| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 CrAccepted-AOC BAKRON KA WADA NEAR NEELAM CINEMA JODHPUR ROAD BALOTRA BARMER RAJASTHAN 344022 | BALOTRA | BARMER | RAJASTHAN | 344022 | ₹20.1 Cr Quoted ₹20.6 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹21.0 CrRejected-Finance CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹21.0 Cr | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹21.9 CrRejected-Finance | ₹21.9 Cr | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹25.2 CrRejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹25.2 Cr | L4 | Rejected-Finance NOT LOWEST |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT RECOMMENDED AS NOT MEETING CRITERIA OF AVERAGE ANNUAL TURN OVER. |
Tender Value
₹22.9 Cr
EMD Value
₹15 L
Closing Date
27 Jul 2022, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM DELHI CANTT 110010
RESURFACING RENOVATION OF DRAGON LOOP AND SOFT PENS AND PRVN OF ALLED WORK SERVICES AT AF STN SARSAWA
2022_MES_521486_1
CEWAC/SAR/T-01/2022-23
Open Tender
Civil Works
456 days
GE (AF) SARSAWA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE (AF) SARSAWA
₹15 L
CE (AF) WAC PALAM
4 Oct 2022
9 May 2022
3 Aug 2022
9 May 2022
27 Jul 2022
13 Jul 2022
9 May 2022 - 23 May 2022
20 May 2022
Amount
SCHEDULE `A' PART - I is to be design, planed and construct/build by cotractor not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Design and construction of weather shelter block of PEB structure of clear size 20m x 17m x 12 m height on new surface with the following specificat ion : - (a) Necessary excavation for foundation, flooring and removing of excavated materials (b) RCC foundation (c) Roof sheeting : 0.50mm thick pre-painted galvalume zinc coating GI based corrugated steel sheet (d) The design of weather shelter should be such that no birds can sit and set up nest and weather shelter should be bird proof by covering all places/ structural members (wherever there is a possibility of sitting and set up of nest by birds) suitably by anti bird net machine made UV stablized as manufacturer's specification (e) Both Side wall Cladding : 0.50mm thick pre painted galvalume zinc coating GI based corrugated steel sheet upto 3 mtr from the ceiling edge (f) Providing of galvanised sheet of suitable thicknes rain water gutter 200mm width and 150mm UPVC pipes as per design. (g) The shelter should be open from the front and rear side as per drawing. (h) The material provided for the pillars and at other places should be corrosion resistant. (j) The weather shelter to be painted externally with camouflage colour scheme . The inner surface of the roof and supporting pillars to be painted with anti-rust paint complete all as specified and as shown on drg:
Note : (i) Weather shelter floor area ( GSBC 300mm thick, WMM 225mm thick, DLC 125mm thick, HDPE film 400 micron & PQC 260mm thick, Expenslon joint ,Construction joint , Dummy Joints) paid and measured separately under respective items/ Schedule.(ii) Submission of 07 sets of Design calculation / details and drawings of Pre - Engineered Weather shelters duly vetted by IIT. (iii) Plinth height shall be 300 mm from GL.
Supply, installation and testing of mild steel motorised sliding gate for 26.6 mtr opening. The sliding gate consists of two panels, each panel shall be 18.00M in length and 2.10 M in height with bottom rail and roller shall be made of SS Gde -316 for sliding arrangement and 02 Nos Nylon roller on each guiding post to hold the sliding gate in position while opening and closing against any lateral movement complete all as specified and directed. The manufacturers specification also to be included for smooth functioning of gate:- (a) Gate should be accessible with electronic control panel with integrated manual all weather switch panel for heavy duty operations. ( b ) Easy key lock release through removable cover opening. (c) Internal provision of sensors for smooth operations during opening and closing of the gate. (d) Gate should have a rugged and powerful gear motor in each leaf of gate operated on 230V main power supply, for smooth operation of the gate alongwith its counter-weight. (e) Gate should have suitable opening/closing speed as per manufacturers specifications.
(f) Gate should be operated manually in case of power failure by key operating system. (g) Independent outdoor panel boards for on/off operations of the gate to be provided for each leaf of gate including elecrtic supply from nearby electric source.(h) spacing of vertical bars shall be 100mm c/c. Note : Submission of 07 sets of Design calculation /details and drawings of motorised sliding gate complete all as specified above duly vetted by IIT
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Construction of Tech Store and Guard room Building with permanent specification complete all as shown on drawings.
Construction of septic tank, including excavation of any type of soil, foundation in PCC 1:2:4, brick work with fly ash bricks in CM 1:4, RCC slab covers including RCC precast manhole cover having 6mm plate embedded al around/fibre reinfoced cover with angle iron frame vent shaft and sludge chambers etc for 10 users, complete all as specified and shown on drawings.
Construction of Soakage well including excavation in any type of soil, foundation in PCC 1:2:4, walls in honey combed masonary with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonaryin CM 1:4, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20M dia x 3.00 M effective depth, complete all as specified and shown on drawings.
NOTE: Schedule ‘A’ Part II to XII are under Ser No. 2.01 to 2.11 are Prepriced by MES.
Lump sum price worked out by the Contractor for “EXACAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORK ” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “ AREA DRAINAGE ” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for " PQC, APPROACH PATH, HARDSTANDING & ROAD WORKS” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION WORKS ” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “ FENCING & GATES WORKS” as listed in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for “ LIGHTENING PROTECTION WORKS” as listed in Schedule ‘A’ Part XI
Lump sum price worked out by the Contractor for “ DEMOLITION & DISMANTLING WORKS” as listed in Schedule ‘A’ Part XII
SCHEDULE `A' PART - XV MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 1.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia concealed type including all flame proof conduit fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 1.5 Sqmm and connected to earth dolly complete all as specified and directed.(Firing range and dragon loop)
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia concealed type including all flame proof conduit fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed
M&L for Earthing complete with galvanised steel earth plate electrode 60cm× 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including charcoal dust and common salt in alternate layers to a packed thickness of 15cm all around the earth plate, necessary excavation in any type of soil strata, returning filling and removal of surplus soil to a distance up to 50mtr, PCC pit in 1:3:6 type C1(using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (Using 20mm grade stone aggregate) 50 mm thick pit cover reinforced with 8mm dia TMT bars 75mm c/c, both ways, MS handle 12mm dia, GI funnel with wire mesh, GI watering pipe of 20mm bore (light grade) and earth lead protection pipe 40mm bore (light grade). Note: GI Strip and protection pipe upto 7.5 mtr is included in the unit rate and extra length if required shall be measured and paid separately.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth GI wire 4.0 by means of bolts, nuts, check nuts and washers of galvanised iron or steel including charcoal dust and common salt in alternate layers to a packed thickness of 15cm all around the earth plate, necessary excavation in any type of soil strata, returning filling and removal of surplus soil to a distance up to 50mtr, PCC pit in 1:3:6 type C1(using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (Using 20mm grade stone aggregate) 50 mm thick pit cover reinforced with 8mm dia TMT bars 75mm c/c, both ways, MS handle 12mm dia, GI funnel with wire mesh, GI watering pipe of 20mm bore (light grade) and earth lead protection pipe 15mm bore (light grade). Note: GI Strip and protection pipe upto 7.5 mtr is included in the unit rate and extra length if required shall be measured and paid separately.
M&L for Construction of platform for transformer of size 2.5 x 2.5 x 1.5 mtr with following specifications:- a) Earth work in soft/loose soil. b) 15 cm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as lean concrete in foundation. c) Brick work with sub class 'B' brick built in cement mortar 1:4. d) 75 mm thick PCC 1:2;4 type D2 using 20 mm graded aggregate over brick platform. e) Chain link on fencing post of size 40 x 40 x 6 mm of height 1.80 mtr at 2 mtr c/c around brick platform including excavation and earth work 30 cm embedded portion of angle iron in PCC 1;2;4 type B2 of size 60 x 60 x 60 cm. f) Chain link fencing of height 1.8 mtr made out of GI wire not less than 3mm and pitch not more than 75mm g) Angle iron gate using 40 x 40 x 6 m angle iron of size 2 x1.5 m with vertical flat 25 x 6 mm @ 10 com c/c including hanging & locking arrangement. h) 15 mm thick plaster in CM 1:6 on brick masonary platform. j) All exposed surfaces of steel work shall be given two coats of synthetic enamel paint over a coat of red oxide primer. j) Stair case of brick masonary for easy access to the plate form.
Supply, installing, testing and commissioning of outdoor type step down transformer, 11KV/433 volts AC three phase 50 Hz, 250 KVA capacity, core type double copper wound, oil immersed, naturally cooled, oil natural- Air natural (ONAN), with external cooling tubes/fines, delta connected on primary side (HV) and star connected to secondary side (LV) in accordance with vector group DYN 11 with neutral brought out on secondary side (LV side) and having tappings at + 5% in steps of 2.5% on HV side to be changed by the means of hand operated off load tap changing gear. Max Losses at 50% load shall not exceed 920W & max losses at 100% load shall not exceed 2700W complete. The max temperature rise should not exceed 45 deg celcius in oil and 55 deg celcius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40 deg celcius. the transformer shall be IS 1180 including initial filing of transformer oil conforming to IS-335 and shall comprises of following : (a) Three Nos procelain bushing suitable for 11 KV on HV side complete with brass/copper rods, nuts and washers and cable box
(b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods complete with nuts and washers, with cable glands suitable for reception/taking out of LT 1100 volts grade XLPE armoured cables including jointing materials complete. (c) Oil conservator with filter type drain valve and oil level gauge. (d) De-hydrating breather with first fill of dehydrating agent (Silica gel). (e) Exposion vent, thermometer pocket on tank cover, oil level gauge, oil drain filter, filter valve, lifting lugs/ jacks, oil filing hole with cap/ plug with connection plate complete, air release valve plug and 04 Nos plain solid cast steel deattachable rollers(f) 01 No dial type thermometer vapour pressure type having range 0 to 120 deg celcius. (g) Two earthing terminals on tank cover to facilitate fixing of 32x6 mm GI earth strip for body earthing (h) Rating plate and terminal marking plate (j) Extra bushing for netural in the LT cable box for providing indipendent set of earthing for netural. NOTE : (i) Rate also inclusive of providing tools and plants required for testing and commissioning of transformer by SEI.
Supply, installation, testing & commissioning feeder pillar box, outdoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including 630 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable complete comprising of following accessories all as specified and directed by the Engr-in-charge. (Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm):
Supply, installation, testing & commissioning feeder pillar box, outdoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including 400 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable complete comprising of following accessories all as specified and directed by the Engr-in-charge. (Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm)
Supply, installation, testing & commissioning feeder pillar box, outdoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including 250 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable complete comprising of following accessories all as specified and directed by the Engr-in-charge. (Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm)
Supply, installation, testing & commissioning feeder pillar box, outdoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including 250 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable complete comprising of following accessories all as specified and directed by the Engr-in-charge. (Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm)
Supply, installation, testing & commissioning feeder pillar box, outdoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including 150 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable complete comprising of following accessories all as specified and directed by the Engr-in-charge. (Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm)
Supply, installation, testing & commissioning feeder pillar box, outdoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including 150 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable complete comprising of following accessories all as specified and directed by the Engr-in-charge. (Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm)
S&F Non metallic Junction box made out of thermoplastic size not less than 28 cm xl7cmxl0cm hinged with lockable arrangement including aluminium bus bar TPN 32 Amp with provision of 01 No MCB SP 2.5 Amp rating , tapping of incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
Supply & fix bus bar chamber having four number aluminium bus bar mounted on insulator of capacity 63 Amp duly enclosed in sheet metal enclosure suitable for outdoor instgallation and fabircated from cRCA sheet 3.15 mm thick powder coated of size 450mmx450mmx300mm supported on angle iron of sizse 25x4mm base frame with 4-legs 450mm long each grouted in PCC and cable glands for in/out going cables all as specified and directed..
Supply and fixing two sided traffic light having a pair of red and green light on eachside, mounted on and including 4.0 mr heigh 100mm dia MS pipe medium grade pole. Traffic light should be illuminate with multi LED lamps 230 AC volts single phase, LED lamps 20 W be arranged in 300mm dia plate pattern covered with glass cover IP-65 protection including necessary PCC foundation and painting of pole with two coats of synthetic enamel paint over a coats of synthetic enamel paint over a coat of zinc oxide primer of colour as approved by GE.
S&F cable route indicator made out of mild steel plate of size 200mmx 200mmx 3mm thick fixed/welded to angle iron of size 25mmx4mm, 600mm long duly painted with two coat of synthetic enamel paint over a coat of zinc oxide primer and writing of cable details , grounted in PCC 1:3:6 type C-1 using 20mm graded stone aggregate block of size 150mmx 150mmx 150mm in foundation including necessary form work, all as specified and directed.
S&F complete control station start and stop with LED neon type pilot lamp green and red color LED based to operate traffic light enclosed in polycarbonate enclosure with mounting on wether shelter.
S&F LED light fitting 1x10 Watt, 220V, AC box type with driver, hollder connectign up with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed.
S&F Building security light fitting 20 watt, having uniformaty ratio 0.25, high pressuredie cast aluminium housing , heat resistant toughened glass with frame, IP66 protection complete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut bolts washer etc all as specified and directed.
S&F MCB SPN 32 AMPS, B Curve type 10 KA, 240 volts complete
S&F MCB TPN 100 AMPS, B Curve type 10 KA, 415 volts complete
S&F MCB TP 32 Amps, B Curve type 10 KA , 415 volt complete
S&F MCB SP 6 to 32 Amps, B Curve type 10 KA breaking capacity 240 Volts complete
S&F Triple pole and earth enclosure with athree pin and earth plug with socket complete with one triple pole MCB 32 Amps, 415 volts complete all as specified and directed.
Supply, installation, testing & commissioning of 11 KV outdoor mounted extendable fix (IP54) 1 LBS (incomer cum outgoing) with internal copper bus bars, consisting of 630 Amp fixed manual load break switch. All live parts busbar LBSs shall be enclosed in one tank to avoid mutiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank grade 304 of minimum 2.5mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. (i) The unit shall have front cable entry for rase of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. LBS should be complete with all accessories such as terminal boots, VIPS, cable supports all front cable terminations, mechanical indications for Load break switch ON/OFF.
Manometer as per with IEC standards 62271-200, 60056, 60265, 60298, 60420, 60529 and 60694. Altitude of installation upto 1000m as per IEC 60120. Extensible bushings if applicable shall be bolted type top mounted outside the tank for correction of external busbar. Also the outer enclosure shall cover the full length of the switch gear to ensure IP3X+IP54 proctection for cable boxes. (ii) The unit shall be internal arc proof 21 KA for 1 Sec for tank + cable box and tested and totally safe for human beings. (iii) Bidder shall provide test report to prove compliance to the internal fault IAC- AFLR as per IEC 62271-200. Internal arc proof & testing shall be done with enclosure door in open condition with switching devices in operation mode. The unit shall include the following with all necessary standard fitting required at site iv) 630 A Load break switch module for making of fault current alongwith Earth switch of full making capacity short time withstand current- 21 KA/ 3 sec, Making capacity - 52 KAp, Auxillary contacts - 1 NO + 1 NC
Power frequncy withstand voltage - 38 KV , Impluse Withstand voltage - 95 KV, Nominal operating gas pressure - 1.4 bar, Front cover mechanism - IP2X Cable covers - 3X, Snap action mechanism for manual operation, Cable box for front termination of the cable suitable upto 3 Core 95 sqmm, 11 KV XLPE cable right angle non-touch proof termination boots- 1 set (R,Y,B), (vi) Manual operated 630 A vaccum circuit breaker having spring stored mechanism . three position disconnector/ earthing switch downstream vaccum circuit breaker. Three position single spring mechanism for disconnector / earthing switch, Live cable LED indicators through capcacitive voltage dividers mounted on the bushings. short time breaking current - 21 KA/ 3 sec making capacity - 52.5 kAp, Auxiliary contacts 1 NO + 1NC
M&L for Construction of valves pit chamber of 60 x 60 x 60 cm internal size with one brick thick brick masonary wall in cement mortor(1:4),PCC foundation 10cm thick (1:4:8) type D2 with rendering 15 mm thick internally and top surface ,MS frame of angle iron 50x50x4mm and 3mm thick MS sheet cover with locking arrangement, hold fast, hinges including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessory excavation and earth work including dismantling of existing complete all as specified and directed.
M &L 300 mm thick GSBC (Granular Sub Base Concrete) grading I as per fifth revision of MoRTH specification over compacted subgrade in two layers of 150mm each graded crushed stone aggregate by providing close graded material mixing by any means as per site conditions, spreading in uniform layers with motor graded on prepared surface and compacting with viberator roller 8 -10 tonne capacity and maintaining the required density, grading and moisture content as per (fifth revision MORTH) specifications complete all as specified and directed.
M&L for GSBC (sub base) 150mm thick consolidated thickness in two layers 75mm each as per table 400 - 1 of MoRTH (5th revision) specification, spread, rolled with 8-10 capacity vibratory roller and consolidated to required gradient and camber in two layers complete all as spcd and directed.
M&L for 225mm WMM compacted thickness in three layers 75mm each grading as per fifth revision of MORTH specification, spread rolled and consolidation to gradient materials and camber required all as specified and as directed
M&L for 150mm thick (compacted thickness) wet mex macadum (WMM) using stone crushed aggregate of grading required as per table 400-11 of MoRTH (5th revision) specification laid in two layers 75mm each with mechanical means and rolling with 8-10 tonne poer roller over compacted sub base completed all as specified and directed. Note : (Mix will be prepared in mixing plant of suitable capacity)
M&L for providing 125mm thick DLC (dry lean concrete) design mix with 7 days compressive strength 10 Kg/Sq cm using crushed stone aggregate as in mass concrete using minimum cement 180 Kg/Cum including necessary steel form work including spreading, rolling and consolidating to required gradient and camber all as specified. NOTE:- No plus side price adjustment shall be applicable if excess quantity of cement content is required in the execution of work.
M&L providing pavement quality concrete (PQC) design mix 260mm thick with minimum flexural strength of 45 Kg per sqcm using minimum cement 400 kg/cum including using non circular synthetic fibre @ specified by the firmincluding form work for laying in bays complete all as specified & as shown on drg. Note :- (i) Construction joints, dummy joints (contraction joints) & expansion joints shall be measured & paid seperately under respective items (ii) Deduction shall be made in computing concrete quantity for expansion joints (iii) No plus side price adjustment shall be applicable if excess quantity of cement content is required in the execution of work. (iv) Polyster non-circular fibre as secondary reinforcement mixed in concrete shall be measured & paid as 'supply only' under relevent items of this schedule.
M&L forming 260mm depth and 25 mm wide expansion joint filled with compressive fillar board HD-100 provision of closed cell polyurethene grey sealent (minimum depth of sealent above back up rod shall be 12mm) conforming to BS-5212 (type FB) prming the site as recommended by manufactures instructions and applying tape on edge of joint to prevent accidental slippage of sealent and removing the masking tape after sealent is applied, the sealent should have MAF (-) (+) 30 and manufactures warranty of 10 years complete all as specified. Note: The joints shall be laid and filled as per IRC: 57-2018 and IRC: 15-2007 specification.
M&L forming construction joint 10mm wide and 25mm deep with diamond cutter and provision of closed cell polyurethene foam, back -up rod 12mm and sealed with 10mm (minimum depth of sealent above back-up rod) including pitch free polyurethene sealent conforming to BS-5212 (type FB) prming the site as recommended by manufactures instructions and applying tape on edge of joint to prevent accidental slippage of sealent and removing the masking tape after sealent is applied, the sealent should have MAF (-) (+) 30 and manufactures warranty of 10 years complete all as specified. Note: The joints shall be laid and filled as per IRC: 57-2018 and IRC: 15-2007 specification.
M&L forming contraction/dummy joint 6mm wide and 10mm deep with diamond cutter and provision of closed cell polyurethene foam back -up rod 8mm and sealed with 10mm (minimum depth of sealent above back-up rod) including pitch free polyurethene sealent conforming to BS-5212 (type FB) prming the site as recommended by manufactures instructions and applying tape on edge of joint to prevent accidental slippage of sealent and removing the masking tape after sealent is applied, the sealent should have MAF (-) (+) 30 and manufactures warranty of 10 years complete all as specified. Note: The joints shall be laid and filled as per IRC: 57-2018 and IRC: 15-2007 specification.
M&L finishing surface of concrete roads, pavement by brooming complete all as specified & directed.
M&L mooring rings complete all as specified and shown on draings No CEAF/STD-S-5/94 Sheet 1/5 to 5/5.
Supply only non circular polyster fibre as secondary reinforcement with circumcircle diameter 30-35 micron design for melting point 240-260 degree celcius hand having specific gravity of 1.34 to 1.4 recron @ 1 Kg /Cum of concrete.
S&F links sign boards made up of acrylic sheet 4mm thick cut to following size fixed with screws by giving backing rods inside boards. S&F backing strips for sign boards made up of tinted film as in approved colour as back ground and writing letters of size 30x5cm in capital viz, A,B,C,D,E,F,H,J,L,P,W1,Y2 on both sides of the boards. PVC pipes of first quality 50mm dia 4mm thick duly inserted with the 2nd class hard wood, 15cm length (two legs for each board) at the end to be grouted on ground by excavating any type of solid and providing PCC 1:2:4 at one end and the other end should be fixed with sign board by providing nut and bolts systems complete all as specified and directed :- (a) 60cmx60cm
M&L forming 75mm depth and 25 mm wide expansion joint filled with Compressive fillar Board HD-100 Provision of closed cell polyurethene grey sealent (minimum depth of sealent above back up rod shall be 12mm) conforming to BS-5212 (type FB) prming the site as recommended by manufactures instructions and applying tape on edge of joint to prevent accidental slippage of sealent and removing the masking tape after sealent is applied, the sealent should have MAF (-) (+) 30 and manufactures warranty of 10 years complete all as specified. Note: The joints shall be laid and filled as per IRC: 57-2018 and IRC: 15-2007 specification.
M&L forming construction joint 10mm wide and 25mm deep with diamond cutter and provision of closed cell polyurethene foam back -up rod 12mm and sealed with 10mm (minimum depth of sealent above back-up rod) including pitch free polyurethene sealent conforming to BS-5212 (type FB) prming the site as recommended by manufactures instructions and applying tape on edge of joint to prevent accidental slippage of sealent and removing the masking tape after sealent is applied, the sealent should have MAF (-) (+) 30 and manufactures warranty of 10 years complete all as specified. Note: The joints shall be laid and filled as per IRC: 57-2018 and IRC: 15-2007 specification.
M&L forming contraction/dummy joint 6mm wide and 10mm deep with diamond cutter and provision of closed cell polyurethene foam back -up rod 8mm and sealed with 10mm (minimum depth of sealent above back-up rod) including pitch free polyurethene sealent conforming to BS-5212 (type FB) prming the site as recommended by manufactures instructions and applying tape on edge of joint to prevent accidental slippage of sealent and removing the masking tape after sealent is applied, the sealent should have MAF (-) (+) 30 and manufactures warranty of 10 years complete all as specified. Note: The joints shall be laid and filled as per IRC: 57-2018 and IRC: 15-2007 specification.
M&L hot applied thermoplastic road marking inclusive type-I reflecting glass beads as per table 800-3, 800-4 of MORTH applied in uniform thickness of at least 1.5mm and spread uniformely with reflectorising glass beads type II @ 250 gms per sqm with a road marking machine as per IRC 35 complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid