Mini box as directed by Engr-In-Charge), The overall thickness of PUF sandwich sheet shall be 40mm and having density 40 + 2 Kg/cum. The minimum speed of movement of the electrically operated door shall be 10 mtr/min. d) Hangar flooring should be 225mm thick PQC with minimum flexural strength 45 kg/sqcm using non circular synthetic fiber over 400 micron HDPE sheet over 10 mm sand cushion layer, over 150 mm DLC over 150mm thick WMM in two layers (75mm each) over 200 GSB (Granular sub base) Grade-V over compacted sub grade 500mm thick to achieve min K value 5 Kg/Sqcm by replacing existing soil. Cleaning the top surface and applying 1500 micron anti-static EPOXY flooring complete all as specified and directed. (e) The rate is inclusive for providing, aluminum/ wooden/ PVC joinery, venetian blinds in all windows/ ventilator, flooring, External Internal finishes etc complete all as spd and shown in Drg.
(f) Suppy & fixing Bird proof netting shall be HDPP Wire-netting made out of nylon (not recycled) with size of aperture not more than 20 mm & dia of Nylon thread not less than 1.25 mm. Colour shade shall be as approved by GE. Steel wire retainers or other supporting mechanism shall be provided for preventing any sag in Bird proofing net. (g) Excavation of earth work in any type of soil including returning, refilling and removal of surplus soil upto distance exc 50mtr but not exc 500mtr all as directed by AGE (I) CIF (K). (h) Design of EOT Crane electrically operated OH Complete with span up to 50 metre, capacity 5 Ton and 8 metre clear hook height Catwalk of 800 mm width with suitable rallings for 50 mtre length of the hangar in consultation with crane manufacturers for easy access to cranes. Height of the catwalk shall be decided by the PEB designer as per detailed specifications given in BOQ item No. 16.00. Note :- (i) Irrespective of whatever indicated in drawings or specified elsewhere in tender documents, the inner surfaces of all external walls at GF and FF of Hangrettes/Annexes except in toilets shall be provided with wall insulation as specified at Note given after Srl No. 1(A) 18 in Sch of Finishes drawing No. CESZ/WD-206/SF/2022 , Sheet 1/5 and as per detail given in drawing CESZ/WD-206/SF/2022 , Sheet 5/5 and the cost thereof shall be deemded included in quoted lumpsum cost of the building. (ii) However, accoustics of Hangerettes on surfaces of walls/roofs other than mentioned at Note (i) above shall be provided where directed by GE/Engineer in charge as per Sch 'A' Part-XII (Accoustics for Hangerettes works) which shall be measured and paid for separately. (iii) Supply, installation, commissioning and testing of EOT crane shall be measured and paid for separatley against Srl item No, 16 Of BOQ (Sch 'A' Part-XXXI i.e. EOT Crane works)
INTERNAL ELECTRIFICATION WORKS (SCHEDULE 'A' Part-XIX)
Supply & fixing switch piano, flush type, single pole, two way, 6 Amp, 240 volts complete all as specified and directed.
Supply and fixing LED tube light fitting, 4 feet long, 18 watt 220 V AC, box type with driver, holder including LED tube light, connecting up with and including three core flexible copper conductor cable of suitable size from ceiling rose including hanging by chain or hook fitted on two round blocks /fixing arrangement on truss/roof/wall complete all as specified and directed .
Supply and fixing LED tube light fitting, 2 feet long, 10 watt 220 V AC, box type with driver, holder including LED tube light, connecting up with and including three core flexible copper conductor cable of suitable size from ceiling rose including hanging by chain or hook fitted on two round blocks /fixing arrangement on truss/roof/wall complete all as specified and directed.
Supply & fixing LED bulb, 9 watt, 240 volts including driver complete all as specified and directed.
Supply & fixing TV socket, AC, 240 volts including driver complete all as specified and directed.
Supply and fixing vertical sheet metal enclosure, double door, for distribution board, factory made for MCCB DB load link TPN 4 way, 415 volt, 50 Hz, suitable for MCCB as incomer, 4 pole (when MCB's are to be used) with suitable size of bus bar, fixed to wall complete all as specified and directed.
Supply and fixing MCB single pole, 6 - 32 Amp 240 Volt, 50Hz , AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' Curve, 10 KA, breaking capacity and terminal box suitable upto 16 sqmm cable confirming to IS/IEC 60898-I & IS/IEC 60947-2 complete all as specified and directed.
Supply and fixing MCB triple pole, 63 Amp 415 Volt, 50Hz , AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' Curve, 10 KA, breaking capacity and terminal box suitable upto 16 sqmm cable confirming to IS/IEC 60898-I & IS/IEC 60947-2 complete all as specified and directed.
Supply and fixing MCB triple pole, 100 Amp 415 Volt, 50Hz , AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' Curve, 10 KA, breaking capacity and terminal box suitable upto 16 sqmm cable confirming to IS/IEC 60898-I & IS/IEC 60947-2 complete all as specified and directed.
Supply and fixing MCB, TPN, 32 Amp 415 Volt, 50Hz , AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' Curve, 10 KA, breaking capacity and terminal box suitable upto 25 sqmm cable confirming to IS/IEC 60898-I & IS/IEC 60947-2 complete all as specified and directed.
Supply and fixing MCB, TPN, 63 Amp 415 Volt, 50Hz , AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' Curve, 10 KA, breaking capacity and terminal box suitable upto 25 sqmm cable confirming to IS/IEC 60898-I & IS/IEC 60947-2 complete all as specified and directed.
Supply and fixing MCB, TPN, 100 Amp 415 Volt, 50Hz , AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' Curve, 10 KA, breaking capacity and terminal box suitable upto 25 sqmm cable confirming to IS/IEC 60898-I & IS/IEC 60947-2 complete all as specified and directed.
Supply and fixing RCBO, 4 pole, 63 Amp 415 Volt, 50Hz , AC, 10 KA, breaking capacity and terminal box suitable upto 95 sqmm cable confirming to IS:12540 and IEC 61009 complete all as specified and directed.
Supply and fixing RCBO, 4 pole, 32 Amp 415 Volt, 50Hz , AC, 10 KA, breaking capacity and terminal box suitable upto 95 sqmm cable confirming to IS:12540 and IEC 61009 complete all as specified and directed.
Supply and fixing RCBO, SPN, 32 Amp 240 Volt, 50Hz , AC, 10 KA, breaking capacity and terminal box suitable upto 16 sqmm cable confirming to IS:12540 and IEC 61009 complete all as specified and directed.
Supply and fixing MCCB, 4 pole, 125 Amp, 415 Volt, 50Hz , AC, 16 KA, breaking capacity and terminal box suitable upto 95 sqmm cable complete all as specified and directed.
Supply and fixing MCCB, 4 pole, 63 Amp, 230 Volt, 50Hz , AC, 16 KA, breaking capacity and terminal box suitable upto 95 sqmm cable complete all as specified and directed.
Supply, assembling and hanging ceiling fan, 1200mm sweep, AC single phase, 230V, 50 Hz, copper wound ,BEE 5 star rated, aluminium body with aluminium fan blade, making connection with copper conductor cable 3 core 1.5 sqmm, complete alll as specified and directed.
Supply and fixing exhaust fan heavy duty, 300 mm sweep, steel body with blades, frame and louvers, AC supply, single phase 220 volts 50Hz, including nuts and bolts grouted in PCC, connecting up with and including three core flexible copper conductor cable 1.5 sqmm 3 core through flexible conduit from ceiling rose complete all as specified and directed.
Material and labour for sub main wiring with 2 runs of single core FRLS PVC insulated cable multi-stranded copper conductor 2.5 Sqmm for phase and neutral and one run of single core FRLS PVC insulated cable multi-stranded copper conductor 2.5 Sqmm for earth continuity including rigid non metallic PVC conduit not less than 20mm dia with all accessories medium grade ISI marked complete all as specified and directed. Note : 02 runs of PVC cable 2.5 sqmm, 01 run of PVC cable 2.5 sqmm & PVC conduit will be considered as one unit.
Material and labour for sub main wiring with 04 runs of single core FRLS PVC insulated cable multi-stranded copper conductor 16 Sqmm for phase and neutral and one run of single core FRLS PVC insulated cable multi-stranded copper conductor 16 Sqmm for earth continuity including rigid non metallic PVC conduit not less than 25mm dia with all accessories medium grade ISI marked complete all as specified and directed. Note : 4 runs of PVC cable 16 sqmm, 01 run of PVC cable 16 sqmm & PVC conduit will be considered as one unit.
Material and labour for sub main wiring with 04 runs of single core FRLS PVC insulated cable multi-stranded copper conductor 10 Sqmm for phase and neutral and one run of single core FRLS PVC insulated cable multi-stranded copper conductor 10 Sqmm for earth continuity including rigid non metallic PVC conduit not less than 25mm dia with all accessories medium grade ISI marked complete all as specified and directed. Note : 04 runs of PVC cable 10 sqmm, 01 run of PVC cable 10 sqmm & PVC conduit will be considered as one unit.
Material and labour for sub main wiring with 04 runs of single core FRLS PVC insulated cable multi-stranded copper conductor 6 Sqmm for phase and neutral and one run of single core FRLS PVC insulated cable multi-stranded copper conductor 6 Sqmm for earth continuity including rigid non metallic PVC conduit not less than 25mm dia with all accessories medium grade ISI marked complete all as specified and directed. Note : 04 runs of PVC cable 6 sqmm, 01 run of PVC cable 6 sqmm & PVC conduit will be considered as one unit.
Material and labour for sub main wiring with 04 runs of single core FRLS PVC insulated cable multi-stranded copper conductor 4 Sqmm for phase and neutral and one run of single core FRLS PVC insulated cable multi-stranded copper conductor 4 Sqmm for earth continuity including rigid non metallic PVC conduit not less than 25mm dia with all accessories medium grade ISI marked complete all as specified and directed. Note : 04 runs of PVC cable 4 sqmm, 01 run of PVC cable 4 sqmm & PVC conduit will be considered as one unit.
Material and labour for sub main wiring with 02 runs of single core FRLS PVC insulated cable multi-stranded copper conductor 10 Sqmm for phase and neutral and one run of single core FRLS PVC insulated cable multi-stranded copper conductor 10 Sqmm for earth continuity including rigid non metallic PVC conduit not less than 25mm dia with all accessories medium grade ISI marked complete all as specified and directed. Note : 02 runs of PVC cable 10 sqmm, 01 run of PVC cable 10 sqmm & PVC conduit will be considered as one unit.
Supply and fixing telephone socket AC 230 volts complete all as specified and directed.
INTERNAL ELECTRIFICATION (HIGHBAY) WORKS (SCHEDULE 'A' Part-XX)
Supply and fixing LED Highbay Light fitting 200 watt saucer next generation highbay ADG series, Energy saving, environment friendly and robust highbay LED with PDC housing suitable for ceiling (surface / suspended) mounting with system efficiency upto 150 lumen / watt for roof with hanging arrangement including connecting with driver 1.5 sqmm 3 core flexible copper conductor cable complete all as specified and directed.
Supply and fixing Three phase industrial interlocking socket 32 Amp 3P+N+E, IP 67 complete all as specified and directed.
Supply and fixing twin aviation light, die cast aluminium housing with red polycarbonate dome enclosure, lamp type LED, lighting type LBD, super flex 5mm 302 Nos LBD incorporated, protection - IP, nominal voltage - 240 V, operational voltage 100 - 270 V, main current - 80 MA, releasing - optional, integral driver, protection against short circuit and surge with all arrangements for fixing at top of Hangar complete all as specified and directed.
Supply and fixing wall mounted air circulation fan 230 volts, 50 HZ, RPM 1200, copper winding, single phase oscillating 750 mm sweep heavy duty made out of sturdy engineering material including connection wire of 1.5 sqmm 3 core from ceilling rose to fan in flexible conduit complete all as specified and directed..
SEWAGE DISPOSAL WORKS (SCHEDULE 'A' Part-XXI)
Material and labour for Elastic Biodigestor LLDPE commercial grade Septic tank for 25 users, designed to carry sewage and sludge water including excavation & earth work in any type of soil, 150mm thick PCC 1:4:8 in foundation, vent shaft, connection complete all as specified and directed.
M&L for construction of Soakage well 1.20m dia and 3.00m deep (Depth 3.00m from inlet pipe and 45cm from Ground level to inlet pipe) including excavation & earth work in any type of soil, foundation in PCC 1:4:8 type D-2 using graded store aggregates, brick work (honey combed) in cement mortar (1:4), top ring of M-30 Design mix concrete including intercepting chamber and screen chamber made of Brick masonary in cement mortar 1:4, RCC M-30 Design mix cover slab, reinforced with TMT bars, steel plate manhole cover factory made ISI marked conforming to IS-12592 with angle iron frame, brick bats filling, complete all as specified and shown on drawing No. CESZ/TD-1078/2011.
ROAD AND CULVERT WORKS (SCHEDULE 'A' Part-XXII)
M & L for painting lines, dashes, arrows , letters etc on road pavements and the like exe 10cm wide using thermoplastic road marking paint with 8% glass beads applied hot using special applicator machine with heating arrangement upto 160 degree centrigade complete all as specified and directed. Note:- The painted surface shall stand out boldly and solidly without showing signs of brush marks or surface underneath. If necessary, the surface shall be re-painted untill the desired result is obtained. (For Road and Dispersal Area & Taxi Way)
M & L for concrete bed to drain pipes 600 mm bore in PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested including forming cradles complete all as specified and directed. Note:- (a) The rates include for any necessary shuttering and supports to concrete and for laying beds to falls. (b) Excavation, returning filling etc. in trenches shall be measured separately.
EXTERNAL WATER SUPPLY WORKS (SCHEDULE 'A' Part-XXIII)
M&L for cutting of existing GI pipe 50mm bore and making new connection including inserting Tee of size 50mmx50mmx20mm including necessary excavation & earth work complete all as specified and directed. Note:- The cost of fittings such as Tee, nipple, union, socket etc shall be deemed included in ythe unit rate. (For Water Supply and Solar Water Heating System works)
DISPERSAL AREA AND TAXI WAY WORKS (SCHEDULE 'A' Part-XXIV)
M&L for Soil stabilzation of 500 mm thick sub grade soil filled in layers with approved gravelly soil of classification (GW/GP/GW-GM, GP-GM conforming to MoRTH specification Para 305) by uniform mixing of cement OPC 43 grade/lime/other additive @ 5% of cement by weight of soil (Percentage of cement/additives for estimation purposes only. Type of additive and percentage required for blending to be given in mix design). Item will include pulverization of soil, spreading of additive, blending mix by tractor towed rotovator, addition of water/drying of mix to required moisture content and compaction using suitable vibratory roller to achieve proctor density of 98% maximum dry density including rough excavation n exc 1.5 mtr depth and removing excavated soil upto 15 Km and depositing where directed complete all as specified and directed. NOTE :- Provisions of IRC SP:89-2010 and TI 09/2018 be referred to for this item.
Provding and laying Dry Lean Concrete (DLC) 150 mm thick having compressive strength not less than 7 Mpa at 7 days for each consecutive group of 5 cubes. Individual strength of each cube must not be less than 5.5 Mpa at 7 days (Para 4.1 IRC :SP: 49 : 2014). (Grading and other parameters as per Table 1 IRC :SP:49-14). Minimum Cement content must not be less than 140 Kg/Cum (Para 4.2 IRC :SP: 49 : 2014) Mixed in batching plant, transported to site and laid by Sensor Paver including spreading and compacting using double drum smooth wheel roller 80-100 KN of Static/Vibratory capacity to achieve proctor density of 98% maximum dry density including neccessary formwork, finishing etc. complete all as specified and directed.
M&L for 225mm thick Pavement Quality Concrete of minimum field flexural strength of 4.5 Mpa lower control limit (LCL) at 28 days in Pavement Slab using min 360 Kg of Cement per Cum as per IRC 44 (Only 43 grade OPC shall be used ) Mixed with non circular synthetic fibre by mechanical means at the rate of 0.25% by weight of cement per Cum of PQC; laid, spread and compacted with slip-form paver of minimum 7.50 metre width. Curing and tinng shall be by mechanical equipment, Texuring Cum Curing Machine (TCM), Max size of aggregate in PQC shall be 31.5mm and gradation as per IRC 44-2017 complete all as specified and directed. Note:- While laying 225mm thick PQC (VDF) vacuum dewatered flooring method shall be used.
Supply only polyester triangular fibres as secondary reinforcement in all types of concrete confirming all the criteria as per IS-16481:2016 having cut length 12 - 18 mm with fibre diameter 15 - 40 micron and non circular in cross section with minimum tensile strength 300 Mpa having specific gravity 1.34 to 1.39 and minimum melting temperature 250°C etc complete all as specified and directed.
SOLAR WATER HEATING SYSTEM WORKS (SCHEDULE 'A' Part-XXV)
Supply, installation, testing and commissioning of solar water heating system of capacity 500 lItres made out of stainless steel puf insulated outer shell made out of supper finished stainless steel with electric back up of suitable watage, thermostat with necessary wiring and suitable in coming cables, flat plate collectors for cloudy whether ISI marked suitable for operation in HAA and sub zero temp. complete all as specified ands directed. Note:- Water tank, pipes & fittings shall be measured and paid for separately.
EXTERNAL ELECTRIFICATION WORKS (SCHEDULE 'A' Part-XXVI)
Supply and installation of three phase low voltage transformer isolation (Isolation type having capacity of 630 KVA (near available size) for frequency 50Hz vaccum pressurised impreganation with epoxy resign class H of copper winding with protection degree IP00 complete all as specified and directed.
Material & labour for switch air break gang operated, triple pole, mounted on 9 insulators complete, mechanically operated, vertical operation by copper blade type contact mounted on post insulator and GI steel frame with new operating mechanism worked from ground level with GI pipe of 25mm medium grade, for current rating upto 1000 Amp, 11000 Volts complete with locking arrangements MS clamps, bolts, nuts and washers etc. including fuse barrels of required capacity to suite the load at site including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.
Material & labour for switch air break gang operated out door HT 11 KV triple pole mechanically operated mounted on HT insulators (12 Nos insulators) type and MS galvanised steel frame with operating mechanism worked from ground level including operating rod of GI pipe of 25 mm bore with handle for current rating 200 Amps, 11000 volts including suitable DO Fuse complete with locking arrangements MS clamps, bolts, nuts and washers etc. including fuse barrels of required capacity to suite the load at site including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mat, 2.00m x 1.00m size, 2.5mm thick, for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes complete all as specified and as directed.
Supply and erecting Steel tubular swaged poles complete with MS base plate continuously welded to pole, finial taper plug, bolts, nuts & screws as specified type 410 SP- 55 (11 metres long) including two coat of black bituminous paint internally throughout and externally upto embedded portion and including applying two coats of synthetic enamel paint over a coat of red oxide primer with black and yellow strip of 30 cm each upto 1.5 m height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface after errection in position including preparation of surface, complete all as specified and directed. ( Note:- Necessary earth work , PCC coping will be measured and paid for separately under respective item.
Supplying, laying, jointing and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 400 Sqmm single core confirming to IS: 7098-1985 (Part-I) laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
S&F Cable jointing kit for 11 KV grade cable for indoor/outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for single core XLPE armoured aluminium conductor cable of size 400 sqmm complete all as per specified and directed
Supply, installation, testing & commissioning of CPRI approved LT panel indoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet 2.00 mm thickness of suitable size with 450 mm depth with base ISMB 100 mm and Angle Iron frame (50x50x5mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms grouted in PCC 1:3:6 type C-2, cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front & rear side including locking arrangement duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc. Following shall deemed to be included in the cost of panel:-
Material and labour for bus bar chamber, 200 Amp rating, 3 phase, 440 Volts, 50 Hz, size 60cm x 60cm x 45cm totally enclosed, made out of 3.15mm thick sheet, frame of angle iron 50mmx50mmx6mm suitable for operation of system with hinged doors on one side with handles, locking arrangement with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator complete all as specified and directed.
Supplying, laying, jointing and testing XLPE insulated, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, , 1100 volts grade, with aluminium conductor, cross sectional area 4 Sqmm 3 core confirming to IS: 7098-1985 (Part-I) laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supplying, laying, jointing and testing XLPE insulated, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, 1100 volts grade, with aluminium conductor, cross sectional area, 6 Sqmm 3 core confirming to IS: 7098-1985 (Part-I) laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply and fixing LED street light fitting 36 Watt, 230 volt, AC outdoor type, with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete incl Bracket made out of GI light grade pipe of 32 mm dia 1.5 mtr long bent to an angle of 120 degree fixed with 02 Nos MS clamp 25mm x 4mm and 04 sets of nuts, bolts and washers and junction box of mininmum size 168mm x 253mm x 115mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts and arrangement for incoming and out going cable / wire complete comprising with the followings :- (a) Bus bar with four aluminium strips 60 Amps capacity insulated with insulators, incl colour coding, including control wiring from bus bar to MCB (b) MCB SPN 6 Amps - 01 No. incl copper connection from junction box complete all as specified and directed.
Supply & Fixing made epoxy polyester powder coated distribution board 4 way VTPN DB-507745 with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box fcomplete all as specified and directed. NOTE :- (a) MCCB /MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed included in item rate
Supply and laying in trenches sub class 'B' bricks, old size, laid dry flat on sand cushioning for protection of cable abutted each other complete all as specified and directed. Note: Sand cushioning shall be measured and paid for separately.
M & L for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed. Note: (i) Measurement shall be taken only after punning down sand cushioning.
Material and labour for Sub main wiring of two single core PVC insulated and unsheathed cable with 10 sqmm FRLS multi-stranded copper conductor drawing in Rigid steel conduit ,welded, stove enamelled, black 25mm dia including junction box, with cover and outlets. 02 runs of IC x 10.00 sqmm (Main Cable and neutral) and one run of IC x 10 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete all as specified and directed. Note : 02 runs of PVC cable 10 sqmm, 01 run of PVC cable 10 sqmm & PVC conduit will be considered as one unit.
LIGHTNING PROTECTION WORKS (SCHEDULE 'A' Part-XXVII)
Supply and fixing epoxy electric insulators dough moulded compound 40mm for mounting earth conductor complete all as specified and directed.
AIR CONDITIONING WORKS (SCHEDULE 'A' Part-XXVIII)
Supply, installation and testing of autometic voltage stabilizer 5 KVA 230 Volts, 50Hz, single phase suitable for input voltage 90V to 260V, out put voltage 230V +/-2.5%, Copper wound complete all as specified and directed.
Supply, installation and testing of autometic voltage stabilizer 4 KVA 230 Volts, 50Hz, single phase suitable for input voltage 90V to 260V, out put voltage 230V +/-2.5%, Copper wound complete all as specified and directed.
Supply, installation and testing of voltage stablizer 2 KVA for automatic operation, single phase naturaly air cooled indoor type and designed for input variation between 90V to 250 v with out put volatge stabilized at 230 v with accuracy of+/- 2.5% copper wound complete all as specified and directed.
FIRE FIGHTING WORKS (SCHEDULE 'A' Part-XXIX)
Supply, installation, testing and commissioning of fire centrifugal pump set, horizontal split casing type, electric motor driven, 2850 LPM operating on 70 M overall head, high tensile shaft head with CI casing, bronze impeller coupled with electric motor of capacity 100 HP along with foundation channel, foundation bolts, vibration pads suitable for push button/manual operation complete including all accessories such as standard coupling, coupling guard, including following fittings with electric and water connection and testing complete, all as specified and as directed :- (a) Hour Meter - 01 No. (b) Pressure gauge 0-15 Kg / Sq cm range 80 mm dia on delivery & suction line with all fittings - 02 Nos. NOTE : The rates quoted shall include for construction of the required foundation for the pump set. The design of the foundation shall be strictly as per the manufacturer's instructions.
Supply, installation, testing and commissioning of jockey pump, horizontal, centrifugal type of rated capacity with control panel with requisite digital meters and all accessories to maintain the pressure in entire system suitable HP / Discharge cap not less than 180 LPM at 70 mtrs head, volute type with cast iron casing, bronze impeller coupled to a suitable size squirrel cage induction motor, totally enclosed 415 volt, 3 phase, 50 Hz including all accessories such as standard coupling, coupling guard, common base plate, foundation bolts, nuts, washers, pressure gauge 0 to 15 Kg/Sq cm range 80 mm dia on delivery & suction lines including nuts, bolts, washers, electric and water supply connection and testing complete all as specified and directed. NOTE : The rates quoted shall include for construction of the required foundation for the pump set. The design of the foundation shall be strictly as per the manufacturer's instructions.
M&L for joint for DI pipe flanged end of class K-9 using all accessories like MS bolts nuts and rubber gasket 3.0 mm thick for pipe of size 150 mm bore, complete all as specified and directed.
M&L for joint for DI pipe flanged end of class K-9 using all accessories like MS bolts nuts and rubber gasket 3.0 mm thick for pipe of size 100 mm bore, complete all as specified and directed.
M&L for joint for DI pipe flanged end of class K-9 using all accessories like MS bolts nuts and rubber gasket 3.0 mm thick for pipe of size 80 mm bore, complete all as specified and directed.
Supply and fixing Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet with all accessories complete all as specified and directed.
Supply, fixing, erection and installation of Fire Hose Cabinet to be mounted externally near the Hydrant Post, fabricated from 16 SWG MS Steel of appox size 750 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in-built in the box, suitable to accomodate one hydrant valve, one branch nozzle and two 30 mtrs hose, weather proof, Finished with P.O. fire red color and mounted on masonry platform complete all as specified and directed.
Supply and fixing hose pipe, 63 mm dia, 15 metre long, Reinforced Rubber Lined (RRL) Type 'A', ISI marked (IS-636), woven jacketed, tested to bursting pressure 32 Kg/Sq cm with and including gun metal male & female instantaneous type coupling approved by fire authority, ISI marked (IS:636-1988), machine wound with GI wire with the pipe complete in all respects, complete all as specified and directed.
Supply and fixing hose pipe, 63 mm dia, 30 metre long, Reinforced Rubber Lined (RRL) Type 'A', ISI marked (IS-636), woven jacketed, tested to bursting pressure 32 Kg/Sq cm with and including gun metal male & female instantaneous type coupling approved by fire authority, ISI marked (IS:636-1988), machine wound with GI wire with the pipe complete in all respects, complete all as specified and directed.
Supply and fixing standard short size gun metal branch pipe with gunmetal nozzle 20 mm dia outlet with standard male instantaneous spring lock type 63mm dia coupling (Branch pipe and nozzle shall be ISI marked (with IS : 903-1985) complete all as specified and directed.
Providing & fixing swinging type first aid hose reel in red colour with 30 metre long and 20 mm dia heavy duty rubber water hose, terminating with Gun Metal coupling & nozzle of 5mm outlet with shut off valve confirming to IS 8090 - 1976 complete with drum and brackets for fixing on wall, bolts & nuts conforming to IS:884-1969, complete all as specified and directed.
Supply & fixing fire hydrant landing valve type 'A' (single head outlet) of 63 mm dia conforming to IS:5290 made of stainless steel (SS 316), having 100 mm flanged inlet and one No. 63 mm female instantaneous outlets CI hand wheeels for hydrant operation, and gun metal blank caps with chain, body duly painted with 2 coats of paint. HP tested to 21 kgf/sqcm (body) and 14 kgf/sqcm (Seat) flow 1800 LPM (min) at 7 kgf/sqcm complete all as specified and directed.
Supply & fixing fire hydrant landing valve type 'B' (double head outlet) of 63 mm dia conforming to IS:5290 made of stainless steel (SS 316), having 100 mm flanged inlet and one No. 63 mm female instantaneous outlets CI hand wheeels for hydrant operation, and gun metal blank caps with chain, body duly painted with 2 coats of paint. HP tested to 21 kgf/sqcm (body) and 14 kgf/sqcm (Seat) flow 1800 LPM (min) at 7 kgf/sqcm complete all as specified and directed.
Supply & fixing 150mm bore hand operated CI butterfly valve flanged type, 16 Kg/sqmm pressure lever opearted, cast iron handle, PN 16 EPDM / Nitrile body liner, stainless steel Disc, complete with nut, bolts and washers complete all as specified and directed.
Supply & fixing Dual plates CI wafer type check valve, 150 mm bore tested to pressure of 15Kg/ Sqcm, Design-API 594, Wall Thickness-API 594 Class 150, BS 1452 Gr. 200, Plates-A217 Gr. CA15, Seat-EPDM, Spring-SS316, Wafer Ends complete all as specified and directed.
Supply & fixing Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20 mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple, tees, elbows and all accessories complete all as specified and directed.
Supply & fixing automatic air release valve 50mm dia ductile cast iron epoxy powder coated, brass/ elastomer with stainless steel connecting nipple, stainless steel bolts, nuts and washers suitable for domestic water with 50mm gun metal stop valve complete all as specified and directed.
Supply & fixing Mild Steel class 'C' diesel pump exhaust pipe 150mm dia with one layer of 10mm thick asbestos rope insulation and including all fittings clamp/ structural steel supports complete all as specified and directed.
Supply & fixing pressure gauge,100 mm burdon tube / bellow type of working range 0 - 25 Kg/Sqcm with control valve and necessary connection complete all as specified and directed.
Supply & fixing Cast Iron Air Valves with two air Outlets, 150 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed.
Supply & fixing electric motor siren conforming to IS 1941 suitable for three phase 415 V supply with motor not exceeding 3.75 KW power and able to deliver 143 db noise level complete all as specified and directed.
Supply, fixing, commissioning and testing of MS pipe, 50 mm dia flanged type NB heavy duty for multi storied building including all pipe fittings like flanges, elbows, Tee's, reducers, nuts, bolts, washers, MS channel/angle etc including connected welding works and painting of pipelines with two coat of synthetic enamel PO red, over coat of zinc chromate primer complete all as specified and directed.
Supply, fixing, commissioning and testing of MS pipe, 100 mm dia flanged type NB heavy duty for multi storied building including all pipe fittings like flanges, elbows, Tee's, reducers, nuts, bolts, washers, MS channel/angle etc including connected welding works and painting of pipelines with two coat of synthetic enamel PO red, over coat of zinc chromate primer complete all as specified and directed.
Supply, fixing, commissioning and testing of MS pipe, 150 mm dia flanged type NB heavy duty for multi storied building including all pipe fittings like flanges, elbows, Tee's, reducers, nuts, bolts, washers, MS channel/angle etc including connected welding works and painting of pipelines with two coat of synthetic enamel PO red, over coat of zinc chromate primer complete all as specified and directed.
Supply, laying, jointing & testing ERW pipe 300 mm nominal bore, heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer (For Header) complete all as specified and directed.
Supply, laying, jointing & testing ERW pipe 150 mm nominal bore, heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer (For Header) complete all as specified and directed.
Supply, laying, jointing & testing ERW pipe 100 mm nominal bore, heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer (For Header) complete all as specified and directed.
Supply, laying, jointing & testing ERW pipe 50 mm nominal bore, heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer (For Header) complete all as specified and directed.
Supply and fixing gun-metal two way collecting head with 63mm dia instantaneous type inlet and 100mm dia flanged outlet with built-in check valve, ISI marked (IS : 904) complete with bolts, nuts and rubber insertions including necessary supports complete in all respect for fire brigade connection to underground tanks and wet risers complete all as specified and directed.
Material and labour for construction of brick valve pit of size 120cmx120cmx120cm (internal dimensions) including all excavation and earth work in any type of soil, returning filling in and disposal of soil to a distance not exceeding 50m and depositing where directed to a distance n exc 50m, PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, PCC as in coping in 1:2:4 type B-1 using 20mm graded crushed stone aggregate incl necessary form work, brick masonary in cement mortar 1:4 using sub class 'B' bricks old size, rendering internally with 12mm thick cement mortar 1:4 finihsed even and fair and externally pointed flush upto GL in the same mortar as the work proceeds and 15mm thick cement plaster in cement mortar 1:4 on external surfaces above GL, valve pit cover with MS sheet cover 3.15mm thick welded to mild steel angle iron 40mmx40mmx6mm frame with handle and locking arrangement, painting all the exposed surfaces of steel with two coats of synthetic enamel paint over a coat of primer and the portion embedded in concrete with two coats of black bituminous paint complete all as specified and directed.
Material and labour for Wiring of starter and motor with single core FRLS multistranded PVC unsheathed cable 1100 volt single core copper conductor 25 sqmm with suitable size of PVC conduit complete all as specified and directed.
Supply, installation, testing and commissioning of LT Panel board, cubicle type size 1.5 M x1.2 M x 0.5 M, floor mounted, fabricated out of 2 mm thick CRCA sheet and 50 mm x 50 mm x 6 mm MS angle iron frame work, front and back door shutters with locking arrangement and suitable holes at the rear of the bottom of the cubicle including metallic cable glands of suitable for incoming and outgoing cables and individual shutters fitted with hinges with door gasket for each feeder separately, including auto ON-OFF system for 1 No. main pumping sets and 01 Nos jockey pumping set including following fittings :- (a) Bus bar chamber with 4 Nos copper bus bar of size 32 mm x 6 mm fixed on porcelain insulators of suitable size insulated with PVC insulation tape as per colour code. (b) MCCB 250 Amps, 4 pole, 415 volts, 3 phase, 50 Hz with adjustable current 70%-100% and breaking capacity 25 KA conforming to IS-13947-II / IEC : 947 - 1 No (For incoming supply). (c ) MCCB 160 Amp 4 Pole 415 volts, 3 phase, 50 Hz with adjustable current 70%-100% and breaking capacity 25 KA conforming to IS-13947-II / IEC : 947 - 1 No ( for electric driven main pump) (d) MCCB 100 Amp TP, 25 KA 4 pole, 415 volts, 3 phase, 50 Hz with adjustable current 70%-100% and breaking capacity 25 KA conforming to IS-13947-II / IEC : 947 - 1 No ( for Jockey pump) (e) MCB 20 Amp SPN 230 Volts 10 KA - 2 Nos ( for other outgoings)
Supply and fix Fire alarm repeater panel complying with BS EN 54 two loop panel of capacity from 99 detectors & 99 modules upto 200 detector complete all as specified and directed.
Supply and fix Addressable manual call point break glass type with alarm LED complete all as specified and directed.
Supply, laying & testing electric control cable, PVC insulated, PVC sheathed ,galvanized steel strip or wire armoured, (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 2 core, 1100 Volts grade FRLS complete all as specified and directed.
Supply and fixing Stove enamelled, black, rigid steel conduit, welded 25 mm dia including all fittings & accessories on surface or cable tray etc complete all as specified and directed.
Supply and laying standard fireman's axe with heavy insulated rubber handle complete all as specified and directed.
Supply and hanging/placing in position 4.5 Kg capacity carbon-di-oxide (CO2) type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge, internal discharge tube, 30cm long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with initial charge complete all as specified and directed. (Note : - The body of fire extinguisher shall be CCE approved with IS:2878 marking and showing the filling/validity date).
Supply and hanging/placing in position 9 litres capacity water gas (stored pressure) type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge, internal discharge tube, 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 6234 finished externally with red enamel paint and fixed to wall with brackets complete with initial charge complete all as specified and directed. (Note : - The body of fire extinguisher shall be CCE approved with IS:2878 marking and showing the filling/validity date).
Supply and hanging/placing in position ISI marked (IS:10201) protable fire extinguisher Mech Foam type capacity 9 litres with gun-metal cap and nozzle complete in all respects including initial fill and wall suspension complete all as specified and directed.
Supply and hanging/placing in position ISI marked (IS:2171) Dry Chemical powder type fire extinguisher capacity 9 Kg with gumnetal cap and nozzle and nozzle delivery hose, ISI refill and gas cartridge, wall/ trolley mounted and complete in all respects including initial fill complete all as specified and directed.
Supply and hanging/placing in position ISI marked (IS:2878) Fire and wall suspension bracket Extinguisher, Trolley mounted carbondioxide type capacity 22.5 Kg Flat base including valve, discharge of not less than 10mm dia 1m long complete in all respects including wheeled trolley, carrying handle and initial to a filling ratio of not more than 0.667 complete all as specified and directed.
Supply and hanging/placing in position ISI marked (IS 13386) Mechanical Foam type fire extinguisher capacity 45 litres with gun-metal cap and nozzle, delivery house, ISI refill and gas cartridge, trolley mounted and complete in all respects including initial fill complete all as specified and directed.
PNEUMATIC COMPRESSOR WORKS (SCHEDULE 'A' Part-XXX)
Supply and install Air Compressor with 300 ltrs litre receiver with motor and starter suitable for PD CFM 30, Max working pressure 290 psi (20.40 kg/sqcm) with following specifications:- (1).TYPE- Reciprocating air cooled (2).Bore x Stroke-5" & 2.75" x 3.5"(Dobule) (3).Regulation-automatic start stop control (ASSC) (4).Drive type-v belt drive (5).oil lubrication-splash lubrication (6).Required HP-10HP (7) NO of stages-TWO (8) NO of pistons-TWO (9).NO of cylinder-TWO (10) Piston Displacement -30 CFM (11) Maximum working pressure-290psig./20.40kg/cm2 (12).valve system-concentric ring valve type (13).Receiver -Horizontal of 300 liters (14) Electric motor -10.0HP With IE2 Specification (15) Standard Accessories - Suction Air filter, safety valve, service valve, Non return valve, drain valve, pressure gauge, V-Belts and belt guard, pressure switch.complete all as specified and as directed.
Suippy and fixing galvanisd steel Pipes 80mm bore, Heavy duty class, through welding joint and tested on 8 bar pressure for pneumatic line for air compressure complete all as specified and directed. Note:- Fittings such as Bends, Elbow, Union, socket and short pieces nipples shall be measured and paid for separately
Suippy and fixing galvanisd steel Pipes 25mm bore, Heavy duty class, through welding joint and tested on 8 bar pressure for pneumatic line for air compressure complete all as specified and directed. Note:- Fittings such as Bends, Elbow, Union, socket and short pieces nipples shall be measured and paid for separately
Suippy and fixing galvanised steel elbow, 80mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Tee, 80mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Socket, 80mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Union, 80mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Nipple, 80mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Elbow, 25mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Tee, 25mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Socket, 25mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Union, 25mm bore, heavy duty complete all as specified and directed.
Suippy and fixing galvanised steel Nipple, 25mm bore, heavy duty complete all as specified and directed.
Suippy and fixing air control brass valve, suitable for GI pipe 25mm bore heavy duty complete all as specified and directed.
Suippy and fixing air control brass valve, suitable for GI pipe 80mm bore heavy duty complete all as specified and directed.
EOT CRANE WORKS (SCHEDULE 'A' Part-XXXI)
Supply, Fixing, testing and commissioning EOT Crane electrically operated OH Complete with span up to 50 metre, of capacity 5 Ton (8 metre Hook height) operted with pendent push button type (class-II) medium duty Double grider including GI shrouded bus bar of capacity 80 Amps, 3 Phase, all and 50 RM length with all accessories and current collector (4 Nos) as directed by Engineer-In-Charge with following :- (A) Equipment :- 5Ton cap elect operated double girder EOT Crane. (B) Capacity (S.W.L)/TEST Load :- 5T/125% (C) Span :-50 Metre (D) Height of lift :- 8 metre (E) Type :- Double Girder (F) Locations :- Indoor (G) Wheel Base :- 6 metre (H) Preferred speed :-All speed variation will be +-10% Main-Hoisting ;-3.5 meter per minute AUX, Hoist:-NA, C.T. :-15 Meter per minute, L.T:-15 Metre per minute (J) Electric motor :- All motors shall be crane duty(s4),40% CDF,150 START/hour, IP-5 with class F Insulation. Main-Hoisting :-5HP X1440 RPM-1 NO, Squirrel cage with VFD C.T.:-0.75HPX1440RPM-1NO. Squirrel cage with VFD L.T:-3HPX 1440 RPM-2NOs, Squirrel cage with VFD
(K) Breaks :- All breaks are automaticcally released when the motor circuit is on and is applied the motor circuit is off. Main-Hoisting :-Electro magnetic Disc type. C.T.:-Electro magnetic Disc type L.T.;-Electro magnetic Disc type (L) Wheels :- The wheel of the trolly and the end carriage shall be forged steel CN 55 AND MIN 75 ( EN-9) duly spin hardened to 300BHN Materials.Double flanged straight Tread type fitted with antifriction bearings with 'L' TYPE BEARING Housing for the ease of maintenance. MAIN HOIST;-12mm X 4 FALL (M) Wire Rope :- The make of wire rope will be used USHA-MARTIN (N) Total Connected load :-11.75HP (O) Operation :-Pendent by push button operated type (P) Crane Weight :- Approx.51 ton (NOTE;- Crane weight is givien for structure design purpose only. It has no relation with price) (Q) Wheel load/with impact;-14.5/15 ton
GENERAL TECHNICAL SPECIFICATIONS 1. Codes and Standard :- IS 800 : Code of practice for general construction in steel , IS 807: Code of Practice for Design, Erection and testing (Structur Portion) of Cranes and Hoists, IS 3177 : Code of Practice for Electirc Overhead Travelling Cranes and Grantry Cranes other than Steel Work Cranes 2. Construction of crane End Carriages :- The End Carriages are welded construction type and fabricated from plates or Std. section type constructions. Bridge Griders : The girder/s is/are of plate fabricated box type construticon design to sustain all stresses arising due to vertical & lateral, forces with impact to which they are subjected. The maxumum deflection of the main girder is limited to 1/750 the span of live loads including the weight of the trolley or hoist. (for small span standard i beam will i used instad of p;ate fabricated girder] End Stopper : Stell end stoppers are provided on either side of the bring to limit the motion of the trolley. Alll the buffers will employ springs for shack absorption. Steel: Steel confirming to IS -2062 or equivalent is used in the manufacturing of the main load bearing.
3. LT Drive System :- Twin drive type. 4. Gear boxes:- All gearboxes which are used in Hoisting, L.T and C.T are helical type with M.S Fabricated Housing, Pinions and output shaft are supported on antifriction type roller/Bll bearings. All Gears and Pinions are of En-19/En-9 materials precision machined and teeth cutting by hobbing machine duly hardened to with stand the heavy loads. 5. Rope Drum:- The rope drum is of mild steel fabricated consturciton having right and left hand spiral grooves machined to suit the histing ropes. The durm is of su ch length that there is not more than one layer when rope is full wound. 6. Bottom block :- Assemble consisting of forged steel hook single shank type as per IS-3815 mounted on thrust Ball Bearings, with required diameter rope sheave and hook plates made out of steel. 7. Wheels:- The wheel of the trolley & the end carriage will be used forged stell confroming to IS-2707 GR .II duty spin hardened to 300 BHN or steel cast EN-9, material ,double flanged straight tread type fitted with antifriction type bearings monted on section type bearing housing easy to maintenance.
15. Push Button:- Movable pendent will be provided for floor operated cranes with separate cable track system. Pendent push button hanging with chain or wire rope 16. Electric Cables:- Flexible Copper Cable of Polycab/RR Kabel/KEI 17. Cross Traverse Cable:- Cable Gestoon along span of Crane. (Long travel in scope of purchaser) 18. Limit Switches:- One numbers geared type rotary limit switch of reputed make is provided to prevent over lowering & over hoisting. And two nos, two lever type limit switche shall be provided for L.T & C.T Motion. 19. Rubber Buffer :- 8 Nos (4+4) Rubber buffers are provided for extra protection against collision in case of limit swithch failure. 20. Ladder with wheels:- Inverted 'V' shaped MS ladder with wheels shall be supplied for mobility inside hangars inverted V shaped having stairs on both the sup legs with a platform at the top with adjustable height upto 10 mtrs.
DG SET WORKS (SCHEDULE 'A' Part-XXXII)
Supply, Installation, testing and commissioning of silent type Diesel engine driven generation set with Goveming class G2 incl sound reducing canopy (sound level not more than 75 db at a distance of 1 mtr) 14 guage as per guideline issued by Central pollution conntrol board 415 volts, 3 phase, 50 Hz supply complete with panel for automatic startinng on main failre control panel suitable for giving an output of 630 KVA after considering derating fator at 1600 mettre altitude above mean sea level and capable of operating between temperature range (-20) degree C to (+40) degree C (at Sharifabad area (Srinagar) of J & K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on Antivibration pads on foundation as recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and viceversa self starter with batteries, Turbocharger, water cooler & comprising all standard fitings, fixtures & all piping etc as below:- (a) Alternator : Directly coupled with Enginne and suitable to produce 415 vlots, 3 phase 4 wire system, 50 Hz 0.8 P@ 1500 RPM of capacity 630 KVA all as per as per IS: 13364 and up to date amendments with H class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed.
(b) Engine; Water cooled Diesel Engine (CPCB Norms Compliance) developing 860 BHP or as recommended by the manufactrer for 1600 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (fouundation design as per OEM), as per IS:10001/10002, coupled directly throuugh flexible couling, multi cylinder four stroke, cold strarting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufactrer recommendation, fuel lines, exhaust pipe duly insulated with asbestoos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold strat kit etc all as specified and directed. (c) Canopy: Canopy enclosure shall be powder coated and fabricated after passing through seven tank processes 16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arragement. The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant/ non igniting foam conforming to BIS 7888/BS 4375 to prevent excess heat radiation onn the engine and sage for operator. Absorption type non-resistance Residential Silencer shall be provided to suppress exhaust noise form the enginne.
(d) Alignment and Fuel Tank ; Alternator and Enginne aligned onn a common 14 SWG RCA MS base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame. (e) Generating Panel: DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer specifications. Note :- Capacity of alteranator at 1600 meters altitude 630 KVA, AC 3 Phase, 415 volts, 50 Hz and as recommended by the manufacturer for above sized motor. (f) PCC platform : As per manufacturer design. Note:- (i) Engine shall be designed keeping in consideration of de-rating fator for 1600 meters altitute (ii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep/authorises agent/sister concern etc. (iii) Installation, testing and commissioning of Gen Seet shall be done in presence of manufacturer's Engineer and not by any authorised person. (iv) DG Set shall be tested for 12 Hrs continuously as following.:- No Load =30 Minutes, 25 % of Rated load= 1 Hr 50% of rated load=1Hr, 75% of Rated load = 1 Hr, Full load =2Hr,,110% onrated Load =1Hr, Full load =2Hr,75& of Rated load=1Hr, 50% of Rated load =1Hr, 25% of Rated load=1Hr, No Load=30 Minutes. (v) All testing materals and fuel shall be provided by the contractor
EARTHING WORKS (SCHEDULE 'A' Part-XXXIII)
Supply & laying Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25mm x 6mm copper strip complete all as sepcified and directed. Note:- Jointing shall be done by overlapping and tightning with 2 sets of brass nuts, bolts and spring washers spaced at 50mm
Supply & laying Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25mm x 5mm copper strip complete all as sepcified and directed. Note:- Jointing shall be done by overlapping and tightning with 2 sets of brass nuts, bolts and spring washers spaced at 50mm
Supply & laying Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6 SWG Galvanised steel wire complete all as sepcified and directed.
SHAH AND SONS
M/S ABDUL SALAM MIR CONSTR CO PVT. LTD
M M SHAWL Engineers and contractors pvt ltd
EPACK Polymers Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid