| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC 05 BABA PALACE MUSRIGHARARI JANDAHA ROAD MUSRIGHARARI SAMASTIPUR BIHAR 848101 | SAMASTIPUR | BIHAR | 848101 | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹35.6 L+₹30,155 (0.85%)Rejected-Finance | L2 | Rejected-Finance not become lowest bidder | |
| 3 | L3₹36.8 L+₹1.5 L (4.18%)Rejected-Finance 792 2 A CIVIL LINES NEAR BABULAL MILL GWALIOR ROAD JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance not become lowest bidder | |
| 4 | L4₹36.9 L+₹1.6 L (4.57%)Rejected-Finance D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance not become lowest bidder | |
| 5 | L5₹39.2 L+₹3.9 L (11.1%)Rejected-Finance | L5 | Rejected-Finance not become lowest bidder |
Tender Value
₹41.2 L
EMD Value
₹82,500
Closing Date
17 Jun 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major Sunny Kumar Attri
Garrison Engineer Jhansi
SPL REPAIR TO BLDG NO P-113/01 TO 08 OF ORS MD ACCN AND OTHER SANCTIONED WORK UNDER AGE B/R- II UNDER GE JHANSI
2023_MES_597108_1
GE/JHA/TOK/45 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
Yes
GE Jhansi
₹82,500
Yes
14 Jul 2023
20 May 2023
19 Jun 2023
20 May 2023
17 Jun 2023
3 Jun 2023
20 May 2023 - 27 May 2023
Amount
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Demolition of cement concrete in ground floor including terrazo flooring and paving n exc 15cm thickness (below or above the ground level) built in cement mortar complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down eaves gutter and rain water pipes including all fittings any size and pattern complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and directed.
Taking down Chowkats or frames Not exceeding 1.5 Sq. M each (Without taking off shutters from the frame) complete all as specified and directed.
Taking down shutters of any description exc 1.0 Sqm but not exceeding 2.00 Sqm each complete all as specified and directed.
Demolition of RCC not exc 15cm thickness Roofs, floors (other than ground floors), beams staircases, landing, chajjas, Cover slab and similar suspended work complete all as specified and directed.
Demolition of cement concrete of any description and in any position of WC’s/Bathroom etc in sunken portion area above ground floor, removing demolished material completely and old waste pipe from sunken portion and cleaning the side/bottom surface of sunken floor with wire brush, complete all as specified and directed.
Removing existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime coba 80 to 100mm thick mud phuska/cement concrete/lime concrete etc, cleaning of all foreign material such as fungus. moss, dust etc, roughing surface of corner to roof by wire brush complete all as specified and directed.
Dismantling for Stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry and pointed in any mortar, complete all as specified and directed.
Dismantling water tank and removing to store exc. 250 litres & not exc. 500 litres capacity of tanks, complete all as specified and directed.
M & L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M & L Rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two layers (first coat 10 mm & second coat of 5 mm ) mixed with WPC as per manufacturers intructions, finished even and smooth without using extra cement complete all as specified and as directed. ( Note: Water proofing compound shall be measured & paid separately)
M & L Rendering 5 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed..
Preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over 1 mm putty and a coat of chalk whitening primer preparing to make the surface to be plain and smooth before primer complete all as specified and directed.
Preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
Complete removal of exisiting treatment, washing rubbing of old treatment and applying three coats of white wash on wall sufaces complete all as specified and as directed.
ditto as per item 21 above hereinbefore but in ceiling.
Complete removal of exisiting treatment, washing and rubbing of old distempered surfaces and applying two coats of oil bound distemper over 1 mm putty and a coat of chalk whitening preparing to make the surface to be plain and smooth before primer complete all as specified and directed.
Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified and as directed.
Preparation of old or previously treated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and as directed.
Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed.
Preparation of old or previously treated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete.all as sppecified and directed.
M&L for Coloured Glazed ceramic tiles 300x 450 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick redering in CM 1:4 on wall complete all as specified and directed..
M&L for jointless Virified Ceramic tiles (light shade) 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6.complete all as specified and directed
Ditto all as per item No 30 as above but in skirting including 10mm thick backing coat in CM 1:4 on wall complete all as specified and directed..
M&L for machine cut Kota stone slab flooring 20-25 mm thick and laid over and incl 20 mm thick screed bed in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab, with and including Cutting / Griding / mirror Polishing on Kota stone as per local trade practice, complete all as specified and directed.
All as per item here-in-above 32 but on vertical surfaces such as skirting/dado over 10mm thick CM rendering in CM 1:4. complete all as specified and directed.
M&L for Granite 20 mm thick over including 10 mm thick CM 1:4 (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rubbing and polishing complete all as specified and as directed.
M&L for 75mm PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection and path laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 finished even and smooth without using extra cement including forming joints 10 mm wide and upto full depth of PCC and filled with bitumen mastic (1:3) 1 part bitumen 85/25 and 3 parts of sand complete all as specified and directed. {Note:-Bitumen mastic will measured and paid seperately }
M&L for grade A forming construction joint 30 mm deep x 10 mm wide and filled with bitumen mastic all as specified and directed.
S&F in repair Aluminium Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed
S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, complete all as specified and directed.
S&F 20 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed. (minium weight 20 mm-210 gms) etc, complete all as directed.
S & F in repairs 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Ditto all as per item no 41 above but fixing only (Old pipe obtained from taking down shall be reused with provision of new fittings)
Ditto all as per item no 42 above but fixing only (Old pipe obtained from taking down shall be reused with provision of new fittings)
M&L for cutting chases,pinning in brick walls for concealed water tubing n.exc 10cm girth and making good facing where required and pointing in CM 1:3 complete all as specified and as directed.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste coupling, 32 mm PVC Waste pipe 600mm long complete all as specified and directed
Supply & Fix in repairs Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests including PCC bedding complete all as specified and as directed
Supply and Fix in repairs 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, low level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long and PVC 32 mm dia flush pipe complete all as specified and as directed
S & F in repairs 15 mm bore Bib taps, fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S & F in repairs 15 mm bore Bib taps long body fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S & F in repairs 15 mm bore stop/angle cock fancy type,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S & F in repairs 15 mm bore conceald stop cock fancy type,chromium plated with long shank and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F in replacement of pillar taps, 15 mm dia, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, complete all specified and directed.
S&F SS grating of square/round shape, overall size of 150x150mm with hinge type openable jali of 100 mm dia size with and incl fixing with CM to floor/nahani traps etc complete all as specified and as directed.
S&F in replacement of PVC connection 450 x 15mm dia PTMT (PVC), complete all as specified and as directed
S & F in repair Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed
S&F in repair SS Towel Rail 600mm Long fixed with and including chromium plated brass screws complete all as specified and as directed
S&F in repair of Brass CP connection 15mm dia and 45cm long with 2 Nos brass check nuts with washers for geyser, complete all as directed.
S&F of Ringfit PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall, complete all as specified and directed.
S&F of PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors, complete all as directed.
S&F of Ringfit PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall, complete all as specified and directed.
S&F of PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors, complete all as directed.
S&F 110 mm bore PVC (SWR) bends with access door of any radius, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore, jointing to waste pipe, complete all as specified and directed.
S&F PVC(SWR) vent cowl 110mm bore, jointing to waste pipe, complete all as specified and directed.
S&F PVC Nahani/ floor trap of 75 mm outlet, jointing to waste pipe, complete all as specified and directed.
M&L for mild steel framed work section as in door or gates of angle or other section with gusset plates,rails braces etc /windows chowkhats/Shutter frame of steel gate of grade Fe-290 (Gde E-165) including all necessary machine wks i.e. cutting, welding, grinding etc, complete all as specified and directed.
M & L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other bands, plinth courses, string cources, lacing cources, parapets and railing upto 60cm in hight, copings, kneelers, apex stones, bed plates, water troughs, hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
S & F for window shutters 35mm thick Second class hard wood (sal) glazed & skelton shutters ,open rebated, prepared to receive glass, gauze etc,without shash bar edge of framing plain, chamfered or rounded, fitted with cut or mitred beads for securing glass, gauge etc sizes of members of shutters as specifed in SSR Part-I section 8 clause 8.24(a) supplied and fitted to chowkhats all as specified and directed.
S & F 30mm thick flush shutter, solid core construction with block board core and ply wood panels commercial type on both side complete all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm (± 5 mm tolerence in dimension) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)., supplying & fixing in opening as per specification & drawing complete all as specified in SSR Part-II 2020 section 8.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid moulded flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F 18/19mm thick pre-laminated particle board , exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work for cupboard shutter complete all as specified and directed by Engr-in-charge
S&F in repair Block boards 18/19mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete as per the specifications and as directed by the Engineer - in -charge.
S&F Window ECO 4000, of double rebate openable/fixed window made of galvanised steel colour coated/powder coated (base steel as per IS 513 Of 'D' quality, galvanised as per IS 277 with zinc of 120 gms/sqm) with total thickness of coating 0.58 microns thick and back coated with alkyd backer 5-7 micron thick or powder coated with pure polyster powder up to 50-60 micron thick. Outer frame section 72 x 55 mm , center mullion section 72 x 50 mm, shutter section 47 x 20 mm, fly mesh section 40 x 20 mm and the fixed glass beading section 12 x 12 mm, outer frame and mullions shall consist rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the section cut to length mitre joined with corner bracket, center millions fixed with mullions cap, stay, handle, latch, 2 nos of heavy duty stainless steel pivot hinges per shutter and paneled with 5 mm thick plain float glass and S. S. mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propyelene Diamine Monomer) gaskets including fixing windows in the Concrete /Masonry wall by means of self expanding screw, including 10 mm square bars welded to 6 x 12 mm flat at a distance 150mm C/C (Pitch) etc complete all as specified and as directed.
S&F Box type steel Ventilator with 80x40x1.25mm RHS frame with side hung shutters (double shutters for glass and gauze) with out sash bars jointed together with and including grills using 12mm square bars @ 10cm C/C Ref TD No CEBZ/TD/14/ 2011 including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed by the Engineer-in-Charge
S&F Continuous (piano) hinges, mild steel, 30 mm width of flap (when open), bright finish or electrogalvanised, complete all as specified and directed
S&F magnetic catcher for fixing in cupboard, to hold the shutter in closed position, complete all as specified and directed
S&F of 100mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws or welded to angle frame, complete all as specified and directed.
S&F of 75mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws or welded to angle frame, complete all as specified and directed.
S&F of 200 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed with screws, complete all as specified and directed.
S&F of 150mm long mild steel pressed handles, oval type, stove enamelled black and fixed with screws, complete all as specified and directed.
S&F of 300mm long mild steel, sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and incl minimum of 6 bolts and nuts, complete all as specified and directed.
S&F 200 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F of 150mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.
S&F of 100mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.
S&F of 150mm aluminum handle cast type anodized complete all specified and directed.
S&F of 100mm aluminum handle cast type anodized complete all specified and directed.
S&F of mild steel ordinary rat tail rod pattern springs of size 300mm including roller and roller plate complete all as specified and directed
S&F for Door stopper 140 mm of aluminium alloy body anodised with tongue of rubber bush at one end fixed to door complete all specified and directed.
S&F Rubber bush of 25mm long fixed to door complete all specified and directed.
S&F 125 mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
S&F 3mm thick sheet glass frosted/figured and pin headed glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
M&Lin repair for stainless steel curtain rod 25mm dia with caps/lobs and wall mounting bracket cutting in to length required at site complete all specified and directed.
S & F for stainless steel kitchen plate rack size 750x 600x230 mm including fixing arrange ment to walls with rawel plug or wooden plugs complete all specified and directed.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste cupling, wastepipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all specified and directed.
Supply only integral liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as directed. Make : Dr Fixit LW + Professional or equivalent of Fosroc / Sika
M&L for RCC M-25(Design Mix) (using 20 mm graded stone agg) as in beams, lintels and like exceeding 1.5 metre claear span complete all as specified and directed
M&L for RCC M-25(Design Mix) (using 20 mm graded stone agg) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
All as per item no 106 above but for chajja only complete all as specified and directed
M&L for mild steel deformed TMT bars 8 mm To 10mm dia (as in reinforcement) cut to length, bent to shape require including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed
Form work to flat soffits of suspended slabs such as roof slabs, floor slabs and lintels, landingand similar work n exc 200mm thick complete all as specified and directed
Form work to flat chullah hoods, chajjas, troughs and similar items including edges etc. complete all as specified and directed
Form work to sides and soffits of flat floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed
Ditto, as per item no 112 above but exc 5cm but not exc. 10cm wide
M&L for 15mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces mixed with liquid water proofing solution to vertical surface complete all as specified and directed Note:-liquid water proofing solution shall be provided in 150ml in 50 Kg of Cement by weight and cost of liquid water proofing solution shall be measured and paid seperately
M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in padding levelling etc and roof kerbs with liquid water proofing solution finished even and fair with proper slope as prepatory works to water proofing treatment complete all as specified and directed Note:-liquid water proofing solution shall be provided in 150ml in 50 Kg of Cement by weight and cost of liquid water proofing solution shall be measured and paid seperately
M&L for application/forming of waterproofing liquid membrane moistening the prepared surface for proper dispersion and penetration and applying two component cementitious elastomeric water proofing coating damp block 2k as per manufacturers specifications. The treatment shall be carried out to the entire bottom surface and vertical surface upto the bottom height of wall tiles. Adequate curing to be done on vertical surfaces and ponding test for 48 hours on the bottom surface to be carried out complete all as specified and directed. Make :- M/s Asian paint, M/s fosroc, Berger home shield or equivalent makes approved by E-in-Cs branch. NOTE : (a) Treatment shall be done through authorised applicator/representative of the manufacturer only. (b) Warranty for water proofing to be submitted by the contractor as per manufacturer norms
M&L PCC 1:5:10 Type E2 using 40mm graded stone aggregate as in mass filling in two layer in sunken portion complete all as specified and directed
.M&L 50mm dia G.I pipe as in spout to drain out if any leakage occures in the sunken portion complete all as specified and directed
Material & labour for cleaning of plastered /concrete surfaces and applying priming coat using bituminous primer @ 0.30 Kg/Sqm. followed by evenly a tack coat @ 1.20 Kg/Sqm. using with 85/25 grade bitumen, over laid with 3mm thick APP modified polymeric water proofing membrane with non woven polyester reinforced of weight not less than 3.6 Kg/Sqm. unrolled and bonded to substance with side and end laps 75mm and 100mm as per manufacturer’s instructions and finished top of APP water proofing polymeric membrane with a coat of hot blown industrial bitumen 85/25 grade @ 1.20 Kg/Sqm and finally finished with a coat of bituminous aluminium paint @ 0.20 Kg/Sqm complete all as specified and directed.
Demolition of brick/stone masonary built in cement mortar incl all quoins arches pillars etc complete all as specified and directed
M&L for brick work with sub-class B bricks straight or curved on plan exc 6 Mtr mean radius built in CM (1:6) complete all as specified and directed
S & F in repair single lever brass CP wall mixer 3-in-1 system with provision for over head shower with 115 mm long bend pipe, connecting legs and wall flange (without overhead shower) shower for iron pipe of 15 mm bore GI pipe complete all as specified and directed.
S&F of toughned glass corner shelves Shelf of size 300x300 mm fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.
Preparing newly plastered surfaces of wall and applying two coats of weather proof exterior grade emulsion over and including a coat of primer complete all as specified and directed.
Complete removal of exisiting treatment, washing and rubbing of old surfaces of wall and applying two coats of weather proof exterior grade emulsion over and including a coat of exterior grade cement based primer complete all as specified and directed.
M&L 75 mm thick cement concrete type C2 1:3:6 (using 40 mm graded stone agg) in sub base of flooring/ hard standing complete all as specified and directed.
M&L for factory made PU coated, machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with coloured pigment made of rubber moulded with vibrating system, with and including 50mm thick sand cushioning, including in CM (1:3) in edges of pavers, complete all as specified and directed.
Excavating in trenches not exc 1.5m wide & not exc 1.5m depth for foundation etc or for shafts, wells, cesspits, manholes etcand getting out in any type of soil complete all as specified and directed.
Demolition and breaking up of drains pipe (Salt glazed stone ware, AC or reinforced concrete) set in cement mortar 150 mm internal dia pipe complete all as specified and directed.
M&L 150mm reinforced concrete pipes, class NP2, laid and jointed with skeins of spun soaked in neat cement wash shall be inserted in the grooves at the ends of the pipes, the two adjoining pipes put against each other the collar is slipped over the joint covering equally both the pipes, more skiens of spun yarn soaked in cement wash shall be passed round the pipes and inserted in the joints by means of caulking tools after that cement mortar 1:2 slightly moistened shall be inserted in the joints finished in 45 degree slope complete Note:- After curing 7 days to the joints the sewage pipe shall be tested as per procedure laid down for water test.
M&L concrete bed to drain pipe for 150 mm dia pipes in PCC (1:4:8) type D2 using 40 mm graded stone aggregate incl packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Returning / filling in incl spreading, levelling, watering and well ramming in layers not ext 150mm thick as in Hard/dense soil complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m complete all as specified and directed.
M & L cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm internal dia of pipe complete all as specified and directed.
Precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs set in cement mortar 1:6 complete all as specified and directed.
Dismantling Asbestos Cement Corrugated or Semicorrugated in Roof covering, complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in concrete, brick work, masonry etc. including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling of Framed timber scantling 40sq cm and over in section in any position complete all as specified and directed.
S&F of pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based corrugated / semi corrugated / trapezoidal steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed.
M&L for structural steel Fe-410-W(Gde-E-250) quality B for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed.
M&L for point wiring for modular fittings complete with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of modular concealed GI boxes and cover plates with frames and 1.50 sq mm PVC insulated unsheathed stranded copper conductor (FRLS) cable for common earth and connecting to earth dolly all as specified and directed by Enrg-in-charge. (Note- rates of chasing/cutting & making goods shall be included in the unit rate) :-
One light point controlled by one switch
One Exhaust fan point controlled by one switch.
One ceiling fan controlled by one switch and one regulator
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per srl item no.141 here-in-before but with 4.0 sq mm FRLSH copper wire with 4.0 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 6 sqmm + 1 run x 6 sqmm with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item no. 143 here-in-before but 2runsX4 Sqmm +1runX4Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
Notes for item No. 141.00 to 144.00 (i) Quoted rate shall deemed to incude the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & caping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing caping may be used in that portion.
Supply and fix Modular switch 1 way 6A, 1 module 240V, 50Hz with required modular white cover plate with frame complete all as specified and directed.
Supply and fix Modular switch 1 way 16A, 1 module 240V, 50Hz with required modular white cover plate with frame complete all as specified and directed.
Supply and fix Modular Socket 6A/16A - 2/3 pin combined 2 module 240V, 50Hz with required modular white cover plate with frame complete all as specified and directed.
Supply and fix Modular Socket, 6A - 2/3 pin combined 2 module 240V, 50Hz with required modular white cover plate with frame complete all as specified and directed.
S&F Modular angle holder, metal cased, bakelite body, 240 volts, complete all as specified and directed.
Supply and fix Modular Bell push 6A 1 module, 240V, 50Hz with required modular white cover plate with frame complete all as specified and directed.
S&F electric bell of DINGDONG type, 240 volts, single pole and making all necessary connections, complete all as specified and directed.
Supply and fix Modular fan regulator step type in 5 steps, 240V, 50Hz with required modular white cover plate with frame complete all as specified and directed.
S&F, Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.
S & F 12W White LED retrofit lamp suitable for B-22 holder base with polycarbonate diffuser and aluminium heat sink.
Supply and fix in replacement of integrated LED batten 20 watt, 4 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed.
Supply and fix in replacement of integrated LED batten 10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed.
Supply and fix in replacement of Decorative wall light fixture made up of Polycarbonate with and including 7W retrofit LED lamp, full white of approved model including taking down existing unserviceable light fitting of any description complete all as specified and directed.
Supply and fix in replacement of sleek square recessed cum surface mounting LED down light 24 W with aluminium die-cast body, finish with drop down PC diffuser warm / full white with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed.
Supply and fix LED building security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP 65degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of LED bulkhead luminaire 10W in die-cast aluminium alloy/ PVC body heat resistant prismatic glass cover, with specially designed gasket for minimum IP 55 degree of protection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.all as per cat number LEDPN36 - E((CW) 1 x 4 of HPL or eqvt in Philips or Bajaj complete all as directed by Engr- in - Charge.
Supply and fix in replacement of LED garden light fitting 15/20 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on ground/walls with pcc coping 1:2:4 using 20 mm size stone aggregate upto 30 cm and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from electric source to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed.
Supply and fix LED strip, 24 watt, warm / cool white, 40 mtr length, flexible PCB body type including driver, IP 20 protection with accessories such as 06A plugtop, flexible cable etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED post top lantern light fitting 20/25 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv and complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of 25mm dia medium grade GI pipe of length 0.50m bent to required shape and fixing on ground/walls with pcc 1:2:4 using 20 mm size stone aggregate upto 30 cm and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from electric source to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed.
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC conduit including fitting such as tee,elbow,bend etc 20mm dia ISI (MMS)grade, incl taking down old unserviceable conduit all as specified and directed.
Supply and fixing in replacement PVC casing Caping tee, elbow,bend etc 20/25 mm dia ISI ISI (MMS) incl taking down old unservecable casing caping all as specified and directed.
Supply, installation, commissioning of Glass Top Deep Freezer, 320 Ltr single phase 240 volt, 50 Hz all as specified and directed by Engineer-in-Charge.
Supply and install air conditioner hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge.
Supply and installed refrigerators, electric driven (single phase), capacity 320 litres frost free inverter type all as specified and directed by Engineer-in-Charge.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.
M&L for Point wiring with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass /GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-
One light point controlled by one switch
One Exhaust fan point controlled by one switch.
One ceiling fan controlled by one switch and one regulator
One Bell point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per srl item no. 173.00 here-in-before but with 2.5 sq mm FRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
Notes for item No. 172.00 to 173.00 (i) Quoted rate shall deemed to incude the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & caping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing caping may be used in that portion.
S&F, Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
S&F, Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
S&F, Socket, 6 pin, 6/16 Amp, multipurpose 240 volts, complete all as specified and directed.
S&F, Socket, two-in-one, 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed.
S&F, angle holder, metal cased, bakelite body, 240 volts, complete all as specified and directed.
S&F Bell push switch, single pole, one way, 6 Amps, 240 volts, complete all as specified and directed.
Supply and fix electronic fan regulator in 5 steps, 240V, 50Hz complete all as specified and directed.
S & F 7W White LED retrofit lamp suitable for B-22 holder base with polycarbonate diffuser and aluminium heat sink complete all as specified and directed.
Supply and fix MCB distribution board, TPN, 4 way 415 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply and fix MCB distribution board, SPN, 8 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
S& F MCB TPN 63 Amp, 10 KA, 'C' curve, 415 V, 50 Hz all as specified and directed
S& F MCB SPN 40 Amp, 10 KA, 'C' curve, 230 V, 50 Hz all as specified and directed
S& F MCB SP 6-32 Amp, 10 KA, 'C' curve, 230 V, 50 Hz all as specified and directed
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing unserviceable service cable of any description complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply and fix in replacement of Hot Press Molded SMC meter box of size not less than 700mm x 480mm x 210mm for accommodating 04 Nos of Single Phase energy meters including cutting the wall surfaces for flush mounting of meter box and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
NATIONAL AUTO MOBILES
V K Engineers and Associates
FTH Traders
Soni Traders
M/s JS Constructions
m/s ramesh saran agarwal
M/S Kesav Dev Agarwal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .