Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAdmitted-Finance | ₹7.8 L | L1 | Admitted-Finance |
| 2 | L2₹8.0 L+₹15,150 (1.93%)Admitted-Finance GRAM KHAMARIA PARGANA SRINAGAR JANPAD LAKHIMPUR KHERI U P | LAKHIMPUR KHERI | UTTAR PRADESH | ₹8.0 L+₹15,150 (1.93%) | L2 | Admitted-Finance |
| 3 | L3₹8.1 L+₹27,150 (3.46%)Admitted-Finance PURAINA PURE HIMANCHAL HOUSE NO 123 MALAON PARASPUR GONDA | GONDA | UTTAR PRADESH | 271001 | ₹8.1 L+₹27,150 (3.46%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S J AND V INFRATECH PRIVATE LIMITED L3 | AMAR ENTERPRISES L2 | ANCHAL CONSTRUCTION L1 |
|---|---|---|---|---|---|---|
| 1.00 | Bore type Earthing and lowering "B" class G.I. Pipe (Gindal) of 50mm dia from ground upto water level not less than 40 feet, with G.I. strip of proper size as per standard /Estimate/Resspo Norms. (All the required material shall be given by contractor at his own cost.) | 56 | Nos. | 2,200 ₹1,23,200 Lowest | 5,000 ₹2,80,000 | 10,000 ₹5,60,000 |
| 2.00 | Construction of T/F plinth of size 2x2x1.5 mtr on a padding 0.25M deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr. Height and 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. brick work in ratio 1:4 cement and cores sand in the hollow portion the sand should be filled from the ground level up to 15 centimeter below from the top of wall, cement, sand and brick ballasts should be filled up to 15 centimeer. Two no. of channel 100x50 in length 1500mm will be grouted. 0.35 cm RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4. The T/F's plinth should be plastered on all sides 12mm thick in ration 1:6 by cement and cores sand. (All the required material shall be given the contractor on his own cost.) | 22 | Cu.m. | 25,000 ₹5,50,000 | 8,000 ₹1,76,000 | 2,500 ₹55,000 Lowest |
| 3.00 | FRP Fencing of Transformers (size 10X8X6 feet height including civil work) including single door and painting as well, as per estimate's requirement/as per RESSPO norms. (All the required material shall be given by contractor at his own cost.) | 38 | Sq.m. | 1,000 ₹38,000 Lowest | 6,000 ₹2,28,000 | 2,000 ₹76,000 |
| 4.00 | Complete Body and Neutral earthing with G.I. strip of proper size of Transformer as per Estimate/Resspo Norms(all the material shall be provided by contractor at his own cost.) | 65 | No. | 200 ₹13,000 Lowest | 1,000 ₹65,000 | 650 ₹42,250 |
| 5.00All these below items/materials from S.N. 6.01 to 6.04 shall be supplied and installed by the contractor at his own cost as per estimate/Resspo Norms. | ||||||
| 5.01 | Supply and Installation of G.I. Strip | 25 | Mtr. | 500 ₹12,500 | 300 ₹7,500 Lowest | 600 ₹15,000 |
| 5.02 | 1X70 sqmm cable for neutral earthing | 155 | Mtr. | 400 ₹62,000 | 160 ₹24,800 | 120 ₹18,600 Lowest |
| 5.03 | AL Lug of different size | 62 | No. | 150 ₹9,300 Lowest | 250 ₹15,500 | 250 ₹15,500 |
| 5.04 | MS Nut and bolt off size | 10 | Kg. | 300 ₹3,000 | 220 ₹2,200 | 150 ₹1,500 Lowest |
Tender Value
₹7.9 L
EMD Value
₹7,860
Closing Date
3 Jul 2026, 5:00 pmClosed
SE EDC GONDA
EDC GONDA
31/EDC(G)/2026-27
2026_MVVNL_1156836_2
NVS-30-46/EDC(G)/2026-27
Open Tender
Electrical Works
Item Rate
90 days
EDC GONDA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
SE EDC GONDA
₹7,860
Yes
EDC GONDA
7 Jul 2026
3 Jun 2026
4 Jul 2026
3 Jun 2026
3 Jul 2026
3 Jun 2026
6 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Bore type Earthing and lowering "B" class G.I. Pipe (Gindal) of 50mm dia from ground upto water level not less than 40 feet, with G.I. strip of proper size as per standard /Estimate/Resspo Norms. (All the required material shall be given by contractor at his own cost.) | 56 | Nos. | 100 | ₹5,600 |
| 2 | Construction of T/F plinth of size 2x2x1.5 mtr on a padding 0.25M deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr. Height and 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. brick work in ratio 1:4 cement and cores sand in the hollow portion the sand should be filled from the ground level up to 15 centimeter below from the top of wall, cement, sand and brick ballasts should be filled up to 15 centimeer. Two no. of channel 100x50 in length 1500mm will be grouted. 0.35 cm RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4. The T/F's plinth should be plastered on all sides 12mm thick in ration 1:6 by cement and cores sand. (All the required material shall be given the contractor on his own cost.) | 22 | Cu.m. | 100 | ₹2,200 |
| 3 | FRP Fencing of Transformers (size 10X8X6 feet height including civil work) including single door and painting as well, as per estimate's requirement/as per RESSPO norms. (All the required material shall be given by contractor at his own cost.) | 38 | Sq.m. | 100 | ₹3,800 |
| 4 | Complete Body and Neutral earthing with G.I. strip of proper size of Transformer as per Estimate/Resspo Norms(all the material shall be provided by contractor at his own cost.) | 65 | No. | 100 | ₹6,500 |
| 5All these below items/materials from S.N. 6.01 to 6.04 shall be supplied and installed by the contractor at his own cost as per estimate/Resspo Norms. | |||||
| 5.01 | Supply and Installation of G.I. Strip | 25 | Mtr. | 100 | ₹2,500 |
| 5.02 | 1X70 sqmm cable for neutral earthing | 155 | Mtr. | 100 | ₹15,500 |
| 5.03 | AL Lug of different size | 62 | No. | 100 | ₹6,200 |
| 5.04 | MS Nut and bolt off size | 10 | Kg. | 100 | ₹1,000 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
31.pdf
Tender Documents • 0.58 MB
BOQ_2167682.xls
BOQ • 0.25 MB
dtextensionTN31To42.pdf
PDF • 0.20 MB
3142.pdf
PDF • 0.18 MB
3145.pdf
PDF • 0.17 MB
3145.pdf
PDF • 0.18 MB
3146.pdf
PDF • 0.22 MB
TN31To46BP.pdf
PDF • 0.17 MB
3114.pdf
PDF • 0.26 MB
3046.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .