Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 1ST FLOOR SHOP NO 42 SHIV JI COLONY AGROHA HISAR HARYANA 125047 | AGROHA | HISAR | HARYANA | 125047 | Accepted-Technical Documents found as per NIT |
| 2 | Accepted-Technical 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | Accepted-Technical Documents found as per NIT |
Tender Value
₹5.8 L
EMD Value
₹11,674
Closing Date
29 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DC Electrical
FTR HQ BSF Ferozepur
Renovation up gradation of 3 Nos 120 men Jawan barrack at Arty HQ BSF Faridkot (Part B SH Accessories Installation and Panel work)
2025_BSF_891084_1
44/EE(Elect)/FTR/JAL/PB/202526
Open Tender
Electrical Works
Percentage
90 days
AT Arty HQ BSF Faridkot
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹11,674
20 Jan 2026
23 Dec 2025
30 Dec 2025
23 Dec 2025
29 Dec 2025
23 Dec 2025
Providing and fixing of 9 watt LED Decorative, wall mounting, brushed nickel finish fixture with acrylic diffuser with 9 W LED lamp B22 base with wire complete with connection, testing commissioning etc as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(Upto 450 mm sweep)
Erection of wall bracket /ceiling fittings/Tube light fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required.
SITC of indoor type double door compartmentalized cubical panel of suitable size for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet and depth up to 300 mm with required hardware duly painted with powder coated. The panel having separate detachable gland plate, hinged door, with locking arrangement, earth bar/stud, 400 A/415V 4 strip aluminum bus bar duly PVC sleeved, including electrical mechanical interlocking, connection inter–connection for incoming/Outgoing cables with the required current capacity bus bar links (as per direction of Engg in charge), space for MCCBs and change over. The panel should be mounted on MS Base frame 75 mm x 40 mm x 5mm of suitable size and should have the provision of following instruments mounted and includingprovision of outgoing cable connections bus bar links of required current carrying capacityetc as required. (Indoor Panel should be as per design & drawing approved by Engg in charge and comprising of) Instruments Panel ) a) VAF Meter in each panel to be design b) LED Pilot light (22.5 MM dia) with protection MCB’s-03Nos)
Providing and fixing of following accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge. (In item No 5) i) 125 A TP MCCB 25KA with thermal magnetic release LV516332 Schneider
Providing and fixing of following accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge. (In item No 5) ii) 100 A TP MCCB 16-18 KA with thermal magnetic release LV510938 Schneider
Providing and fixing of following accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge. (In item No 5) iii) 63 A TP MCCB 16-18 KA with thermal magnetic release LV510934 Schneider
Providing and fixing of following accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge. (In item No 5) i) Spreader Links for 125 Amp TP MCCB
Providing and fixing of following accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge. (In item No 5) ii) Spreader Links for 100 Amp TP MCCB
Providing and fixing of following accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge. (In item No 5) iii) Spreader Links for 63 Amp TP MCCB
Earthing with G.I. earth pipe 4.5 mtr long x 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_936606.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .