| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | ₹2.8 Cr Quoted ₹2.9 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹3.0 Cr+₹4.3 L (1.48%)Rejected-Finance 6313 14 PUNJABI MOHALLA AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹3.0 Cr+₹4.3 L (1.48%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹3.0 Cr+₹4.7 L (1.60%)Rejected-Finance | ₹3.0 Cr+₹4.7 L (1.60%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹3.1 Cr+₹17.5 L (5.97%)Rejected-Finance | ₹3.1 Cr+₹17.5 L (5.97%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹3.3 Cr+₹36.0 L (12.3%)Rejected-Finance | ₹3.3 Cr+₹36.0 L (12.3%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹3.2 Cr
EMD Value
₹3.9 L
Closing Date
30 Jun 2025, 6:00 pmClosed
COMMANDER WORKS ENGINEER
CWE HISAR, HISAR MIL STN
SPL REPAIR TO JCOS OR MD ACCN UNDER GE HISAR AND GE WEST HISAR
2025_MES_709260_1
CWE/HSR-21 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
HISAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE WEST HISAR
₹3.9 L
2 Aug 2025
20 May 2025
2 Jul 2025
20 May 2025
30 Jun 2025
16 Jun 2025
21 May 2025 - 28 May 2025
Amount
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each and complete all as specified and directed.
S&F made single extruded WPC (Wood Polymer composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
-ditto- all as per item No 3 above but of frame size 65 x 100mm
-ditto- all as per item No 3 above but of frame size 65 x 125mm
Factory made single exturded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: Stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F for 1mm thick factory made pressed steel shutter fixed with 1.25mm thick pressed steel frame of 105 x 60mm and as reqd for cupboards (consisting two shutters) including 06 Nos hinges of size 75mm long and Godrej pattern three way locking system with suitable shape & size 12mm dia MS rod & 01 Nos chromium plated handle of size 150mm long with & including two coats of shop spray synthetic enamel painting over a coat of red oxide primer as colour approved by GE. Note 1: Cupboards frame to be fixed with 06 Nos nuts & bolts of dia 12mm & 150mm long at vertical outer edge of cupboards brick wall / concrete surface including making good the distrubed surfaces complete all as specified and directed. 2 Front Face shall only be measured for payment purpose.
S&F 30mmthick factory made wire mesh solid WPC (Wood Polymer Composite) shutter of consisting density of 600 Kg/Cum an door to be panelle with SS mosquito mesh an XTN aluminium meshfor aditional strength and safety purpose hologram to be clearly visible on material, Manufacture test certificates to be submitted complete all as specifie and as directed by Engr-in-Charge. Note : Stainless steel butt hinges and necessary S S screws shall be paid separately
S&F steel window box type with side hung shutters Factory made including box type hinges with steel handle and steel peg stay complete with glazing bars devetailed or welded.The rates include for painting with one shop coat of zinc chromate primer.
S&F steel window box type with side hung shutters Factory made including box type hinges with steel handle and steel peg stay complete w/o glazing bars devetailed or welded. The rates include for painting with one shop coat of zinc chromate primer.
S&F steel ventilator with top hung shutter of glazed & gauged including hinges, steel peg stay complete with glazing bars including one shop coat of redoxide primer complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, hand rails, cupboards frame and similar work con- forming to Fe.290.Gde-E-165 with and including necessary cutting and welding complete all as specified and directed.
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of new or previously untreated steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L PCC 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in steel chowkhats, hold fasts and bed blocks etc including necessary form work complete all as specified and directed.
S & F GI wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed in steel windows and wooden shutters.
Supply and fixing acrylic transparent sheets 3mm thick in square / rectangular area of each pane not exc 0.5 sqm and fixed /lock with window frame by using PVC snap beeding with necessary self tapping reviting / screwing and suitable method with and complete all as specified and directed.
Supply and fixing acrylic frosted/figured sheets 3mm thick in square / rectangular area of each pane not exc 0.5 sqm and fixed /lock with window frame by using PVC snap beeding with necessary self tapping reviting / screwing and suitable method with and including and complete all as specified and directed.
S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed.
S&F extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed.
S&F 140 mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door complete all as specified and directed.
S&F mild steel 300mm, ordinary rat rail rod pattern springs, including roller and roller plate complete all as specified and directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 50 mm thick (1:3:6) Type-C-2 (using 40mm graded crushed stone aggregate) as in plinth protection complete all as specified and directed.
M&L non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:6) compete all as specified and directed.
M&L non skid coloured designer ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed with Epoxy to match with and including 15mm thick screed bed in CM (1:6) compete all as specified and directed.
-ditto- all as per item No.29 above but on skirting over with and including 10mm thick backing coat in CM 1:3 complete all as specified and directed.
M&L glazed ceramic coloured, designer & pattern (dark & light shade combination) tiles in 450 x 300 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed with Epoxy to match over with and including 10mm thick backing coat in CM 1:3 and d complete all as specified and directed.
M&L Black Granite(of any type), 20 mm thick machine cut laid over cement screed as in Cooking Plateform and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the granite stone including cutting and polishing with and including 15mm thick (1:6) screed bed or bedding in cement mortar 1:6 complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors,walls aprons etc (laid, bedded and pointed in any mortar) complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 18-20mm thick of size not less than 0.30 Sqm of each slab over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with and including 15mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed. (Note : Single piece tiles will be placed on the surface of stair case tread area).
M&L for Kota stone slab 15mm thick in riser of bricks steps & riser of staircase , skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing with & including backing coat in 10mm thick CM (1:3) to receive Kota Stone complete all as specified and directed (Note : Single piece tiles will be placed on the surface of stair case riser area).
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Demolition of RCC Roofs, floors (other than ground floors), beams, staircases, landing, chajjas upto three storeys ,RCC Water tanks and similar suspended work of any type and description not otherwise described for and all as spd and directed.
M&L RCC 1:2:4 Type-B1 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like incl necessary forms works complete all as specified and directed.
S&F TMT Mild Steel bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, less than 0.9mm dia or securing with clips.
M&L for formwork of soffits of suspended slabs such as roof slab, floor slabs, landigs, shelves and similar work, not exc 200mm thick rough finished surfaces of concrete complete all as specified and directed.
Dismantling roof tiles, single layer on roofs complete all as speified & directed.
Demolition of mud in roofs, any thicknes, including plastering and leeping (whether full thickness removed or only or part thereof) complete all as speified & directed.
M&L for preparation of roof surfaces (old or new) with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles with and including providing 50 mm thick (average) PCC 1:2:4 type B-0 (using 20mm graded stone aggregate) with maintain the proper roof slope as in bedding, coping and kerb complete all as specified and directed.
M&L for providing 10mm thick polymer modified plaster in ratio 1:10 (1 part of polymer and 10 parts of cement with solid contents not less than 30%) over slab and applying priming coat of epoxy primer with resin and hardner with water dilution as per manufacturer instructions, applying 1st coat of solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm and applying 2nd coat solvent based polyurathene liquid mambrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm over dried 1st coat complete all as specified and directed. Make : M/s Asian Paints Ltd. / M/s STP Ltd/ M/s Sika India Pvt. Ltd.
S&F in repair vitreous China, squatting pan, Orissa Pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with PTMT trap of suitable size ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of cement concrete bedding & making good to floor complete all as specified and directed including taking out old one.
S&F in repairs 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as reqd complete all as specified and directed.
S&F Vitrous china wash hand basin, white, flat back of size 550 x 400 mm white excluding taps, and plug and porcelain stopper but including bracket, cutting for and pinning the ends of brackets, PTMT waste coupling of 32 mm dia (half or full threaded )(Min wt 45 gms /40 mm -60 gms) & waste pipe as suitable complete all as specified and directed.
Taking up or down 15mm bore steel / composite / UPVC tubing and connection from any position concealed / exposed including cleaning for refixing or removal to store complete all as specified and directed.
Supply&Laying of CPVC pipe, SDR 11 ,16mm outer dia & fittings on walls/ceiling or laying in floors complete all as specified.including taking down old pipe
S&F Brass Elbow for special fitting of 16 mm bore CPVC pipe complete all as specified and directed.
S&F Brass Tee for special fitting of 16 mm bore CPVC pipe complete all as specified and directed.
Taking up or down 20mm bore steel / composite / UPVC tubing and connection from any position concealed / exposed including cleaning for refixing or removal to store complete all as specified and directed.
S&F 20 mm dia steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd and fixed with or without concealed to walls, ceilings or laid in floors complete all as specified and directed.
Taking up or down 15mm bore steel / composite / UPVC tubing and connection from any position concealed / exposed including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15 mm dia steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd and fixed with or without concealed to walls & surface of roof slab with and including making good to required surfaces by using white cement complete all as specified and directed.
Re-fixing old 15mm dia steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd in new or old position and fixed with or without concealed to walls, ceilings or laid in floors complete all as specified and directed.
Re-fixing old 20mm dia steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd in new or old position and fixed with or without concealed to walls, ceilings or laid in floors complete all as specified and directed.
Supply & Laying of 3-layer PP-R Polypropylene random copolymer)concealed pipes 20mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etccomplete all as specified and directed.
Dismantling water tanks, open or closed, in position and removing to store of capacity exc 500 ltr but n.exc 1000 ltr.
S&F 15mm dia CP angle valves complete all as specified and directed. Make Jaquar or equivalent
S&F Wall Mixer 3-in-1 System with 115 mm Bend Pipe & Aerator complete all as specified and directed. Make Jaquar cat pat No MQT-519KN
S&F CP Central Hole Basin Mixer with Popup waste with 450 mm long mm Long Braided Hoses complete all as specified and directed. Make Jaquar Cat pat No COS-101051B
S&F CP Sink Mixer with Swinging pipe Spou complete all as specified and directed. Make Jaquar Cat pat No MQT-527S
S&F in repair 15 mm bib tap ( fancy type) , cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F 20 mm dia Stop valves / gate valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixedcomplete all as specified and directed.
S&F CP soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F brass chromium plated shower roses of size 125mm with or without swivel joints, any size, including shower arm 15mm size, 195mm long bend of 45degree with flange of CP fixing to steel pipe or union complete all as specified and directed.
S&F SS , premium type , peg set 6. heavy weight complete all as specified and directed.
S&F 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed.
S&F chromium plated Tubular towel rail, 18/20mm dia, D type, 60cm long between flanges, fixed withl screws complete all as specified and directed.
S&F superior quality SS Curtain rod, 20mm dia with and including SS bracket 2 Nos of each opening and fency type SS side knob of required shape and size 2 Nos of each opening as approved by Engr- in charge and complete all as specified and directed.
S&F in repair single/multi PVC (SWR) floor trap 75mm dia, palin with grating including joining to waste pipe, fixed in cement concrete type B-1 (1:2:4) using 20mm graded broken stone aggregate co,mplete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
Dismantling of cast iron pipes any size of bore as in soil waste or vent pipe including removal of cement joints fixed to wall or laid in floor complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed.
S&F 110 mm PVC (SWR) access door bends any radius complete all as specified and directed.
S&F 75 mm PVC (SWR) access door bends any radius complete all as specified and directed.
S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 110mm PVC PVC (SWR) vent cowl complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for Brick work with Fly Ash Bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete and all as specified and directed.
M & L for Brick work of Fly Ash Bricks old size, straight or curved on plan to any in half brick thick walls , built in cement mortar 1:4 complete and all as specified and directed.
Taking down cement plaster of any description upto three storeys including necessary scaffoldings including raking out joints, hacking for key, scrubbing down with water etc. from wall & ceiling surfaces complete all as specified and directed.
M&L rendering 10 mm thick in CM 1:6 on fair face of brick /concrete surfaces of any description and finishing the surfaces even and smooth without using extra cement complete with complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer of same make complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer of same make with and including complete removal of existing treatment of any layer of wall by sanding with internal dust extraction system for clean environment and complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying three coats of white wash on undecorated surface complete all as specified and directed.
M&L preparing old plastered or unplastered surfaces of walls and applying two coats of white wash on old decorated surface with and including complete removal of existing treatment of any layer of wall complete all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash on undecorated surface complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of ceiling and applying two coats of white wash on old decorated surface with and including complete removal of existing treatment of any layer of ceiling surfaces complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement / manufacturer's instructions on brick/concrete wall surfaces of any description, and finishing the surfaces even and fair complete complete all as specified and directed.
Supply only liquid water proofing compound.
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of acrylic smooth exterior paint over and incl of a coat of exterior wall primer as aprproved by Manufacture.
M&L for Complete removal of existing treatment by sanding with internal dust extraction system for clean environment, washing down and stopping of distempered and painted surfaces and M&L applying two coats of acrylic smooth exterior paint over and incl of a coat of exterior wall primer as aprproved by Manufacture.
S&F rotational moulded polythene three layer water storage tank 500 ltrs in white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I incl taking down existing tank complete all as specified and directed.
S&F 20mm bore dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
S&F 20mm bore dia nipple suitable for HDPE water tank (Min weight 15mm-38 gms/20mm-45gms/25mm-65gms)fixed complete all as specified and directed.
S & F in replacement of (ANTI LIFT MONKEY PROOF) removable metallic lid cover of PVC OH tank with fixing arrangement incl threaded GI nut and bolt and other fixing arrangements required complete all as specified and directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) n. exc. 30 cm high with synthetic enamel paint as required for marking of building numbers all as specified and directed.
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including PTMT waste copupling & waste pipe 900mm long complete all as specified and directed.
S&F Kitchen plate rack of overall size 750 mm x 600mm x 250 mm complete all as specified and directed.
S&F corner glass shelf 300mm (with brass brackets) complete all as specified and directed.
M&L for treatment of sunken floor slab comprising of the following specifications with and including demolition of PCC in sunken portion/ floors including removal of the debris outside the MOD land and complete all as specified and directed:- (i) Demolition of PCC in sunken portion /floors and Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including S& f in repair 40 mm dia, 450 mm long medium grade spout pipe and cutting holes in bricks or RCC wall for the same (ii) Rendering of uneven surfaces at bottom and sides up to floor level with 15 mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seppage and where dampness / seppage is noticed, nozzles shall be fixed and grouting carried out. (iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in Fosroc / Thremax as approved by GE. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or or equivalent make in Fosroc / Thremax as approved by GE in two coats @ 3kg/sqm to sanwiched with glass fibre reinforcemnt: Sika Fab-1 or or equivalent make in Fosroc / Thremax as approved by GE over base coat as per mnaufacturer's instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint . (viii) The sunken floor shall be filled with lean concrete 1:5:10, type E2(40 mm graded aggregate) Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all M&L is inclued in the rates quoted above.
Cutting holes into or through cement concrete slabs and cutting through reinforcement chajjas, etc reinforced or other wise surfical area n.exc 100 sqcm as directed to insert angle iron for holding chajjas / coller platforms as required complete all as specified and directed.
S&F Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20mm of the length indicated), for cooler stand, chajjas complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall and in chajjas, fixed with self tapping screws complete all as specified and directed.
S&F rolled mild steel framed work as in doors or gates of angle or other section conforming to FE-410-W (Gde-E-250) Quality A, with gusset plates, rails braces, etc complete drilled for fixing of sheets and including steel sheeting or other covering and hanging and fixing complete as in garrage door and roof access door complete all as specified and directed.
Providing and Erecting steel props (upto Full Height, Braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till reqd and as directed.
Chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and directed.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat complete all as specified and directed. Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar).
Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2 mm of chemical compound as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78 complete all as specified and directed. Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar)
Providng extra reinforcement with TMT bars as per site design requirement including straightening ,cutting ,bending, placing in position ,binding with GI wire of 18 gauge etc complete in all respects .Additional reinforecment wit hadequate lap length & rings at required spacing shall be tied with existing reinforcement using binding wire or welded complete as per site requirement and directions.
16 mm x 160 mm
20mm x 200 mm
Providing and fixing shear connectors of 16 mm dia TOR steel upto 160 mm Length Epoxy Resin RCC Members including power Drilling ,cleaning of holes ,insertion of epoxy ,placing shear connectors in position to ensure the bond as per manufacturer recommendation complete as per site requirement and directions.
M&L for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including prepartaion of surface throughly and cleaning complete where ever required with using Product as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and directed.
Providing and fixing water tight centering & shuttering including bolting, strutting, propping etc. including removal of form work from column, beam , slab etc. complete as per site requirement and directions.
Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product: SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed .
M&L for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture Sika Plasto creat plus or equivalent make in Fosroc / Thermax as per manufacturer's instructions as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. The gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions and directed.
M&L for providing and fixing 12-16mm dia injection ports non returnable nozzle by drilling, cleaning and sealing holes 50-75 mm deep with fast setting high strength Epoxy putty, solvent free, three component compound based on epoxy resins, graded fillers and thixotropic agents as approved by GE as in beams, columns, slab and parapets as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for grouting of nozzles with low viscous moisture insensitive, High strength, epoxy resin grout as approved by GE with pressure not excedding 2-3 Kgf/Sqcm till the nozzle refuses to take further grout including cutting extra length of the nozzle after the grout hardens and finishes as per the technical specifications and manufacturer's instructions complete all as specified and directed.
Making 'V' Groove of 3mm wide and 3mm deep over crack line by electrically operated grinder with diamond concrete saw blade and cleaning it by Air Blower as directed.
Supply and Apply of rust non shrink repair mortar for non moving cracks in plaster and walls Product Consumption: 25 RMT/Kg for crack size of 6mm x 6mm Density: 0.85 Kg/l at 27°C
Supply and Apply of ready to use water resistant White Cement Based Finishing /smoothing material in 1.5 mm thickness for indoor and outdoor plastered surfaces. Product Coverage :1.2 Kg powder /Sqm/mm thickness System Requirement :tensile Adhesion >1.0 N/mm2 at 28 days (According to EN1348 )water capillary Absorption 0.8 ml at 24 Hrs as per Karsten Tube Test ,Water Retentivity >98%(according to EN 196-3)
Removal of plaster/finishes of the wall patch area observed to expose the brick surface. Cleaning; shifting and stacking debris, necessary lead and lift and disposal of debris outside the premises etc., complete as all as specified and directed.
Making the grooves 10mm * 10mm above coating area and fill with SIKAFLEX-127, single component, elastic, moisture curing, hybrid moisture curing, hybrid polyurethane based construction sealant and adhesive.
Drilling holes at the first joint of masonry wall at ground level horizontally 10mm diameter in masonry structure along the side of the joints at 45 degree so as to cross the brick/block at the intervals spacing in 300 mm depending on extent of rising dampness as per recommendation of Engr-in-charge, cleaning of hole :- Clean the hole by air blower prior to fixing nozzles. Install NRV packer injection packers 10 mm diameter, 10 cm long in the holes and tighten. Fix the packer securely using Sikagard 694 F(I) and supply and apply of 3 parts, very low viscous elastic polyacrylic injection resin Sika @ Injection 306 with a versatile and adjustable reaction time having mixed viscosity: 3-11 M pa s at +20 degree C, reaction time : adjustable according to ambient temprature and execution requirement between 8-50 Mins Ph 9-10. Tested as per wissbau No 2002-094- (1A) fuction test with re-injectable hose system. these holes should be drilled until a depth of approx. 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump Sika @ injection -306 @ at>20 bar into a behind fissures or into masonry joint which are allowing water to infiltrate into unwanted area if voids is masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout when movement stop of sika @injection -306 appears at the next packer move to the next packer and inject. if the dampness is heavy inject similarly at next joint line, pumping of sika injection is to done till chemical comes out from adjacent holes. Cutting of packers :- Cut the packers after completion of grouting without damaging structural elements. Note : consumption of all chemicals is deemed to be included in the quoted rate of the contractor, consumption of chemical per hole may vary from 0.5 kg to 1.5 kg.
Providing and applying acrylic polymer SikaTop® -107 Seal IN, 2 component polymer modified cementitious coating of tensile strength of 2.0 N/mm2 as per ASTM D 412 , elongation of 110% as per ASTM D 412, Shore A hardness ~ 90 (ASTM D2240), resisting 5 bars hydrostatic pressure as per EN 12390-8:2019 applied in two coats @ 3kg/sqm over a saturated surface and the interval between each coat of coating application is 6-8 hrs. The 2 coats must be applied at right angle to each other with a brush. Finally sprinking sand over the second coat for better adhesion with plaster
Providing and laying of 10 mm thick hand applied Sika Monotop 122F single component, dual shrinkage compensated, thixotropic high strength formulation trawlable mortar on the brick wall including pointing of brick joint over a bond coat of SIKA Latex: Water"cement - 1:4:6 with SIKA Latex consumption @ 100 gm/sqm on the wall surface. the PMM should have compressive strength > 50 MPa in 28 days as per ASTM C 109 (7cm cube). (Complete finished item with all leads and lifts) and preparing the plaster of thickness up to 15mm over the brick masonry surface by providing and applying a bond coat of Sika Latex : Water : Cement - 1:4:6 with Sika Raintite-I consumption @100 gm/sqm on the wall surface followed by hand mix of cementitious mortar 1:4 to be mixed with permeability reducing polymer Sika Raintite-i @ 400gm/sqm (6%) by weight of cementitious content at time of mixing with water as per manufacturer's recommendations including all leadlife, levelling the surface, curing etc complete.
Removing all disintregated and loose concrete of any thickness incl plaster if any in RCC Column, Chajjas, Slabs, Beams, Lintels etc, removing all loose rust/scale from exposed reinforcement bars by using wire brushes and sand paper incl cleaning of exposed surfaces of reinforcemnet with protective anti corrosive epoxy bonding chemical (Mate Pidilite) and tide reinforcement bars/IRC fabric 50mm x 50mm x 12 gauge if reqd to reinforcement concret boind primer to exposed surfaces and applying cement moter 1: 3:4 with MPC (one part cement 3 part send : 1 part 6mm course aggregate) 2 and average thikness note less than 20mm incl IRC 50mm x50mm)x 12mm gauge or reinforcement bars in the revoving debris all as specified and directed by EIC (Note : Incl necessory scafolding to execute the work )
M&L 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base of floors all as specified.
Dismantling of stone slabs and tiles of any description or thickness in floors,walls aprons etc (laid, bedded and pointed in any mortar) complete all as specified and directed.
M&L Chequered cement concrete tiles 20 cm X20 cm X 25 mm thick over 15 mm thick bedding of CM 1:6 in floors ,set,jointed and pointed in neat cement slurry with gray cement and pigment and complete all as spd and directed
Demolition and breaking up drain pipes (salt glazed ware or RCC or PVC) set in cement mortar 150 mm dia complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware or RCC or PVC) set in cement mortar 200mm dia complete all as specified and directed.
S&F RCC pipe class NP-2 laid to slope in trenches jointed and tested complete with collars for 150 mm dia pipe complete all as specified and directed.
ditto above- but 200 mm dia .
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm dia pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm dia pipe complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material (Soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete.
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in coping & benching including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work, finished even and smooth using extra cement complete.
M&L for precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs for manholes (square / rectangular / circular of any type and size with Angle iron bend to shape of manhole etc, shelves and similar articles with plain faces including necessary formwork and setting in cement mortar 1:6 including necessary use and waste of formwork and demolition of existing RCC cover slabs complete
Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete.
Re-fixing old serviceable 15mm bore CP bib tap/ angle cock/ pillar tap, concealed stop cock, CP mixture valve, shower with all fittings after repair by suitable size of brass head and other materials as required in new or old position and fixed with or without concealed to walls with and including making good disturbed surfaces by using white cement and cement mortar (1:4) mixed with pigment to match the existing surface complete to the entire satisfaction of Engineer-in-charge.
S&F in repair CP angle valves (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch screwed both end for iron pipe or for unions complete all as specified and directed by Engr-in-Charge.
S & F for Pipe Supporting Clamping for Single pipe of dia 110 mm (4") down take pipe fixing done with Clamping System consists of Rain Water Bracket Set with Pipe Support Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3"): Pipe Support Clamping made of : 1. Rain Water Bracket Set with pipe support channel for 110 mm pipe having Wall Distance 75 mm (3") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs. 2. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Rain Water Bracket Set with pipe support channel for 110 mm pipe; Wall distance 75 mm (3") - 1 Nos. ; 2. U bolt Rubber Sleeve mounted for 4" (110 mm) PVC Pipe Dia. - 1 No.; and 3. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2") - 2 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Jodhpur Zone Technical Drawing (TD) of Factory Made Pipe Supporting System : CEJZ/TD/102. Make: Shaivi or equivalent as approved by GE.
S & F for Pipe Supporting Clamping for Single pipe of dia 75 mm (3") down take pipe fixing done with Clamping System consists of Rain Water Bracket Set with Pipe Support Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3"): Pipe Support Clamping made of: 1. Rain Water Bracket Set with pipe support channel for 75 mm (3") Pipe Dia. having Wall Distance 75 mm (3") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs. 2. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Rain Water Bracket Set with pipe support channel for 75 mm pipe; Wall distance 75 mm (3") - 1 Nos. ; 2. U bolt Rubber Sleeve mounted for 75 mm (3") Pipe Dia. - 1 No.; and 3. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2") - 1 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Jodhpur Zone Technical Drawing (TD) of Factory Made Pipe Supporting System : CEJZ/TD/102. Make: Shaivi or equivalent as approved by GE.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coat of cement base paint on undecorated surface complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls and applying one coat of cement base paint on undecorated surface complete all as specified and directed.
Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2 mm of chemical compound as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78 complete all as specified and directed. Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar)
M&L preparation of old wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking down shutter of any description area exc. 1 Sqm and n.exc. 2 Sqm complete all a specified and diredted.
S&F 30mm flush door shutters, soild core construction, with block board core and plywood face panels, commercial type both sides complete all as specified and directed.
M&L non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:6) compete all as specified and directed. Note : Tiling work shall be done with spacer of 3-5 mm and using Tile levelling machine for checking level of adjecent tiles and all as directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge.
S&F in stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge.
S&F in repair plain glass 4.00 mm thick, pin head type and glazing with oil putty & necessary screwing / cliping in squares/rectangle exc 0.5 Sqm in each pane complete all as specified and as directed and directed.
S&F in repair figured glass 5.00 mm thick, pin head type and glazing with oil putty & necessary screwing / cliping in squares/rectangle exc 0.5 Sqm in each pane complete all as specified and as directed and directed.
S&F in replacement aluminium anodized powder coated ventilator using rectangular tube of size 63.5 x 25 x 1.5mm with 4mm thick design glass louvers etc., complete all as specified and directed.
S&F stainless steel butt hinges medium weight of size 100 mm fixed with stainless screws complete all as specified and directed.
S&F 100mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed.
S&F extruded aluminium alloy handles 100 mm long fabricated type anodised complete all as specified and directed.
M&L 18/19 mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, fixed with screws to timber & iron frame-work including suitable size of wooden frame and PVC fillets to cover the front edge of boards as in shelves and other smiliar works complete all as specified and directed by Engr-in-Charge.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white with P or S trap with and including plastic water closet seat cover , connection to trap, flushing pipe & anti -syphonage pipe etc including necessary materials for fittings & making good to floor complete all as specified and directed by Engr-in-Charge.
Taking down Ceiling Fan / Exhaust fan, sealing cable end, dismantling blades and louvers complete and depositing to the MES store/location all as specified by Engg-in-charge.
Sipply and fixing in replacement ventilating Air fresher Fan of size 200mm sweep, AC single phase 230V 50Hz. 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with PVC Sheathed copper conductor flexible cable of suitable size drawn in flexible PVC conduit from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge. |Note:- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
Taking down Electric meter after disconnecting all necessary electrical connections from DB Boxes and deposit to MES store yard of AGE E/M GE Hisar and reconnecting in DB Boxes after completing the electric wiring of the building all as specified and as directed.
Taking down carefully old unserviceable point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
M&L for point wiring for concealed Point wiring for one light point/fan point/bell point controlled by one switch (using red,black and green colour wires as colour coding) complete with 1.5 sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multistrand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20 mm dia ( medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook,elbow, junction boxes etc including pressed steel powder coated sunken terminal box suitable for modular switch socket ( minimum 50 mm deep and 1.6 mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per item No 177 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 177 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 177(here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per serial item No. 177(here-in-before) but for one bell/buzzer point controlled by one bell push
All as per serial item No. 177 (here-in-before) but for One Light point controlled by two, two way switches with cables 1.5sqm size.
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (lSI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (lSI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate).
Supply and fixing in repairs modular type switch 1 way 6Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 1 way 16Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 2 way 6amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type bell push , 5 Amp 240 Volts.
Supply and fixing in repairs modular type socket 6Amp - 3/5 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fixing in repairs modular type socket 6Amp/16 Amp - 3/6 pin combined 2 modle 230 volts AC complete all as specified and directed
S&F modular type Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed
S&F modular ceiling rose surface plastic 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
Supply and fix in repair Bell ding dong type, AC, 230 Volts, single pole.
S&F in replacement sheet metal enclosure distribution board SP&N, 12 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Legrand / L&T / Havells / C&S/IndoAsian/HPL. Note:(i) Cost of thimbles for connecting cable to MCCBs/MCB and making good disturbed surface is included in this item and nothing will be paid extra on this account.(ii) Cost of dismantling DB and MCBs and refixing the functional MCBs is also included in this item and nothing will be paid extra on this account.
S & F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, IS-8828 marked for fixing in DB complete all as specified & directed. .
S & F MCB SPN,32 Amps 240 Volts , 'C' curve, 10 KA, complete.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down existing u/s earthing all as specified & as directed. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Supply and fixing in replacement LED tube light fitting polycarbonate housing 1 x 40 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range: 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f IP rating: IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. () Surge protection minimum 2.5 kV. (k) CCT Minimum 6000K (I) CRI: Minimum 80 " (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fix Led inverter Batten 20 watt tube light with back time of 04 Hrs including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories
Supply and fixing LED lights fitting 1x 10W, 220V,AC wall mounted LED batten with aluminium extruded polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder, Aluminium housing connecting up with three core flexible copper conductor cable of suitable size.
S&F sheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with and including one 20 Amp SPN MCB 'C' curve complete all as specified.
Supply and fixing in repairs decorative wall light, stainless steel rust free fixture with white glass diffuser including 10 watt bulb lamp complete all as specified and directed. Make : Havells Voila wall Light or equivalent of makes
Supply and fixing in repairs round / square surface mounting 12watt minimum capacity LED panel in PDC housing and high translucent frosted plastic diffuser with 100lm/ w efficiency complete all as specified and directed.
S&F in repair Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- (i)Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length. (ii) Cost of taking down existing submain wiring including all accessories is included in this item and nothing will be paid extra on this account
Supply and hanging fixing in replacement ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W ( 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with fiexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. |Note : (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name_shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan, steel body AC single phase, 230 Volts of size 300 mm sweep with blades, frame and louvers complete all as specified and as directed by Engg-in-charge.
Supply, fixing and testing in replacement of factory made sheet metal enclosure, powder coated, indoor type (Single door) of size 0.90x1.50x0.20m suitable for wall / floor mounting (incl all arrangement for fixing) made out of 2mm thick CRCA sheet having independent compartments suitable for S&F 01 x MCCB 4 Pole, refixing of 06 Nos x Single Phase energy meter and S&F outgoing 06 Nos x MCB SPN and one set of indicator lamp, provided with front hinged shutter with lockable arrangement and clear glass to visualize the meter reading without opening the compartment with sufficient working space, prewired with single core PVC insulated and sheathed FRLS stranded copper conductor wire of size 6sqmm from bus bar to each meter compartment (for Phase, neutral and earth wire) and outgoing connections from meter to respective outgoing MCB duly crimped with copper thimbles complete all as specified and directed by Engineer-in-charge and consisting of following :- (i) Bus bar for 3 Phase system of 4 x 200 Amps rated insulated copper strip mounted on resin cast insulators in independent compartment having front openable shutter - 01 Set. (ii) MCCB 4 Pole 415 Volts, 63 Amps 16 KA with adjustable thermal magnetic release - 01 No (iii) MCB SPN 40 Amps 10 KA 'C' curve - 06 Nos (iv) Indicators lamps LED in Red/Yellow/Blue colour- 01 Set of three Note :- The quoted rates deemed to be inclusive of removing the serviceable energy meter from old panel and refixing complete. (ii) The layout sketch / schematic diagram and design of the panel should be approved by the Engineer-in-charge before starting of work.
M& L for spray painting of MS Boxes of DB Boxes accessories including de-rusting of surface and cleaning manually by scrubbing and wire brushing, washing throughly and dry properly, applying two coats of Zinc phosphate primer by spray machine,final painting of two coats with synthetic enamel paint by spray machine over priming coat, the colour of painting shall be as decided by Engr-in-charge.
M & L for GI tubing light grade 40 mm bore ISI marked for for cable protection fixed to floor/ground complete with all fitting all as specified and directed.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 2 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repair Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- (i)Two lengths of 4 Sqmm cable, one length of 4 Sqmm cable and one length of PVC conduit will be measured as one length. (ii) Cost of taking down existing submain wiring including all accessories is included in this item and nothing will be paid extra on this account
M/L for Cutting of hole in wall for opning for exhaust fan of size 200 mm and making good to facings where required and pointing in cement mortar 1:3 to ends or edges complet all as specified and directed by Engineer in charge.
Taking down of Geysers 25 litres compete with PVC Connections,flexible wire etc complete and depositing to the MES store/location all as specified by Engg-in-charge.
Fixing only Water heater geysers 25 litres along with minor repair if required and testing it full capacity all as specified. Note: Cost of collection of geysers from MES store/yard and anchor/mounting is included in this item and nothing will be paid extra on this
Supply and fixing PVC connection of 15mm bore heavy duty, length upto 45 cm with brass nut joints and washers at both end complete all as specified and directed
Supply, fixing and testing LED Building security light fitting of 35 Watt complete with robust body, corrosion resistant, superior finish, made in a single piece by high pressure die cast aluminium alloy including fixing on wall with 1.2 Mtr long GI pipe 25mm/suitable dia medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 and Total Harmonic Distoration THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should have high voltage withstanding capacity upto 300 volt AC. Driver should also have normal phase protection, no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degree Centrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be toughened glass to ensure IP 66 degree protection.Cover should not degrade due to heating and ageing. The efficacy of LED luminaries system shall be more than 110 lumens per watt
Sham Sunder Bansal (BID ID -3333736)
M/S RAJINDER SINGH (BID ID -3333403)
M/S Sulakh Brothers (BID ID -3341159)
CHOPRA BUILDERS (BID ID -3334038)
RAM KARAN GOEL (BID ID -3326119)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .