Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹14.8 L+₹2.0 L (15.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹14.9 L+₹2.1 L (16.0%)Rejected-Finance | L3 | Rejected-Finance 1485220.00 | |
| 4 | L4₹15.0 L+₹2.2 L (17.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
20 Feb 2020, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR AND MAINTANANCE LOW TENSION INSTALLATION LT EQUIPMENT, EARTHING, PERIMETER LED FLOOD LIGHTS AND MISC WORKS AT LGJ MIL STN
2020_MES_317752_2
8930-37/19-20
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class E Cat (b)(i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹30,000
Yes
GE Lalgarh Jattan
2 Mar 2020
8 Feb 2020
24 Feb 2020
8 Feb 2020
20 Feb 2020
13 Feb 2020
10 Feb 2020
Amount
Supply and fixing in replacement of 1100 volts grade heavy duty twin core cable PVC insulated sheathed aluminium stranded conductor of size 2.5 Sqmm for connection purpose complete all as specified and directed by the Engr-in-Charge. Make : Plaza, Finolex, Kalinga .
Supply and fixing in replacement brackets made out of GI tubing light grade 40mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing on poles/walls for street light fitting including before fixing applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge. Note :- Clamps and nut bolts for fixing as required shall be measured and paid separately under appropriate item.
M & L for Painting of PCC LT poles 9 Mtr including flat iron clamps, cross arm and channels on poles fabricated from mild steel including nuts, bolts, washers, with two coats of aluminium paint over a coat of red oxide primer after cleaning/ removal of dust etc. for preparation of steel surfaces all as specified and directed by Engr-in-Charge
Supply & fixing flood light fitting powder coated pressure die cast aluminium housing with mirror optic reflector toughened glass cover with high power LED 120 watt 240 volt 50 Hz and unique peanut lens with optics for uniform distribution with SMPS complete with drivers and LED, connectors prewired complete including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. Make : Bajaj Cat Part No BJFL 120W LED or equivallent in Havells/Crompton
Supply and fixing in replacement LT cable junction box, dust and water proof (IP65), out door type, made out of Polycarbonate with glass fiber re-inforced, size of box 200 x 160 x 98 mm with swiveling cover and locking clamp, pole mounting, consisting of aluminium bus bar strip 150mm x 20mm x 3mm, 4 Nos mounted on PVC insulator and provision of incoming/outgoing cables with grommets, including in built 6Amp MCB, SP, 9/10KA one No complete all as specified and as directed by Engineer-in-charge. Make :- Cat part K9250 of Hensel or equivalent in Sintex/Sagar Frp Industries Gurgaon Note :- (i) MS clamps and nut bolts for fixing the box along pole shall be measured & paid separately under appropriate item of this Schedule.
M & L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) in coping for electric poles or for stay assy etc. complete all as specified and directed by Engineer-in-chage.
M & L for GI pipe medium grade, size 40 mm, laid in trenches / fixed to pole / wall for cable protection complete all as specified and directed by Engineer-in-chage.
M&L for LED post top 40 watt made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete including fixing arrangement complete all as specified and directed by Engineer-in-chage. Make : Bajaj Cat Pt No BGCT W4 LED WW or equivallent make in Crompton/HPL/Havells.
S&F ACSR conductor of size as specified on LT/HT overhead line including all jumper connection and binding on insulator and taking down old one complete all as specified and directed by Engineer-in-chage.
Fixing only ACSR conductor of size as specified on LT/HT overhead line including all jumper connection and binding on insulator complete all as specified and directed by Engineer-in-chage.
S&F Galvanised steel wire 4 mm dia for and as earth wire on poles, 9/11 mtr or running straight including taking down complete all as specified and directed by Engineer-in-chage.
Material and labour for cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-chage.
S&F in repair LED driver suitable for 45 Watt LED fitting complete including surge protection device up to 10 KA all as specified and directed by Engineer-in-chage.
S&F in repair LED driver suitable for 60 Watt LED fitting complete including surge protection device up to 10 KA all as specified and directed by Engineer-in-chage.
S&F in repair LED driver suitable for 120 Watt LED fitting complete including surge protection device up to 10 KA all as specified and directed by Engineer-in-chage.
S&F in repair analogue time switch complete all as specified and as directed. Make : Indo Asian Cat Pt No 850121 or equivallent in L&T & HPL.
S&F in repair power Contactor 40 Amp 415 Volt having AC coil complete all as specified and directed by Engineer-in-chage. Make : Indo Asian Cat Pt No 850151 or equivallent in L&T & HPL.
S&F in repair shackle type insulator, porcelain, vitreous, white, brown or green of size 75mm height and 90mm dia for working pressure 1100 volts LT complete with insulator 12mm dia bolts, washers and nuts, MS strips of size 31 x 3 mm complete all as specified and directed by Engineer-in-chage.
S&F in repair pin type insulator, porcelain, vitreous, white, brown or green of size 75mm height and 90mm dia for working pressure 1100 volts LT complete with insulator 12mm dia bolts, washers and nuts, MS strips of size 31 x 3 mm complete all as specified and directed by Engineer-in-chage.
M&L for stringing drawing of GI wire 4 mm dia on LT electric lines including binding, jointing complete all as specified and directed by Engineer-in-chage.
S&F in repair guard craddle, made to shape hexagonal/rectangular or any other shape as required and directed, fabricated out of galvanised steel wire 4mm dia incl binding wire complete all as specified and directed by Engineer-in-chage.
S&F in repair stay assembly comprising GI stay bow 400x14mm, GI steel stay rod 1800mm long x 20mm dia with nuts, bolts, washers, GI steel plate 230X230X6mm, two nos thimble loop insulator of size 65X90mm clearance hole 20 mm and fixed to stay clamps galvanised stay stranded wire of reqd longth fixed to pole with size 7/2.5 mm including excavation, PCC work (1:3:6) type C-2 complete all as specified and directed by Engineer-in-chage.
M&L in repair danger notice plate of 1.6mm thick mild steel sheet ,vitreous enamelled, white, with letters, figures and conventional skull and bones in signal Red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20x15 cm size complete all as specified and directed by Engineer-in-chage.
S&F in repair GI Strip 32mm x 6mm for earth contunuity conductor fixed to wall and floor or buried in ground for loop earthing etc complete all as specified and directed by Engineer-in-chage.
Dismantling of existing LT pole any size/type from foundation in necessary earth work including dismantling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed by Engineer-in-chage.
Dismantling of existing stay assembly any type/size from its stay rod, putting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed by Engineer-in-chage.
Dismantling / taking out old ACSR / copper conductor /GI earth wire any size from existing over head lines including disconnection complete all as specified and directed by Engineer-in-chage.
Dismantling /taking out insulator of any size/type from existing electric LT lines complete all as specified and directed by Engineer-in-chage.
Dismantling /taking out old mild steel channel/agnle iron as in cross arms fixed to electric poles complete all as specified and directed by Engineer-in-chage.
Cutting/ Trimming of tree branches not exc 10 cm girth, touching/ approching the LT OH line, 3 mtr on either sides of LT over head lines mounterd on PCC/Steel poles and clearing the site by throwing the three branches and leaves etc.outside the MD land up to 100 mtr away complete all as specified and directed by Engineer-in-chage.
M & L for Cutting of grass, shurbs , bushes and small plants and their roots from the substation, receiving station and nearby transformers and electric installations and making neat and clean for safe working on installation and complete all as specified and directed by Engineer-in-chage.
S&F 5 mm thick MS chequred plate, made to shape & fixed on cable duct of Sub Stns including taking down old PCC duct covers complete all as specified and directed by Engineer-in-chage.
M & L for aggregate for loose filling of gauge, Hard core broken to gauge n exc 63mm in sub stations and main receiving station complete all as specified and directed by Engr-in-Charge
M&L for earthing in repair complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25 m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earthing strip of size 32 x 6mm flat by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and as directed.
M&L for Earthing in repairs complete with galvanised steel earth plate electrode 60 x 60 cm x 6.0 mm thick burried directly in ground earth pit not less than 2.25 Mtr deep below normal ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron earth Lead wire 4 mm dia as earthing lead by means of bolts, nuts, checknuts and washers of galvanised iron all as shown in electrical plate No 3 of SSR Part-I, connected to GODO / Lightening arrester / LT panel all as specified including GI pipe 20 mm bore medium grade for watering, PCC chamber using PCC 1:3:6 type C-2 CI frame and cover, funnel and wiremesh, all excavation and earth work etc complete all as specified and directed by Engr-in-Charge [Note for Item 34 & 35: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, RCC 1:2:4, Type B-1 cover 40mm thick reinforced with 8mm dia CTD bars @ 75mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in SSR Part-II and shown in electrical plate No. 3 of SSR Part-I.] (i) PCC chamber shall be constructed 1 m away from the earth pit and pipe for watering shall be provided in a slanting manner. (ii) The portion of GI strip burried in ground shall be protected by providing GI pipe 40 mm dia medium grade, the cost of which is deemed to be included in the quoted rates.
Dismantaling / taking out old / unsv LT panel of any size and type from the site after disconnecting the LT cables from the panel complete all as specified and directed by Engr-in-Charge
Fabrication and replacement of rusted LT panel doors by gas welding as per sample including painting and fixing with hinges complete all as specified and directed by Engr-in-Charge
Removing/scraping of rust from LT panels, preparation of surface for painting and painting of LT panels with more than 250 amps incoming MCCB with one coat of red oxide primer and two coats of synthetic enemel paint complete all as specified and directed by Engr-in-Charge
M & L for reinforced cement concrete (nominal mix) type B1 (1:2:4) using 20 mm graded stone aggregate for repairs of broken transformer foundation bed top complete all as specified and directed by Engr-in-Charge.
M&L for disconnecting transformer HT and LT side and shifting the same from the foundation for repairs of foundation including T&P for shifting of transformer complete all as specified including placing the transformer back in position after repairs and reconnecting the LT & HT side of cable complete all as specified and directed by Engr-in-Charge
M & L for Painting of channel link fencing Including props and gets all steel fabrication of various Sub stns at Lalgarh Jattan with aluminium paint of approved quality.
M&L for Preperation of old painted steel surfaces, installation desplay boards of any discription over 10 cm width/grith and applying one coat of synthetic enamel paint all as directed by Engineer-in-Charge
M&L Writing letters or figures (Block, Roman, Italic or indian) n.exc 30 cm high complete all as specified and directed by Engineer in Charge (measurement shall be carried out per CM of height). Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Ganganagar Enterprises
Aggarwal brothers and company
Lalgarhia Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .