Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.0 L+₹48,513 (1.65%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹33.0 L+₹3.5 L (11.9%)Rejected-Finance 22 JANKALYAN SOCIETY NAVJIVAN AJWA ROAD BARODA 390 019 | BARODA | VADODARA | GUJARAT | 390019 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹33.9 L+₹4.5 L (15.1%)Rejected-Finance GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹40.8 L+₹11.3 L (38.5%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
3 May 2021, 6:00 pmClosed
GE NW NOFRA
GE NW NOFRA DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
PROVISION OF TREATMENT OF SEEPAGE AFFECTED CUPBOARDS AND ADDITION ALTERNATION OF GI CI PVC PIPES OF CERTAIN BUILDINGS UNDER AGE B R-II OF GE (NW) NOFRA COLABA MUMBAI
2021_MES_435013_1
8863
Open Tender
Civil Works
Item Rate
240 days
MUMBAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹85,000
Yes
24 Jul 2021
7 Apr 2021
8 May 2021
7 Apr 2021
3 May 2021
21 Apr 2021
7 Apr 2021 - 20 Apr 2021
Amount
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-charge.
Taking down shutters of any description exc 1 sqm and n exc 2 sq.m each, complete all as specified and directed by Engineer-in-charge.
Taking down shutters of any description n.exc 1 sqm each, complete all as specified and directed by Engineer-in-charge.
M&L for 18 mm thick plywood(7 No of ply) grade BWR, type BB fixed as in repairs with screws to timber frame work complete all as specified and directed by Engineer-in-charge.
S&F of 2nd class hard wood (sal) plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engineer-in-charge.
S&F of 18/19 mm thick pre-laminated partical boad interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame work cupboard etc including 6 mm thick teak wood beading all around complete all as specified and directed by Engineer-in-charge.
M&L for 2nd class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails of sectional area exceeding 6 sqcm and not exceeding 13 sqcm complete all as specified and directed by Engineer-in-charge.
S&F of butt hinges 100 mm mild steel hinges medium weight and fixed complete all as specified and directed by Engineer-in-charge.
M&L for MS flat for hold fast conforming to Fe-310-0 or Fe-410-0 complete all as specified and directed by Engineer-in-charge.
S&F 125 mm long hasp and staple safety type aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-charge.
S&F in repairs 20 mm dia harrison rails anodised aluminium alloy incl brackets, stops and rollers etc complete all as specified and directed by Engineer-in-charge.
S&F flat 30 mm wide and 5 mm thick aluminium anodised rail D type 45 cm long between flanges fixed with screws to timber frame complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc & including scaffolding upto top floor of building complete all as specified and directed by Engineer in charge.
M&L for rendering 20mm thick on other then fair face of brick work or concrete in two coats 15mm thick cement mortar 1:4 and 5mm thick each coat mixed with water proofing powder at rate of 3% of cement or as per manufacturers instructions and rendering is to be finished even and smooth (without using extra lime or cement) and at any height including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Water proofing compound shall be measured separetly under respective item. (ii) Quoted Rate shall include the rates for necessary Scaffolding upto 16th floor of building
M&L for rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces, surfaces to be finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra complete all as specified and directed by Engineer-in-Charge.
M&L for Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) and dismantling floor hearth or wall tiling including cement mortar bedding removing serviceble tiles to store and rubbish off the permises complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick(square/Rectanglar) area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floor including 15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer in charge.
M&L for Glazed ceramic tiles coloured of size 300 X 200 X 6 to 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 10mm thick bedding layer in CM 1:4 and dismantling floor hearth or wall tiling including cement mortar bedding removing serviceble tiles to store and rubbish off the permise complete all as specified and directed by Engineer in charge.
M&L for coloured glazed ceramic tiles 450x300x7 mm thick but as on vertical surfaces such as skirting/dado including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer in charge.
Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down and applying two coats of oil emulsion distemper over a coat 1 to 2 mm thick wall care putty and primer including preparation of surfaces complete all as specified and directed by Engineer in charge.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of 1 to 2 mm thick wall care care putty including primer complete all as specified and directed by Engineer in charge.
M&L preparation of old distempered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil Bound distemper on walls etc all as specified.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed by Engineer in charge.
M&L for preparation of old decorated surface of walls including cornices,etc & applying two coat of white wash on walls complete all as specified and directed by Engineer in charge.
M&L for preparation of old decorated surface of ceiling and applying one coat of white wash on ceiling complete all as specified and directed by Engineer in charge.
M&L for preparation of newly wooden surfaes of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer incl preparation of surfaces complete all as specified and directed by Engineer in charge.
M&L for preparation of old painted wooden surfaes of any description over 10cm width or girth and applying one coat of synthetic enamel paint including external window with necessary scafolding for high rise bldgs complete all as specified and directed by Engineer in charge.
M&L for preparation surfaces of new plastered surfaces wall/chajja and applying one coat of acrylic exterior primer and apply two coats acrylic emulsion exterior grade (100%) etc all as spacified & as suggested by the manufacturers at any height including necessary scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
M&L for preparation of old/new surfaces of walls, washing the surface thoroughly, filling the cracks, creaves with crack filling compound as suggested by the manufacturers and applying two coats of Weather Rain coat paint (shade to match the existing paint) & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Supply only Integral water proofing compound as per IS Code-2645 complete all as specified and directed by engineer in charge.
Taking down Cast iron of 100mm bore fixed on wall or floor at any floor/ any height/ any location including all fittings & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 100 mm bore of sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Taking down Cast iron of 75mm bore fixed on wall or floor at any floor/ any height/ any location including all fittings & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 75 mm bore of sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 100mm sand cast CI Branch pieces (Tee), Single (equal), ordinary or inverted (spigot or socket type) or with parallel branches with ovel access door and jointed with neat cement paste to CI pipes fixed to wall & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 75mm sand cast CI Branch pieces (Tee), Single (equal), ordinary or inverted (spigot or socket type) or with parallel branches with ovel access door and jointed with neat cement paste to CI pipes fixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and directed by Engineer in charge.
S&F in repair 100mm CI ‘P’ or ‘S’ Traps jointed with neat cement paste fixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and directed by Engineer in charge.
M&L in repair 75mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) including complete all as specified and directed by Engineer in charge.
S&F in repair stack clamps suitable for securing 100mm dia CI pipe made out of 50mm by 5mm flat iron and 16mm dia round iron stays Including bolts and nuts and securing ends of stays fixed to wall & including scaffolding upto 16th floor of building complete all as specified.
S&F of stack clamps suitable for securing 75mm dia CI pipe made out of 50mm by 5mm flat iron and 16mm dia round iron stays Including bolts and nuts and securing ends of stays fixed to wall & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F in repair cast iron cowl suitable for 75mm dia pipe & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Taking down rain water pipes/PVC pipes/cemented pipe (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc.,& including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 160mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including GI clamps of approved shape and size approved by GE & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 160mm dia PVC (SWR) bends/shoes any radius fixed to pipe & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in wall including GI clamps of approved shape and size approved by GE & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 110mm PVC (SWR) bends any radius fixed to pipe & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 110mm bore PVC (SWR) branch piece, single (T) equal or unequal provided with access door fixed to pipe & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing, & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 25mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Refixing old 25mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing, & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 20mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Refixing old 20mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing, & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F of 15mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Refixing old 15mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F as in repairs vitreous china squatting pan 'Orrisa Pattern' size 580x440mm white with integral foot rest including connecting and necessary provision of lime concret complete all as specified and directed by Engineer in charge.
Demolition of Cement concrete in any description and in any position not other wise specifically provided and removal of debris to out side MD land complete all as specified and directed by Engineer in charge.
M&L for PCC 1:7:12 with brick aggregate as in lean concrete/filling concrete complete & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
M&L for PCC 1:2:4 for filling and mass concrete incl necessary formwork & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
M&L for Chiping off loose / damaged concrete cover of any thickness by chiseling or as directed upto height of 50m from GL , including necessary scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
S&F for welded steel wire fabric weight n.exc 4 Kg/Sqm dia of strand 3mm and aperture (clear) 10cm fixed to brick/ concrete surfaces with spikes cut to lengths, bent to shape required , & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
Removing loose rust by applying one coat Rust removing compound of make Sika ® Rustoff 100 or its equivalent make as approved by GE by brush, cotton waste swab or spray on the effected metal surface. After the minimum 24 hours remove the loose rust particles by brush. Then, apply one coat of SikaCor® Zinc R or its equivalent make by spray machine / brush for corrosion protection as per manufacturer instruction & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge. Note:- (i) After applying of Sika ® Rustoff 100 over effected area, leave it in contact with the surface till the reddish color of the corroded surface change to nearest original black colour. (Consumtion of Sika ® Rustoff 100 is 0.12 to 0.15 Kg/Sqm per coat) (ii) Mixing Ratio of SikaCor® Zinc R : Components A:B proportion of by weight shall be 94:6. (Consumtion of SikaCor® Zinc R is 0.250Kg/Sqm)
M&L for 10mm thick cement plaster on guniting surfaces in CM 1:4 finished even and smooth without using extra cement, & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer-in-Charge.
M&L for roughening surfaces of old concrete floor by picking , sweeping clean and washing down with water to remove dust etc complete all as specified and directed by Engineer in charge.
M&L for guniting with cement - coarse sand mortar 1:3, with and including organic fiber and polymer modified cement mortar , of make as approved by GE , mixed @ 2 litres per 50Kg of cement used and w/c ratio as per manufacturer's recommendation and used as per the manufacturer's instructions using shotcrete pumps and allied equipment, thickness 30mm to 40 mm, for locations having maximum height upto 16th floor of building including scaffolding complete all as specified and directed by Engineer in charge Make : Nitobond SBR (Styrene-Butadiene Rubber) Latex of FOSROC or its equivalent product of Pidilite / Sika / CIBA Geigy as approved by GE, .
I.J Enterprises
Aditya Construction
SN CONSTRUCTION
GANGAJAL
Gaurav Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .