Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34 LAccepted-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹41.6 L+₹6.3 L (17.8%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹43.2 L+₹7.9 L (22.5%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹45.4 L+₹10.1 L (28.7%)Rejected-Finance STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹49.5 L+₹14.2 L (40.3%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
26 Apr 2024, 6:00 pmClosed
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIRS AND MAINTENANCE OF INTERNAL WIRING, FITTINGS AND FIXTURES AND CONNECTED ITEMS AS WELL AS ATTEND MAINTENANCE PROGRAMME FOR Md ACCN AND OTM ACCN AT NEW CANTT AREA UNDER GE(N) PATIALA AT MIL STN PATIALA
2024_MES_648380_1
GE (N)/TOKEN-05/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹96,000
Yes
8 Jun 2024
29 Mar 2024
29 Apr 2024
29 Mar 2024
26 Apr 2024
12 Apr 2024
Amount
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of walls, ceiling etc all as specified and directed Engr-in-charge.
M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer in-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. Note:- V- Rate of cutting chasing included in the unit rate quoted for this item
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light point controlled by 2 way and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed.Note-I- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-II- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -III - cost of Eye/bottle thimbles used for connection for 2 way switch is deemed to be included in the unit rate quoted for this item. Note:-III- Rate of cutting chasing included in the unit rate quoted for this item
All as per Sl item No 2.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
All as per Sl item No 2.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
All as per item No.2.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copper earth wire for switch socket combination 3 pin 15 amps on independent board.
M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in existing conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer iin-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item.
All as per Sl item No 7.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
All as per Sl item No 7.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
All as per item No 7.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copper earth wire for switch socket combination 3 pin 15 amps on independent board.
Supply and fix in replacement of Modular switch 1 way, 6 Amps, 1 module complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of Modular switch 1 way, 16 Amps, 1 module complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of Modular switch 2 way, 6 Amps, 1 module complete all as specified and directed.
Supply and fix in replacement of Modular Bell switch 1 way, 6 Amps, 1 module complete all as specified.and directed by Engr-in-charge.
S & F Bell ding dong electronic complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of Modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of Fan regulator modular type 2 module complete all as specified and directed by Engr-in-charge.
Ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed by Engr-in-charge.
Material and labour for in replacement angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 23 watts for batten fitting, including plastic square board of required size, complete all as specified and directed.
S&F 9 watt LED Bulb with base cap B22/E27 type minimum 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500 /3000 K with CRI of LED >90 complete all as specified and directed.
Supply and fix in replacement of New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07, with all accessories including suitable bracket with 32 mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of Recess mounted LED luminaire 36 watt 3600K-6300K suitable for gridd celling cutout dimensions: 2x2 Ft. incl connecting with twin core copper wire from ceiling rose to fitting, Fixture size: (LxWxH) in (595x595x65) mm incl lamp and driver all as specified & directed.
Supply and fix in replacement of Recess mounted LED luminaire 36 watt warm white 3000K suitable for gridd celling cutout dimensions: 2x2 Ft. incl connecting with twin core copper wire from ceiling rose to fitting, Fixture size: (LxWxH) in (595x595x65) mm incl lamp and driver all as specified & directed.
Supply and fixing LED flat panel 2 x 2 ft size fully diffused surface mounted fitting (grid/gypsum type) 36-40 watt, 5700 K warm/cool white with powder coating and CRCA front cover incuding frame with provision of PVC flexible copper conductor cable from ceiling rose to light fittings as in repair complete all as specified and directed by Engr-in-charge.
S&F Ceiling/surface mounted Slim design LED round Downlight with Superior light output and internal driver 9/10 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
S&F Ceiling/surface mounted Slim design LED square Downlight with Superior light output and internal driver 18/20 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
S & F in replacement of new generation energy saving and environmental friendly long life industrial 80 Watt LED High Bay luminaries with clear PC diffuser powder coated Aluminium body IP 65 mounting with eye bolt and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed. Make: crompton/Havells/Philips/bajaj
Supply and fix in replacement of Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed by Engr-in-charge.
M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Supply and fix Modular switch in repair 1 way, 6 Amps, 1 module, 230 volts make and fitment as per gound requirement complete all as specified.NOTE-contractor shall visit the site to check make and size of item.
Supply and fix Modular switch in repair 1 way, 16 Amps, 1 module, 230 volts complete all as specified. NOTE-As per existing fitment contractor shall visit the site to check make and size of item.
Supply and fix Modular socket in repair 5 pin 6 Amps, 2 module 230 volts complete all as specified. NOTE-As per existing fitment contractor shall visit the site to check make and size of item.
Supply and fix Modular socket in repair 5 pin 6 &16 Amps, combination type 2 module complete all as specified. NOTE-As per existing fitment contractor shall visit the site to check make and size of item.
Supply and fix in replacement of metal flush box of 3 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 4 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 6 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 8 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 3 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 4 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 6 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 8 module in MAP qtrs located in NEW cantt complete all as specified and directed.
M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.0 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
M & L for Sub main wiring with two single core 10.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 10.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
M & L for Sub main wiring with 04 (Four) single core 10.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through pvc concealed conduit of suitable dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note1:- 4 Runs of 10.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this item shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of suitable size dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in and making good to facing where required pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth. (iii) Taking down/out existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Supply and fix in replacement of MCCB, 4 Pole, 100 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement epoxy power coated MCCB distribution distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with common bus-bar rated 200 Amp at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth (iii) Connection of cable with VTPN shall be done through appropriate size of thimble.
Supply and fix in replacement of MCB, single pole & neutral (SPN) 10 KA 240 volts, 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
Supply and fix in replacement of Sheet metal enclosure 4 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
Supply and fix in replacement of Sheet metal enclosure 12 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
S & F in replacement of MCB , SPN, 240 Volts ,32-40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge)
S & F in replacement of MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
S & F in replacement of MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge)
S & F in replacement of Sheet metal enclosure DB TPN 4 ways double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link flush mounting type, drilling holes for incoming and out going cables complete with IP-43 protection complete all as specified and directed by Engr-in-charge
M & L for replacement of UNSV Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement @ 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation including charcoal and common salt in alternative layers 15 cm Thick mixed refilling of soil etc complete all as directed by Engineer-in-charge.
S & F in repacement of UNSV RCBO, double pole (DP) 300mA, 240 volts 16 to 32 Amp capacity for earth leakage protection,overload & short circuit protection fixing in DB’s complete all as specified and directed.
S & F in repacement of UNSV RCBO, double pole (DP) 300mA, 240 volts 40 to 63 Amp capacity for earth leakage protection,overload & short circuit protection fixing in DB’s complete all as specified and directed.
S & F in repacement of UNSV RCBO, four pole (FP) 300mA, 240 volts 40 to 63 Amp capacity for earth leakage protection,overload & short circuit protection fixing in DB’s complete all as specified and directed.
Supply and fixing PVC gangbox 15 amp 1 switch and 1 socket 15 amp all as specified
Supply and fixing PVC gangbox 5 amp 2 switch and 2 socket 5 amp all as specified.
Supply and fixing PVC gangbox 5 amp 2 switch and 1 socket 5 amp all as specified.
Supply & fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 18/20W 6500K cool /warm white of capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge.
Supply and fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 10/12W 6500K of capacity ,watt,2 ft long incl 3 core flexible wire 0.5 sqmm copper conductor cable all as specified and directed by Engr-in-charge.
Supply & fix in replacement of existing unserviceable FTL with new techonlgy ultra bright led tubelight cool/warm white with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing t5 tubelight with G 13 lamp holders to give glare free light with separate led driver of capacity 18W 865 1148mm LED including neccessary electric conection with batten .
Supply & fix in replacement of existing unserviceable batten with BOX TYPE Pre-coated CRCA body, heavy duty regaL Batten for LED tube universal batten for G13 T8 lamps including neccesary fitting on wall and making electric connection from ceiling rose to connector with suitable size of electric cable and making good the disturbed surface.
M & L for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 1.5 sq. mm main cable + 1 run of 1.5 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item.
M & L for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 2.5 sq. mm main cable + 1 run of 2.5 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item.
Bakelite sheet cover not less than 3 mm thick for switch boxes of size 100 x 100 mm all as specified & directed.
Bakelite sheet cover not less than 3 mm thick for switch boxes of size 175 x 100 mm all as specified & directed.
Bakelite sheet cover not less than 3 mm thick for switch boxes of size 200x200 mm all as specified & directed.
Bakelite sheet cover not less than 3 mm thick for switch boxes of size 200x250 mm all as specified & directed.
Supply and fix in replacement of LED post top fitting 40 W powder coated aluminium die cast and spun aluminium with clear/diffused PC cover suitable for landscape lighting 240V, 50 Hz ,AC supply complete with all accessories internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of light with degree of protection IP 65,CCT 6500K complete all as specified and directed by Engr-in-charge. Note: Cost of GI pipe of suitable dia of length 4 feet, grouting holes into piller and cement work has been included in the rate quoted by contractor
Supply and fix in replacement of 9/12 watt LED light fitting decorative type wall mounting fixture including LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to conector of the light complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of LED post top fitting 20-25 W powder coated aluminium die cast and spun aluminium with clear/diffused PC cover suitable for landscape lighting 240V, 50 Hz ,AC supply complete with all accessories internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of light with degree of protection IP 65,CCT 6500K complete all as specified and directed by Engr-in-charge. Note: Cost of GI pipe of suitable dia of length 4 feet, grouting holes into piller and cement work has been included in the rate quoted by contractor
Supply and fix in replacement of highly reliable energy efficient multi high power LED with lens flood light designed with optimized optical performance and good heat dissipation with uniform distribution of capacity 100 Watt, CCT 5700-6500K, CRI>70, rated voltage 220V-240V AC, 50 Hz, Power factor>0.9, IP-66 dimension 290x235x155 mm epoxy powder coated pressure die casted aluminium housing with bright anodised aluminium reflectro and enclosed with heat resistant and toughened glass having constant current driver suitable for 140-280V AC working range suitable for facade lighting with all accessories internally pre wired including connecting with flexible copper conductor to connector of the light with necessary fixing arrangements complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge.
Supply and fix new generation, energy saving, environment friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source LED Bollard pathway lights of capacity 10 watt cool/warm white made up of aluminium pipe UV protected pure polyester powder coated having colour temperature(CCT) 3000K warm white fixed to concrete foundation by means of 3 nos M10 bolts complete all as specified and directed by Engr-in-charge. Note:- Cost of PCC foundation of suitable height , PVC conduit 25 mm of suitable length, all electrical connection and all other items whichever required for fixing is deemed to be included in the unit rate quoted for this item.
Supply and fix incl taking down LED garden light fitting cool/warm white with LED bulb upto 20 watt E27/B22 base cap fitted on the piller with the help of GI pipe/PCC up to 550 mm height nut bolts and in stainless steel housing with clear acrylic cover in top section with IP 65 protection class ,connection with 1.5 sqmm 3 core copper cable including making suitable PCC foundation and all electrical connection complete all as directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular stranded conductor size of 6 Sqmm, twin core complete all as specified.
Supply and fix PVC insulated copper conductor 3 core 1.5 sqmm passing through flexible PVC conduit and fixed with clamp complete all as specified and directed. Note:- Rate of Cable and flexible conduit both included in quoted rates.
Taking down and refixing of serviceable tubelight fittings/ceiling lights of any capacity after cleaning complete all as specified and directed by Engr-in-charge.
Fixing only Single phase electric meter 10-40 amp complete all as specified and directed by Engr-in-charge. Note:- Electric meter will be issued under Sch B only
Supply and fix DB box MCB protected socket PVC plastic base having MCB of suitable rating 20 amp C series complete all as specified and directed by engr-in-charge.
AGGARWAL & CO
m/s s.n. builders
gurchan singh & sons.
Arun enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .