Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹34.4 L+₹84,745.84 (2.53%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹35.6 L+₹2.1 L (6.24%)Rejected-Finance 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹37.4 L+₹3.8 L (11.4%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹40.1 L+₹6.5 L (19.4%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
| Sl No | Description | Qty | Unit | Deccan Enterprises L3 | KESARI AND SONS L6 | metro electrical services L7 | Sparkh Electricals & Works L2 | Mepcon Projects Pvt LTd L5 | G V HAGAWANE L1 | Shriyansh sales and services L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair / maintenance of street / security lights any type, flood lights, post top lanterns or any other external lights in its position fixed on pole /building structure or by taking down to ground, if required, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like electronic driver,surge protection device (SPD) connection wires/ cable, MCB etc including refixing the fitting to its original position (if taken down), including repair / maint of street light control timer & junction box all as directed .
Note:
(i) The rate against the above mentioned item is deemed for cost of labour and allied expenses only.
(ii) Cost of spares electronic driver, connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below.
(iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defective street light fittings and will submit the completion report on the same day before 1730hrs to the JE E/M.
(iv) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments and clothings to his men and department shall not be responsible for any kind of mishap / accident / injury to his men.
(v) The contractor has to rectify the defects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M. In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall carry out repair / maint work simultaneously JCOs/OR and followers residential area by engaging seprate team of electricians / technicians in order to ensure promptly & timely rectification of defects.
(vi) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for.
(vii) The contractor shall maintain sufficient stock of spares / material required for repair / maint of street lights with the concerned JE E/M against the supply only items here-in-below.
(viii) The details of street / security lights is enclosed as Appx A to Schedule A for general idea about the location and type of light fittings. (ix) Minimum 2x Electricians should be deployed to attend the complaints to ensure dusk to dawn serviceability of Street lights and ensure alternate arrangements to make fittings functional all as specified and directed | 1,500 | Each | 65 ₹97,500 | 127 ₹1,90,500 | 45 ₹67,500 Lowest | 65 ₹97,500 | 55 ₹82,500 | 45 ₹67,500 Lowest | 250 ₹3,75,000 |
| 2.00 | Taking down the existing light fittings on multi mounting brackets from 16/21 mtrs highmast pole by taking on ground repairs/ replacing the defective parts like electronic drivers connection wires and refixing the same to its original position all as directed by Engr-In-Charge. Note:
(i) Cost of spares , electronic drivers,connection wires replaced against above mentioned item above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (ii) The defects / repair of the floodlight making them functional after handing over defective floodlights of highmast
(iii) Maintaining proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every flood light and getting it authenticated. (iv) Safety of his men engaged for executing the work along with safety equipment and clothes for the men shall be maintained. | 100 | Each Job | 185 ₹18,500 | 499 ₹49,900 | 290 ₹29,000 | 200 ₹20,000 | 550 ₹55,000 | 175 ₹17,500 Lowest | 600 ₹60,000 |
| 3.00 | Supply only following street light spares of branded make as mentioned in the list of make enclosed with Particular specifications for replacement under respective item above :-
(a)Electronic driver suitable for 90watts LED security light fittings Make should be as per the Existing manufacturer. | 150 | Each | 115 ₹17,250 | 100 ₹15,000 Lowest | 450 ₹67,500 | 380 ₹57,000 | 660 ₹99,000 | 375 ₹56,250 | 350 ₹52,500 |
| 4.00 | (b) Electronic driver for 30/40/ 45 / 48 / 50/60 watts LED road way/Flood light/post top Make should be as per the Existing manufacturer | 200 | Each | 145 ₹29,000 | 100 ₹20,000 Lowest | 315 ₹63,000 | 250 ₹50,000 | 330 ₹66,000 | 555 ₹1,11,000 | 110 ₹22,000 |
| 5.00 | (c) Electronic driver for 400/300 watts flood lights Make should be as per the Existing manufacturer | 15 | Each | 295 ₹4,425 Lowest | 300 ₹4,500 | 945 ₹14,175 | 700 ₹10,500 | 1,320 ₹19,800 | 475 ₹7,125 | 310 ₹4,650 |
| 6.00 | (d) Electronic driver for 200 watts flood lights Make should be as per the Existing manufacturer | 15 | Each | 95 ₹1,425 Lowest | 300 ₹4,500 | 855 ₹12,825 | 450 ₹6,750 | 990 ₹14,850 | 455 ₹6,825 | 310 ₹4,650 |
| 7.00 | (e) All as item No 3 above but Electronic driver for 150 watts flood lights Make should be as per the Existing manufacturer | 12 | Each | 95 ₹1,140 | 250 ₹3,000 | 720 ₹8,640 | 290 ₹3,480 | 77 ₹924 Lowest | 355 ₹4,260 | 310 ₹3,720 |
| 8.00 | (f) Electronic driver for 100 watts flood lights Make should be as per the Existing manufactureAll as item No 3 above butr | 10 | Each | 95 ₹950 Lowest | 200 ₹2,000 | 450 ₹4,500 | 310 ₹3,100 | 660 ₹6,600 | 255 ₹2,550 | 240 ₹2,400 |
| 9.00 | (g) MCB SP 230 volts B curve 6 amps | 200 | Each | 115 ₹23,000 | 79 ₹15,800 Lowest | 120 ₹24,000 | 120 ₹24,000 | 99 ₹19,800 | 100 ₹20,000 | 110 ₹22,000 |
| 10.00 | (h) MCB DP 230 volts C curve 6 amps | 50 | Each | 115 ₹5,750 Lowest | 170 ₹8,500 | 250 ₹12,500 | 460 ₹23,000 | 198 ₹9,900 | 200 ₹10,000 | 260 ₹13,000 |
Tender Value
₹48.0 L
EMD Value
₹96,000
Closing Date
17 Oct 2025, 6:00 pmClosed
GE Khadakwasla
GE Khadakwasla
REPAIR/MAINT OF STREET LIGHTS ,SECURITY LIGHTS , HIGH MAST LIGHTS/FACADE LIGHTS,GARDEN LIGHTS, POST TOP LANTERN AND ALLIED WORKS ZONE B AT NDA KHADAKWASLA..
2025_MES_732023_1
8992/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE Khadakwasla
As per Tender documents
9 documents required · 9 mandatory
₹500
GE Khadakwasla
₹96,000
Yes
22 Nov 2025
22 Sept 2025
20 Oct 2025
22 Sept 2025
17 Oct 2025
5 Oct 2025
22 Sept 2025 - 5 Oct 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.49 MB
Tender Documents
Tender Documents • 0.95 MB
BOQ
BOQ • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .