Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC AT DHORI G M COLONY DIST BOKARO JHARKHAND | BOKARO | BOKARO | JHARKHAND | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | L2₹21.5 L+₹59,722 (2.86%)Rejected-Finance 159 KASIYADIH TANDWA CHATRA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | L2 | Rejected-Finance Bid not be opened as per NIT terms. | |
| 3 | Rejected-Technical AT PATEL NAGAR PO PHUSRO BAZA DIST BOKARO | PHUSRO BAZA | BOKARO | - | Rejected-Technical DIsqualified |
Tender Value
₹22.5 L
EMD Value
₹28,200
Closing Date
13 Feb 2025, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO(EnM), Dhori
Office of the General Manager, Dhori, Po- Dhori, Bokaro, pin-825102
Diversion of 3.3 kv OH line from Feeder breaker to karbala for smooth power supply to Amlo Basti, and Golepahari pumping in respect of AADOCM
2025_CCL_327412_7
GM(D)/SO(EnM)/DA/24-25/63
Open Tender
Electrical and Maintenance Works
Item Wise
30 days
AADOCM
please refer tender documents
2 documents required · 2 mandatory
₹28,200
30 May 2025
1 Feb 2025
14 Feb 2025
3 Feb 2025
13 Feb 2025
3 Feb 2025
3 Feb 2025 - 10 Feb 2025
Amount
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Erection of AA conductor of 7/2.11 mm to 7/3.00 mm dia meter & above including binding etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supply and erection of 11 KV pin insulator complete with large steel head GI pins nuts washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11KV overhead line with galvanized insulator, fitting ball and socket type and complete with galvanized stain clamps, bolts ,nuts, washers as required.
Supplying of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as rea u i red.
Erection of pole top / straight two wire, channel iron, cross arm on steel tubular pole for 11kv as required. Required.
Supplying of two lengths of channel iron 75 mm x 40 mm x 5.7 kg/mtr. double pole cross arm for three wire overhead line conductors complete with through bolts and nuts for clamping to the poles. 50 mm x 6 mm M.S flat welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arm together, incl. drilling holes for insulator pins/fittings, bolts and nuts etc. and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV over head lines as required
Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required.
Supply of 6 SWG GI wire for cradling in road crossing & earth wire continuity .
Erection of GI wire No. 8SWG including binding etc. as required.
Erection of cradle guard as required.
Dismantling of over head lines comprising of copper/aluminum over head conductor, G.I wire, cross arms, insulators etc. as required
Transportation of pole( store to Amlo transport Rail pole )
Transportation of pole Amlo transport to working side ( Rail pole )
Cleaning jungle including uprooting of rank vegetation grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 outside the periphery of the area cleared.
Supply of GOS 400A .
Fitting and fixing of GOS 400A
Supplying of channel iron 75 mm x 40 mm x 7.14 kg per mtr cross arm for 4 wire O/H line complete with clamps, bolts and nuts etc. including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paints as required.(15+19 with cradling .)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as reauired.
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supply and erection of earth pit
Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. 120 sqmm
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Supply of Barbet wire 46 x 8kg
Supply of danger board
Total impact of GST for the purpose of CTC
ARJUN ENTERPRISES (BID ID -1126153)
techsummary_339667.pdf
PDF • 0.42 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_339667.pdf
PDF • 0.27 MB
wo63G.pdf
PDF • 0.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .