Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B 52 CORPORATE HOUSE JUDGES BUNGLOW ROAD BODAKDEV AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | Admitted-Finance |
| 2 | Admitted-Finance OLYMPIA PLATINA PLOT NO 33B SOUTH PHASE GUINDY CHENNAI 600032 | CHENNAI | CHENNAI | TAMIL NADU | 600032 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical NOT ACCEPTABLE |
Tender Value
Refer Docs
Closing Date
22 Dec 2023, 3:00 pmClosed
SEKAR HIRUDHAYAM
TECHNIP ENERGIES INDIA LTD, CHENNAI
115 V AC UPS SYSTEM LOT 2 NUMALIGARH REFINERY LIMITED
2023_NRL_776222_1
TP/082176C/NRL/PQ/117
Open Tender
Electrical Goods/Equipment
Supply
270 days
NUMALIGARH
Please refer Tender documents
8 documents required · 8 mandatory
₹0
Exempted
26 Feb 2024
13 Oct 2023
23 Dec 2023
13 Oct 2023
22 Dec 2023
6 Dec 2023
Rating of 115V AC UPS 200kVA, 1Ph
AC UPS SYSTEM (MCR 2) 115V,100% Parallel Redundant UPS with Common Bypass. 115V,50Hz, 200kVA, 1Ph, 0.8pf, AC UPS system consisting of 2x100% parallel redundant configuration with common bypass, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 & Cell booster, as per typical SLD & as per requisition documents and shall include testing after erection, pre-commissioning & commissioning.
AC UPS SYSTEM (CR03), 115V, 100% Parallel Redundant UPS with Common Bypass. 115V,50Hz, 200kVA, 1Ph, 0.8pf, AC UPS system consisting of 2x100% parallel redundant configuration with common bypass, including Condition monitoring as detailed in the specification TP-1ZZZA-EL-SPE-0017 & Cell booster, as per typical SLD & as per requisition documents and shall include testing after erection, pre-commissioning & commissioning.
AC UPS SYSTEM (AC distribution panel) MCR2, 115V AC, single front, non-draw out, compartmentalized DB for AC UPS having two incomer and outgoers as per Feeder list & requisition documents and shall include testing after erection, pre-commissioning & commissioning.
AC UPS SYSTEM (AC distribution panel) CR03, 115V AC, single front, non-draw out, compartmentalized DB for AC UPS having two incomer and outgoers as per Feeder list & requisition documents and shall include testing after erection, pre-commissioning & commissioning.
Battery Set for UPS System, Vented Ni-Cd Type Set of Ni-Cd type Battery Bank (2 x 100%) as per the duty cycle attached part of the requisition along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning and commissioning.
Battery Set for UPS System, Vented Ni-Cd Type Set of Ni-Cd type Battery Bank (2 x 100%) as per the duty cycle attached part of the requisition along with Battery rack and other accessories as per SLD & requisition documents and shall include testing after erection, pre-commissioning & commissioning.
Miscellaneous Battery isolation breaker for each battery bank - flame proof (ex-d) suitable for installation in gas group II-C as per SLD & requisition documents for all the above battery banks supplied in this Lot (4 nos.)
Copper cables and accessories like lug and gland, etc. for interconnection of UPS system and its ACDB & UPS system and its battery - as per SLD & requisition documents for all the above UPS system supplied in this Lot. Refer note 16 of SOS
Special Tools and Tackles as per Manufacturer’s recommendation for the above 115V AC UPS
Special Tools and Tackles as per Manufacturer’s recommendation for the above 115V AC UPS Battery Bank. Other accessories (like Aprons and gloves) for safe and proper commissioning, operation and maintenance of the battery bank.
Special Tools and Tackles as per Manufacturer’s recommendation for the above 115V ACDB
Pre-Commissioning / Commissioning / Start-Up Spares As per Manufacturer’s recommendation for the above 115V AC UPS
Pre-Commissioning / Commissioning / Start-Up Spares As per Manufacturer’s recommendation for the above 115V AC UPS Battery Bank
Pre-Commissioning / Commissioning / Start-Up Spares As per Manufacturer’s recommendation for the above 115V ACDB
EXTERNAL TRAINING:Training to 2 Nos. of Owner personnel at OEM’s factory for 1 Week for the entire Package (Including Condition monitoring).
Training to 10 Nos. of Owner personnel at NREP Site for 1 Week for the entire Package (Including Condition monitoring).
Bidder shall provide Per Diem rate for Supervision services for Installation of the entire package and for Commissioning / Support Engineer from OEM shall be stationed at NREP Site for the duration of 1 month from the date of commissioning & handover for the entire package
Cost for Additional Warranty period of "24 months after commissioning or 36 months after dispatch whichever is earlier” over and above the Standard Warranty Period Refer Note-12
Hitachi Hi-Rel Power Electronics Pvt. Ltd.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .