Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹5.5 L+₹20,542.30 (3.84%)Accepted-Finance HOUSE NO 64 VILLAGE PALLA MASTER RISHAL SINGH WALI GALI DELHI NORTH WEST DELHI DELHI 110036 | NORTH DELHI | DELHI | 110036 | L2 | Accepted-Finance ok | |
| 3 | L3₹6.2 L+₹90,186.80 (16.9%)Accepted-Finance | L3 | Accepted-Finance ok | |
| 4 | L4₹6.5 L+₹1.2 L (21.6%)Accepted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | L4 | Accepted-Finance ok | |
| 5 | L5₹6.8 L+₹1.4 L (26.6%)Accepted-Finance | L5 | Accepted-Finance ok |
| Sl No | Description | Qty | Unit | RISHABH ENGINEERS L1 | Premier Engineering Company L6 | ROYAL ELECTRICAL CO. L3 | N.K. BUILDCOM L2 | GOGIA BROTHERS L5 | Devraj Enterprises L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Wiring of light point /fan point/ exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. | 148 | Points | 81,400 ₹81,400 Lowest | 1,46,520 ₹1,72,893.6 | 1,18,400 ₹1,18,400 | 88,800 ₹1,04,784 | 1,25,800 ₹1,25,800 | 1,40,600 ₹1,65,908 |
| 2.00 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 138 | Each | 57,960 ₹57,960 | 57,684 ₹68,067.12 | 55,200 ₹55,200 | 41,400 ₹48,852 | 62,100 ₹62,100 | 35,880 ₹42,338.4 Lowest |
| 3.00 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 in 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | 15 | Each | 5,700 ₹5,700 | 5,400 ₹6,372 | 4,500 ₹4,500 | 4,500 ₹5,310 | 5,250 ₹5,250 | 3,150 ₹3,717 Lowest |
| 4.00 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. | 180 | Meters | 28,620 ₹28,620 Lowest | 45,720 ₹53,949.6 | 32,400 ₹32,400 | 27,000 ₹31,860 | 32,400 ₹32,400 | 28,800 ₹33,984 |
| 5.00 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X4 sq. mm +1x4 sq. mm earth wire. | 360 | Meters | 68,400 ₹68,400 Lowest | 1,10,520 ₹1,30,413.6 | 86,400 ₹86,400 | 68,400 ₹80,712 | 79,200 ₹79,200 | 64,800 ₹76,464 |
| 6.00 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X6 sq. mm +1x6 sq. mm earth wire. | 270 | Meters | 67,500 ₹67,500 Lowest | 1,10,160 ₹1,29,988.8 | 81,000 ₹81,000 | 67,500 ₹79,650 | 75,600 ₹75,600 | 64,800 ₹76,464 |
| 7.00 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4x10 sq. mm +2x6 sq. mm earth wire. | 45 | Meters | 27,900 ₹27,900 | 30,150 ₹35,577 | 17,550 ₹17,550 | 15,525 ₹18,319.5 | 25,650 ₹25,650 | 13,950 ₹16,461 Lowest |
| 8.00 | Supply and fixing call bell/ buzzer suitable for single phase 230V, complete as required. | 4 | Each | 320 ₹320 Lowest | 360 ₹424.8 | 1,000 ₹1,000 | 600 ₹708 | 400 ₹400 | 1,040 ₹1,227.2 |
| 9.00 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 7 | Each | 1,960 ₹1,960 | 2,065 ₹2,436.7 | 2,450 ₹2,450 | 1,400 ₹1,652 | 2,205 ₹2,205 | 1,120 ₹1,321.6 Lowest |
| 10.00 | Installation, testing and commissioning of ceiling fan/wall fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. | 16 | Each | 4,080 ₹4,080 | 3,200 ₹3,776 | 2,400 ₹2,400 | 800 ₹944 Lowest | 4,000 ₹4,000 | 8,960 ₹10,572.8 |
Tender Value
Refer Docs
EMD Value
₹18,500
Closing Date
2 Nov 2026, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE EnM HP I
DELHI JAL BOARD GOVT OF NCT OF DELHI OFFICE OF THE EXECUTIVE ENGINEER EnM HP I HAIDERPUR WATER WORKS DELHI 110085
Renovation improvement of internal and external lighting arrangement of microbiology section, Zonal laboratory and Ist floor offices Main Admin block Haiderpur WW.
2026_DJB_300555_2
NIT NO. 11(2026-27) HP-I
Open Tender
Miscellaneous Works
Works
EE EnM HP I
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
SAB PAISA PORTAL Ac No. 50448339804
₹18,500
5 Nov 2026
27 Oct 2026
2 Nov 2026
27 Oct 2026
2 Nov 2026
27 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring of light point /fan point/ exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. | 148 | Points | - | - |
| 2 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 138 | Each | - | - |
| 3 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 in 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | 15 | Each | - | - |
| 4 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. | 180 | Meters | - | - |
| 5 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X4 sq. mm +1x4 sq. mm earth wire. | 360 | Meters | - | - |
| 6 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X6 sq. mm +1x6 sq. mm earth wire. | 270 | Meters | - | - |
| 7 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4x10 sq. mm +2x6 sq. mm earth wire. | 45 | Meters | - | - |
| 8 | Supply and fixing call bell/ buzzer suitable for single phase 230V, complete as required. | 4 | Each | - | - |
| 9 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 7 | Each | - | - |
| 10 | Installation, testing and commissioning of ceiling fan/wall fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. | 16 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_401183.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .