Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.8 CrAccepted-AOC | ₹3.8 Cr | L-1 | Accepted-AOC Lowest |
| 2 | L2₹3.9 Cr+₹16.8 L (4.49%)Rejected-Finance | ₹3.9 Cr+₹16.8 L (4.49%) | L2 | Rejected-Finance L2 |
| 3 | L 3₹4.0 Cr+₹28.5 L (7.60%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹4.0 Cr+₹28.5 L (7.60%) | L 3 | Rejected-Finance L3 |
| 4 | L-4₹4.3 Cr+₹54.3 L (14.5%)Rejected-Finance CANADA BUILDING 224 DR D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹4.3 Cr+₹54.3 L (14.5%) | L-4 | Rejected-Finance L4 |
| 5 | Rejected-Technical 135 D POCKET B MAYUR VIHAR PH 2 DELHI 110 091 | EAST | DELHI | 110091 | - | - | Rejected-Technical Not Eligible for openning of price bid |
Tender Value
₹4.4 Cr
EMD Value
₹8.8 L
Closing Date
18 Oct 2019, 6:00 pmClosed
SM (E-E)
JPNI Airport, Patna
Provision of Ground Lighting Facilities at DEOGHAR Airport Jharkhand
2019_AAI_32924_1
AAI/ER/PAT/SM(E-E)/GLF-Deo
Open Tender
Electrical Works
Works
120 days
Deoghar
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,180
AAI
₹8.8 L
1 Apr 2021
5 Oct 2019
24 Oct 2019
5 Oct 2019
18 Oct 2019
5 Oct 2019
5 Oct 2019 - 16 Oct 2019
Amount
Supply of elevated type bi-directional high intensity runway edge light fixture complete with breakable coupling, mounting assembly, optical assembly, base plate , gasket, bipin lamp holder, connecting lead i/c supply of 150W/6.6A halogen lamp, SS bolts & washers, etc. as required and as per enclosed specifications with following lenses/filters. (i) With Clear/Clear Lens
Supply of elevated type bi-directional high intensity runway edge light fixture complete with breakable coupling, mounting assembly, optical assembly, base plate , gasket, bipin lamp holder, connecting lead i/c supply of 150W/6.6A halogen lamp, SS bolts & washers, etc. as required and as per enclosed specifications with following lenses/filters. (ii) With Clear/Yellow Lens
Supply of elevated type bi-directional high intensity runway edge light fixture complete with breakable coupling, mounting assembly, optical assembly, base plate , gasket, bipin lamp holder, connecting lead i/c supply of 150W/6.6A halogen lamp, SS bolts & washers, etc. as required and as per enclosed specifications with following lenses/filters. (iii) With Red/Green
Supply of 180 degree following fliters for Runway fitting etc. to complete as required. (i) Yellow filters
Supply of 180 degree following fliters for Runway fitting etc. to complete as required. (ii) Red filters
Supply of 180 degree following fliters for Runway fitting etc. to complete as required. (iii) Green filters
Supply of elevated type uni-directional high intensity Approach light fixture complete with breakable coupling mounting assembly, base plate, gaskets, bi-pin prefocus lamp holder, refractor assembly with adjustment mechanism, lens/spreader glass, standard secondary lead i/c supply of 150W/6.6A halogen lamps, SS bolts & washers etc. complete fitting confirming to latest ICAO requirements and specifications.
Supply of elevated type LED Taxiway Edge light fitting (MIRL fitting) for use as Taxiway / Apron Edge /Turning Pad lights suitable for operation at 2.8 Amps to 6.6 Amps series circuit supply current complete with suitable LEDs, Omni-directional Blue lens (glass), Lens clamping mechanism, breakable coupling, rings /gaskets, base plate with 06 nos. M-10 stainless steel bolts and including an integrated encapsulated suitable electronic converter with standard secondary lead etc. complete fitting confirming to latest ICAO standards /requirement as required.
Supply of following Inset type light fixture made of die cast aluminium alloy shallow base and matching top fixture assembly with heat resistant accessories, prism assembly, optical assembly, "O" ring seal, pressure relief test plug, lenses, connecting lead i/c supply of lamp(s), all required hardware etc. as required for ready to site installation fixture and confirming to tenders technical specifications, terms & conditions etc. complete as required. (i) 2x105w Bi-directional Runway Edge light (Clear/Yellow )
Supply of following Inset type light fixture made of die cast aluminium alloy shallow base and matching top fixture assembly with heat resistant accessories, prism assembly, optical assembly, "O" ring seal, pressure relief test plug, lenses, connecting lead i/c supply of lamp(s), all required hardware etc. as required for ready to site installation fixture and confirming to tenders technical specifications, terms & conditions etc. complete as required. (ii) 2x105w Bi-directional Runway Edge light (Clear/Clear )
Supply of 3 lamps PAPI unit set with breakable couplings, legs, connecting secondary leads, base plates, all required hardware complete i/c supply of lamps and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply tool kit set for PAPI calibration with clinometer, calibration checking stickt set with base plate(s) & all required hardware complete and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply of following rating 5000V, 50 Hz individual lamp series type Isolating Transformer encapsulated in TPR/TPE with primary and secondary connection leads complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. (i) 15 Watt,6.6A/6.6A(for Taxiway 135 Nos LED edge light fixtures)
Supply of following rating 5000V, 50 Hz individual lamp series type Isolating Transformer encapsulated in TPR/TPE with primary and secondary connection leads complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. (ii) 15 Watt,20A/6.6A(for T/Pad 24 Nos LED edge light fixtures)
Supply of following rating 5000V, 50 Hz individual lamp series type Isolating Transformer encapsulated in TPR/TPE with primary and secondary connection leads complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. (iii) 150 Watt, 20A/6.6A[ (for R/W edge light, R/W end cum thresold lights)(84+73+24) & for Approach09 light fixtures (120)]
Supply of following rating 5000V, 50 Hz individual lamp series type Isolating Transformer encapsulated in TPR/TPE with primary and secondary connection leads complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. (iv) 150 Watt, 6.6A/6.6A[ (for Approach 27 light fixtures ( 17)]
Supply of following rating 5000V, 50 Hz individual lamp series type Isolating Transformer encapsulated in TPR/TPE with primary and secondary connection leads complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. (v) 200 Watt, 20A/6.6A(for inset type R/W edge light fixtures 10 nos & 15 nos for signage)
Supply of following rating 5000V, 50 Hz individual lamp series type Isolating Transformer encapsulated in TPR/TPE with primary and secondary connection leads complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. (vi)200 Watt, 6.6A/6.6A(for PAPI light fixtures)(08 fittings x 03 nos+ for 06 nos for signage )
Supply of 1C x 16 sq. mm sizes 5 kV grade PVC insulated & PVC sheathed, antitermite & anti-rodent, multi-stranded copper conductor single core Airfield lighting cable confirming to IS 1554 (Part-II) with up to date amendments and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply of 1C x 6 sq. mm sizes 5 kV grade PVC insulated & PVC sheathed, antitermite & anti-rodent, multi-stranded copper conductor single core Airfield lighting cable confirming to IS 1554 (Part-II) with up to date amendments and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply of 2C x 6 sq. mm sizes 5 kV grade PVC insulated & PVC sheathed, antitermite & anti-rodent, multi-stranded copper conductor single core Airfield lighting cable confirming to IS 1554 (Part-II) with up to date amendments and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply of 2C x 4 sq. mm secondary lead made out of multi-stranded annealed copper conductor suitable for airfield lighting system confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply of 5 kV grade ESNA connector and suitable for field attachment with 5kV grade PVC insulated, PVC sheathed following cable conforming to technical specifications etc. complete as required. (i) single core 16 sq. mm copper conductor
Supply of 5 kV grade ESNA connector and suitable for field attachment with 5kV grade PVC insulated, PVC sheathed following cable conforming to technical specifications etc. complete as required. (ii) single core 6 sq. mm copper conductor
Supply of 2C x 2.5 sq. mm & 2.5 meter long copper conductor two pin secondary leads suitable for airfield lighting system and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply of 2C x 2.5 sq. mm & 0.3 meter long copper conductor two pin secondary leads suitable for airfield lighting system and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply of C.I isolating transformer housing box, water tight round type, metal container of outside size 330 mm height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having a clear hole at two side surface centre 75 mm above bottom surface suitable to receive of 50 mm dia (outer dia) HDPE/G. I. pipe and including check nuts as required and another hole at 175 mm from the bottom of the CI box to receive one no. 15 mm dia, "B" class, GI pipe and check nut as required. The box should have two SS earth bolts of M10 x 30 mm tapped inside near the hole away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm dia, "B" class GI pipe and having clear opening of 220 mm at the top surface and 6 nos. M10 tapped hole at the hole centre 260 mm to receive fitting base plate and bolts and confirming to tenders technical specifications, terms & conditions etc. complete as required. (i) Double Hole Type ( Holes opposite to each other )
Supply of C.I isolating transformer housing box, water tight round type, metal container of outside size 330 mm height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having a clear hole at two side surface centre 75 mm above bottom surface suitable to receive of 50 mm dia (outer dia) HDPE/G. I. pipe and including check nuts as required and another hole at 175 mm from the bottom of the CI box to receive one no. 15 mm dia, "B" class, GI pipe and check nut as required. The box should have two SS earth bolts of M10 x 30 mm tapped inside near the hole away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm dia, "B" class GI pipe and having clear opening of 220 mm at the top surface and 6 nos. M10 tapped hole at the hole centre 260 mm to receive fitting base plate and bolts and confirming to tenders technical specifications, terms & conditions etc. complete as required. (ii) Four Hole Type ( Holes opposite to each other )
Supply of C.I isolating transformer housing box, water tight round type, metal container of outside size 330 mm height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having a clear hole at two side surface centre 75 mm above bottom surface suitable to receive of 50 mm dia (outer dia) HDPE/G. I. pipe and including check nuts as required and another hole at 175 mm from the bottom of the CI box to receive one no. 15 mm dia, "B" class, GI pipe and check nut as required. The box should have two SS earth bolts of M10 x 30 mm tapped inside near the hole away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm dia, "B" class GI pipe and having clear opening of 220 mm at the top surface and 6 nos. M10 tapped hole at the hole centre 260 mm to receive fitting base plate and bolts and confirming to tenders technical specifications, terms & conditions etc. complete as required. (iii) Three Hole Type
Supply of 1.5 sq. mm copper conductor, multi core, extruded PVC inner sheath insulated, PVC sheathed, armoured control cable of 1.1 kV grade confirming to IS 1554 (part-I) with up to date amendments and confirming to tenders technical specifications, terms & conditions etc. complete as required with no. of cores as mentioned below: (i) 10 core control cable
Supply of single mode, 6 core armoured OFC cable.
Supply, Installation, Testing and Commissioning of high intensity Airport rotating beacon similar to type L-802A suitable for operation on 220/240V, 50 Hz, single phase AC supply, FAA certified i/c supply of suitable wattage lamp(s), ON/OFF control panel, extension ON/OFF of beacon from control desk of ATC tower, all required switches, contactors, cabling, connection/inter-connections etc. including testing & commissioning of the beacon and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply of spare lamp suitable for the mentioned beacon as above with connector complete as required.
Design, Supply, Installation, Testing and Commissioning of FAA compliant, indoor type Microprocessor based Constant Current regulator (CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415V, 50 Hz., AC supply, provision for control supply with all switchgears, CCR protections, connection/inter-connections etc. and confirming to tenders technical specifications, terms & conditions etc. complete as required. Note: CCRs should be compatible with ALCMS system. (i) 30 Kw, 20A output current.
Design, Supply, Installation, Testing and Commissioning of FAA compliant, indoor type Microprocessor based Constant Current regulator (CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415V, 50 Hz., AC supply, provision for control supply with all switchgears, CCR protections, connection/inter-connections etc. and confirming to tenders technical specifications, terms & conditions etc. complete as required. Note: CCRs should be compatible with ALCMS system. (ii) 7.5 Kw, 6.6A output current.
Design, Supply, Installation, Testing and Commissioning of FAA compliant, indoor type Microprocessor based Constant Current regulator (CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415V, 50 Hz., AC supply, provision for control supply with all switchgears, CCR protections, connection/inter-connections etc. and confirming to tenders technical specifications, terms & conditions etc. complete as required. Note: CCRs should be compatible with ALCMS system. (iii) 4 Kw, 6.6A output current.
Supply installation testing and commissiong of frangiable & illuminated wind direction indicator(WDI) confiriming to ICAO Annex 14, Volume I and suitable for operation on 230V, 50Hz, single phase,AC Supply and consist of following complete as required. (a) Minimum 4.5 mtr height Fibre-reinforced plastic(FRP) frangible lattice mast(minimum size 500mmx500mm).The frangibility shall confirm to ICAO Annex 14 & Aerodrome design manual part-6 / FAA. The color of mast shall be preferably aviation Red & White. (b) Wind sock assembly complete with slip rings, Pole, Aluminium drum, bracket for drum, bearing with rain shade, carbon brush with holder bracket and wind sock cloth of color Red & White etc. (c )Mounting arrangement & provision of sufficient LED lights fixtures to meet minimum lux level requirement as per technical specification and ICAO Standard. (d) One no. LED Aviation obstruction light having aluminium cast body and red polycarbonate dome. (e ) CI/MS outdoor Junction box with 6A DP MCB, interconnection internal wiring for lights using PVC insulated copper cond cable in suitable PVC rigid/DWC/HDPE Pipe. (f)Hinged arrangement for tilting down of mast for maintenance. (g)Providing and laying suitable cement concrete foundation with supply of grouting accessories i.e anchor bolts,frame etc for installation of WDI as per OEM recommendations.
Supply, Installation, Testing, Commissioning of Landing 'H' direction indicator complying ICAO standard consisting of three rectangular AL limbs having length of 4000 mm each supported with 50 mm dia Aluminium frangible pipe of 1350 mm length & flanges, suitable wattage linear LED lights with driver (minimum IP65) for each limb, each circuits to operate on 230 V, 50 Hz AC supply providing control unit with suitable control transformer, Relay, Contactor, copper wiring upto JB etc. as required for remote operation of landing 'T' from CCR hall as well as from control tower, connections/interconnections, civil foundations for each legs with MS anchor base plate, casting pedestal up to 1 mtr all around the landing 'H' with 1:2:4 cement concrete of 100 mm thick and neat finish top, painting/powder coating, all required materials & SS hardware etc. as required and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Supply, Installation, Testing, Commissioning of Guidance signage board (IP 65 protection) complying ICAO standard of various sizes fabricated from anodized aluminium profile structure & 2mm thick aluminium sheet, 4mm thick long life imported non-specular surface polycarbonate signage sheet, symbols of sign shall be made of self-adhesive 3M film applied on face of polycarbonate sheet and All reflector sheet for light reflection if required. Board shall be illuminated with linear LED's & driver(s) i/c all other accessories, suitable converter to operate on 2.8 Amp to 6.6 Amp AC constant current as incoming supply, mounting legs with breakable coupling & base frame, crimpling & molding secondary leads with connector kit of OEM approved, supply & laying of PVC coated GI flexible pipe with couplers for protecting secondary leads, providing cement concrete foundation of suitable size & depth for each unit, providing pedestal up to 1.5 mtr all around the signage with 1:2:4 CC of 150 mm thick & finish with neat cement plaster, connections/interconnections with isolating transformers complete as required and confirming to tenders technical specifications, terms & conditions etc. complete as required. NOTE:- Supply of Isolating transformers, ESNA connections, secondary cables & transformer housing boxes are not covered in this item, the same shall be measured and paid under separate items.
Supply of all the equipment required to provide Airfield Lighting Control and Monitoring System (ALCMS), type L 890'BB"to the requirements of FAA Advisory Circular No. AC 50/5345-56B (current edition) and additional circular/ mechanisms/ interfaces for power supply equipment, and Landing - H etc., including all hardware and software, licenses & other items as required for successful operation of the system in line with the scope of work, details of equipment, equipment specification, performance criteria etc. Two Vault processor will be provided both running in parallel for redundancy in operation. (Does not include the cost of communication cable between ATC & CCR Room) Event logging & fault annunciation of all CCRs shall be provided.
Supply of HDPE pipe of PN 6 and PE 63 of following size ISI marked, HDPE pipe along with all accessories like socket, bend, couplers etc., conforming to IS 14930, Part II with up to date amendments complete as required in the existing trench in ground 40 mm dia
Supply and laying of 150mm dia 'B' class GI pipe in the soil upto a depth of 30 cm including back filling & making good the surface as per site requirement complete as required.
Supply, installation, testing & commissioning of dust, damp and vermin proof free standing, floor mounted indoor type factory built extendable cubicle type LT panel board (having minimum IP-42 protection) suitable for operation on 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design form CRCA sheet steel of 2 mm thick for frame work & covers, cleaning & finishing complete with 7 tank process for powder coating in approved shade, extensible type TPN aluminium alloy busbars of high conductivity, SMC busbar supports with short circuit withstand capacity of 35 kA for 1 sec, bottom base channel for MS section not less than 100mm x 50mm x 5mm thick, Panel fabrication in transportable sections, entire panel shall have a common copper earth switchgears with required size of aluminium busbar/copper conductor leads & control wiring with 2.5 sq. mm FRLS insulated copper conductor single core cable, cable alleys, 3mm thick for gland plates in two half, i/c all accessories complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. with the following switchgears: A. Incoming Feeders :- 2 no of 250 Amps, 415 V, 35 kA, 4P MCCB, Thermal magnetic release with OL, EF & SC protections (i) LED type indicating Lamp for - R,Y,B and ON with control MCB - 2 Sets. (ii) digital type 3 phase Multi-function Meter with 3 Nos. of single core epoxy resin cast type CTs of 250/5 Amps, 15 VA, CL 1.0 ratings & control MCB - 2 Set. B. Busbar :- 400 Amps, 415 V, TPN Aluminium Busbars with Heat shrinkable colour coded insulation sleeves. C. Buscoupler :- 1 no. of 250 Amps, 415 V, 4P MCCB without protection release. LED type indicating Lamps for ON & OFF with control MCB:- 1 Set D. Mechanical (castle key) interlocking between two incomers and bus coupler so that any two can be ON at one time.- 1 set E. Outgoings:- (a) 06 nos. of 100 Amps, 415 V, 35 kA, 4 Pole MCCB Thermal magnetic based releases having O/L, S/C & E/F protection with ON-OFF indication lamp protected by suitable rating MCBs. (b) 14 nos. of 63 Amps, 415 V, 25 kA, 4 Pole MCCB Thermal magnetic based release having O/L, S/C & E/F protection with ON-OFF indication lamp protected by suitable rating MCBs.
Design, manufacturing, supply, installation, testing and commissioning of weather and vermin proof, powder coated, outdoor ( double door , back side door openable) type feeder pillar, Duly fabricated with 2mm thick CRCA Sheet Steel, 3mm thick sheet steel for glad plat Degree of Protection of Enclossure shall be IP~54.suitable for operation on 3 phase and neutral, 415 V,50 HZ AC system.Entire panel shall have a common GI earth bar of size 50mmx5mm at the rear with two number earth stud. Cable entry will be from bottom. Control Wiring should be done by 1100V grade PVC insulated 2.5 Sq.mm solid copper conductor cable. The feeder pillar shall consist of following swich gears, BUS Bars and other acessories complete as required and as per technical specification attached with tender document. (Feeder piler shall have 03 nos spare cabinet to accomodate 63 Amp MCBs.) a) Incomers :- i) 100 Amps, 415 V, 35 kA, 4 Pole MCCB Thermal magnetic based releases having O/L, S/C & E/F protection with ON-OFF indication lamp protected by suitable rating MCBs with CT operated digital multi function metre – 2 nos.(Incomers) ii) Extended operating mechanism for MCCB- 02 Nos. iii) ON / OFF / Trip (R,G,A) 230 V AC Supply LED indication lamps : 06 Nos. iv) Phase indication lamp LED type (R,Y,B) 230 V AC Supply : 06 Nos. b) Bus coupler : 100 Amps, 415 V, 35 kA, 4 Pole MCCB Thermal magnetic based releases having O/L, S/C & E/F protection – 1 no. c) 100 Amps. TPN Aluminium Busbar d) Outgoings. iii) 63Amp C-Curve TPN MCB : 04 Nos. v) L/R SWITCH : 4Nos. vi) ON OFF LED Indication lamp : 08 Nos.
Installation of elevated light fixture on existing transformer housing box with all required accessories & isolating transformer i/c alignment, levelling, setting of fixture, connection/inter-connection with isolating transformer & fixture as per site i/c testing & commissioning complete as per required and confirming to tenders technical specifications, terms & conditions etc. complete as required.
Installation, Testing and Commissioning of inset type high intensity light fitting by cutting the PCC manually or with the core cutting machine for 12" shallow base and fixing with suitable compound with side cable entry and all assemblies of the fitting in order as per ICAO norms including making necessary conections with secondary lead, plug and sockets and sealing with rubber/ PVC tape etc. complete as required.
Providing, laying and fixing 40 mm dia "B" class G.I. pipe with G.I. fittings including alignment of GI pipe with the existing Housing box and fitting, after cutting the Runway/Taxiway/Appron upto 300 mm depth and minimum width suitable for laying pipe of size upto 50mm dia with the help of suitable cutting machine and mechanical means and disposal of debris upto 300 mtr and also making good the surface after pipe is laid, by providing and laying in position concrete 1:1.5:3 (1 cement : 1.5coarse sand : 3 graded stone aggregate 20 mm nominal size) etc. for concrete surface and ready mix bitumen/ road bond for bituminous surface etc. complete as required.
Installation Testing Commissionig of PAPI unit with base plates & positioning of checking sticks (as mentioned in item no. 6), supply of all required materials, providing civil foundations for pedestal, PCC pedestal up to 1m all around the complete PAPI installation with 1:2:4 cement concrete of 100mm thick, supply, crimping & molding of secondary leads, connections/inter-connections with isolating transformers complete as required as per site i/c testing, commissioning and confirming to tenders technical specifications, terms & conditions etc. complete as required. Note: Supply of isolating transformers & supply, fixing of ESNA connectors are not covered in this item. The same shall be measured & paid under separate items
Making connections of 5 kV grade, 6 & 16 sq. mm copper conductor AFL cables with ESNA connector i/c crimping & fixing, apllying HT tape complete as required.
Installation of transformer housing boxes with a base concrete of 1:3:6 of size 630 x 630 x 100 mm thick all round concrete of 1:2:4, 150 mm thick, the top sloped with 1:2:4 cement including providing and fixing 250 mm long 15 dia "B" Class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling etc complete as required.
ITC of Airfield Lighting Control and Monitoring System (ALCMS) including proper termination of Power and OFC cables as required.
laying of OFC cable through ISI marked HDPE pipe
Laying of 40mm dia HDPE pipe in the existing trench / masonary duct
Laying of 40mm dia HDPE pipe on surface with proper saddling complete as required.
Earthing with GI earth pipe of 4.5 m long and 40 mm dia, including accessories and providing masonry enclosure with cover plate on the top having locking arrangement and watering pipe, complete with charcoal and salt etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing & fixing 6 SWG GI wire along with cable in soil for loop earthing
Providing & fixing 6 SWG GI wire along with cable in existing 15mm dia GI pipe for loop earthing
Proving and laying 50mm dia 'B' Class G.I Pipe including excavation of hard /soft soil complete with threading and alignment of pipe with trasformer housing box, provide check nuts, plastering, finishing etc. as required (for cables entry to trasformer housing boxes).
Proving and laying 15mm dia 'B' Class G.I Pipe including excavation of hard /soft soil complete with threading and alignment of pipe with trasformer housing box, provide check nuts, plastering, finishing etc. as required (for cables entry to trasformer housing boxes).
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 5 kV grade of upto 16 sq. mm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 5 kV grade upto 16 sq. mm size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 5 kV grade upto 16 sq. mm size in the existing RCC/GI/HUME/METAL pipe etc. as required.
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 5 kV grade upto 16 sq. mm size in the existing masonry open duct as required.
Supply of following sizes XLPE insulated & PVC sheathed, 1.1 kV grade, aluminium conductor, armoured powder cable confirming to IS: 7098, Part-1/1988 with upto date amendments. (i) 3.5C x 240 sq. mm
Supply of following sizes XLPE insulated & PVC sheathed, 1.1 kV grade, aluminium conductor, armoured powder cable confirming to IS: 7098, Part-1/1988 with upto date amendments. (i) 4C x 50 sq. mm
Supply of following sizes XLPE insulated & PVC sheathed, 1.1 kV grade, aluminium conductor, armoured powder cable confirming to IS: 7098, Part-1/1988 with upto date amendments. (i) 4C x 10 sq. mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (i) Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (i) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size in the existing RCC/GI/HUME/METAL pipe etc. as required. (i) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required as per specifications. (i) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required as per specifications. (ii) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required as per specifications. (iii) Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required. (i) 3.5C x 240 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required. (ii) 4C x 50 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required. (iii) 4C x 10 sq. mm
Constructing brick masonary manhole chamber of min. outside dimension 1.2m x 1.2m x 1.1m with medium class bricks in cement mortar 1:6 (1 cement : 6 coarse sand) R.C.C. top slab of 100mm thick with mix 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone of aggregate 20mm nominal size), foundation concrete 1: 4: 8 mix (1 cement : 4 coarse sand : 8 graded stone of aggregate 40mm nominal size) in side plastering 12 mm thick with cement mortar 1:4 (1 cement : 4 coarse sand). 02 nos. of equal sizes RCC slabs/covers should be provided in a MS angle frame work of size (35m x 35 x 3mm) at the 04 nos. of edges on top and bottom of the slab.
VISHAL INFRASTRUCTURE LTD
Manish Electricals
AMA Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .