Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
25 Aug 2021, 6:00 pmClosed
AGE(I) ASVINI
INHS ASVINI
SPECIAL REPAIRS TO 04 NOS MT SECTION GARAGES AT INHS ASVINI
2021_MES_452346_2
8292/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE(I) ASVINI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
AGE(I) ASVINI
₹19,200
Yes
9 Sept 2021
12 Aug 2021
27 Aug 2021
12 Aug 2021
25 Aug 2021
12 Aug 2021
Amount
SCHEDULE 'A' PART I ( B/R WORKS) : M & L for chipping , removing, carefullly concrete work by low impact Hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the MD land complete as directed by Engr -in-Charge. Note - i) Hard concrete should not be removed by force. ii) The place of disposal shall be find out by the contractor.
M & L for cleaning existing reinforcement with wire/rotary wire brush, making the surface free from loose material dirt etc, complete applying two coats of alkaline rust converting primer (i.e. rust remover) FEOVERT conforming to ASTM-B-117, on the rebars (measurement shall be on the basis of exposed concrete) (Make : Feovert of Krishna Conchem, Roff rust cleaner of Pidilite, Dr Fixit Rust remover, Shali Rust Off of STP Ltd)
M & L for providing and applying two coats of anti-rust protective coating in the form of Acrylic Polymer mixed with Cement in (1:1.5) proportion (1 part polymer and 1.5 parts Cement) on rebars after cleaning of rust scales as per manufacturers instruction (measurement on the basis of exposed concrete area). (Make :- IPNET of Krishna Conchem, New Coat from Dr Fixit )
M & L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster or micro concreting conforming ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bonding between old concrete and new concrete
M & L for providing and applying jacketting at the bottom of roof slab with micro concrete (Molith-MC) M-40 including core cutting in the roof slab for pouring concrete of size 100-150mm dia ( 02 Nos per Sqm) and making good the hole as per manufacturers instructions and as directed. (Make : Micro concrete of Dr. Fixit or equivalent)
M&L for form work to sofits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exc 200mm thick ( horizontal or sloping) for smooth finished surfaces of concrete flat.
M&L for form work to edges of concrete slabs horizontal or sloping and similar works exc. 10cm but n.exc.20cm wide
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welding to the existing rusted reinforcement in the bottom of roof slab including necessary scaffolding, steel props, runners etc. complete all as specified. Note for Item No 1 to 8 - The rates quoted for these items shall deemed to be included providing and erecting steel props at 60 cm c/c on both ways and connected with steel runners to support the structure and maintaining in existing position till completion of the work and necessary scaffolding as directed.
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land. Note: The place of disposal shall be find out by the contractor.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:4) and finished even & smooth without using extra cement completed all as specified.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finished even & smooth without using extra cement completed all as specified.
M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant priming paint complete all as specified.
Material & labour two coat of acrylic paint exterior grade (100%Acrylic) over a one coat of primer including prepartion of newly plasterd surfaces of walls etc all specified on external surfaces (Make : Asian Paint (Apex)/Nerolac (1st quality)/Dulux (weather shield)
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing debris out side MD land. Note: The place of disposal shall be find out by the contractor.
M&L for 100 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in sub base and finished fair and even.
M&L for 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in flooring and finished even and smooth with using extra cement including providing 3 mm thick glass dividing strips 38 mm wide in position complete all as specified.
SCHEDULE 'A' PART II ( E/M WORKS) : Taking down carefully copper / aluminium point wiring (light, fan socket or power) through steel / PVC conduit / casing caping including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets, etc removing and making good to the disturbed surfaces of walls/ceiling etc, with its original specification complete all as specified and directed.
M & L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded HRFR copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including suitable size surface PVC casing caping (ISI marked) with all accessories and terminated in and including surface PVC modular box with cover plate and frame of sutable size including 1.5 sqmm size PVC insulated, unsheathed, multistranded HRFR copper conductor cable for continuous earth conductor (using green colour) and connecting to earth dolly for One light/ fan point/ bell point controlled by one switch 5 Amp, SP, one way 240 volts.
Ditto- all as per item No 18 above but One 3 pin 5 Amps socket outlet on same board with other switches
Ditto- all as per item No 18 above but One 3 pin 5 Amps switch socket on independent board.
M & L for point wiring with 4 Sqmm (nominal area) PVC insulated and unsheathed multistranded HRFR copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including suitable size surface PVC casing caping (ISI marked) with all accessories and terminated in and including surface PVC modular box of sutable size including 4 Sqmm size PVC insulated, unsheathed, multistranded HRFR copper conductor cable for continuous earth conductor (using green colour) and connecting to earth dolly for one 6 pin 16 Amps switch socket combination point on independent board.
S & F ceiling rose surface bakelite 65 x 50mm, three terminals ISI (Marked) complete all as specified and directed by Engineer-in-Charge.
S & F Modular switch 1 way 6 Amps, 1 module complete all as specified.
S & F Modular switch 1 way 16 Amps, 1 module complete all as specified.
S & F Modular Socket, 6 Amps 2/3 pin combined 2 module, complete all as specified.
S & F Modular Socket, 6 /16 Amps 6 pin 2 module, complete all as specified.
S & F MCBDB TPN 4 Way, (4+12) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 100 Amp copper bus bar for each phase, complete with din rail, Neutral and Earthing bar including taking out old U/s DBs, connection complete and making good the disturbed surfaces complete all as specified and as directed. Make:- Legrand cat part No. 507680 or Equivalent model of Havells/L&T/ C&S Electric Ltd/ABB.
S & F MCBDB SPN 4 Way, (4) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 100 Amp copper bus bar for each phase, complete with din rail, Neutral and Earthing bar including taking out old U/s DBs, connection complete and making good the disturbed surfaces complete all as specified and as directed. Make:- Legrand cat part No. 507610 or Equivalent model of Havells/L&T/ C&S Electric Ltd/ABB.
S & F in replacement of DX3 MCB SPN, 240 Volt, 40 Amp, 10 KA, IP 20 Protected terminals, Complete all as specified and as directed. Make:- Legrand cat part No. 408618 or Equivalent Havells/L&T /C&S Electric Ltd/ABB.
S & F in replacement of DX3 MCB SP, 240 Volt, 6 to 32 Amp, 10 KA, IP 20 Protected terminals, Complete all as specified and as directed. Make:- Legrand cat part No. 408595 or Equivalent Havells/L&T /C&S Electric Ltd/ABB.
S & F in replacement of DX3 MCB TPN, 415 Volt, 63 Amp, 10 KA, IP 20 Protected terminals, Complete all as specified and as directed. Make:- Legrand cat part No. 408683 or Equivalent Havells/L&T /C&S Electric Ltd/ABB.
S & F LED light fitting 1 x 20 Watts, 4 feet, Decorative, ultra slim square profile with extruded polycorbonate, environmental friendly , energy efficient , prewired complete with and including two Nos PVC box of size 75x75x20mm for mounting light fitting including taking down old FTL fitting complete all as specified . Make : Crompton ( Laser ray) cat part No: LDLSR20- CDL or equivalent model of Wipro/Philips.
M & L for earthing complete with G .l earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground vertically (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI lead 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to out side MD land, including PCC chamber in PCC (1 : 2 : 4) type B1 (using 20 mm graded stone aggregate), mild steel frame made out of angle iron of size 40mm x 40mm x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick Cl cover with handle , watering arrangement with funnel internally secured with wire mesh, 20 mm bore medium grade GI pipe for watering, 40 mm bore light grade Gl pipe for lead protection including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 on Srl page No 497 of SSR Part-I (2009) and connected to earthing test point all as specified and indicated including testing on completion as directed by Engineer-in-Charge.
Supply, fixing, stringing and drawing submain wiring with 3 run of single core 6 Sqmm PVC insulated and unsheathed, multi stranded HRFR copper conductor cable using colour code for phase red and neutral black with and including 4 Sqmm PVC insulated and unsheathed multistranded HRFR copper conductor cable in green colour connected to common earth point and connected to earth dolly drawn through and including 20 mm PVC casing caping, heavy grade (ISI marked) with and including all accessories etc including taking out carefully old sub main wiring and making good disturbed surfaces as per existing compete all as specified and directed. NOTE:- (i) Three run of 6 sqmm, one run of 4 sqmm earth continuity conductor and 20 mm PVC casing caping and accessories shall be measured and paid as one length.
Supply and fixing in replacement of ceiling fans 1200mm sweep (48"), summer cool type, Energy saving fans ,230V AC ,50 HZ Completed. Make-Havells/Usha/Orient.
Supply & laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 35 sqmm x 4 core laid in trenches, passing through pipes, fixed on walls including connecting properly by means of thimbles complete all as specified and as directed. Make : Finolex/Havells/Polycab.
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
Removing excavated material from the site of work to outside MD land complete all as specified.
M & L for dry river sand as cushioning for protection of UG cable including punning of sand in layers all as specified. Note: Thickness after punning down shall be measured and paid
Supply & laying factory made un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
M & L for cutting existing road, hard standing of 450mm wide and 450 depth for laying pipes, cables etc and filling the trench with murum, well rammed in layers and top 100mm filled with and including PCC 1:2:4 type B2 (using 40mm graded stone aggregate) and finished top surface fair and even complete all as specified.
S & F GI pipe 40 mm bore light grade for protection of cable laid in trenches or fixed to poles/wall with and including suitable size GI clamps complete all as specified.
M & L for PCC 1:2:4 type B2 using (40 mm graded stone aggregate) as in coping for steel tubular pole including necessary form work complete all as specified and directed
S & F in repairs DOL starter 6 HP to 10 HP, relay range 6 to 32 Amps, AC 415 Volts, 50 Hz, mounting on and including 30cm x 30cm x 25mm thick 2nd class HW plank and fixed to wall with suitable fixing arrangement complete all as specified and directed
jkconstruction
Unity Enterprises
Angrahit Services Trading Co
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .