| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC AOC34 | |
| 2 | L2₹17.1 L+₹3.4 L (24.7%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹17.1 L+₹3.4 L (24.9%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹19.7 L+₹6.0 L (43.4%)Rejected-Finance FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹22.0 L+₹8.3 L (60.3%)Rejected-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | L5 | Rejected-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | Kedar Electricals L3 | M/s ASPIRE ENGINEERING ENTERPRISES L4 | Shree Sai Samarth Enterprises L5 | SIDDHIVINAYAK ENTERPRISES L1 | SONA LAKSHMI ASSOCIATE L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for comprehensive and Routine maintenance/breakdown of DG set by deputing skilled service mechanics along with helper to attend the DG set regularly to carrying out scheduled preventive maintenance checks, Checking throughly the DG Set and finding out its faulty/defective parts and complete servicing /replacing defective spares of the DG set for smooth functioning of DG set of any Make all as directed by Engineer-in-Charge of following capacities:- NOTE: (I) The quoted rate deemed to be include the rate for following minor spares/ materials which are essential for smooth running of DG Set.
i) Fuel pipe any type including banjo nut, bolts & washers or as per sample.
ii) Cleaning, dusting of DG set and also including the cleaning and removing of vegitation surround the installation area.
iii) Aluminium/ Copper Lugs/ thimbles suitable for cable any size in AMF panel, near alternator complete all as directed.
iv) Necessary insulation tape.
v) Necessary guages like temp, oil pressure, oil temp gauges, all types of meters digital/ analog type on AMF paenel Complete all as directed.
vi) All types of relays fixed in AMF panel including Line voltage monitioring relay such as single phase preventor, phase sequence corrector, over load relay, over temp relay, short ciruit relay,control relay, timer etc.
vii) Any type of copper wire used inside the AMF panel for wiring including necessary connectors etc.
viii) Additional manpower during the break down or shifting of DG Set or its any heavy parts either inside this station or outside for major repair to workshop.
ix) Indicator Lamp on AMF panel.
x) Any type& shape nuts bolts as per existing or given sample.
xi) Toggle / selector switch also including push button for start and stop.
(II) Preventive Maintenance four visit in a year (qtrly based ).The major spare required for replacement to be measured and paid seperatly under respective items of this schedule.The Spare Parts, engine Oil & Coolant used for work under contract must be 'Kirloskar Care' genuine / recommended by Original Equipment Manufacture (OEM) Purchased from Authorised Kirloskar Care Service & Spare Dealership.
(III)If the contractor fails to perform comprehensive maintenance or breakdown services at a satisfactory level, including cleaning the surrounding area and all related tasks to maintain the DG Set to the required standard, a complaint will be communicated to him by this office representative either via telephone or his registered email. If he still fails to address the issue within 24 hours after being informed, he will be liable for a penalty of Rs 5000 per day for each DG Set, and this amount will be deducted from his RAR.
(IV)Note for item No 2 to 37 : These material shall be supply by dealer and fix free of cost under yearly maintenance /servicing.
Dg set of Capacity up to 25 KVA,Make-Kirloskar | 24 | Each job | 4,500 ₹1,08,000 | 8,000 ₹1,92,000 | 3,000 ₹72,000 | 2,500 ₹60,000 Lowest | 7,000 ₹1,68,000 |
| 2.00 | Dg set of Capacity of 30 KVA,Make-Kirloskar | 4 | Each job | 3,000 ₹12,000 | 9,000 ₹36,000 | 3,000 ₹12,000 | 2,500 ₹10,000 Lowest | 7,500 ₹30,000 |
| 3.00 | Dg set of Capacity of 40 KVA,Make-Cummins | 4 | Each job | 3,000 ₹12,000 | 10,000 ₹40,000 | 3,000 ₹12,000 | 2,500 ₹10,000 Lowest | 8,000 ₹32,000 |
| 4.00 | Dg set of Capacity of 62.5 KVA,Make-Kirloskar | 4 | Each job | 4,500 ₹18,000 | 12,000 ₹48,000 | 3,000 ₹12,000 | 2,500 ₹10,000 Lowest | 8,500 ₹34,000 |
| 5.00 | Dg set of Capacity of 100 KVA,Make-Kirloskar | 12 | Each job | 6,000 ₹72,000 | 12,000 ₹1,44,000 | 3,000 ₹36,000 | 2,800 ₹33,600 Lowest | 8,500 ₹1,02,000 |
| 6.00 | Dg set of Capacity of 200 KVA,Make-Greaves | 4 | Each job | 8,000 ₹32,000 | 16,000 ₹64,000 | 3,000 ₹12,000 | 2,900 ₹11,600 Lowest | 9,000 ₹36,000 |
| 7.00 | Dg set of Capacity of 250 KVA,Make-Greaves | 8 | Each job | 9,000 ₹72,000 | 18,000 ₹1,44,000 | 3,000 ₹24,000 Lowest | 3,400 ₹27,200 | 9,500 ₹76,000 |
| 8.00 | Dg set of Capacity of 320 KVA,Make-Greaves | 4 | Each job | 9,500 ₹38,000 | 25,000 ₹1,00,000 | 3,500 ₹14,000 Lowest | 4,000 ₹16,000 | 10,000 ₹40,000 |
| 9.00 | Dg set of Capacity of 365 KVA,Make-Cummins | 4 | Each job | 10,000 ₹40,000 | 30,000 ₹1,20,000 | 3,500 ₹14,000 Lowest | 4,500 ₹18,000 | 10,000 ₹40,000 |
| 10.00 | Supply repalcement of following spares for DG Set of capacity 15 KVA to 25 KVA.Note:The following parts used for work under contract must be recommended by the Original Equipment Manufacturer (OEM).
Diesel fuel filter part no.700000793493 | 6 | Each | 730 ₹4,380 Lowest | 900 ₹5,400 | 1,800 ₹10,800 | 2,500 ₹15,000 | 1,000 ₹6,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Jun 2025, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR/REPLACEMENT AND MAINTENANCE OF VARIOUS CAPACITY OF DG SET AND CONNECTED ITEMS IN 25ED AF STN DEVLALI
2025_MES_707703_1
8311/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹60,000
17 Dec 2025
13 May 2025
12 Jun 2025
14 May 2025
10 Jun 2025
27 May 2025
Amount
Dg set of Capacity of 30 KVA,Make-Kirloskar
Dg set of Capacity of 40 KVA,Make-Cummins
Dg set of Capacity of 62.5 KVA,Make-Kirloskar
Dg set of Capacity of 100 KVA,Make-Kirloskar
Dg set of Capacity of 200 KVA,Make-Greaves
Dg set of Capacity of 250 KVA,Make-Greaves
Dg set of Capacity of 320 KVA,Make-Greaves
Dg set of Capacity of 365 KVA,Make-Cummins
Supply repalcement of following spares for DG Set of capacity 15 KVA to 25 KVA.Note:The following parts used for work under contract must be recommended by the Original Equipment Manufacturer (OEM). Diesel fuel filter part no.700000793493
Lub Oil Filter part no.605411880009
Air filter(Inner and Outer) part no.700000793450
Hose Pipe set
V belt set
Supply Disel fuel filter part no.001200240911 For Capacity 30 KVA DG Set make-Kirloskar
Supply Disel fuel filter For Capacity 40 KVA DG Set make-Cummins
Supply Disel fuel filter part no.001200240911 ,For Capacity 62.5 KVA DG Set make-Kirloskar
Supply Disel fuel filter part no.001200240911 For Capacity 100 KVA DG Set make-Kirloskar
Supply Disel fuel filter part no.001200240911 For Capacity 200 KVA DG Set make-Greaves
Supply Disel fuel filter part no.001200240911 For Capacity 250 KVA DG Set make-Greaves
Supply Disel fuel filter part no.001200240911 For Capacity 320 KVA DG Set make-Greaves
Supply Disel fuel filter part no.FF5540 For Capacity 365 KVA DG Set make-Cummins
Supply lube oil filter part no.605411880009 For Capacity 30 KVA DG Set make-Kirloskar
Supply lube oil filter part no LF16061 For Capacity 40 KVA DG Set make-Cummins
Supply Lube oil filter part no.605411880009 ,For Capacity 62.5 KVA DG Set make-Kirloskar
Supply Lube oil filter part no.605411880008 For Capacity 100 KVA DG Set make-Kirloskar
Supply Lube oil filter part no.605411880008 For Capacity 200 KVA DG Set make-Greaves
Supply Lube oil filter part no.605411880008 For Capacity 250 KVA DG Set make-Greaves
Supply Lube oil filter part no.605411880008 For Capacity 320 KVA DG Set make-Greaves
Supply Lube oil filter part no. FF5540 For Capacity 365 KVA DG Set make-Cummins
Supply Air filter (Inner and outer) For Capacity 30 KVA DG Set make-Kirloskar
Supply Air filter(inner and outer) For Capacity 40 KVA DG Set make-Cummins
Supply Air filter (inner and outer) ,For Capacity 62.5 KVA DG Set make-Kirloskar
Supply Air filter (inner and outer) For Capacity 100 KVA DG Set make-Kirloskar
Supply Air filter (inner and outer) For Capacity 200 KVA DG Set make-Greaves
Supply Air filter (inner and outer)For Capacity 250 KVA DG Set make-Greaves
Supply Air filter (inner and outer) For Capacity 320 KVA DG Set make-Greaves
Supply Air filter (inner and outer) For Capacity 365 KVA DG Set make-Cummins
Supply V belt/Fan belt for DG Set of capacity 62.5 KVA to 100 KVA
Supply V belt/Fan belt for DG Set of capacity 200 KVA to 365 KVA
Supply Hose pipe set for DG Set of capacity 62.5 KVA to 100 KVA
Supply Hose pipe set for DG Set of capacity 200 KVA to 365 KVA
Supply current transformer as per existing sample
Supply only distilled water in packed PVC container for lead acid battery complete all as directed.
M& L for cleaning and descaling of radiator assembly by using suitable chemical and blower fan ,injecting water with high pressure in water tubings so as to remove all dirts in the fins, taking down the copper bottom portion of tank for welding / brazing and refit the same after replacing the unserviceable and damaged fins tank cap rubber bush and refix the same at the engine of DG sets complete all as per manufacturer's instructions and as directed.
M&L for Loading & Unlaoding of Main Alternator up to 25KVA( Disconnecting/assembling)
M&L for Stator Servicing/repair up to 25 KVA (Exciter/Main)
M&L for Stator Rewinding up to 25 KVA (Exciter/Main)
M&L for Rotor Servicing/repair up to 25KVA (Exciter/Main)
M&L for Rotor Rewinding up to 25 KVA (Exciter/Main)
M&L for Loading & Unlaoding of Main Alternator 25 to 62.5 KVA( Disconnecting/assembling)
M&L for Stator Servicing/Repair of 25 to 62.5 KVA (Exciter/Main)
M&L for Stator Rewinding up to 25 to 62.5 KVA (Exciter/Main)
M&L for Rotor Servicing/Repair up to 25 to 62.5 KVA (Exciter/Main)
M&L for Rotor Rewinding up to 25 to 62.5 KVA (Exciter/Main)
M&L for Loading & Unlaoding of Main Alternator 63 to 365 KVA( Disconnecting/assembling)
M&L for Stator Servicing/Repair of 63 to 365 KVA (Exciter/Main)
M&L for Stator Rewinding up to 63 to 365 KVA (Exciter/Main)
M&L for Rotor Servicing/Repair up to 63 to 365 KVA (Exciter/Main)
M&L for Rotor Rewinding up to 63 to 365 KVA (Exciter/Main) Note for item no 45 to 60 :- (a) The rate includes complete material require for repair, overhaul, calibration to make part serviceable . (b) The Rate includes taking out spare from the DG Set ,transportation to Original Equipment Manufacture (OEM) repair workshop , carrying out repair, overhaul, calibration , transportation back from workshop for fixing the same on the DG Set and testing the DG Set complete till satisfaction of Engr-In-Charge.
M&L for painting to the entire body of DG sets including canopy enclosure by scrapping out (and flames if necessary) the old paints , denting, spray painting to the entire body of DG set with minimum two coats of synthetic enamel paint to achieve bright finish of military green colour over a coat of primer and writing of MES/SM No of DG set all as directed. of the following capacity of DG sets up to 25 KVA .
All as above item No.61 but above but capacity 25 to 63 KVA
All as above item No.61 but above but capacity 100 KVA to 365 KVA
Repairs to broken disconnected door of DG Set by welding with new hinges, of suitable sizes , supply and fix new door locks as per existing complete all as directed for smooth opening and closing of door .
Supply and fill coolant of standard specification for top up in radiator of Diesel Engine of any size all as specified and directed
S&F in repair anti vibration pad Make : Dunlop or equivalent as approved by GE complete all as specified and as directed.
S&F in repair AVR of Suitable capacity applicable for 40 to 100KVA DG Set all as specified and as directed.
Supply and fix in repair high pressure fuel line with end coupler complete from FIP to injector with new high pressure line fixed properly (without any leakage) to the engine complete all as per manufacturer's instructions and as directed.
M& L for draining out old engine Oil from Chamber of the DG Set Of any capacity ,cleaning of chamber thoroghly and filling new engine oil of grade 20W40 Complet all as specified and directed.
S&F in repair copper terminal heavy duty for battery (length 1.5m ) connection with suitable size of copper lugs on one side and brass lead at other end all as directed.
Dismantling the exhaust pipe of DG sets at site, carry out necessary repair by necessary welding works and refix the exhaust pipe at the same location all as directed by Engineer-in-charge.
Lifting, loading and transportation of lead acid battery to work shop and repair to lead acid battery of 12 volt of 90/130/180 AH by filling up of distilled water, change of worn out cells, changing of unserviceable electrode/ electrolyte and changing of unserviceable terminal and taking back to MES store yard refixing for its original position etc complete all directed .
S&F in repair Generator controller suitable for 25 KVA DG set of KOEL Green, complete all as per manufacturer's instructions and as directed.
S&F in repair Generator controller suitable for capacity 63.5 KVA to 250 KVA DG set of KOEL Green,as per site requirement, complete all as per manufacturer's instructions and as directed.
S&F in repairs Air Break switch,gang operated triple pole mechanically operated & mounted on insulator and steel frame with operating mechanism and locking arrangement worked from ground level for current rating up to 200 Amps,11000 volts all including fixing and moving contacts,post insulators,operating rod,handle etc with necessary connection/jumpers with suitableACSR Conductor with heavy duty alkathene pipecomplete all as specified and directed by engineer in charge.
S&F in repairs DO Fuse 100 Amp 11KV with necessary connections/jumpers with suitable ACSR Conductor complete all as specified and directed by engineer-in-charge.
S&F in repair(HT) lightening arrestor expulsion type with all fittings,65 kilo amps discharge capacity working pressure 11000 volts,distribution class including inter connecting with & including GI strip 25x4 mm duly insulated on pole up to test point complete all as specified and directed(Set of Three).
M&L for boring hole under the existing road,Pavement,Hard standing not less than 0.7 meter below GL by trnchless technology using ultrasound Technique by bdoing excavation at both side and Passing the seamless 150 mm dia HDPE Pipe suitable for 0.4 mpa working pressure.All as specified and directed by engineer-in-charge.
Supply and fix battery secondery lead acid, 12 Volt 180 AH, heavy duty, maintenance free, electrolyte filled and initial charged complete with . Make: Exide heavy duty or Equivalent.
Supply and fix battery secondery lead acid, 12 Volt 90 AH, heavy duty, maintenance free, electrolyte filled and initial charged complete with . Make: Exide heavy duty or Equivalent.
M & L for rewinding of self starter coil, 12 Volts or 24 Volts any rating , with existing size of copper winding wire including varnishing and replacement of bush bearing, carbon bush, clutch plate set, pinion etc for DG set complete all as directed .
M & L for replacement of ignition switch with key and wiring complete suitable for 25 KVA to 200 KVA all as directed by Engr-in-Charge.
S&F in replacement of Solenoid Switch 12 Volt/24 volt suitable to 25 KVA to 200 KVA DG Set or as per existing complete all as directed
S&F Temperature sensor 120 deg cel,suitabale for DG Set Make Kirloskar
S&F Lube oil Pressure sensor 120 deg cel,suitabale for DG Set Make Kirloskar
S&F Tyre of Cover outer Size 7.50-16,make-Mrf or Equivallent complete all as directed by Engineer in charge.
Material and labour for earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm by means of of galvanized iron nuts & bolts or as directed at site by Engineer -in-Charge protected by GI Pipe 40 mm dia light grade and connected to test point and further connected to equipment, mcachinery, electrical panel or any other as directed by Engineer-in-Charge, which to be earthed, all as shown in electrical plate No 3 of SSR Part I including providion of concrete earth pit constructed in PCC 1:3:6 type C-1 as earth pit and PCC 1:2:4 type B-1 for cover slab with necessary reinforcement with handle for lifting also including provision of funnel with wiremesh with 20 mm GI pipe medium grade for watering, charcoal and salt in alternative layers of 15 cm thick all around the electrode , including necessary excavation and earth work , testing and commissioning complete all as directed at site.
All as per item No.17 above but by using with copper earth plate electrode of size 60cm x 60 cm x 3.0 mm thick and copper strip 20 x 3 mm as earth continuity conductor complete all as directed by Engineer-in-Charge.
Supply & Fixing LT XLPE insulated armoured heavy duty cable 1100V with stranded alumium conductor, Cross sectional area 35 Sqmm 3.5 core including necessory connection with privision of lugs and cable gland & fixing arrangement all as specified and directed.
Opening of the AMF panel by unscrewing screws, nuts bolts etc after removing all connection to DG sets and LT panel and reassemble the AMF panel after repair / replacement of worn out parts including fixing only the serviceable parts/ new parts complete including all connection, commissioning and testing complete all as specified and directed.
Supply 4 pole Power contactor ,MCX 33 ,Ac rating 200 A,Make-L&T or Equivalent .Complete all as directed by Engineer-in-charge.
Supply 4 pole Power contactor ,MCX 34 ,Ac rating 255 A,Make-L&T or Equivalent .Complete all as directed by Engineer-in-charge.
Supply 4 pole Power contactor ,MCX 44 ,Ac rating 560 A,Make-L&T or Equivalent .Complete all as directed by Engineer-in-charge.
Supply contact kit for 4 pole Power contactor ,MCX 43 ,Ac rating 400 A,Make-L&T or Equivalent .Complete all as directed by Engineer-in-charge.
Supply ,On Load Change over Swutch 415 v AC,Rated current 630A,Suitable for horizontal as well as vertical mounting,Make-L&T or Equivalent,Complete all as directed by Engineer-in-Charge.
SONA LAKSHMI ASSOCIATE (BID ID -3306807)
Kedar Electricals (BID ID -3318572)
M/s ASPIRE ENGINEERING ENTERPRISES (BID ID -3318353)
Shree Sai Samarth Enterprises (BID ID -3311742)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .