| Sl No | Description | Qty | Unit | APOLLO TRANSFORMERS AND FILTERS L1 | R K ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Charges for disconnection of HV Power cable & its terminal box and earth flats. | 1 | No. | 1,800 ₹2,124 Lowest | 1,900 ₹2,242 |
| 2.00 | Charges for disconnection of LV Power cable & terminal box / LV bus duct terminal connection &Terminal Box. | 1 | No. | 3,710 ₹4,377.8 Lowest | 3,820 ₹4,507.6 |
| 3.00 | Charges for releasing the old transformer oil from tank and releasing the radiator cooling fins, valves and cleaning by using forced oil method. | 1 | No. | 7,715 ₹9,103.7 Lowest | 8,100 ₹9,558 |
| 4.00 | Charges for releasing the buchholz relay, conservator tank, vent pipe, oil & winding temperature gauges, disconnection of winding CT terminals. | 1 | No. | 6,220 ₹7,339.6 Lowest | 6,850 ₹8,083 |
| 5.00 | Charges for removing the top cover of the transformer and disconnecting the HV/LV leads from bushings and lifting the core and winding and checking any hot spot / arcing in HV/LV windings take off leads and joints. | 1 | No. | 5,150 ₹6,077 Lowest | 5,300 ₹6,254 |
| 6.00 | Charges for complete cleaning of the transformer tank, core, winding, and removing sludge & old gasket etc., | 1 | No. | 3,300 ₹3,894 Lowest | 3,500 ₹4,130 |
| 7.00 | Charges for complete cleaning and checking of the tap switch and attending defects if any. | 1 | No. | 4,440 ₹5,239.2 Lowest | 4,890 ₹5,770.2 |
| 8.00 | Charges for cleaning, servicing and replacing gasket to Buchholz relay, MOG, oil level gauge glass, explosion vent pipe, conservator tank, silica gel & diaphram. | 1 | No. | 7,475 ₹8,820.5 Lowest | 8,100 ₹9,558 |
| 9.00 | Charges for dismantling of HV & LV Bushings, cleaning, checking the bushing rods, replacing the deteriorated O rings & gaskets by new, assembling and fixing in the transformer tank | 1 | No. | 9,390 ₹11,080.2 Lowest | 10,100 ₹11,918 |
| 10.00 | Charges for repositioning of the core & winding assembly in transformer tank and reconnecting the HV/LV leads. | 1 | No. | 3,350 ₹3,953 Lowest | 3,850 ₹4,543 |
Tender Value
Refer Docs
EMD Value
₹1,700
Closing Date
11 Aug 2025, 2:00 pmClosed
Chief Engineer/TTPS
O/o CE/TTPS
ICHP- Overhauling, internal inspection, oil leak arresting by changing of all gaskets, tightness checking of HV LV windings, OLTC and allied works in 6.6KV 433V 2MVA Power transformer 2A in CHS-II.
2025_EB_585986_1
CE/SE/MI/TTPS/121/2025-2026
Open Tender
Miscellaneous Works
Works
45 days
TTPS
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1,700
Yes
3 Nov 2025
26 Jul 2025
12 Aug 2025
26 Jul 2025
11 Aug 2025
26 Jul 2025
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .