Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L1 | Accepted-AOC Accepted due to lowest bidder | |
| 2 | L2₹27.9 L+₹3.3 L (13.2%)Rejected-Finance | L2 | Rejected-Finance Not accepted | |
| 3 | L3₹28.6 L+₹3.9 L (16.0%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L3 | Rejected-Finance Not accepted | |
| 4 | L4₹29.3 L+₹4.6 L (18.9%)Rejected-Finance 01 NEAR GOVERMENT HOSPITAL KOTHI BAZAR ROAD KOTHI SATNA MADHYA PRADESH 485666 | SATNA | MADHYA PRADESH | 485666 | L4 | Rejected-Finance Not accepted | |
| 5 | L5₹31.2 L+₹6.5 L (26.4%)Rejected-Finance BUNGLOW NO 75 CAVALRY ROAD JHANSI CANTT PIN 280001 | JHANSI | JHANSI | UTTAR PRADESH | 280001 | L5 | Rejected-Finance Not accepted |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Nov 2019, 6:00 pmClosed
Shri MK Marothia, IDSE
Garrison Engineer Jhansi
REPAIR MAINT OF VARIOUS CEILING FANS, DESERT COOLERS, GEYSERS, SOLAR WATER HEATER AND OTHER CONNECTED AND MISC WORKS AT AAU AREA JHANSI CANTT AREA UNDER AGE EM AT GE JHANSI
2019_MES_293383_1
GE/JHA/TOK/47 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Jhansi
₹50,000
Yes
8 Jan 2020
28 Oct 2019
27 Nov 2019
28 Oct 2019
25 Nov 2019
11 Nov 2019
Amount
Taking down ceiling fan of any size carefully, sealing cable end, dismantling blades and removing fan and blades to store for servicing including supply, replacing bearings/bushings, capacitor and terminal connector including capacitor holder suitable for any model of existing fan, Painting of ceiling fans complete, with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc and Hanging ceiling fan in its existing or new location and connecting up including provision of cable from ceiling rose or connector to fan and testing for satisfactory functioning complete all as specified and directed by Engineer-in-Charge. Note: Rewinding if required shall be measured and paid separately.
All as per item No. 1.00 here-in-before but of Exhaust fan of any size. Note: Rewinding if required shall be measured and paid separately.
All as per item No. 1.00 here-in-before but of Industrial type Air Circulator Fan of any size. Note: Rewinding if required shall be measured and paid separately.
All as per item No. 1.00 here-in-before but fan of desert cooler of any capacity. Note: Rewinding if required shall be measured and paid separately.
Shifting of ceiling fan 1200mm / 1400mm sweep to workshop, cutting and removing of old burnt/damaged winding, cleaning of slots and other parts and rewinding the ceiling fan motor with super enameled copper winding wire of existing gauge with suitable class of insulation, applying varnish, heating, drying, assembling and testing for satisfactory performance complete all as specified and directed by Engineer-in-Charge. .
All as per item No. 5.00 here-in-before but exhaust fan of size up to 450mm sweep.
All as per item No. 5.00 here-in-before but industrial air circulator fan of size up to 600mm sweep.
All as per item No. 5.00 here-in-before but desert cooler fan of size up to 500mm sweep.
Supply and fix in replacement of customized Fan clamp made out of 3mm thick MS flat bent to required shape as per site requirement fixed with suitable size of number of nuts, bolts & washers etc suitable for fixing down rod including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Fan down rod of suitable size up to one meter long as per site requirement, having suitable holes on top and bottom of rod for inserting bolts and for drawing wires etc complete all as specified and directed by Engineer-in-Charge.
Supply only standard GI fan clamp with rubber bush, bolts, nuts, spring washers & split pins etc complete all as specified and directed by Engineer-in-Charge.
Supply only electronic fan regulator rotary type in 5 steps 100W, 240V, 50Hz complete all as specified and directed.
Supply only PVC insulated and PVC sheathed white coloured twin core flat cable with 0.75 sqmm stranded copper conductor conforming to IS:694.
Supply only PVC insulated and PVC sheathed three core round cable with 1.5 sqmm stranded copper conductor conforming to IS:694.
Supply only PVC insulated and PVC sheathed three core round cable with 2.5 sqmm stranded copper conductor conforming to IS:694.
Supply only of Plug top, 3 pin, 16 Amps, single phase, 230 volts
Supply only of Plug top, 3 pin, 6 Amps, single phase, 230 volts
Taking down desert coolers of any capacity by disconnecting all the electrical connections, removing side panels, cleaning complete and painting the coolers with two coats of synthetic enamel paint out side and moisture resistance primer inside with spray painting and fixing back the removed panels and reconnecting with electrical connections and writing the MES No complete all as specified and directed by Engineer-in-Charge. Note: Rewinding of fan motor and spare parts required shall be measured and paid separately under relevant items.
Supply and fix in replacement of Submersible water pump suitable for desert coolers of any capacity
Supply and fix in replacement of cooling pads (set of 3 Nos) for the evaporative desert coolers of any capacity.
Supply and fix in replacement of PVC hose pipe along with necessary fittings and PVC distributor suitable for existing model of desert coolers of any capacity
Supply and fix in replacement of Rotary/ piano type switch suitable for existing model of desert coolers of any capacity.
Supply and fix in replacement of Fan blade set suitable for existing model of desert coolers of any capacity.
Supply and fix in replacement of Ball brass valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule of size 15mm dia bore suitable for desert coolers.
Taking down carefully the electric storage type water heater of capacity up to 50 ltrs from its installed position by disconnecting all water and electric supply connections for necessary repairs, opening the geyser carefully, identifying and replacing the defective parts, reassembling and reinstalling in its existing location or new location and testing for proper functioning complete all as specified and directed by Engineer-in-Charge. Note: The spare parts required shall be measured and paid separately under relevant items as "Supply Only".
Supply only heating element 1500 Watts / 2000 Watts of any type suitable for existing model of geyser 25L/50L.
Supply only thermostat of any type suitable for existing model of geyser 25L/50L
Supply only apparatus plate of any type suitable for existing model of geyser of capacity 25L/50L.
Supply only indicator lamp Red or Green of any type suitable for existing model of geyser of capacity 25L/50L.
Supply and fix in replacement of flexible PVC connection 450mm long suitable for Hot/Cold water application.
Supply and fix in replacement of 20A rated metal clad plug 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC
Supply and fix in replacement of 20A rated metal clad socket 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC
Supply and fix in replacement of modular socket 6A/16A, 3 pin.
Supply and fix in replacement of modular socket 25A, 3 pin.
Supply and fix in replacement of mini MCB 16A to 25A, SP, C curve suitable for modular switch board.
Supply and fix in replacement of modular white cover plate with frame 4 module.
Supply and fix in replacement of MCB, SP, 6 - 32 A, 10 KA, 'C' curve.
Supply and fix in replacement of MCB, SPN, 40 A, 10 KA, 'C' curve.
M&L for sub main wiring with 2 x 4 sqmm + 1 x 4 sqmm FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including taking down existing sub main wiring of any description complete all as specified and directed by Engineer-in-Charge. Notes:- (i) Three runs of 4 sqmm copper cable and one run of PVC conduit shall be measured as one unit length. (ii) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (iii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables to avoid any damage to the structure. (iv) No cutting shall be done on ceiling for laying PVC conduit. Surface conduit or PVC casing capping may be used in that portion. (v) Quantum of work at each particular location shall be as directed by Engineer-in-Charge. Contractor shall not have any claim on quantum of work at each particular location and the quoted rate shall deemed to be inclusive of this provision.
Supply and fix in replacement of heating element suitable for Solar Water Heater of capacity up to 200 Ltrs.
Supply and fix in replacement of thermostat suitable for Solar Water Heater of capacity up to 200 Ltrs.
Shifting from one location and Installation at new location, testing and commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 200 LPD complete with Flat Plate Collector, Hot Water Storage tank etc including necessary cleaning complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Triple-layer white colour Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 Ltrs hoisted and fixed in position all as specified in SSR Part I
Supply and fix in replacement of Tubes, 'medium grade' galvanized, with all fittings of size 25mm NB and fixed complete to walls and ceilings or laid in floors / trenches etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Tubes, 'medium grade' galvanized, with all fittings of size 20mm NB and fixed complete to walls and ceilings or laid in floors / trenches etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Tubes, 'medium grade' galvanized, with all fittings of size 15mm NB and fixed complete to walls and ceilings or laid in floors / trenches etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Hot water pipe duly insulated with glass wool and aluminium cladding of 15 mm bore medium grade GI pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Hot water pipe duly insulated with glass wool and aluminium cladding of 20 mm bore medium grade GI pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of CP Bib taps 15mm NB, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
Supply and fix in replacement of forged brass ball valve of size 25mm NB with screwed female ends complete all as directed.
Supply and fix in replacement of forged brass ball valve of size 20mm NB with screwed female ends complete all as directed.
Supply and fix in replacement of forged brass ball valve of size 15mm NB with screwed female ends complete all as directed.
Cutting existing 25mm dia (bore) steel tubing in position and screwing both ends for provision and insertion of 25mm x 25mm x 25mm dia (bore) GI Tee along with necessary GI unions and nipples as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 Type B1 using 20mm graded stone aggregate as in coping including necessary form work and rendering with CM 1:4 complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of LED flood light fitting 30 Watts in Aluminium die-cast housing and toughened glass with silicon gasket for IP66 protection including taking down existing unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED flood light fitting 50 Watts in Aluminium die-cast housing and toughened glass with silicon gasket for IP66 protection including taking down existing unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED flood light fitting 100 Watts in Aluminium die-cast housing and toughened glass with silicon gasket for IP66 protection including taking down existing unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge.
Supply only switch piano flush type 6 Amps, one way, 240V, 50Hz
Supply only fan capacitor 2.5 mfd, 400/440V, 50 Hz AC.
Supply only fan capacitor 4 mfd, 400/440V, 50 Hz AC.
Supply only fan capacitor 8 mfd, 400/440V, 50 Hz AC.
Supply only LED tube rod 20 watt, retrofit type, 4 feet with PC body, full white.
JAI BALAJI CONSTRUCTIONS
M/S SHIVA TRADERS
ADARSH ENTERPRISES
m/s ramesh saran agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .