Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹36.8 L
EMD Value
₹92,055
Closing Date
29 Nov 2025, 11:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Forest Department
VIJAYAKUMAR KALAPPANAVAR-ACF
DESIGN, PROCUREMENT & SUPPLY, CONSTRUCTION & ERECTION, TESTING & COMMISSIONING OF DOUBLE TENTACLE SOLAR POWER FENCE AROUND MANJARIKOPPA TO MALESHANKARA- 6 KM OF SHIMOGA WILDLIFE RANGE
KFD/2025-26/OW/WORK_INDENT28707
KFD/2025-26/OW/WORK_INDENT28707
Open
Other Works
Two Tender Document System(Two Cover)
KFD DCF Wild Life Division Shivamogga
4 documents required · 0 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Proposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)
Upload all required technical qualification documents as per tender document
₹930
₹92,055
15 Nov 2025
15 Nov 2025
1 Dec 2025
20 Nov 2025
DESIGN, PROCUREMENT & SUPPLY, CONSTRUCTION & ERECTION, TESTING & COMMISSIONING OF DOUBLE TENTACLE SOLAR POWER FENCE AROUND MANJARIKOPPA TO MALESHANKARA- 6 KM OF SHIMOGA WILDLIFE RANGE
ENERGIZER 24 V With the following specifications. Must be from a reputed company Must confirm to National and International standards of safety IS-302-2-76. INPUT VOLTAGE DC 24 V Switch to h...
SOLAR MODULE With the following Specification minimum 150 watts, 12 volts rating with minimum 10 years warranty against manufacturing defects and Solar charge controller to regulate the charging of...
BATTERY Must have 12 Volts, 100AH SOLAR GEL SOLARTRON BATTERY with at least 5 years guarantee and LOW MAINTAINANCE
LIGHTNING DIVERTER Must be capable of diverting stray lightening. The diverter assembly must be adjustable for spark gaps. Adequate earthing to be provided
EARTHING SYSTEM Must contain earth mixture capable of retaining moisture and8 MM dia stainless steel rod-non rusting quality of 4 feet long.
WARNING SIGNS Poly-ethylene plastic with statutory colors and signs.
LEAD OUT CABLE Must be double insulated withstanding
15 KV voltage and Inner core wire must be hot dip galvanized.
TOOL KIT (Cutting Pliers, Multi Meter, Double Ended
Spanner Digital Volt Meter)
STAINLESS STEELWIRE 1.5mm 304 grade single core non rusting quality for main line DOUBLE LINE AND MIDDLE LINE 4 FFET ABOVE GROUND LEVEL
S S ROPE 1.5mmcable non rusting quality for hanging line 3.75 MTRS FROM TOP
HIGH TENSILE WIRE 2.59mm ACSR (Aluminium conductor steel-reinforced cable) as foper as per IS 398-1996
PART 2 Earthing line (Horizontal Line to be layed on ground for earthing connection ).
BULLETS(Connectors)- of copper material coated with stainless steel or nonrustringalluminium alloy having an inner core hole size of 2.5mm diameter and min 1 cm length.
LIVE POST BUSH - UV stabilized, heat resistant, non electrical conductible poly propylene material for fixing inside the 50mmX50mm GI square tube into bottom fixture
ERECTION OF HANGING FENCE Erection of hanging fence, fixing ropes and wires as per the design and commissioning of solar power generating system. (GoK notification No. DES/SIP/PWX/04/2024 dated 12....
No. of labours assumed for 1km is Supervisor(Shift/Works/Technical)
Electrical wireman
VEGETATION CLEARANCE Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300m...
Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works as per drawing and technical specifications,...
Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works as per drawing and technical specifications,...
Poviding and laying in position M10 grade Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed 20mm down graded coarse aggregates and fine a...
Percentage additionalities for Formwork for the above PCC M10 work , as per CSR 2023-24, Pg No.111, sl no.1(a). (Basic rate considered is inclusive of area specific loading at 12Percent).
Providing and laying in position M20 Grade Cement Concrete for all Foundation works. The granite/trap/basalt crushed 20mm down graded coarse aggregates and fine aggregates as per relevant IS Codes...
Percentage additionalities for Formwork for the above M20 grade concerete work , as per CSR 2023-24, Pg No.111, sl no.1(a). (Basic rate considered is inclusive of area specific loading
at 12Percent...
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, la...
MODULE STAND, SYSTEM MOUNTING BOX, RAISER POST, ELEPHANT POST GUARD AND BOTTOM FIXTURE BELOW GROUND Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, truss...
Painting 6(a)(i) with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade One coats on old work as per specifications and as per directions of Engineer in ch...
6(b) System Mounting Box Consists of Housing box and Stand
A. Housing Box Double Gel Battery Box Console cabinet of size 600mm (Length) x 630mm (Depth including door) x 60mm(Height including canopy...
6(c) Raiser post Raiser post consists of
Part-A Vertical pipes of 4.25 height- 50mmx50mmx2mm thick respectively.
Part-B Horizontal T-frame of 0.9m length & 50mmx50mmx2mm thick fabricated to suit an...
Elephant 6(d) post guard Elephant post guard is provided to protect Post from elephant attack and is extended at the end of T-frame for 4ft & at the centre as well (as shown in dwg) by using suitable...
Bottom fixture below ground Made of 75x75x2mm wall thickness, ISI make GP or GA Square pipe. The pipes are manufactured conforming to IS- 1239 (Part-l) I 990 which has inner size of 71mm at both sides...
Routine cleaning of the existing fire lines Maintenance of Fire Line Cleaning existing fire lines and fire tracing to a width of 5 m. heaping and burning. Clearance of firelines and view lines in /na...
RAISER POST AND ELEPHANT POST GUARD Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position ...
Elephant post guard is provided to protect Post from elephant attack and is extended at the end of T-frame for 4ft & at the centre as well (as shown in dwg) by using suitable size pipe with the help o...
Manpower(1watcher for 4km fence) For 1 Km (PCCF(HOFF) KFD/DEV/B1/SSR/2/2024 E-1369487
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW-1_Estimate 01 TSF.docx
Tender Document • 0.14 MB
Solar Tentacle Fence.xlsx
Tender Document • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .