Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC BIHAR SHARIF NALANDA | ₹4.0 Cr | L1 | Accepted-AOC OK |
| 2 | L2₹4.1 Cr+₹9.4 L (2.36%)Rejected-AOC | ₹4.1 Cr+₹9.4 L (2.36%) | L2 | Rejected-AOC OK |
| 3 | L3₹4.3 Cr+₹26.6 L (6.67%)Rejected-AOC AT RANA SADAN KSHTRIYA NAGAR NEAR DEO HOSPITAL AURANGABAD | AURANGABAD | MAHARASHTRA | 423701 | ₹4.3 Cr+₹26.6 L (6.67%) | L3 | Rejected-AOC OK |
| 4 | L4₹4.4 Cr+₹44.4 L (11.1%)Rejected-AOC | ₹4.4 Cr+₹44.4 L (11.1%) | L4 | Rejected-AOC OK |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹4.2 Cr
EMD Value
₹4.2 L
Closing Date
4 May 2022, 5:00 pmClosed
CHIEF ENGINEER, JSRRDA
JSRRDA, 3RD FLOOR, FFP BUILDING, DHURWA, RANCHI, JHARKHAND
Construction and Maintenance of Roads
2022_CEJHR_117351_3
e-Tender No.- 03 /2022-23
Open Tender
Civil Works - Roads
Item Rate
300 days
CHATRA
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹4.2 L
Yes
14 Sept 2022
22 Apr 2022
5 May 2022
22 Apr 2022
4 May 2022
22 Apr 2022
Amount
Setting out etc all complete job as per specification and directioni of E/I
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical specification Clause 201.
Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
Construction of embankment with approved material obtained from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Compacting original ground supporting subgrade : Loosening of the ground upto level of 300mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Table 300.1 and 300.2 for sub grade construction as per Technical Specification Clause 303.5.2 SOR 3.15
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 250m as per Technical Specification Clause 301.5 (Free Lead )
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 250m as per Technical Specification Clause 301.5 (Lead upto 250m))
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
Construction of Cement Stabilized granular sub-base by Providing, laying and spreading well graded material on a prepared sub-grade, pulverising, adding the designed quantity (4% of Cement) of cement to the spread well graded material. Pulverising the treated mix with rotavator and tractor operated ripper in place method, grading with the motor grader and compacting with 8 to 10 tonne road roller at OMC to achieve the desired unconfined compressive strength and to form a layer of sub-base/base as per Technical Specification Clause 404. (II) For Grading II Material
Wet Mix Macadam (WMM) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. SOR NO4.9
Providing and applying Primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification
Providing and applying Tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared non-bituminous surfaces (cement concrete pavement) cleaned with Hydraulic broom as per Technical Specification Clause 503.
Semi Dense Bituminous Concrete (SDBC) with waste plastic Providing and laying semi dense bituminous Concrete with 100-120 TPH batch type hot mixplant producing an average output of 75 tonnesper hour using crushed aggregate of specified grading, premixed with bituminous binder @ 4.5 to 5 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tendem rollers to achieve the desired compaction as per MORTH specification clause No. 508 complete as per Technical Specification. SOR NO. B. 3.1
Construction of un-reinforced, dowel jointed at expansion and construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days
Panel cutting in concrete pavement in square panels of 1.25Mx1.25M (Maximum panel) sizes sawing in straight line up to 1/3rd depth from surface including labour and hireage of cutting machine inclusive of taxes under R & D projects in PMGSY
Providing and fixing of typical PMGSY informatory Sign Board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick top and middle plate duly welded with MS flat iron 25mmx5m size on back onedges. The lower plate will be welded with MS angle iron frame of 25mmx25mm x5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm x 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All MS will be stoe enameled on both sides. Lettering and printng arrows, border etc will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy as per drawing.
Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing SOR NO. 10.3
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing
Reinforced cement concrete M-15 grade 5th Kilometer stone (Precast)/Local stone of standard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703. SOR NO 10.10
Reinforced cement concrete M-15 grade Ordinary Kilometer Stone (Precast) stone/Local stone of stadard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.
Reinforced cement concrete M-15 grade 200m stone (Precast) stone/Local stone of stadard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.
Boundary pillar: Reinforced cement concrete M-15 grade boundary pillars/Local stone of standard design as per IRC:25 fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 704. (Boundary pillar/ FI Post) SOR NO. 10.10
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surface as per drawing and Technical Specification Clause 1701
Road Safety No of curves (Left - 15 & Right 17) Vide Annexure
Object marker in front of structure such as Culverts, bridges etc all complete job as per specification.
a) Left Turn curve (90 cm equilateral triangle)
b) Right Turn curve (90 cm equilateral triangle)
c) Zebra Crossing
e) Stop Board (60 cm circular)
f) Road narrow ( 80 mm x 60 mm rectangular)
g) Narrow Bridge( 80 mm x 60 mm rectangular)
g) Speed limit Board (Annexure attached)
h) Temple/Mosqe and other religious place
i) School
j) Speed Breaker
k) Village Board
HPC-1n x 1m Dia -2 Nos HUME PIPE CULVERT 1nx1m dia Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (SOR 11.1)
Plain cement concrete M-10 in levelling course below open foundation of head walls as per drawingand technical specification clause 1109 (SOR 11.4)
Stone Masonary in C.M.(1:4) in Foundation :-- Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203 (SOR 11.6)
Providing and laying 1000 mm Dia RCC pipe NP-3 for culverts on first class bedding of PCC M10 (1:3:6) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works,backfilling concrete and masonary works in head (SOR 9.3)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (PCC-1:2:4)
Plastring with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204 (SOR 12.3)
Providing 1.5 mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I
Stone masonry work in cement mortar in foundation (1:4) Rubble complete job as per drawing and technical specification clauses 702, 704, 1202 & 1203. . no. 11.6 (III) (ii)
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specification clause 802, 803, 1201 & 1203. (11.4 (ii) PCC Grade M-15
Plastering with cement mortar (1:4) 15mm thick on stone work in parapet as per technical specifications clause 613.4 abd 1208.4 SOR 12.3
1x6x3 m 1 No. Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone Masonary in C.M.(1:4) in Foundation :-- Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone Masonary in C.M.(1:4) in Sub Structure :-- Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
RCC M30 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M30) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone Masonary in C.M.(1:4) in Parapet :-- Stone masonry work in cement mortar (CM 1:4) in Parapet and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Pointing with cement mortar (1:3) :-- Pointing with cement mortar (1:3) on Stone Masonry work as per drawing and technical specification Clauses 613.3 and 1204
Providing back filling in foundation :-- Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
RCC Culvert 2n x 4m x 2.5m 1 No. Earthwork in excavation for structures as per drawings and technical spepcification clause 305.1 including setting out constgruction of shoring and bracing removal of stumps and other deleterious material and disposal upto a lead of 50m dressing of sides and bottom and backfilling in trenches with excavated suitable material. (RWD 11.1)
Filling (Sand) in foundation trenches as per drawing and technical specification Clause 305.3.9 (RWD SOR 11.2)
Providing and laying of dry rubble flooring complate as per drawings and technical specification Clause 1303.3 (SOR 14.8)
Stone masonry work in cement mortar in foundation complete job as per drawing and technical specification clauses 702, 704, 1202 & 1203. . RWD Item no. 11.6 (III) (ii) PCC M-15
Stone masonry work in cement mortar in foundation (1:4) complete job as per drawing and technical specification clauses 702, 704, 1202 & 1203. . RWD Item no. 11.6 (III) (ii) Coursed rubble masonary 2nd sort (1:4)
Stone masonry work in cement mortar in sub structure complete job as per drawing and technical specification clauses 702, 704, 1202 & 1204. RWD Item no. 12.4 (I) (i) Coursed rubble masonary 2nd sort (1:4)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (11.4) PCC M-20
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specification clauses 800, 1205 and 1205.5 (DECK SLAB M-30) (.RWD Item. no. 13.1 (ii)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specification clauses 800, 1205 and 1205.5 (WEARING COAT M-30) (.RWD Item. no. 13.1 (ii)
Supplying fitting and placing with HYSD Bar reinforcement (Fe 415) in sub structure complete as per drawing and technical specification clauses 1002, 1005, 1010 and 1202. (RWD SOR 12.8)
Pointing (1:3) on stone work in parapet as per technical specifications clause 613.4 abd 1208.4 (RWD SOR 13.19)
Providing and fixing Asphalt Plug in expansion joints in culverts, filling the same with bitumen, cement and sand etc. including cost of all labours and materials all complete as per MOST specification and direction of E/I.
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 (12.9)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 (RWD 10.11) S/F/F FI post -
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specification clause 802, 803, 1201 & 1203. (RWD SOR 11.4 (ii) PCC Grade M-15
Bailing out of water
MAINTENANCE For 1st Year
For 2nd Year
For 3rd Year
For 4th Year
For 5th Year
Labour Cess @ 1%
UMA SHANKAR SINGH
KVR INFRATECH
KOLESHWARI INFRACONS PRIVATE LIMITED
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .