Replacement of Air- conditioners at Control Room and Room no. 44 SE(Civil)-II room) in Zonal Office building Green Park in ward No. 150 under South Zone.
2026_MCD_288957_2
EEE/SZ/2026-27/NIT/41
Open Tender
Electrical Works
Percentage
30 days
Hauz Khas
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹2,500
27 Aug 2026
27 Aug 2026
4 Sept 2026
27 Aug 2026
4 Sept 2026
27 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 15 | PM | 334 | ₹5,010 |
| 2 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 2 | Each | 1,621 | ₹3,242 |
| 3 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation offollowing capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating | 2 | Each | 42,055 | ₹84,110 |
| 4 | S/I/T/ C of 4 KVA Voltage stabilizer having input voltage 150V - 270V and output voltage of 195 V -245 V . | 2 | Each | 3,361 | ₹6,722 |
| 5 | S/I/T/ C of extra copper pipe for Split AC | 15 | Metre | 838 | ₹12,570 |
| 6 | S/I/T/ C of extra drain pipe for Split AC | 16 | Metre | 106 | ₹1,696 |
| 7 | S/I/T/ C of extra electric wire 3 core , 4 sqmm. Electrical wire | 16 | Metre | 158 | ₹2,528 |
| 8 | S/I/T/C of stand for split AC | 2 | Nos | 788 | ₹1,576 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 15.54 MB
Tendernotice_2.pdf
PDF • 0.06 MB
atofcondition.pdf
Tender Documents • 9.37 MB
BOQ_337038.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].