| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.1 L+₹46,301 (2.62%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.4 L+₹4.7 L (26.8%)Rejected-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L3 | Rejected-AOC L3 | |
| 4 | L4₹24.0 L+₹6.3 L (36.0%)Rejected-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L4 | Rejected-AOC L4 | |
| 5 | L5₹25.6 L+₹8.0 L (45.3%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
20 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Hakimpet
Secunderabad
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATIN OF OTM BUILDINGS AT AFS HAKIMPET UNDER GE(AF) HAKIMPET
2024_MES_680811_1
8725/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hakimpet
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Hakimpet
₹58,000
Yes
8 Jan 2025
23 Oct 2024
22 Nov 2024
23 Oct 2024
20 Nov 2024
6 Nov 2024
Amount
Notes:- 1. The contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safely measures are to be adopted by contractor on site. 3. The contractor shall provide and deploy sufficient electrician (as approved by GE / Engineer in charge) shall report at 9:00 hrs to JE E/M / Engineer in Charge to collect the complaints job card in working days and complete the same completed within 24 Hrs. 4. The complaints shall be rectified within 24 Hrs if the complaints is/are not attended / not completed within 24 Hrs (Except repair/replacement of major items) recovery will be done at Rs 500 per complaint per day. 5. For major parts like replacement of MCB, DBs, MCCBs etc should be rectified within 3 working days, if the contractor not rectify within time then recovery will be done at Rs 1000 per complaint per day. 6. After completion of job work complaint, the contractor has to produce job card duly signed by user & JE / Engineer in Charge. 7. If contractor failed to provide their electrician to attend the complains then recovery will be done at Rs 1000 per day. 8. The contractor should procure minimum 50% of the materials for all items as per BOQ (Other than paints) mentioned in this CA, within 20 days after getting sample approval and kept in safe custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of work. If contractor fail to complete the work within contract due to lack of fittings a penalty of 20% shall be applicable on quoted rates by the contractor. 9. In repair works, rate quoted for demolition /dismantling /taking down is deemed to be inclusive of removing the same from site and station. 10. In maintenance works, the contractor should maintain separate registers for repair works. Day to day complaints should be noted in those registers with SI nos of complaints, location qty of work, status of complaints and signature of in charge and stamp of the office. Formal will be given from concern AGE office. The contractor should obtain the signature of in charge on the same day of work. These register to be submitted to JE (E/M) on every weekend without fail. 11. The contracts involving working at elevated locations of buildings, contractor should ensure proper safety arrangements as per norms. Wearing safety belts and helmets are mandatory. A penalty of Rs 1000 per day will be recovered from contractor if safety norms are not followed. 12. After completion of work, no stores/debris/ loose items be kept at work site or dumped inside station . Entire area to be cleared and waste material be taken outside from the station
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface as per site requirement complete all as specified and directed by Engr-in-Charge.
Taking down existing unserviceable MCCB (any type and capacity) and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge.
Taking down existing unserviceable distribution board with MCBs, switch fuse unit, enclosure and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge.
Taking down Existing old unserviceable submain wiring of any description /type size and removal of UNSV material from site and making good the disturbed surface of walls / ceiling so as to match with the existing finishes all as specified and as directed by the Engineer -in- charge .
M&L for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through new MMS PVC conduit/casing capping of suitable size but not less than 20 mm dia on surface of stone/concrete wall /roof etc all as per site requirement including FRLSH,PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet with sink into the wall for mounting including laminated sheet cover 3mm thick laminated hylam sheet fixed with cadmium plated screws/PVC gang box fully enclosed type for mounting switches,sockets,fan regulator, etc including all accessories and making good the disturbed surfaces of walls and paint touch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge. Note: Inspection elbows, inspection Tees, self locking saddle clips shall be used as accessories for laying conduits as directed by the Engineer-in-charge.
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
e) One bell point controlled by one switch
All as per item No. 5 here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 5 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through exisitng PVC conduit/casing capping of suitable size but not less than 20 mm dia on surface of stone/concrete wall /roof etc all as per site requirement including FRLSH,PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet with sink into the wall for mounting including laminated sheet cover 3mm thick laminated hylam sheet fixed with cadmium plated screws/PVC gang box fully enclosed type for mounting switches,sockets,fan regulator, etc including all accessories and making good the disturbed surfaces of walls and paint touch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge. Note: Inspection elbows, inspection Tees, self locking saddle clips shall be used as accessories for laying conduits as directed by the Engineer-in-charge.
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
All as per item No. 8 here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 8 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through new MMS PVC conduit of suitable size but not less than 20 mm dia concealed all as per site requirement including FRLSH,PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet with sink into the wall for mounting including laminated sheet cover 3mm thick laminated hylam sheet fixed with cadmium plated screws/PVC gang box fully enclosed type for mounting switches,sockets,fan regulator, etc including all accessories and making good the disturbed surfaces of walls and paint touch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge. Note: Inspection elbows, inspection Tees, self locking saddle clips shall be used as accessories for laying conduits as directed by the Engineer-in-charge.
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
e) One bell point controlled by one switch
All as per item No. 11 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing concealed PVC conduit upto 32mm including FRLSH, PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet box with 3mm thick laminated hylam sheet fixed with cadmium plated screws for mounting switches, sockets, fan regulator, etc including all accesories if required making good the disturbed surfaces of walls and paint tuch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge.
a) One light point controlled by one switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan point controlled by one switch and regulator
All as per item No. 13 here-in-before but with 4 Sqmm for 3 pin 5 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano flush type, single pole one way 6 Amps 240 volts ISI marked complete all as specified and as directed.
S&F in replacement of bell push,flush type, 6 Amps ,240 Volts ISI marked complete.
S&F in replacement of switch socket combination 2 in 1, 3 pin 6 Amps, flush type, universal ,240 volts complete all as specified and as directed
S & F in replacement of switch socket combination 2 in 1, 3 pin , 6 Amps/16 Amps, flush type,universal,240 volts complete all as specified and as directed
S & F in replacement of Call bell, ding dong, AC 240 Volts complete all as specified and as directed
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps flush type complete all as specified and directed.
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz single module size in 5 steps flush type complete all as specified and directed.
S & F in replacement of batten/angle holder, PVC/Polycarbonate type with back plate, 240 V , 50 Hz suitable for batten fittings complete all as specified and directed.
S&F in replacement of ceiling rose 6 A, 3 plate,PVC/polycarbonate ,insulated body 240 Volt , 50 Hz all as specified and as directed.
M&L for submain wiring along with earth wire with 3 x 4.0 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through existing PVC Conduit in wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable shall be measured as one unit length.
All as per item No. 24 here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 6.0 Sqmm copper cable shall be measured as one unit length.
M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length.
All as per item No. 26 here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length.
M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including Steel Conduit and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable and one run of steel conduit shall be measured as one unit length.
S&F of MS box made out of 2mm thick CRCA sheet CPRI approved factory made totally enclosed of size not less than box size - 1.5m x1.2m x 0.45m duly painted with two coats of powder coated paint over one coat of red oxide primer effectively sealed with PVC gasket for vermin proof and dust proof feature, mounted on wall, compartmentalised as per site requirement including arrangement of transparent glass for meter reading if required, provision for tapping incoming and outgoing electrical connections with suitable size of lugs, glands, and copper wire all as specified and directed by Engineer-in-charge.
Supply and fix distribution board double door type (for incoming MCCB & outgoing MCBs) TPN 8 way vertical type sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge.
All as per item No. 30 above but of TPN 4 way.
Supply and fix MCB distribution board single door type SPN 12 way sheet steel powder painted with bus bar ,neutral link & earth bar etc.with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and directed by Engineer-in-Charge.
All as per item No. 32 above but of SPN 8 way.
All as per item No. 32 above but of SPN 4 way.
Supply and fix sheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, "C" curve complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal powder painted triple pole and neutral enclosure with a three pin and earth plug and socket flushing in wall including 32 Amps rated 415 V, three pole MCB 10 KA, "C" curve complete all as specified and directed by Engineer-in-Charge.
S&F MCB Triple pole and Neutral (TPN) of capacity 40-100 Amps 415 volts ,breaking capacity 10 KA,'C' series ,fixed in proper position all as directed by the Engineer in charge .
Supply and fix MCB, SPN, 40-63 Amps, 240 Volts
Supply and fix MCB , SP, 6 - 32 Amps, 240 Volts
Supply and fixing MCCB 125 Amp three pole 415 Volt , breaking capacity 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge.
Supply and fixing MCCB 25-100 Amp Three pole 415 Volt , breaking capacity, 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge.
Supply & fixing wall mounted LED batten fittings extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 22W LED (4ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete including taking down old U/s fittings all as specified and directed by Engineer-in-Charge.
Supply & fixing wall mounted new LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 10W LED 6500K (2ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete including taking down old U/s fittings all as specified and directed by Engineer-in-Charge.
S&F LED light fitting in replacement of 10 watt bulk head luminaries complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply & fixing in replacement high efficacy recess luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal 18 W LED 5700K complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of high efficacy recess luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal 35/36 W LED (2ft X 2ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of high efficacy recess luminaire box type, high brightness 18 W round LED complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Disconnecting ceiling fans of any sweep and from any height including electrical connections, bringing down, dismantling, opening up, cleaning internally and externally, overhauling by replacing unserviceable items such as split pins, bearings, bushes, copper flexible cord, cotter pins and check nuts etc, lubrication with approved lubricants, reassembling including replacement of worn-out /defective parts and refixing for smooth functioning and connecting cable from ceiling rose to fan including testing complete all as specified and directed by the Engineer-in-charge.
Description all as per Ser item No.48 above here before but exhaust fan /wall mounting fan/Padestal fan of sweep 230/300/375/450 mm complete all as specified and as directed by the Engineer-in charge.
Notes for item No 48 & 49:- Replacement of unserviceable spare part required for servicing/overhaulingand rewinding of fans shall be measured and paid separately under relevent items after testing and commissioning vide relevent Item of this schedule.
Supply only the following parts in replacement of Ceiling/ Exhaust Fans of existing makes and size complete all as specified and as directed by the Engineer-in Chargre :-
(a) Capacitor 2.5 mfd capacity 240 volts. (Make ) : CAPCO/TIBCON
(b) Ball bearing of suitable size. (Make ) : NBC/SKF/TATA.
(c) Gun metal bush
(d) Copper flexible cord 3 core of size 23/00076
(e) Fan Clamp with rubber bush
(f) Down rod, 400 mm long
(g) Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
(h) Capacitor 4 mfd capacity 240 volts . (Make ) : CAPCO/TIBCON
(j) Ball bearing for exhaust fans of suitable size .
Taking out burnt copper winding wire from fan, cleaning the rotor shaft properly and rewinding with new super enamelled copper winding wire as per existing size/ gauge including heating/ varnishing etc complete as per manufacturer's design for the following fans:-
(a) Ceiling fan of 1200/1400 mm sweep
(b) Exhaust fan of 230/300 mm sweep
(c) Exhaust fan of 375/450/305/380 mm sweep
(d) Wall mounting/Padestal fan of 400/450 mm sweep
S & F in replacement of louvers with suitable frame work and fixing arrangements for exhaust fan of any size sweep complete including removing the existing unserviceable one all as specified and directed by the Engineer-in-Charge.
S & F in replacement of flap cover with suitable frame work and fixing arrangements for exhaust fan of size 230/300/450 mm sweep complete including removing the existing unserviceable one all as specified and directed by the Engineer-in-Charge.
Taking Down water heater (Electric Geyser) storage type of any make of 25 / 50 ltr capacity after disconnecting the existing electrical connection, water pipes and reassembling in all respects after replacing unserviceable parts/components and testing for proper working after repairs and refixing in the original place/position duly connecting up water supply and electric supply etc.complete all as specified and as directed by the Engineer-in-Charge.
Note :- Spare parts replaced shall be measured and paid separately under relevent items below. However labour cost of replacement is deemed to be included in the rate quoted.
Supply only the following parts in replacement of water heater (Electric Geyser) storage type of given make and size complete all as specified and as directed by the Engineer-in Chargre :-
(a) Thermostat ISI marked suitable for 25/50 litre capacity . Make -sphare hot /bajaj/ditz/picco/usha /racold .
(b) Heating element ISI marked 1500 watt 240 volts push/thread type circular/ triangular base for any make and type Make - bajaj / Racold
(c) Heating element ISI marked 2000 watt push/thread type circular /triangular base suitable for any make and size. Make - bajaj / Racold
(d) Indicator bulb 240 V suitable for given make, type and model
S & F in replacement of pressure release valve suitable for 25/50 litre capacity geyser including taking out the existing unserviceable one all as specified and directed by Engineer-in-Charge. Make -Sphare hot /bajaj/ditz/Picco/usha .
S & F in replacement of gasket rubber suitable for geyser of capacity 25/50 litre including taking out the existing unserviceable one complete all as specified.
S & F in replacement of non return valve gunmetal ISI marked for 15 mm bore with suitable fittings.Make - Kirloskar / Leader /Kartar .
S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for cold water connection.
S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for hot water connection.
S & F in replacement of PVC insulated and PVS sheathed flexible Copper Cable 3 core x 4.0 Sq mm from Geysers to socket.
S & F in replacement of plug top 3 pin 6 Amps 240 volts. Make : Anchor/Leader/Havells.
S & F in replacement of plug top 3 pin 16 Amps 240 volts. Make : Anchor/Leader/Havells.
S&F in replacement 400mm swing wall fan, 4star, smooth oscillation, copper motor with remote control, 72 speeds, plastic body complete all as specified and directed
S&F in replacement 400mm oscillating pedestal fan with tilt mechanism,smooth oscillation, 240V, copper motor plastic body with telescopic arranagement complete all as specified and directed
Supply and fixing in replacement LED building security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection with suitable no of nuts, bolts and clamps complete all as specified and directed by Engr-in-charge
Supply and fix in replacement electric water heater, storage type steel body with inner tank made of ultra thick super cold rolled steel plates and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece(hot and cold water connection pipe) etc complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed
All as per item No. 90 here-in-before but with 225mm sweep complete all as specified and directed
S&F in replacement heavy duty exhaust fan 300mm sweep, double ball bearings with bird protective guard, wall mounted, metallic body with minium noise level complete all as specified and directed
Supply and fix in replacement Exhaust fan, steel body, steel body AC Single phase 230 V of size 300 mm sweep with blades, and frame and louvers complete all as specified and directed by Engr-in-charge
Supply and fix 18" gold life smart down rod (Anti suicide fan rod) MS pipe zinc plated, 19mm OD, 1.8+/- 0.05mm thick, spring set grade 3 carbon steel material zinc plated, MSME tested for performance test and opening at impact load of 22 kgf + and spring hidden in pipe will expand to about 1 mtr or more, white colour for ceiling fans of any size with all accessories complete all as specified and directed by Engineer-in-Charge.
S&F All weather boxes with transparent lid of size 560x380x180mm, IP67, CIPET tested for outdoor installations, ABS body complete all as specified and directed by Engineer-in-Charge.
S&F All weather boxes with transparent lid of size 210x190x100mm, IP67, CIPET tested for outdoor installations, ABS body complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Weather proof flat twin core service cable size 16 Sq mm aluminium conductor PVC insulated and PVS sheathed.
Supply and fixing in replacement of Weather proof flat twin core service cable size 10 Sq mm aluminium conductor PVC insulated and PVS sheathed.
S & F in replacement of apparatus plate (bottom plate in which element and thermostate are fixed) complete suitable for 25 ltr capacity geyser including taking out existing unserviceable one all as specified and directed.
Maintenace of solar water heater of capacity 200/300/500 Ltr Capacity and checking the FPC collector,tank insulation and flanges all defective parts to be replace and paid separately.
Supply and fixing in replacement of the following parts of solar water heater storage type of existing make and size complete all as specified and as directed by the Engineer-in Chargre :-
(a) Aluminium dummy gasket
(b) EPDM Hole gasket
(c) Brass Flange
(d) Threaded Flange
S & F in replacement of apparatus plate (bottom plate in which element and thermostat are fixed) complete suitable for 50 ltr capacity geyser including taking out existing unserviceable one all as specified and directed.
Repairing/overhauling of TPN/SPN DBs of any size/type fixed on building wall incl cleaning with compressed air, tightening of all electric connection to the bus bar & switch gears , refixing of loosed doors with proper fixing & locking arrangement & necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster work as require at site and including disconnection of all cable/ sub main from the bus bar and insulating the neked portion of Al conductor and re-connect the same after repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed.
S&F in replacement of Flame proof weather proof LED Tube light fitting CMRI certified recommended for gas/ vapor group IIA and IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass suitable for 2 x 16 Watt (4 feet) LED tube lights, including all accessories such as drivers, tub lights, connector etc complete all as specified.
M&L for porcelain vitreous white seperators and fixing screws etc to be refixing along with the pole and wall with existing copper strip all as directed by Engr in Charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried 6cm dept in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing including porcelain vitreous white seperators and fixing screws with brazing at each possible joint etc. as required 32X6mm GI strip all as directed by Engr in Charge.
Supply, mix and pouring the magnesium sulphate either through the existing watering pipe of by making holes surrounding the earth pit @ the rate of 05 Kg per pit for charging the earth pit for improving the ER values including measuring and recoding the value to achieve the result less than 01 Ohm.
S&F in replacement of switch Modular type single pole one way 6 Amps 240 volts complete all as specified and as directed.
S&F in replacement of switch Modular type single pole one way 16 Amps 240 volts complete all as specified and as directed.
S&F in replacement of bell push,modular type, 6 Amps ,240 Volts ISI marked complete.
Supply only of residential water pump self priming regenerative 1HP single phase pump, voltage range 180V-260V, Head upto 34m, discharge upto 2700LPH, along with suction and delivery flexible pipes complete all as specified and directed.
Supply and fixing pressure booster pump 1/2HP, Single phase,high energy efficient design, head range upto 26m, flow rate 45LPM
S&F in replacement of socket 2 in 1, 3 pin 6 Amps, modular type, universal ,240 volts complete all as specified and as directed
S&F in replacement of socket 2 in 1, 3 pin 16 Amps, modular type, universal ,240 volts complete all as specified and as directed
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps modular type complete all as specified and directed.
S&F in replacment post top lanterns, 25W , IP65 long life aesthetically designed with symmetrical light distribution with high power LED , clear/opaque cover as per site requirement complete all as specified and directed.
S&F in replacement of existing Reading lights with 3W, 240V AC, 4000K flexible reading lights complete all as specified and directed (Philips Model No. 30975 or equivalent)
Supply and fixing in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed
Supply and fix in replacement 12W LED bulbs, cool day white, energy efficient, no visible flickering, glare reduction technology complete all as specified and directed
Rahul Enterprises (BID ID -3161340)
THE DECAN ENGINEERING AND REFRIGERATION COMPANY (BID ID -3160311)
Mavee Syndicate (BID ID -3170237)
SRI LALITHA CONSTRUCTIONS (BID ID -3167880)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .