Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1Accepted-Finance 1ST FLOOR FLAT NO 1A 29 2A 1A HAREY KRISTO SETT LANE KOLKATA 700050 | KOLKATA | KOLKATA | WEST BENGAL | 700050 | - | L1 | Accepted-Finance ACCEPTED |
| 2 | L1Rejected-Finance 2 MIRZA MAHEDI LANE 25 RAFI AHMED KIDWAI ROAD KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | - | L1 | Rejected-Finance REJECTED |
| 3 | L1Rejected-Finance 25 NO BALIA GARIA STATION ROAD KOLKATA 700 084 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700084 | - | L1 | Rejected-Finance REJECTED |
| 4 | L2₹5,800Rejected-Finance PO PAHALANPUR PS MADHABDIHI DIST BURDWAN PIN 713427 | HOOGHLY | WEST BENGAL | 713427 | ₹5,800 | L2 | Rejected-Finance REJECTED |
| 5 | L3₹43,000Rejected-Finance | ₹43,000 | L3 | Rejected-Finance REJECTED |
| Sl No | Description | Qty | Unit | SREE MAA ENTERPRISES L2 | BALAJI FIRE PROTECTION SYSTEMS L5 | B.S.A ENGINEERING L3 | UNIQUE FIRE PROTECTION SYSTEM L1 | ELECTRO FIRE PROTECT ENGINEERING & CONSULTANCY L6 | ALLEN MAX L1 | TRIPTI ENTERPRISE L4 | NABOUDYOG L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing one no attendant for 03(three) shifts for Fire Protection System for Round- o - Clock in 365 days in emergency towards smooth running of Fire Protection System. Rate is should be inclusive of all incidental charges, GST and all other taxes.
The Estimated rate has already been given (in Cell F13 of sheet 1 of BOQ) which is calculated considering prevailing minimum wages vide memo no. 20/Stat /14/RW/24/2023/LCS/JLC Dated. 17.06.2025 of Labour Commissioner, Govt. of West Bengal & also considering contribution to E.P.F.,E.S.I. & Bonus to be made by the Agency vide memo no. 3790-F(Y) Dated 21.07.2014 of Joint Secretary, Finance (Audit) Department, Govt. of West Bengal icluding GST 18% and 1% L.W.Cess.
Intending bidders are only required to quote the Service Charges in quoted rate in Cell M13 of Sheet 1 of BOQ. | 1,095 | Nos. | - | 50 ₹54,750 | - | - | 3 ₹3,285 | - | - | - |
| 2.00 | Deputation of Skilled Manpower atleast twice a month for intensive checking of all the pumps installed for firefighting system including sequential operation of those pumps to check the performance of each pumps. The job includes pump house and making necessary nominal rectifications/repair/replacement if required to ensure proper functionality of the fire pumps. Storage of Diesel to be checked and refilling to be done whenever necessary to ensure smooth operation of Diesel Engine driven pump during emergency. Mock Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit in every 15 days and report of the test to be submitted to PWD for record. | 12 | Month | - | 3,000 ₹36,000 | - | - | 3,000 ₹36,000 | - | 2,000 ₹24,000 | - |
| 3.00 | Butterfly Valve Supply, erection, testing and commissioning of ISI marked Butterfly valve of rating PN 1.6 with bronze/gunmetal seat complete with Nuts & Bolts, Gaskets conforming to IS 13095 of following sizes as required. 150mm NB (Wafer type)
100mm NB (Wafer type) | 4 | Each | 1,200 ₹4,800 | 3,600 ₹14,400 | 3,400 ₹13,600 | - | 5,500 ₹22,000 | - | 8,000 ₹32,000 | - |
| 3.01 | 100mm NB (Wafer type) | 1 | Each | 1,000 ₹1,000 | 2,700 ₹2,700 | 2,800 ₹2,800 | - | 3,800 ₹3,800 | - | 4,800 ₹4,800 | - |
| 4.00 | Supply,fitting and fixing of hydrant valve (ISI marked) with stand pipe and bend for outdoor hydrants as per specification and direction of the Engineer-in charge all complete. 150mm | 4 | Each | - | 4,500 ₹18,000 | 4,500 ₹18,000 | - | 21,500 ₹86,000 | - | 4,600 ₹18,400 | - |
| 5.00 | AIR RELEF VALVE Supplying, fitting and fixing cast iron Air Relief valve of approved brand and make bearing ISI marking tested to 21 kg per cm. Sqm.. 25mm NB with root valve (ball type) | 2 | Each | - | 1,800 ₹3,600 | 1,800 ₹3,600 | - | 4,800 ₹9,600 | - | 3,000 ₹6,000 | - |
| 6.00 | FAST RESPONSE SPRINKLER HEAD Supply, fitting and fixing pendent type fast response sprinkler head bearing ISI marking all complete. | 20 | Each | - | 400 ₹8,000 | 250 ₹5,000 | - | 550 ₹11,000 | - | 400 ₹8,000 | - |
| 7.00 | Inspection of entire hydrant system at least once in a month and submit report to PWD for any leakage or damage of hydrant/landing valves or any other type of valve andinstruments (water pipe lines etc.) for taking further course of action to ensure proper functionality of the installed fire protection system. The scope also includes minor repair / rectification of all type of valves such as replacement of damaged bolts and nutes with new one etc. Major rectification such as replacement of damaged hand wheel, flanges, perforated pipes, pipe supports, valve seat rings etc. to be done on chargeable basis with prior intimation to PWD. During inspection of water network,the vendor shall drain out water from risers and sprinkler lines and recharge it with set pressure after proper flushing. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water. The agency will held sole responsible if the Fire Hydrant Systems will not work in demand of emergency for any leakage or pilfarage of water from any parts of the fire hydrant system which has not brought into the knowlege of PWD by the working agency earlier. | 12 | Month | - | 3,000 ₹36,000 | - | - | 5,200 ₹62,400 | - | 1,000 ₹12,000 | - |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
12 Aug 2025, 3:00 pmClosed
Executive Engineer -I Alipore Division PWD
Executive Engineer_I Alipore Division PWD 2ND and 3RD floor 32_BELVEDERE ROAD Alipore Kolkata_700027
Providing attendant and routine check up for fire protection system at Multi storied office building Bhabani Bhaban under Alipore Division PWD during the year 2025_26
2025_WBPWD_882304_1
WBPWDEEIALI/IRT-09/25-26
Open Tender
CIVIL WORKS
365 days
ALIPORE
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,000
Yes
11 May 2026
24 Jul 2025
14 Aug 2025
24 Jul 2025
12 Aug 2025
24 Jul 2025
Amount
Deputation of Skilled Manpower atleast twice a month for intensive checking of all the pumps installed for firefighting system including sequential operation of those pumps to check the performance of each pumps. The job includes pump house and making necessary nominal rectifications/repair/replacement if required to ensure proper functionality of the fire pumps. Storage of Diesel to be checked and refilling to be done whenever necessary to ensure smooth operation of Diesel Engine driven pump during emergency. Mock Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit in every 15 days and report of the test to be submitted to PWD for record.
Butterfly Valve Supply, erection, testing and commissioning of ISI marked Butterfly valve of rating PN 1.6 with bronze/gunmetal seat complete with Nuts & Bolts, Gaskets conforming to IS 13095 of following sizes as required. 150mm NB (Wafer type) 100mm NB (Wafer type)
100mm NB (Wafer type)
Supply,fitting and fixing of hydrant valve (ISI marked) with stand pipe and bend for outdoor hydrants as per specification and direction of the Engineer-in charge all complete. 150mm
AIR RELEF VALVE Supplying, fitting and fixing cast iron Air Relief valve of approved brand and make bearing ISI marking tested to 21 kg per cm. Sqm.. 25mm NB with root valve (ball type)
FAST RESPONSE SPRINKLER HEAD Supply, fitting and fixing pendent type fast response sprinkler head bearing ISI marking all complete.
Inspection of entire hydrant system at least once in a month and submit report to PWD for any leakage or damage of hydrant/landing valves or any other type of valve andinstruments (water pipe lines etc.) for taking further course of action to ensure proper functionality of the installed fire protection system. The scope also includes minor repair / rectification of all type of valves such as replacement of damaged bolts and nutes with new one etc. Major rectification such as replacement of damaged hand wheel, flanges, perforated pipes, pipe supports, valve seat rings etc. to be done on chargeable basis with prior intimation to PWD. During inspection of water network,the vendor shall drain out water from risers and sprinkler lines and recharge it with set pressure after proper flushing. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water. The agency will held sole responsible if the Fire Hydrant Systems will not work in demand of emergency for any leakage or pilfarage of water from any parts of the fire hydrant system which has not brought into the knowlege of PWD by the working agency earlier.
ALLEN MAX (BID ID -6782844)
NABOUDYOG (BID ID -6800083)
SREE MAA ENTERPRISES (BID ID -6805785)
B.S.A ENGINEERING (BID ID -6826396)
TRIPTI ENTERPRISE (BID ID -6832111)
BALAJI FIRE PROTECTION SYSTEMS (BID ID -6808874)
ELECTRO FIRE PROTECT ENGINEERING & CONSULTANCY (BID ID -6796743)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
Tendernotice_2.pdf
PDF • 0.38 MB
BOQ_1989757.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid