Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹37.6 L+₹25,200.60 (0.68%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹40.2 L+₹2.9 L (7.82%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹40.3 L+₹3.0 L (8.00%)Rejected-Finance H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹41.4 L+₹4.1 L (11.0%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
11 Aug 2021, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT
PROVN OF LT FITTINGS (LT CABLE) FROM BLDG NO T-11 TO T-40 AT CBS GHAROTA AND CERTAIN SPECIAL REPAIRS AT MAMUN UNDER AGE E/M OF GE (SOUTH) MAMUN
2021_MES_459262_1
GE(S)/M-17/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SOUTH MAMUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹98,000
Yes
1 Oct 2021
13 Jul 2021
13 Aug 2021
13 Jul 2021
11 Aug 2021
29 Jul 2021
Amount
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Description all as per srl item No 1.00 here-in-before, but exc 1.5 m and n. exc. 3.00m in depth complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for dry clean fine river sand as in sand cushioning to underground cable 23cm thick (8cm before laying & 15cm after laying cable) including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in pedestal/coping including necessary weathering and form work etc complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
S&F "as in repair" bulk head 10 W LED light fitting IP 43 in engineering plastic housing with clear primatic diffuser complete with all accessories, connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed.
S&F "as in repair" LED batten light fitting 20 Watt square batten, LED 6500K 2000 lumen, 1136mm length compairing of extruded channel in engineering plastic in silver grey colour with same colour plastic end cap, with frosted extruded ribbed diffuser to get glare free, smooth light distribution, with control gear & integrated electronic driver, 230 V etc with all accessories and making connections from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
S&F "as in repair" LED batten light fitting 10 Watt LED 6000K (2 feet long), with extruded aluminium heat shink, control gear, poly carbonate extruded diffuser & integrated electronic driver 230 volt etc complete with all accessories and making connection using 3 core, 0.50 sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc, complete all as specified and directed. Note :- CA number shall be written on each fitting before installation.
Supply and fixing of 60 Watts LED Street Light luminaire with 01 No spare LED driver of the same cap. and make. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete having efficiency >100Lm/w, available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing of 150 Watts LED Flood Light luminaire with 01 No spare LED driver of the same cap. and make. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete having efficiency >100Lm/w, available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Note for srl item No 09 to 13 above 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.
M&L for security light brackets with 1.5m long GI pipe 50mm dia medium grade, and fixed along the pole for security light including clamps 02 No's of size 25x4mm alongwith nuts, bolts and washers etc complete all as specified and directed.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of size 10 Sqmm x 2 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Description all as per srl item No 15.00 above, but cable of size 16 Sqmm x 4 core complete all as specified and directed.
Description all as per srl item No 15.00 above, but cable of size 35 Sqmm x 3.5 core complete all as specified and directed.
Description all as per srl item No 15.00 above, but cable of size 50 Sqmm x 3.5 core complete all as specified and directed.
Description all as per srl item No 15.00 above, but cable of size 70 Sqmm x 3.5 core complete all as specified and directed.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of size 70 Sqmm x 3.5 core including taking out existing cable from trenches or fixed to wall/pole or passing through ducts or pipe of any size, any core , complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
M&L for 50mm bore galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings such as MS clamps of size 25mm x 4mm, nuts, bolts, washers etc, complete all as specified and directed.
M&L for 80mm bore galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings such as MS clamps of size 25mm x 4mm, nuts, bolts, washers etc, complete all as specified and directed.
M&L for replacement of 80mm bore galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings such as MS clamps of size 25mm x 4mm, nuts, bolts, washers etc, incl. taking out old one complete all as specified and directed.
M&L for 100mm bore galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings such as MS clamps of size 25mm x 4mm, nuts, bolts, washers etc, complete all as specified and directed.
S&F for MCCB 4 pole 415 volts AC of capacity 160 Amps rating, microprocesser based thermal magnetic release with rupturing capacity 36 KA, including providing thimble for out going cables complete all as specified and directed.
S&F for MCCB 4 pole 415 volts AC of capacity 200 Amps rating, microprocesser based thermal magnetic release with rupturing capacity 36 KA, including providing thimble for out going cables complete all as specified and directed.
S&F for MCCB 4 pole 415 volts AC of capacity 250 Amps rating, microprocesser based thermal magnetic release with rupturing capacity 36 KA, including providing thimble for out going cables complete all as specified and directed.
Supply and erecting in true vertical position pre-stressed cement concrete poles of 9.0 metres long, 102mmx152mm at top and 102mmx289mm at bottom, class 10 including painting, alternative green and white strips of 30 cm wide upto 15m above ground level and making pole number in black colour over yellow circle paint externally complete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
Supply and fixing of pole mounted street light factory fabricated junction box of size 300 x 160 x 250 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including63A ,Three Phase four wire having four no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Sizehaving Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer complete all as specified and directed.
Supply, installation, connecting electrically and testing of street light panel box complete with Astronomical timer ,contactor rating 65 Amp, MCB 63 A TPN complete for mounted made out of CRCA sheet 1.6 mm thick, powder coated, having provision for Astronomical Timer, Contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement all as required at site, complete all as specified and directed.
Supply and erecting in true vertical position steel tubular swaged poles of 11.00 metres long, type 410 SP-55 complete with cast iron base plate, goose neck bracket, finial taper plug , bolt, nuts & screws as specified and painting internal surface with anti-corrosive paint and external surface painting up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, indoor, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 150 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 150 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
S & F Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade all as specified and directed.
S & F Shackle insulators porcelain, vitreous, white,brown or green insulator including one set of galvanised mild steel section of straps 31 x3 mm, dia of bolt 12mm alongwith iron washers and one galvanised iron nut, 75mm height, 95mm dia for 1100 volts grade all as specified and directed.
S & F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
M&L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat & two coats of aluminium paint complete all as specified and directed.
M&L for stay assembly comprising stay 14 mm dia and 40 cm long stay rod 20 mm dia and 1.8 m long threaded ends with nuts, mild steel plate 30 cm X 30 cm X 6 mm thick and two number of thimble etc. complete with accessories as shown in electrical plate No. 1complete all as specified and directed. Note:- Loop type insulator, stay clamps, excavation & earh work and concrete shall be measured and paid separately.
M&L for galvanized steel stay wire size 7/4.0 mm including bow and clamps for stay of poles complete all as specified and directed.
M&L for loop type insulator vitreous, poecelain, white/brown/green, large size, with overall dimensions 90 x140 mm, clearance of hole 25.5 mm complete all as specified and directed.
M&L for ACSR conductor (Weasel conductor 6 x 2.59 + 1 x 2.59 Al + Steel), of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables, complete all as specified and directed. Note:- 3% for sag shall be added.
M&L for galvanized steel wire 4mm dia complete all as specified and directed.
M&L for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 25x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M&L for replacement of earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 25x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I including taking out old mearthing materials after demolition complete all as specified and directed by Engr-In-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgrae compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 400 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 40 X 40X 5 mm frame with 4 no. legs size nit less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for complete and including the following :-
(i) Indicator set RYB -01 Set of 3 pcs.
(ii) Multifunctional digital panel meter suitable to display Amps, Volts, frequency etc including CT's of appropriate ratio -01 No
(iii) LT CT's along with Aluminium bus bar for metering purpose.
(iv) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgrae compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 500 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size nit less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for complete and including the following :-
(i) MCCB 4 pole 415 volts 250 Amp rating microprocesser based thermal magnetic release with rupturing cap 50 KA, - 1 No. as incomer.
(ii) MCCB 4 pole 415 volts 200 Amp rating microprocesser based thermal magnetic release with rupturing cap 36 KA, - 1 No. as outgoing
(iii) MCCB 4 pole 415 volts 160 Amp rating microprocesser based thermal magnetic release with rupturing cap 36 KA, - 1 No. as outgoing
(iv) MCB SPN 240 volts rating 63 amps, with rupturing capacity 36 KA, 'C' curve type,- 05 Nos as outgoing
(v) Indicator set RYB -01 Set of 3 pcs.
(vi) Multifunctional digital panel meter suitable to display Amps, Volts, frequency etc including CT's of appropriate ratio -01 No
(vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgrae compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 1000 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size nit less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for complete and including the following :-
(i) MCCB 4 pole 415 volts 250 Amp rating microprocesser based thermal magnetic release with rupturing cap 50 KA, - 1 No. as incomer.
(ii) MCCB 4 pole 415 volts 160 Amp rating microprocesser based thermal magnetic release with rupturing cap 36 KA, - 2 No. as outgoing
(iii) MCB SPN 240 volts rating 63 amps, with rupturing capacity 10 KA, 'C' curve type,- 10 Nos as outgoing
(iv) MCB TPN 240 volts rating 40 amps, with rupturing capacity 36 KA, 'C' curve type,- 2 Nos as outgoing
(v) Indicator set RYB -01 Set of 3 pcs.
(vi) Multifunctional digital panel meter suitable to display Amps, Volts, frequency etc including CT's of appropriate ratio -01 No
(vii) Onload change over switch in sheet metal enclouser of capacity 250 Amp, 4 pole, 415 volts, incl. electric connections complete - 01 Nos
(viii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgrae compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 400 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size nit less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including taking down existing LT panel complete and including the following :-
INCOMING
(i) MCCB 4 pole 415 volts 200 Amp rating with adjustable load setting with rupturing cap 25 KA, - 1 No
(ii) Multifunctional digital panel meter 3 phase, 415 volts, accuracy class 1.0 flush mounting 96mmx96mm complete including CT's-01 No
(III) Indicating lamp (LED type) set RYB -01 Set of 3 pcs.
(iv) Onload change over switch in sheet metal enclouser of capacity 200 Amp, 4 pole, 415 volts, incl. electric connections complete - 01 Nos
OUTGOING
(i) panel mounting socket 415 volts 63 amps, 5 pin, 3p+N+E with plug top - 02 Nos
(ii) panel mounting socket 415 volts 32 amps, 5 pin, 3p+N+E - 02 Nos
(iii) panel mounting socket 240 volts 32 amps, 2 pin, P+N with top plug - 02 Nos
(iv) panel mounting socket 240 volts 16 amps, 2 pin, P+N with top plug - 02 Nos
(v) MCB TPN 240 volts rating 63 amps, with rupturing capacity 10 KA, 'C' curve type, with top plug - 02 Nos
(vi) MCB TPN 240 volts rating 32 amps, with rupturing capacity 10 KA, 'C' curve type - 02 Nos
(vii) MCB SPN 240 volts rating 32 amps, with rupturing capacity 10 KA, 'C' curve type - 02 Nos
(viii) MCB SPN 240 volts rating 16 amps, with rupturing capacity 10 KA, 'C' curve type - 02 Nos
(ix) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
M/S Vijay Punj Constructions
M/S SHRI RAM BUILDERS
M/S HIMANSHU BUILDERS
Vijay Kumar Contractor and Engineers
KULBHUSHAN AGGARWAL
Bidder Name
KULBHUSHAN AGGARWAL
Vijay Kumar Contractor and Engineers
M/S SHRI RAM BUILDERS
M/S Vijay Punj Constructions
M/S SHAKTI ELECTRIC WORKS
M/S HIMANSHU BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .