Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
22 Oct 2026, 2:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Panel Interlocking or Route Relay Interlocking or Electronic Interlocking or IBH or Automatic Signalling or LC gate Interlocking or AFTC or SSDAC or MSDAC or HASSDAC or BPAC.
9 conditions · 2 needing a document upload
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V and Annexure-V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home page of IREPS portal for works tenders before submitting the e-tender. 1.General Instruction for E-Tenders on works contract--Chapter- I 2.Special Condition-General- Chapter-II
Opening of e-tender : 1. The e-tenders will be opened online using the IREPS portal anytime after tender closing time. No representative is required to be present for opening of e-tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders through the website after the opening of the tender. 2. The earnest money cost is to be paid through online banking facilities through the online portal and by giving the other details online on website www.ireps.gov.in. Note: For more details refer to Cl: 4 & 12 of General Instruction-Chapter-I for Submission of EMD, Cost of Tender Document and opening of e- tender.
Asansol Division: Balance work i/c/w Provision of Dual detection by MSDAC at Kulti.
69-SDSTE-ASN-2026-27~ER
69-SDSTE-ASN-2026-27
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹2.9 L
30 Sept 2026
30 Sept 2026
8 Oct 2026
83 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | Above/ 3379810.84 Below/P | ||
| — | 1.00 | — | — | ||
| Supply of Portable operator console for onsite programming of Axle Counters with required software for operation/programme/diagnostic of axle counter. This operator console should have minimum technical specification as - 13th Generation Intel Core™ i5 processor, Windows 11 Home , 39.6 cm (15.6) diagonal FHD IPS display with Intel Iris X Graphics, 512 GB SSD Solid State Drive, 16 GB DDR4 RAM,MS Office, Antivirus for 1 year. Make - HP/DELL/LENOVO. Inspection: Consignee. | — | — | — | 86,608.75 | |
| — | 3.00 | — | — | ||
| Supply of following materials as a set : - (i) Supply of Control card for evaluators of Multi Section DAC along with power supply card or Equivalent. Inspection: RDSO . (ii) Supply of Input / Output card for Evaluators for "detection Point" or Equivalent. Inspection: RDSO . (iii) Supply of Input / Output card for Evaluators for relay driver and final track clearance relay or Equivalent. Inspection: RDSO (iv) Supply of Double Rail contact assembly with track side EJB for MSDAC. Each set shall consist of track side Electronic unit, Double rail contact with cable and mounting accessories. Inspection: RDSO.. NOTE: Make of these materials to be as per make of MSDAC supplied against item No. 1 of Schedule-B | — | — | — | 18,21,608.79 | |
| — | 100.00 | — | — | ||
| Charging of lead acid cell (Secondary cell) of of 120 AH, 2V capacity as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. For this work required materials and charger to be arranged by contractor. Charging place in Railway area will be decided by Rly. site engineer. Inspection: Consignee. | — | — | — | 53,909 | |
| — | 1.00 | — | — | ||
| Supply of relay rack to accommodate 100 relays complete with fittings as per DRG.NO.S&T/C-20/2001 or latest Inspection: Consignee | — | — | — | 27,521.95 | |
| — | 1.00 | — | — | ||
| Erection, Installation , wiring of relay rack as per instruction of Rly site engineer and as per Drg. No. S&T/C/20/2001(modified). This work include ssupply of fuse block with fuse, bus bar, PBT terminal /Tagblocks, resistance, diodes, condensers, PVC wire as per RDSO Spec. No. IRS-S- 76/89(Amd-3) or latest (for wiring/inter-wiring of relay racks, CTRs, tagblocks) hylum sheet and other scaffolding materials to be supplied by contractor as per requirement.PBT terminals, PBT fuse block, PVC wire to be procured from RDSO approved firm. This work includes fixing of relays with base , interconnection wiring with ladder arrangement of relay rack and complete wiring of relays by soldering/termination of wire at relay base as per wiring diagram and fixing of fuse block, diodes, resistance, condensers, terminal blocks, bus bars and other equipments required for the approved system design complete with supply of erection materials. This also includes laying , dressing of cables, wires for relay rack, CTR, panel, IPS/power equipment with supply of thread, wire guide, ladder guide , masonary materials and reinstatement of floor, wall as per requirement. This includes status of relay to be indicated through LED indication on top of rack, lettering of each relay on rack strip and lettering/numbering of terminals, fuse for circuit used in brief. Rack to be fixed on rubber pad. Ladder arrangement to be done from relay rack, panel, IPS/power equipment as per requirement. Ladders and its accessories for this work to be supplied & fixed by contractor. | — | — | — | 89,494.22 | |
| — | 1.00 | — | — | ||
| Supply of CTR (cable termination rack) as per drg no. S&T/C-19/2001with supply of screwless disconnect type terminal 2 way/4 way , scaffolding materials, ladder for supporting cable, wire guide, NDT fuse with fuse block, lugs, sleeves , PVC wire as per specification No. IRS-S- 76/89(Amd-3) or latest(for wiring of CTR) and other necessary hardware as per Rly requirement and supply of erection materials. Terminals, PBT fuse block, PVC wire to be procured from RDSO approved firm. inspection: consignee | — | — | — | 48,420.76 | |
| — | 1.00 | — | — | ||
| Installation, erection, commissioning of CTR as per instruction of Rly site engineer and as per Drg no. S&T/C-19/2001 or latest with fixing of scaffolding materials, terminals, fuse block, wire guide, ladder guide for supporting outdoor cables, wires. This includes termination of outdoor cable on terminals with proper lugs, number sleeves as per diagram and laying, dressing of cables, wires including earthing of cable armours with suitable clamp and proper soldering with lugs on main earth electrode outside relay room. This includes laying of cable and termination at both ends at existing CTR & new CTR. This also includes lettering/numbering of terminals for circuit used in brief. | — | — | — | 6,240.91 | |
| — | 1.00 | — | — | ||
| For alteration work , necessary required Inter connection wiring with ladder arrangement from control panel to IPS to relay rack, battery & CTR. This includes interconnection, wiring with ladder arrangement between relay racks, CTRs, control cum indication panel and relay rack tag blocks for data logger. This also includes termination of cables / wires on all the above and dressing, bunching etc. As required at site. 16 sq. mm. cable to be used between IPS & it's battery duly soldered with good quality lugs in duplicate. From relay rack to panel wire should be of 40/60 core multicore cable of 1 sq.mm., 0.5mm dia., 16/0.2 mm for relays, 3/0.75 mm for MCBS and 10 sq.mm for power wiring. Indoor cable will be 60 x 1 mm /40 x 1 mm as per IRS-S-76/89, amd-2 or latest for interconnection. Supply of wires / cables by the contractor, shall be procured from RDSO's approved firm only & to be duly inspected. Note: necessary 40/60 multicore, 16/0.2 mm, 3.0.75 mm, 10 sq.mm cables required for wiring to be supplied by the contractor. | — | — | — | 77,354.69 | |
| — | 2.00 | — | — | ||
| Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn.No.IRS: S-76/89 (Amnd-3) or latest. Each coil should be of 100 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: RDSO | — | — | — | 11,582.6 | |
| — | 200.00 | — | — | ||
| Supply of 1 x 16 Sq.mm. (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 126 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: RDSO | — | — | — | 27,692 | |
| — | 50.00 | — | — | ||
| Carrying out relay alteration to the existing relay wiring / new relay wiring at relay rack/location box as per the approved circuit diagram. These work includes the releasing of existing unused wires and wiring the relays / new relay wiring using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection by consignee. All required materials like wire, soldering materials, paint etc. to be supplied by the contractor for execution of the work. | — | — | — | 15,265.5 | |
| — | 6.00 | — | — | ||
| Supply of IPS DC-DC converter 24-32VDC, 5 Amp /10 Amp or 60-66 V DC, 5Amp or 60-100V DC,1 Amp/3 Amp/5 Ampas per specification No. RDSO/SPN/165/2012, version-3.0 or latest. Make & rating of converter will be informed by Consignee during supply of materials. . Inspection: RDSO | — | — | — | 1,41,478.68 | |
| — | 6.00 | — | — | ||
| Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. | — | — | — | 35,079.78 | |
| — | 140.00 | — | — | ||
| Supply of fuse, non-deteriorating(2A/6A/10A/16A)type, [quantity as per Rly. Engineer]. Inspection: RDSO | — | — | — | 7,558.6 | |
| — | — | — | cylindrical(IRS-S-78/92) | ||
| — | 50.00 | — | — | ||
| Transportation of HDD machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) three (03) nos. Of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided alongwith drum - 02 nos. Note:- Fuel and all other items which will be required for laying of cable through HDPE pipe to be supplied by contractor. The work shall be executed as per site engineer. | — | — | — | 99,314 | |
| — | 500.00 | — | — | ||
| Supply of Half Round RCC pipes & collars of 300 mm outer dia& 250 mm internal dia (2 meter long) along with collars as per IS No. 458/2003 of NP type. Inspection: Consignee | — | — | — | 3,84,125 | |
| — | 1000.00 | — | — | ||
| Laying of half round RCC pipe after laying the cables in the trenches. | — | — | — | 24,490 | |
| — | 150.00 | — | — | ||
| Supply of GI pipe with threaded collar of 100 mm nominal bore as per Specification No. IS- 1239, medium grade, perforated of required length. Inspection : Consignee | — | — | — | 1,29,228 | |
| — | 150.00 | — | — | ||
| Laying, Fixing, installation of GI pipe with threaded collar of 100 mm nominal bore perforated of required length on bridge, below road/LXing/ track, on wall or at other site and laying of signalling cable/rod through it with supply of necessary materials as required for execution of this work. The work to be done as per instruction of Rly. site engineer. | — | — | — | 16,648.5 | |
| — | 10.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate, cement & sand to be supplied by the contractor). Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. | — | — | — | 41,093.3 | |
| — | 8.00 | — | — | ||
| Supply of earth electrode (GI PIPE) as per HQ/ER's typical Drg. No. SI/TYP/0097 dated 25.03.25. Inspection: Consignee | — | — | — | 13,287.52 | |
| — | 8.00 | — | — | ||
| Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S DRG. NO. S&T-1/2007 (or latest). Inspection : consignee. | — | — | — | 7,633.44 | |
| — | 8.00 | — | — | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm. x 6 mm. with length 5 mtr. or as per extant practice of Eastern Railway. As_ per HQ/ER's typical Drg. No. SI/TYP/0097 dated 25.03.2025 or latest. For apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Where required necessary holes to be drilled on the MS Flat. Full threaded bolts of 10 mm. dia. and length 40 mm should be welded in the apparatus cases in such a way that the MS flat at the apparatus case end can be fixed from outside or from inside (bolts of 10 mm. dia. and length 40 mm. should be supplied by the contractor). Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Sig. Cable as provided by Railway is also to be laid and terminated on Earth Electrode and to Gl Wire/GI Flat in Location Box. | — | — | — | 10,499.68 | |
| — | 8.00 | — | — | ||
| Provision of cement concrete enclosure for earth electrodes as per HQ/ER's typicalDrg. No. SI/TYP/0097 dated 25.03.25. Inspection: Consignee. | — | — | — | 5,164.96 | |
| — | 4.00 | — | — | ||
| Alteration/modification in the existing location boxes (full size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 12,176 | |
| — | 5.00 | — | — | ||
| — | 5.00 | — | — | ||
| — | 1000.00 | — | — | ||
| — | — | — | 61,870 | ||
| — | 100.00 | — | — | ||
| — | — | — | 1,160 | ||
| — | 50.00 | — | — | ||
| — | — | — | 580 | ||
| — | 40.00 | — | — | ||
| — | — | — | 4,846.4 | ||
| — | 1.00 | — | — | ||
| — | — | — | 53,519.66 | ||
| — | 30.00 | — | — | ||
| Supply and fixing of RCC Cable Route Marker as per Drawing of IRSEM , appendix-II ,drawing No. 15-D1.Inspection: Consignee | — | — | — | 16,956.6 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Cable_cut_HQ_JPO_94.pdf
ATTACHMENT
Station_Sketch_ULT.pdf
ATTACHMENT
MSDAC_Technical_detail.pdf
ATTACHMENT
GCCCorrectionslip11.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
GCC Correction Slip
ATTACHMENT
GCC Correction Slip2
ATTACHMENT
mergedGCCCorrectionslip3456.pdf GCC correction slip3456
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf GCC Correction Slip 7 8 9 10
ATTACHMENT
2018-CE-I-CT-9dtd.pdf
ATTACHMENT
Annexure-C.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
ALLANNEXURENEW.pdf
ATTACHMENT
msdackulti.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14.07.2022_2.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
mergedGCCCorrectionslip3456.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .