Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
REPAIR MAINT OF PANEL, EARTHING, LA AND LT CABLES, PANELS PAINTING AT VARIOUS LOCATIONS UNDER GE (MCTE) MHOW
2026_MES_769984_1
GE(MCTE)/MHOW/32(T) OF 2026-27
Open Tender
Electrical and Maintenance Works
180 days
GE (MCTE) Mhow
As per Tender Document
10 documents required · 10 mandatory
₹500
GE (MCTE) Mhow
₹60,000
Yes
5 Jun 2026
5 Jun 2026
1 Jul 2026
5 Jun 2026
29 Jun 2026
22 Jun 2026
Disconnecting & dismentling of damaged/unsv cable any type/ make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as specified and directed for following size:- (Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately)
(a) 25 Sqmm 3.5 core, complete all as specified and directed.
(b) 35 Sqmm 3.5 core, complete all as specified and directed.
(c) 50 Sqmm 3.5 core, complete all as specified and directed.
(d) 70 Sqmm 3.5 core, complete all as specified and directed.
(e) 95 Sqmm 3.5 core, complete all as specified and directed.
(f) 120 Sqmm 3.5 core, complete all as specified and directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 M wide and not exceeding 1.5 Mtr deep and getting out including filling bottom surface to required level or slope for laying of pipes/ cablescomplete all as specified and directed.
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft soil complete all as specified and directed.
Removing excavated surplus soil not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M&L for sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed. Note:- Punned thickness 18 cm shall be measured only.
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable including taking down old/ broken bricks complete all as specified and directed.
S&F for 50mm dia GI pipe 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/ pole or laid in trenches under road crossing/ hard standing including taking out old/ unsv existing pipe complete all as specified and directed. Note:- Excavation and earth work shall be measured & paid separately.
S&F for 80mm dia GI pipe 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/ pole or laid in trenches under road crossing/ hard standing including taking out old unsv existing pipe complete all as specified and directed. Note:- Excavation and earth work shall be measured & paid separately.
M&L for hiring Fault locator Megger machine, Locating fault in HT/LT UG cable of any size complete all as specified and directed. Note:- (i) All the instruments and T&P required for the above job shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) Contractor should be provide two labours for Joining and dismentling of cable at both the end and excavation above the faulty cable if required.
Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable straight trough heat shrink type joint complete with jointing material & accessories for 3.5 core XLPE cable of size 25 Sqmm to 50 Sqmm insulated armoured aluminium cable including taking down old unsv joint kit complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable straight trough heat shrink type joint complete with jointing material & accessories for 3.5 core XLPE cable of size 70 Sqmm to 120 Sqmm insulated armoured aluminium cable including taking down old unsv joint kit complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable straight trough heat shrink type joint complete with jointing material & accessories for 3.5 core XLPE cable of size size 150 Sqmm to 185 Sqmm insulated armoured aluminium cable including taking down old unsv joint kit complete all as specified and directed.
M&L for preparation of steel surfaces of indoor/ outdoor elect panel of any size/ type and removing dust, dirt by cleaning/ scrubbing inside outside as required, welding/ fixing and providing fresh hinges/ screw/nut bolts as required and fixing the panel door including painting the external surfaces with one coat of synthetic enamel paint without disturbing the existing fittings and fixture, changing of unserviceable voltmeter, ammeter, indicator lamp, proper taping to incomming outgoing LT UG conductor with flexible tape and insulation tape including marking and writing letter such as SM No. capacity etc. with safety precaution complete all as specified and directed.
Supply, installation and testing of factory made, CPRI Approved cubical outdoor type feeder pillar box 415 volt, 4 wire, AC 50 Hz, made out of 3.15mm thick CRCA sheet, weather and vermin proof powder coating finish bothside (interior & exterior) for outdoor mounting with having degree of protection as per IP-65 complete factory lock two earth terminal suitable cable gland for all incoming and outgoing and removable neutral link, Both Side openable double door Indicating light LED type RYB - 01 Set, Ammeter-01, Voltmeter-01, connecting strip/ solid conductor brought out to cable chamber brass/ copper nut, bolts/ washer etc including grouting of feeder pillar box 60 cm above ground level including suitable size angle iron stand made up of 65 x 65 x 6mm welded on all the four corner embedded in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) upto 30 cm including excavation and earth work complete including taking down unsv panel with following asseccories:- (a) Aluminium busbar high conductivity 800 Amp rated 4 phase including neutral bus bar complete - 01 No. Incoming :- (b) MCCB 4 -pole 400 Amp, 415 Volt, breaking capacity 36 KA, 50 HZ with thermal magnetic release - 01 No. Outgoing :- (c) MCCB 4 - pole 100 Amps breaking capacity 25 KA, 50 HZ - 02 Nos. (d) MCCB 4 - pole 63 Amps breaking capacity 25 KA, 50 HZ - 04 Nos. (e) MCCB 4 - pole 200 Amps breaking capacity 36 KA, 50 HZ - 02 Nos.
Supply, installation and testing of factory made, CPRI Approved cubical outdoor type feeder pillar box 415 volt, 4 wire, AC 50 Hz, made out of 3.15mm thick CRCA sheet, weather and vermin proof powder coating finish bothside (interior & exterior) for outdoor mounting with having degree of protection as per IP-65 complete factory lock two earth terminal suitable cable gland for all incoming and outgoing and removable neutral link, Both Side openable double door Indicating light LED type RYB - 01 Set, Ammeter-01, Voltmeter-01, connecting strip/ solid conductor brought out to cable chamber brass/ copper nut, bolts/ washer etc including grouting of feeder pillar box 60 cm above ground level including suitable size angle iron stand made up of 65 x 65 x 6mm welded on all the four corner embedded in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) upto 30 cm including excavation and earth work complete including taking down unsv panel with following asseccories:- (a) Aluminium busbar high conductivity 400 Amp rated 4 phase including neutral bus bar complete - 01 No. Incoming :- (b) MCCB 4 - pole 200 Amp, 415 Volt, breaking capacity 36 KA, 50 HZ with thermal magnetic release - 01 No. Outgoing :- (c) MCCB 4 - pole 100 Amps breaking capacity 25 KA, 50 HZ - 01 Nos. (d) MCCB 4 - pole 63 Amps breaking capacity 16 KA, 50 HZ - 07 Nos.
S&F MCCB 63 Amp, 4 pole, 415 Volt ISI marked conforming to 'B" curve, breaking capacity 16 KA complete including taking down old unsv MCCB complete all as specified and directed.
S&F MCCB, 4 pole, 415 volts, 400 Amps, breaking capacity 36 KA, with thermal magnetic release adjustable type including taking down old unsv MCCB complete all as specified and directed.
S&F MCCB, 4 pole, 415 volts, 630 Amps, breaking capacity 50 KA, with thermal magnetic release adjustable type including taking down old unsv MCCB complete all as specified and directed.
S&F MCCB, 4 pole, 415 volts, 250 Amps, breaking capacity 35KA/ 36 KA, with thermal magnetic release adjustable type including taking down old unsv MCCB complete all as specified and directed.
S&F MCCB, 4 pole, 415 volts, 200 Amps, breaking capacity 35KA/ 36 KA, with thermal magnetic release adjustable type including taking down old unsv MCCB complete all as specified and directed.
S&F MCCB, 4 pole, 415 volts, 160 Amps, breaking capacity 35KA/ 36 KA, with thermal magnetic release adjustable type including taking down old unsv MCCB complete all as specified and directed.
S&F MCCB, 3 pole, 415 volts, 100 Amps, breaking capacity 16 KA, with thermal magnetic release adjustable type including taking down old unsv MCCB complete all as specified and directed.
S&F for MCCB, 3 pole, 415 volts, 63 Amps, breaking capacity 25KA, with thermal magnetic release adjustable type including taking out existing old unsv MCCB complete all as specified and directed.
S&F MCB TPN, 4 pole, 415 volts, 63 Amps, 'B' curve 10 KA including taking out existing old unsv MCB TPN complete all as specified and directed.
M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6.0mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron 32 x 6mm strip as earthing lead protected by GI pipe light grade 40mm bore for protection of GI earth strip and 20mm dia GI pipe medium grade for watering with alternate layers of charcoal/ coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/ screened funnel and making brick masonry finished chamber of internal size 300mm x 300mm x 300mm with concrete base, covered with a cast Iron hinged cover resting over the cast iron frame painted with black bitumastic paint which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/ MCB DB for feeding the electric supply complete including taking down of old unsv earthing complete all as specified and as shown in electrical plate No. 3 of SSR Part-I and testing of earth resistance as required complete all as specified and directed. Note:- 7.5 RM strip wire upto 7.5 RM including unit rate.
M&L in Heat shrinkable LT sleeve for all incoming and outgoing cable of different sizes in LT Panel complete all as specified and directed.
Supply and fix Dew guard of size 150 x 150 x 2mm make HENSEL cat part no HDE 150 or equivalent make including taking down old unsv heater complete all as specified and directed.
S&F in replacement of protection relay Avana NPA 422 in 11KV VCB complete all as specified and directed.
Repair/ servicing of Battery charger including replacement of bridge rectifire of make SEMIKRON model no SKM400GB12T4 as per existing make & model with gate trigger circuit IC and ammeter (0-75 Amp) complete all as specified and directed.
Supply and spreading graded stone aggregate of size 40mm for transformer yard/ substation complete all as specified and directed.
Supply and filling (topping up) of transformer oil EHV as per IS 335 of 1983 Part-II after dehydration & testing complete all as specified and directed.
S&F in replacement of unserviceable CT in LT Panel of rating 200/ 5 Amp complete all as specified and directed.
S&F in replacement of unserviceable CT in LT Panel of rating 400/ 5 Amp complete all as specified and directed.
S&F in replacement of unserviceable Ammeter in LT Panel 0-60 Amp CT Operated complete all as specified and directed. Note:- Make as per existing size to avoid panel cutting work.
S&F in replacement of unserviceable Voltmeter in LT Panel 0-500 volt complete all as specified and directed. Note:- Make as per existing size to avoid panel cutting work.
S&F in replacement of unserviceable Seletor switch in LT Panel complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 32 x 6mm galvanised iron strip complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x15cm size including taking down, complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size including taking down, complete all as specified and directed.
M&L for WD-40 (Water Displacement, 40th formula) 500 ml for spray to clean Rust, lubricate, penetrate, protect against corrosion and displace moisture to panel/ VCB/ RMU etc. complete all as specified and directed.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
PS-32T.pdf
Tender Documents • 0.31 MB
Make32T.pdf
Tender Documents • 0.23 MB
TD32T.pdf
Tender Documents • 0.77 MB
Undertaking32T.pdf
Additional Documents • 0.10 MB
BOQ_862321.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid