Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance SAMAD COMPLEX MUNAWARABAD M A LINK ROAD SRINAGAR SRINAGAR SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹43.1 L
Closing Date
6 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Supplying, fixing, testing and Commissioning of Air Conditioning System and allied works for 2nd Floor old Administration Block at Main Campus.
2022_UDJK_165202_1
F(UCD)(E.Tend)/KU/104/21
Open Tender
Electronics Equipment
Item Rate
180 days
Main Campus
As per NIT
3 documents required · 3 mandatory
₹1,100
Registrar University of Kashmir
Exempted
7 Apr 2022
24 Mar 2022
7 Apr 2022
24 Mar 2022
6 Apr 2022
24 Mar 2022
120 days
Amount
Supply, testing and commissioning of 2 ton (3 and above star Ratting) wall mounted split fully inverter type AC with Heat Pump, fan coil unit and condensing unit Hot and Cold operation temperature range should be minimum -10 (minus) to 46 degree C Inverter type . including Refrigerant Gas filling comlete in all respects
Supply, testing and commissioning of 1.5 ton (3 and above star Ratting) wall mounted split fully inverter type AC with Heat Pump, fan coil unit and condensing unit Hot and Cold operation temperature range should be minimum -10 (minus) to 46 degree C Inverter type. including Refrigerant Gas filling comlete in all respects
Supply of copper piping soft drain with 9mm nitrite rubber insulation on both pipes with steel clamps and including fully GI Tapping
Supply, fixing of PVC flexible pipe for drain pipe
Supply of control and power cable for connection of indoor and outdoor units as per specifications of OEM
Supply of M.S Stands for outdoor units
Additional Gas Charges Complete job
VRV system for conference Room/ dinning hall HIGH SIDE EQUIPMENT Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow/ Variable Refrigerant Volume modular type air- conditioning system suitable for Heating/Cooling by inverter driven capacity control compressor complete with indoor and outdoor units with individual controller , fittings etc. including full charging of R-410A refrigerant gas complete .The system should work below minus 10 and above 46 degree C "AIR COOLED VRF/ VRV OUTDOOR UNITS Supply Installation, testing and commissioning of Modular type outdoor units along with base frame as recommended by OEM equipped with highly efficient scroll / DC Twin Rotary compressors all with inverter type compressors special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below."
EVAPORATIVE VRF INDOOR UNITS Supply, Installation, Testing and Commissioning of modular type indoor units comprising of all accessories as per the specifications. The indoor units shall be suitable to work on Cooling as well as Heating mode. The job includes necessary civil works and supply & return air grills for concealed duct units along with allied items. The indoor units shall be suitable for operation on 220±6% /415±6% volts,50Hz, 1/3 phase AC power supply and the indoor units shall be of following Cooling/ Heating capacities:
casette Type : 3 TR
Hi- Wall Type : 2TR
Referent fittings (Y-joints)
Corded Remote for Indoor units
Main centralised controller units suitable for minimum 6 indoor units
LOW SIDE EQUIPMENT REFRIGERANT PIPING Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping suitable for R 410a refrigerant of suitable size as required and duly insulated with 19mm/13mm thick closed cell elastomeric insulation in tubing form. External Refrigerant piping shall be laid on GI cable trays. Piping inside occupied spaces shall be supported using M S hangers duly painted with black enamel paint. Entire refrigerant piping work be carried out in accordance with the specifications. Piping shall be of following sizes :
6.4 mm dia with 13mm thick nitrile rubber insulation
9.53 mm dia with 13mm thick nitrile rubber insulation
12.7 mm dia with 13mm thick nitrile rubber insulation
15.8 mm dia with 13mm thick nitrile rubber insulation
19.0 mm dia with 13mm thick nitrile rubber insulation
22.2 mm dia with 19mm thick nitrile rubber insulation
28.6 mm dia with 19mm thick nitrile rubber insulation
PVC DRAIN PIPING Supply, installation, testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated.
32 mm dia
25 mm dia
Electrical panels and wiring
Providing and fixing of Electrical panel with Scanner ELCB 63 Amp TPN125 A with 125 A bus bar MCCB for each outdoor unit and MCBs etc as per specifications of OEM
Providing and fixing of Timedelay circuit through 4P 125 A contactor including low- high cut along with single phase protection Control Panel for whole circuit
Providing and fixing of MCB sub-panel box. 63 A MCB DP 1 No, 16A MCB DP 6 No enclosed in MS box duly fitted on wall.
Providing and fixing of points wiring for IDU using 2.5 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 6/16 Amp. of Modular Switch, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 2.5 mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects note: all items included like Conduit, wire, switch box, switches, 16 A 3Pin Top etc.
Proviing an laying of control cum transmission wiring of 2 core x 1.5 sqmm copper cable in PVC conduits between indoor and out door units.
Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Note : Rates of Suitable PVC conduit included in above description for the follwing items 4 x 10 sq.mm + 2 x 10 sq.mm earth wire for Sub main wiring
2 x 6 sq.mm + 1 x 6 sq.mm earth wire
Providing and fitting of snow/ bird protection hood in 22 gauge GI sheet with 1 inch wire mesh duly spray painted.
Supply and installation of lader type GI 'U' shaped channel cable tray of following sizes. 40 x 150 x 40 x 2 mm
Additional Refrigerant charging R-410A of entire VRV system
Providing and fixing of Double earthing continuity conductors of G.S.S to panel boards and equipments as per Indian Electricity Act.
Construction of Foundation for VRF outdoor unitr (as required at site) of 600mm high and 300mm deep below ground level. Excavating/ steel bars/ Reinforced cement concrete work in well-staining, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse Sand (zone-III): 3 graded stone aggregate 20 mm nominal size). Along with latform shelter (roofing) As required as per site, complete in all respects.
Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements to cover the pipe line/ finishing etc.
Supply of 5KVA Automatic Voltage Regulator (AVR) Air cooled Copper wounded wall mounted having input line voltage from 90 volts to 260 volts with time hi, low cut and delay protections.
Supply, installation, testing & commissioning of 2 kVA 1 phase Inverter with 2x180AH 12V tubuler Batteries and battery trolley including input/output leads/ Switch sockets etc. to make the system operational. Note: Item Should have minimum of two years Warrenty and free service.
M/S CITI TECH SOLUTIONS
Elevees Infrastructure Private Limited
Rawafid Engineering Consultancy Pvt. Ltd.
stage.html
html • 0.02 MB
finance_382770.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .