| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹30.3 L+₹46,270 (1.55%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹38.8 L+₹9.0 L (30.3%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Other than lowest bid |
Tender Value
₹42.7 L
EMD Value
₹85,320
Closing Date
15 Aug 2022, 6:00 pmClosed
Garrison Engineer (West) Jalandhar Cantt
Garrison Engineer (West), Kabir road Jalandhar Cantt
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION OF OTM ACCN IN ZONE-I UNDER GE (WEST) JALANDHAR CANTT
2022_MES_538969_1
GE/JAL(W)-34/2022-23
Open Tender
Civil Works
Item Rate
335 days
Garrison Engineer (West) Jalandhar Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer (West)
₹85,320
Yes
15 Sept 2022
18 Jul 2022
22 Aug 2022
18 Jul 2022
15 Aug 2022
2 Aug 2022
Amount
Attending of complaints from 0900 hrs to 1700 hrs by deploying elelctrician along with helpers for checking of existing electrical items iincluding carrying out repairs such as tighting of loose electric connections, repair/replacement of switches, sockets, switch boards, tube rod, light fittings,Distribution Board, MCBs , No light, short circuit, current leakage in bldg/DBs etc as required to make the item functional and to ensure continuous electric supply complete all as specified and directed. Note : (a) Replacement of electric fitting shall be measured and paid separately under respective items (b) Rate quoted deemed to be inclusive of T&P etc (c) The safety and insurance of persons/helper engaged in Execution shall be responsibility of contractor. (d) As the Nos of complaints shall be on required basis the financial effect to this is deemed to be included in the item.
Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors all as specified and directed.
Taking down unserviceable Submain/Service cable of any size as directed by Engineer-In-Charge.
M&L for point wiring in repair with PVC insulated, unsheathed single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into and including PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specified. Make of cable : Finolex/Havells/Plaza (a) One light / fan / call bell point controlled by one, one way switch.
(b) 5 amps socket on independent board
(c) 5 amps socket on same board
Do all as per ser item No- 4 above but with 2.5 sq mm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
Supply & fixing in repair switch piano flush button type single pole one way 5 Amps all as specified. Make: SSK/Havells/Cona.
All as item 8 here-in-before but single pole 5 Amps two way all as specified.Make: SSK/Havells/Cona.
Supply & fixing in repair bell push single pole 5 Amps all as specified.Make: SSK/Havells/Cona.
Supply & fixing in repair switch piano flush button type single pole 15 Amps.Make: SSK/Havells/Cona.
Supply & fixing in repair socket outlet 5 Amp flush button type all as specified.Make: SSK/Havells/Cona.
Supply and fixing in repair socket outlet 6 pin 5/15 Amps multi type.Make: SSK/Havells/Cona.
Supply & fixing in repair ceiling roses surfaces bakelite two three terminals 65 x 50 mm all as specified. Make: Anchor/SSK
Supply & fixing in repair lamp holder PVC, insulated body with back plate suitable for batten fittings all as specified.Make: Anchor/SSK
Supply & fixing in repair regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts Make : USHA/Orient/ Polar .
Supply & fixing in repair regulator electronic socket type 5 steps suitable for 1200/1400 mm sweep 230 volts Make : USHA/Orient/ Polar .
Supply & fixing in repair bell electric (ding dong) , AC, 230 Volts, single pole ,Make : Anchor
Supply & Fixing in repair MCB DP 240 volts 32/40 Amps in the existing DBs. Make: Legrand/Hagger/schneider
Supply & Fixing in repair MCB single pole , 240 volts, 6 to 32 Amps in the existing DBs. Make: Legrand/Hagger/schinder
Supply and fixing in repair MCB SPN 40 to 63 Amps . Make: Legrand/Hagger/schinder
Supply and fixing in repair MCB TPN 63 Amps . Make: Legrand/Hagger/schinder
Supply & fixing in repair MCB DB SPN double door suitable for MCBs 8 way make Legrands/L&T/Siemens all as specified
Supply & fixing in repair MCB DB SPN, double door suitable for MCBs 4 way make Legrands/L&T/Siemens all as specified
Supply & fixing in repair MCB DB TPN, double door suitable for MCBs 4 way make Legrands/L&T/Siemens all as specified
Supply & fixing in repair MCCB 4 pole of capacity 100 Amps with breaking capacity 16 KA including all electrical connections and fixing arrangment all as specified and directed by Engineer -in-Charge (Make : Siemens/Legrand/L&T/BCH)
S & F in repair distribution board VTPN, with 200 Amp rated bus bar , double door, 04 way 440 Volts with sheet metal enclosure 200 Amps busbar,Make-L&T/Legrand/Siemens
Supply & fixing in repair light fittings decorative LED lunminare for wall mounting multi colour ABS housing with ploycrabonate rings thermo set plastic lamp holder CITY 1 fitting along with 15 watt retro fit LED Spiral lamp complete all as specified and as directed.Make Havells/ Polycab/ Crompton
M & L for taking down existing T/L fitting 36/40 watt and change the connection suitable for LED Tube Rod including replacement of tube Rod with LED tube rod 20 watts & refixing the same all as directed .
S & F in repair surface mounted LED Battern with LED tube rod 2 Feet 10W internal surge protection device of 4 KV with voltage band 140-280V and making electrical connection to ceiling rose all as directed Make Havells, Bajaj , C & S
Supply and fix in repair box type CRCA tube light frame suitable for fixing of LED tube rod 20 watt complet all as specified and directed.
S&F new generation energy saving 50 Watt LED flood light, powder coated PDC aluminum body with toughened glass visor of Efficacy>100 Lm/W , 5700K, IP66. Make Polycab/Havells/CG
S& F LED tube light fitting 20 watt slim type use and through complete all as specrified and directed Make Havells, Bajaj , C & S
S & F in repair bulk head light with LED 10 W confirming to IP-66 ulta modern energy saving high brightness LED complete all as specified Make : philips/Havell's/Polycab
Supply and fixing of new generation, post top, energy saving spun luminaries aesthetically designed with symmetric light distribution, aluminium landscape luminaries with high power LED of 25 W as light source, with opal cover confirming to IP65. Make : Havells/ Polycab/ Philips
S & F in repair 36Watt 2 x 2 LED Ceiling fitting llight fitting utra modern designed, LED luminaire suitable for armstrong/Grid Celing, including Bracket nuts, bolts washer as required for fixing. Make : Havells/ Philips/ Polycab
Supply & Fixing LED Bulb 12 Watts.
Supply & fixing in repair Push type side holder suitable for 28 watt tube light fitting.
Supply & fixing in repair Push type side holder suitable for 36/40 watt tube light fitting.
M&L for submain wiring with two RUNS of single core 6 sqmm for main wire and one run of single core 6 sqmm as earth wire of stranded copper conductor PVC insulated unsheathed cables drawn through and including concealed in wall and necessary cutting and chasing rigid PVC conduit ISI marked not less than 20 mm dia and all accessories complete all as specified & directed.
M&L for submain wiring with two RUNS of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor PVC insulated unsheathed cables drawn through and including concealed in wall and necessary cutting and chasing rigid PVC conduit ISI marked not less than 20 mm dia and all accessories complete all as specified & directed.
Supply and fixing aluminium service cable PVC insulated flat or circular of size 10 Sqmm 2 Core complete all as specified and directed.
Supply & fixing Modular switch single pole one way 5 Amps all as specified. Make: As per sample.
Supply & fixing Modular switch single pole 6 Amps two way all as specified.Make: As per sample.
Supply & fixing Modular bell push single pole 6 Amps all as specified. Make: As per sample.
Supply & fixing Modular switch single pole 16 Amps.Make: SSK/Havells/Cona. As per sample
Supply & fixing Modular multi socket 3 pin and 2 pin 6 Amp all as specified.Make: SSK/Havells/Cona. As per sample
Supply & fixing Modular socket outlet 6 pin 6/16 Amps multi type with shutter.Make: SSK/Havells/Cona. As per sample
Supply & fixing Modular regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts. Make : As per sample
Supply & fixing Modular regulator electronic socket type 5 steps suitable for 1200/1400 mm sweep 230 volts Make : As per sample
Supply & Fix Bakelite Hylem sheet 3mm thick of size 10"x12",superior quality, including cutting of sheet to fix switch, socket & regulators , including unscrewing the exiting switch, socket, regulator and fixing the same on new sheet with new machine screws complete all as specified and directed.
All as per item No 51 but size 8" x 10" complete all as specified and directed.
All as per item No 51 but size 8" x 5" complete all as specified and directed.
M&L for earthing complete with GI steel earth plate electrod 60x60cmx6.00mm thick bouried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4 mm as earthing lead soldering/revated to earth plate at one end and connected DB by means of nut, bolts etc complete with PCC pit (1:3:6) type GI cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead all complete as specified and as per electric plate No.5 of SSR Part I
GULSHAN SINGH GHAI AND SON
UNITED ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .