Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹11,335
Closing Date
3 Jun 2025, 11:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Transmission Corporation Limited
RAJU H G
Providing 02 Nos of additional 11kV MCVCB for load bifurcation of overloaded feeders in 66/11kV B. G. Nagara S/s in Nagamangala Taluk Mandya District on PTK basis (Reserved for CAT-II(A))
KPTCL/2025-26/SS/WORK_INDENT2186/CALL-2
KPTCL/2025-26/SS/WORK_INDENT2186/CALL-2
Reserved
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Mysuru
18 documents required · 15 mandatory · 3 optional
Past Experience Documents (if any) such as LOI or LOA, DWA, Work Done Certificate, Performance Certificates from KPTCL and Non-KPTCL in last 05 years as per KW-1 (not compulsory)
valid Super grade Electrical Contractor License issued by the Government of Karnataka as on the date of opening of techno-commercial bid (refer 2.3 of ITT)
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five years as per 3.10(iv) of ITT.
3.6: Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:Assessed Available Tender Capacity: (AxNx1.5-B)Where A-Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years (updated to FY 2024-2025) taking into account the completed as well as works in progress.
3.7: Even though the Tenderers meet the above criteria, they are subject to be disqualified if they have:- Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements and/or- Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc. and/or- Participated in the previous Tender for the same work and had quoted unreasonably high Tender prices and could not furnish rational justification.
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded as per 3.10(xv) of ITT.
Minimum Average Annual Turnover (MAAT) of the bidder for best two years out of last preceding five financial years ending on March or December as the case may be, shall not be less than Amount put to Tender (ABT) as per 3.2(a) of std tender documents(ITT).
as per 3.10(iv) of ITT
Bidder shall ensure that soft copies of No Deviation CERTIFICATE, Letter of Undertaking, as revised in Annexure , Any other undertaking / agreement (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysore, after the last submission date and on or before the date & time of opening of techno commercial bids.
The bidder should furnish the works on hand details as per 3.10(v) of ITT.
Bidder shall ensure that soft copies of i. Letter of undertaking for Non performance ii. Letter of undertaking for Risk and Cost iii. Letter of undertaking for Litigation iv. Letter of undertaking to source the supply of equipment material from KPTCL approved Vendors only (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids as per 3.10(xviii) of ITT
i. Letter of undertaking to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India (Annexure-XVI) ii. Letter of undertaking as per clause No.1.5 of Annexure-XVII iii. Letter of undertaking as per clause No.1.6 of Annexure-XVII (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids.
Valid ESI certificate
Valid EPF Certificate
Bidder shall upload selfdeclaration stating that no such actions against the bidder haven been taken by KPTCL in the last 6 months as on date of bid submission invoking Risk & cost, failing which the offer is liable to be rejected (refer clause 3.10(ii) of ITT.
Any other required documents as per the terms and conditions of the tender.
Shall be uploaded besides submitting the ATTESTED xerox copies of same to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids.
Valid Caste Certificate in support of reserved tender participation
Valid Karnataka Residential Certificate
₹500
₹11,335
20 May 2025
20 May 2025
5 Jun 2025
31 May 2025
29 May 2025
Providing 02 Nos of additional 11kV MCVCB for load bifurcation of overloaded feeders in 66/11kV B. G. Nagara S/s in Nagamangala Taluk Mandya District on PTK basis
11KV UG cable 3Cx240Sq mm
11 KV Heat shrinkable cable termination kit for XLPE Cable 3Cx240Sq mm
Copper control cable
a) 19Cx 2.5 Sqmm copper control cable (for Annunciation and Remote desk)
d) 2 core 6 Sq mm (for DC supply)
c) 2 core 2.5 Sq mm ( for AC supply)
RCC Pole - 9 Mtr Long, 145 Kg WL as per IS-785 (For DP set)
DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL - GI
H frame set for GOS mounting GI
Earth Bond 450mm long
11KV GOS S/B 400Amps
Pad clamps suitable for Coyote/Rabit Conductor
PG Clamps for Coyote Conductor
Coyote ACSR Conductor
LA's 9KV,10KA class for DP structure station type( metaloxide type)
Aluminium lugs 240 Sq mm ( Connects b/w pothead & Conductor)
11kV Epoxy Busbar insulators with nut & bolts suitable(10mm) for LA GI Flat supporting
A) Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75 Mtrs long with 2 part clamp out of G.I.Flat 50X6mm continuously welded around the pipe using cast iron ...
D) Earthing name plates for new earting pits
Galvanised Bolts & Nuts
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%,...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Terminal Blocks (knife type)
(8 TB's per Feeder) = (8x2 nos = 16)
Current Cable - 2.5 Sq-mm multistrand copper wire for CT termination
(Each color 15mtrs-R-Y-B) (15mts x 3 x 2 feeder = 90mtr)
Voltage Cable - 2.5 Sq-mm multistrand copper wire for PT termination
(Each color 5mtrs-R-Y-B-N) (5mts x 4 x 2 feeder = 40mtr)
Control Cable - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU) (15mtrs x 2 feeder = 30mtrs)
Signal Cable - 10 Copper core x 0.5sqmm
Feeder to Feeder loop = 5mts x 2feeder =10mtrs) Remote control desk to RTU (for DI):15mtrs x 2 feeder. = 30mtrs
1.5 Sqmm Grey wire for interfacing of DI and DO (20 mtrs for each panel)(20x2=40mtr)
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the size 2.5 sqmm (80 lugs/panel x 2 = 160)
C-type channel of size 50x100x50x6mm (50cm/panel) = (0.5m x 2 nos = 1 Mtrs)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (Size: 32mm dia)
CT TB's - 6 nos for each panel (1 x 6 = 6 nos)
11KV, MCVCB, 500MVA, 25KA, 1250A Incomer 800A feeder:(a) Feeder panel (With CTs of 400-200/1-1A)including connecting plates
11KV UG cable 3Cx240Sq mm
a) 11 KV Heat shrinkable cable termination kit for XLPE Cable
3Cx240Sq mm (2 No Outdoor + 2No Indoor)
Annuncition & remote control panel for Four feeder
Copper control cable
a) 19Cx 2.5 Sqmm copper control cable (for Annunciation and Remote desk)
d) 2 core 6 Sq mm (for DC supply)
c) 2 core 2.5 Sq mm ( for AC supply)
DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL - GI
Pole concreting
H frame set for GOS mounting GI
11KV GOS S/B 400Amps
Coyote ACSR Conductor
LA's 9KV,10KA class for DP structure station type( metaloxide type)
A) Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75 Mtrs long with 2 part clamp out of G.I.Flat 50X6mm continuously welded around the pipe using cast iron ...
B)Supplying & Providing 450 mm dia 450 mm height 1.5" to 2" thick hume pipe collar (non pressure type) for earth pits including all lead and lifts etc.,
C) Grounding of equipment with 50x6mm G.I. Flat and connecting Equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and con...
D) Earthing name plates for new earting pits
Loading and unloading of poles, switchgear and other materials etc
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%,...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Control Cable-10 Copper core x 1.5sqmm (From remote contol desk to RTU) (15mtrsx2 feeders=30mtrs)
Signal Cable - 10 Copper core x 0.5sqmm
Feeder to Feeder loop = 5mts x 2feeder =10mtrs) Remote control desk to RTU (for DI):15mtrs x 2 feeder. = 30mtrs
1.5 Sqmm Grey wire for interfacing of DI and DO (20 mtrs for each panel)(20x2=40mtr)
CT TB's - 6 nos for each panel (1 x 6 = 6 nos)
Miscellaneous items like, Ferrules, cable ties, insulation tape, & Labour for cutting, weldind, drilling, etc
Configuration of RTU and Engineering along with validation of data at SLDC
11KV Switchgear, MCVCB, 500MVA, 25KA, 1250A Incomer 800A feeder
a) Feeder panel (With CTs of 200-100/1-1A) b) Adapter Panel 1250A (for Megawin to MEI) Annunciation & Remote control panel (1IC+4F)
b) For additional 11kV panel
Wiring & Assisting in Testing and Commissioning
11 kV MCVCB Switchgear
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cm in depth, compacting each deposited layer by ramming after watering with a lead upto 50m , and lift upto 1.5m....
Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete....
Providing and laying of bricks for UG cables
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BG nagara mcvcb BOM.pdf
Others - Bill of Materials • 0.11 MB
Volume II A and B.zip
Technical Information / Worksheet • 19.98 MB
Work on Hand details format (Tender).doc
Others - Works on Hand • 0.06 MB
9b. Tender documents - BG Nagara MCVCB.docx
Tender Document • 0.38 MB
NIT BG nagara mcvcb.pdf
Others - NIT • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .