Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAdmitted-Finance | ₹3.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.7 Cr+₹3.9 L (1.09%)Admitted-Finance | ₹3.7 Cr+₹3.9 L (1.09%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Finance | - | - | Not Admitted-Finance Others-NON-RESPONSIVE. |
| Sl No | Description | Qty | Unit | M/S PUJA ENTERPRISES L1 | NIRKON INDIA L2 |
|---|---|---|---|---|---|
| 1.00Details | |||||
| 2.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground leveland removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. | 801.45 | Sqm | 14.5 ₹11,621.03 Lowest | 18 ₹14,426.1 |
| 3.00 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.(excavation for foundation and plinth beam including the sub-base width and depth). | 713.41 | Cum | 139.58 ₹99,577.77 Lowest | 145 ₹1,03,444.45 |
| 4.00 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B). | 433.93 | Cum | 14.26 ₹6,187.84 Lowest | 18 ₹7,810.74 |
| 5.00 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 416.97 | Cum | 50.82 ₹21,190.42 Lowest | 55 ₹22,933.35 |
| 6.00 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). | 129.7 | Cum | 415.58 ₹53,900.73 Lowest | 425 ₹55,122.5 |
| 7.00 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. | 991.07 | Sqm | 329.83 ₹3,26,884.62 Lowest | 350 ₹3,46,874.5 |
| 8.00 | Providing designation 75 A brick work in C.M.(1 :6) in foundation & Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. | 54.78 | Cum | 5,069.29 ₹2,77,695.71 Lowest | 5,200 ₹2,84,856 |
| 9.00 | Providing designation 100A brickwork with fly ash lime brick (FLAG) confirming to IS:12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. | 390.44 | Cum | 4,363.57 ₹17,03,712.27 Lowest | 4,500 ₹17,56,980 |
| 10.00 | Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I. | 376.75 | Sqm | 562.92 ₹2,12,080.11 Lowest | 575 ₹2,16,631.25 |
Tender Value
₹3.6 Cr
EMD Value
₹7.2 L
Closing Date
17 Feb 2022, 5:00 pmClosed
EE, NREP, CHATRA.
VIKAS BHAWAN, CHATRA.
EE/NREP/CHATRA/09/2021-22/RE-1 CONSTRUCTION OF INDOOR STADIUM (ONE UNIT) AT -SARDHU RURBAN CLUSTER IN DIST. CHATRA
2022_RWD_55744_1
EE/NREP/CHATRA/09/2021-22/RE-1
Open Tender
Civil Works
Item Rate
180 days
TANDWA
TENDER FEE,EMD,AFFIDAVIT AND QUALIFICATION DOCS.
2 documents required · 2 mandatory
₹10,000
EE, NREP, CHATRA.
₹7.2 L
7 Mar 2022
9 Feb 2022
21 Feb 2022
9 Feb 2022
17 Feb 2022
9 Feb 2022
Amount
Details
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground leveland removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.(excavation for foundation and plinth beam including the sub-base width and depth).
Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B).
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing designation 75 A brick work in C.M.(1 :6) in foundation & Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 100A brickwork with fly ash lime brick (FLAG) confirming to IS:12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level.1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness), including attached pilasters, butterses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and struts ets. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15'' landing, balconies, shelver, chajjas , lintels, bands, plan window sills, staircases and spiral stair case above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for :Stairs,(excluding landings) except spiral-staircasess.
Centering and shuttering including strutting, propping etc. and removal of form for Weather shade,Chajjas, corbels etc. including edges
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform with water proofply 12 mm thick.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
Providing TOR steel reinforcement of 8mm, 10mm , 12mm , 16mm dia rods or bars as per approved design and drawing excluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Ltd, Bokaro and Vizal Steel)
(a) 8 mm (TMT coil Fe 500)
(b) 10 mm (TMT coil Fe 500)
(c) 12 mm to 16 mm (TMT coil Fe 500)
Providing TOR steel reinforcement of 20mm, 25mm , 28mm , 32mm dia rods or bars as per approved design and drawing excluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Ltd, Bokaro and Vizal Steel)
(e)20mm to 25 mm (TMT coil Fe 500)
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. 30 mm thick plain PVC door shutters
Supplying, fitting and fixing 35mm thick solid core type non decorative single leaf flush shutters in doors and windows with block board core blended with high quality pehnol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 35mm thick solid core type non decorative double leaf flush shutters in doors and windows with block board core blended with high quality pehnol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Extra for providing vision panel not exceeding 0.1sq.mm in all types of flush doors (cost of glass excluded) (overall area of door shutter to be measured)Rectangular or square
Providing and fixing PVC igid form sheet 1mm thick on existing door shutters (bthroom and WC doors) using synthetic rubber based adhesive
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/ sqm)
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete Twin rubber stopper
Supplying, fitting, and fixing 250 x 20 x 6mm L-type M.S. clamp properly fishtailed, including making holes and setting the same in 375x125x75mm. Cement concrete block ('1 .2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:- Fixing with adjustable lugs with split end tail to each jamb
Supplying, fitting, and fixing M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing , properly fabricated with joints continuous fillet welded and finished, carriage of grill to work site, hoisting as per building speficiation and direction of E/I. (where material is not supplied by the deppt.)
Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where material is not supplied by the deppt.)
Supplying,fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20X'10X2 mm. at 100mm. Centres and braced with M.S. flat diagonals 20 X 3mm, with top and bottom rails of T. iron 40x40x6mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification arrd direction E/|.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primerUsing M.S. angles 40x40x6 mm for diagonal braces
Providing and fixing stainless steel (grade 304) railing made of Hollow tubes, channels, plates etc,. Including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessry stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasterners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasterners etc,.)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Supply of color coated trapezoidal ‘’ LYSAGHT TRIMDEK 1072’’ Profile sheet manufactured by Tata BlueScope steel having nominal 1072 mm supply width nominal 28 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm center- to- center. The end rib shall be designed for anticapillary action, to avoid any seepage of water through the lateral overlap. The feed material shall be made out of COLORBOND Steel. The base metal shall be of High Tensile Steel of 550 MPa minimum yield strength with hot dip metallic coating of Zinc-Aluminum alloy (55% Aluminum, 43.5% Zinc and 1.5% Silicon) AZ150, of minimum 150 Gms/Sq.mtr total of both side as per ASTM A792 or AS 1397. The Base metal Thickness shall be 0.45 mm (BMT) and the Total Coating Thickness (TCT) shall be 0.50 mm. The Paint shall be Super Durable Polyester paint system, factory painted and oven backed with a total coated thickness of 35microns (nominal) as per AS/NZS 2728 Type 4. The exterior side shall comprise of 20 microns (Nominal) paint over 5 Microns (Nominal) corrosion inhibitive solvent based primer. The interior side shall comprise of 5 Microns (nominal) reverse / back coat over 5 microns (nominal) corrosion inhibitive solvent based primer. The pigments shall be in- organic ceramics based pigments. There shall be no lead content in the paint system
Ridge,Gable, Flashings of 300- 600mm Girth, made out of 0.45 BMT, COLOURBOND Steel. Fasteners: Self Drilling Screw with nominal 40 micron zinc coated, Hex head, as per AS 3566-2002 Class 3 fasteners of approved make (Bousted or equivalent) with EPDM washer.(12-14x55) &(12-14 x 30)Installation of Lysaght Sheets.(1072) with all accessories
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying Doublecharge vitrifed floor tiles in differents size (thickness to be i specrfred by lhe maiirifacturer) with water absorption less than 0.08% and conformrng to lS 15622 / SO 13006 of approved make, in all cotours and I shacjes laid on 20mrn tlrick'cement mortar 1 4 (1 cement:4 coarse Isancl) lointing witir grey cement slurry @ 3.3 kg/ sqm including I grouting tiie joints v/ith v/hite cement and matching pigments etc., I cornplete Size of l-ile 600x600 mm
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two laters, bottom layer 19mm thick (1:2:4) with 12mm to 6mm size graded stone chips and top layer 6mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l.
Provicling '12mm. cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor curing, taxes and royalty all complete as per building specification and direction of E/|.
Providing 12mm Thick cement plaster (1:6) with clean coarse sand F.M. 1.5 including screening, curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I
Providing 6mm Thick cement plaster (1:4) in ceiling with clean coarse sand F.M. 1.5 including screening, curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I
Providing 12mm thick waterproof cement plaster (1:4) with clean coarse sand F.M.1.5 with 5% cico or any other approved water proofing compound including curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I
Making 6x6mm grooves in plaster surface over walls truely horizontal or vertical as specified. at regular intervals, at all heights including cleaning, finishing, scaffoding and curing wth all leads and lifts of water all complete as per building specification and direction of E/|
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building speicification and direction of E/I.
Water proofrng for Old and New Roof Slab :- Providing and laying waterprooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible,material applied with brush, roller or spray for wate proof i n g coating as per manufactlrer specificatio With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dLrst, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from sofftt to identify seepage, leakage. On identiiication of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those betr,veen the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the sl u rry ?!gc!ylic polyrner Repai rin g su rface irreg ularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair moriar ir;cluding a coat of bonding agent of the same with ceme nt slurry rncluding all rnaterial, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, llexrble cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/SqmUcoat For the fJUrpose of n'ieasurernent tite entire treated surface will be measured."
(c) :2nd Cr:ai :-T,: apply the 2nd coat of two component acrylic modified, reatiy to-use, flexible cementttious material right angle to the '1st coat over the glass fibre liad surface. 2nd coat should be applied @0.7 kgl Sqrnt/coat. For the pltrpose of measurement the entire treated surface will be rneasurecl." Alte r three days of drying the 2nd coat, therainwater ouilets to be plugged and ponding test to be done for 48 hours to rrjerrtify se epage, leal<age from soffit and if found necessary rectification lo be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectifcation to be done as per satrsfaction of E/C protected from damage before screed over it. Watqr proofing Brand:*Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A. Acrylic copolmer, Part B Specially graded cementitious powder - Density 1.6 l.rg/l (mixcd density) at +27oC Tensile Strength - 2 lllmm2 after 28 clays (with Fibre cloth) (According to ASTM D 2370)Prillcut Bond Streric;tl-r '-2 I'J/mm2 (concrete lajlqry) (Aqgcrdlglq ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.'15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Clot (Accordrng to ASTM D 2370)
(d) Protection of treated surface with PCC- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( '1:120) towards tlre rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mrn gap betuieen the panel joint. lntegralwater proofing admixture conforming to lS 2645 @ of 100 ml per bag of of cement to be added in the scree d concrete(pard separately for thts ltems).-All corners shall be charrmfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface slrould be packed properly with rich concrete and the peripheral mouih to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose ofrreasurement the entire treated surface will be measured."
(e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc Warranty for Five years.
Providing & laying water proofing treatment in sunken portion of WCs, bathrooms etc. by applying cement slurry mixed with Armourcrete of M/S The Structural Water Proofing Company PVT. Ltd.or Tapecrete of M/s CICO Engg. Servce consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @ 0.125 kg/ sq.m. This layer will be allowed to air cure for 4 hours (b)second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @ 0.126 kg/ sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preperation of surface, treatment& sealing of all joints, corners, junctions of pipes & masonary with polymer mixed slurry.
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plarstered surface by rubbing smooth with pumice stone or fine sand paper, appiying putty wherever required, scaffolding washing of floor and taxes all complete as per buiiding specification and drrection of E/i.
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding, curing and taxes all complete as per bldg.specification and the direction of E/I.
Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surfaces including preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes, all complete as per building specifications and direction of E/I
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/l.
Providing 250 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 250 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse send : 6 graded stone aggregate 20 mm nominal size ) over 75 mm thick bed of dry brick ballast 40 mm nominal size ,wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Bend 87.5 degree (110x110x110mm)
Shoe (Plain) (110mm shoe)
Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete - 110mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less thaN 440 grams.
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 13.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 11.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long,
the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting /making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Weather shade,Chajjas, corbels etc. including edges
Suspended floors, roofs, landings, balconies and access platform with water proofply 12 mm thick.
Supplying,fitting and fixing M.S. grill gate with M.S. grills made of 20xGmm M S. flats or 16mm. M.S. square bars fitted on25x25x 6mm. M.S. Angle frame -do- (when steel is not supplied by the deptt.).
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required, scaffolding, washing of floors, and taxes, all complete as per building specifications and direction of E/I
Finishing walls with premium acrylic smooth exterior paint with sillicone additives of requited shade . New work : 2 or more coats applied @1.43 Ltr/10sqm over and including base coat of waterproofing cement paint applied @2.2 Kg/10 sqm
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Labour for fitting and fixing NP2 hume pipe with coars 150mm dia …………….do……….do of E/I.
Supplying of 150 mm dia NP2 hume pipe ………….do…………….do of E/I.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge
Drilling in all kinds of soil and rock in rural area for installation of IM-III HP with DTH Rig including supplying all materials, labours, tools. Drilling rig, air compressor and euipment as well as fuel. Lunricants for making 125mm/115mm dia broing and cost of transporting charge of rig machined and other supporting vechicles upto work site as per direction of E/I.
Carriage of Materials
Bricks / Flyash Brick (1K+ 7P = 8 KM.)
Coarse Sand (15 KM.)
Stone Chips ( 41 KM.)
Stone Metal ( 41 KM.)
Cement ( 7 km)
Steel ( T.M.T ) :- ( 7 Km )
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With "P" trap (b)10 lit. low level P.V.C. cistern
Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flush pipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I. (A) 580 mm long with 10 litre low level PVC cistern
Supplying, fitting and fixing flat back or angular lipped front vitreous white glazed earthern ware urinal of Hindustan "Parry" or any other approved ISS make with 5 ltrs. Capacity C.I. automatic flushing cistern of reliance for any other ISS approved make with all fittings with C.I. or RS brackets standard size G.I. flush pipe with fitting clamps 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 gms. 15mm PVC alkethene pipe 450mm long with brass coupling at both ends and doing plumber points including painting of exposed part with two coats of approved paint over a priming coat of red oxide cutting wall and floor making good the same etc. all complete as per speciifcification and direction of E/I. Flat back or standing corner (600X350mm)
supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I OR R.S bracket 32mm C.I brass waste 15mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I.
Supplying, fitting and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I.
20mm dia.
25mm dia.
32mm dia
Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I. … 15mm dia.
Cutting chajjas or concrete for laying GI Pipe and restoring the same with R.C.C. (1:2:4) brick work in cement Mortar (1:4) and cement plaster 1:4 as per specifiction and direction of E/I
Making holes in walls for GI Pipe and restoring the same atfer pipe Laying (b) 250mm thick wall
Cutting drain width wise above GL for laying HCI pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in C.M. (1:4) with neat cement punning as per specifciation and direction of E/I. (PVC 110mm dia)
Making holes in wall for laying HCI pipes and restoring the same all cost complete (HCI pipe 250mm dia)
Supplying all tools and labour and cutting chajja cornice for laying HCI pipes and making good the same as per specification and direction of E/I.
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) Pillar cock (Basic rate Rs.756.60 + 15% for C.P. & laying charge)
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) Bib cock - long thread (Basic rate Rs.701.10 + 15% for C.P. & laying charge)
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) Angular stop cock L.T.(Basic rate Rs.572.85 + 15% for C.P. & laying charge)
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) Glass shelf (Basic rate Rs.641.25 + 15% for C.P. & laying charge
Flush valve complete with 32mm size control cock & flange (Basic rate Rs3283.20. + 15% for C.P. & laying charge
32mm dia. PVC waste pipe 750mm long with Coupling (Basic rate Rs.133.40 + 15% for C.P. & laying charge
15mm C.P. nipple with coupling(As per JSR basic rate Rs.72.70 + 15% C.P. & laying charge)
Steel jali - 100mm dia. (Basic rate Rs.40.20 + 15% for C.P. & laying charge
Providing Solvent cement (as per JSR basic item - 228.55 + 15% C.P & laying charge
Supplying, fitting and fixing Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. (I)600 X 450mm
Supplying, fitting and fixing C.P. brass towel rail 20mm X 600mm with bracket container
Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc all complete as per specification and direction of engineer in charge
Supplying, materials and labour for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Basic rate Rs.5.40+15% for C.P.)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931, 15mm dia nominal bore of approved brand C.P. fittings
Providing and fitting C.P. brass angle vale basin mixer and geyer points of approved qulity confirming to IS 8931 15mm nom inal bore approved brand C.P. fittings
Providing and fixing PTMT extension nipple 15mm size with 12" BSP thread 70mm length and 30mm breadth and weighing not less than 18gms of approved make
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc.
15mm nominal bore
20mm nominal bore
25mm nominal bore
32mm nominal bore
External work - 40mm nominal bore
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade( Size 0.45x0.60x6= 1.62
Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. Single Tee with door
110 mm bend
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe
32 mm dia
40 mm dia
Providing and fixing square mouth S.W. gully trap grade 'A' complete with C.I. Grating brick masonary chamber with bricks of class designation 75 and water tight C.I. Cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
100x100 mm size P type with common burnt clay F.P.S.(non module) brick of class designation 7.5
Constructing brick masonary road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement :4 coarse sand ) including 500x450 mm precast RCC horizontal grating with frame complete as per standard design . with common burnt clay F.P.S.(non module) brick of class designation 7.5
Supplying and fixing PVC fittings of approved make confirming to IS : 1729 including supplying nails and bobbins, fixing solutions including earth work or masonary work cutting and remaking and providilding as the case may be all complete as per specification and direction of E/I.
PVC plain bend 100mm dia.
PVC double junction with door and ear 100mm dia.
PVC cowl - 100mm dia.
Floor trap - 100mm dia.
Ring rubber
Lubricant
Door piece
Providing and fixing PTMT flange 15mm size 56mm dia suitable for 15mm taps and weighing not less than 5gms of apporved ISS make
BOORWELL
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I.
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 50 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
INNER ELECTRICAL
Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed with PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
Group-C
Power plug wiring in PVC conduit (2x4 sq.mm.):- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed Medium Class PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required.
Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper condcutor, single core cable in surface/ recessed Medium Class PVC conduit as required.
2x1.5 Sqmm + 1x1.5 sqmm earth wire
2x2.5 Sqmm + 1x2.5 sq mm earth wire
2x4.0 Sq.mm + 1x4.0 Sq.mm earth wire.
2x6.0 Sq.mm + 1x6.0 Sq.mm earth wire .
4x6.0 Sq.mm + 2x6.0 Sq.mm earth wire.
4x10 Sq.mm + 2x6.0 Sq.mm earth wire.
TV Cable in Existing Conduit:- Supplying and drawing Co-axial TV Cable RG-6,0.7mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed PVC conduit as required.
Supplying and fixing of following sizes of Med Class PVP conduit along with the accessories in surface / recess & cutting the wall and making good the same in case of recessed conduit as required . 25 mm
Supply and fixing of following size PVC/G.I. box on surface /recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
75mmx75mmx60mm deep.
S/F Modular type Switch / Socket:- Supplying and fixing of following switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requried.
5/6 amps switch
15/16 amp switch
3 pin 5/6A socket outlet
6 pin 15/16 amp socket outlet
TV antenna socket outlet
S/F Modular type electronic fan regulator:- Supplying and fixing Stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd.
S/F Modular blanking plate:- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required.
1 or 2 modules (78mmx78mmx45mm)
6 module (78mm x 205mm x 50mm)
S/F light plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.
S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
S/F Ceiling Rose:-Supplying & fixing of 2 pin, 5 amp Ceiling rose on the existing junction box/ wooden block including connection etc. as required.
S/F Batten / Angle Holder:- Supplying and fixing brass batten/angle holder including connection etc. as required.
S/F Call Bell Buzzer:-Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required.
ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of suspended pre-wired ,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., directly on ceiling or on wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
ITC fluorescent fitting with Down Rods:-Installation, testing and commissioning of suspended pre-wired ,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
ITC ceiling fan:-Installation, testing and commissioning of Ceiling fan, icluding wiring the down rods os standard length (Up to 30Cmm) with 1.5 sq. mm FR PVC insulated, copper conductors, single core cable etc. as required.
ITC exhaust fan upto 450 mm sweep:-Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
S/F TP MCB DB: -Supplying and fixing following way, horizontal type thee pole & neutral, sheet steel, MCCB distribution board, 415V, on surface/ recces , complete with tinned copper bus bar, neutral bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCCB/RCCB/Isolator) Make- Legrnd/Siemens/ L&T.
6 ways (4+18) Double Door. (horizontal type)
S/F 'C' Series MCB:-Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, 'C' curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6-32 Amps. Single Pole
6/32 Amps TPN
63 Amps TPN
S/F SP MCB Blanking Plate:- Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
S/F SPN RCCB:- Supplying & fixing following rating double pole (Single Phase & Neutral) 240 V, Resudual Curren Circuit Breaker (RCCB) , having a sensitivity current uo to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
P/F MV Danger Notice Plate:-Providing & fixing of M.V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
G.I. Pipe Earthing:- Earthing with G.I. Earth Pipe 4.5 Meter long , 40mm dia including accessories, and providing massonry enclosure with cover plate having locking arragement and watering pipe etc. with charcoal/cock and salt as required.
Copper Plate Earthing:- Earthing with copper Earth Plate 600mmx600mm x3mm thick including accessories, and providing massonry enclosure with cover plate having locking arragement and watering pipe etc. with charcoal/cock and salt as required. (For UPS)
Supplying and laying of 8 SWG G.I. copper wire at 0.50 meter below ground level for conductor earth electride, including soldering etc. as required.
S/L 25mmx5mm G.I. strip as strip earth electrode :-Supplying and laying 25 mm X 5 mm GI strip at 0.50 meter below ground/surface as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm).
Providing and fixing of Lightning Conductor finial, made of 25 mm dia 300mm ling, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Reverting, Sweating and soldering Lightning Conductor Tape:- Reverting, Sweating and soldering of Copper/G.I. Tape (with another Copper/G.I. tape, base of the finial or any other mettalic obect) as requried.
P/F G.I. lightning conductor tape in horzontal run :- Providing and fixing G.I. Tape 20mmx3mm thick on parapat or surface of the wall for lightning conductor complete as required. (for Horizontal Run).
P/F G.I. lightning conductor tape in Vertical run:- Providing and fixing G.I. Tape 20mmx3mm thick on parapat or surface of the wall for lightning conductor complete as required. (for Vertical Run).
G.I. Pipe electrode with Salt/Charcoal:- Earthing with G.I. Earth Pipe 4.5 Meter long , 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arragement and watering pipe etc. with charcoal and salt as required.
S/L 25 x 5mm G.I. earth strip in 50 mm below ground:- Supplying and laying 25mmx5mm G.I. Strip at 0.50 meter below ground as strip earth electrode, including connection/ termination with G.I. nut bolts, spring washer etcas required. (Jointing shall be done over and 2 sets of G.I. Nut Bolts & Spring washer spaced at 50mm).
Supply, installation, testing and commissioning of of following size ceiling fan 3 blades confirming to IS:- 374:2019 including wiring tne down rods, of standard length (up to 30 cm) with 1,5 FR PVC insulated, copper wire suitable for 230 Volts, 50 Hz, single phase supply etc. complete as required.( BLDC 5 Star (32 Watt) IS:374:2019 (energy efficient fans and two yeas warranty ) (Make & Model nos. of Fans are to be approved by Engineering Incharge & Consultant before procurement.)Supply of 48" (1200 mm) Sweep Ceiling fan BLDC 5 Star (32 Watt) IS:374:2019 (energy efficient fan. Make :Usha/Crompton/ Havells.
SITC of 230 mm (9") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Usha/Crompton / Havells .
SITC of 400 mm (16") sweep AC 230/250 volts, 50 HZ Wall Mounting Revolving Fan with brackets, cooper winding, etc. complete all electric room etc. Make :- Usha/Crompton / Havells .
All the LED lamp shall be of minimum 60 or above lumens per watt and the LED BATTEN TUBE LIGHTS & other LED light fixtures shall be of 100 or above lumens per watt. LM 79 and LM 80 reports need to be submitted with all accessories by the contractor. All LED Lights (Make & Model nos. of LED Liughts are to be approved by Engineering Incharge & Consultant before procurement.) Make:-Havells/Philip/Wipro/Crompton. .
SITC of following rating Street Lighting Luminarie with pressure die-cast housing and toughened glass cover, IP-66 protection, LUMINOUS EFFICARY 110/lm/w, with lens in existing pole or pipe for supply voltage, 100-270V, AC, 50Hz, luminarie shall be confirm to IS; 10322 part-5/section-3 and shall be complete with all necessary accesoreies as required. (To use as building outer light in 5ft long 40 mm G,I, Pipe with 3 nos.Clamps and nut bolts) Make:- Havells/Philips/Wipro.. 45/48 W LED Strret Light (tobe use as Building Outer Lights)
SITC of following rating surface mounted LED 4ft Batten tube light fitting suitable for 230V, 50 Hz, single phase supply etc all complete as required. wall mounted LED type batten fitting complete with electronic diver and LED etc. directly on wall including connections with 1.5 Sq. mm FR PVC insulatted copper conductor and earthing the body etc. as requiered. s requiered. Efficacy is 100 lm/W.temperature (5700K ± 355K. The Average life of 25000 burning hrs @L70 & Lumen maintenance as per L70 (Confirming to I.E.C. 62722) Make:- Havells/Philips/Crompton/Wipro. 1x 20/22 W LED Tube Light (4 FT) Batten type.
All the LED lamp shall be of minimum 60 or above lumens per watt and the LED BATTEN TUBE LIGHTS & other LED light fixtures shall be of 100 or above lumens per watt. LM 79 and LM 80 reports need to be submitted with all accessories by the contractor.Make:-Havells/Philip/Wipro. Supply of 9W/10W LED Bulb in existing holders. (Confirming to IEC : 62722) Cost of 9W/10W LED Bulb
SITC of LED 2 ft Mirror light with power 8/10W, rated voltage 230W, 50 HZ, aluminium /PC body with running life minimum 30000 hrs. Make:-Havells/Philips/Crompton/JaguarCost of LED 2 ft Mirror light with power 9/10W,
2x20W 4ft LED Batten Tube Light (Confirming to I.E.C. 62722):- SITC of double LED Tube light Fitting made of diacast aluminium housing 2x20W LED Bettle Tube light sritable for surface or suspended mounded suitable for 230V, 50 Hz, single phase supply etc all complete as required, complete with electronic diver and LED etc., including connections with 1.5 Sq. mm FR PVC insulatted copper conductor and earthing the body etc. as requiered. Efficacy is 100 lm/W.temperature (5700K ± 355K. The Average life of 50000 burning hrs @L70 & Lumen maintenance as per L70 (Confirming to I.E.C. 62722) Make:- Havells/Philips/Crompton/Jaguar.
Supplying and fixing Surface mounted 9/10 Watt CFL / LED type bulk head e comprising of pressure die casr housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc. directly on wall /ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc as required.Make:-Havells/Philips/Crompton/Jaguar.
SITC of LED 50W suspanded type industrial COB LED highbay light with aluminium die cast heat shink for T.T. Room. Make:-Havells/Philips/Crompton/Jaguar
SITC of LED 100W suspanded type industrial COB LED highbay light with aluminium die cast heat shink for Badminton room. Make:-Havells/Philips/Crompton/Jaguar
KVA ON Line UPS (Single Phase Input & Single Phase Output) With Accessories Supply, fitting, fixing, testing and installation of 1 no. 5 KVA, ON Line UPS Single phase input and single phase out put power system of in put voltage 100V/ AC +/- 5% to 300V AC +/- 5% , Frequency range 40 HZ to 60 Hz, +/- 10% and out put voltage range 415V +/-1%, AC frequency range, 50Hz, +/-1% poower factor>_ 0.90 @ Full Load, 0,8/3.1, Harmonic distrortion -< 2% THD (Linear Load): 5% THD (Non- Liniear Load) along with required Batteries, Battery Stand, UPS Box Battery Lead etc as required. (minimum 30 minutes back up )Make UPS:- Numeric (Legrand), APC (Schneider), Vertive(Emersion) Cost of 1 no. 5 KVA ON LINE Single Phase in and Single Phase out UPS SITC of 1 no. TROLLY Fof double Tubular Battery SITC of 2 no. 12v/150Ah Sealed Maintance free (SMF) battery with 24 months replacement Gurantee, IS1652:1991) . Make:- Battery-Exide, Amar-Raja, Quantum. Total cost of 1 Set 5 KVA UPS, Batteries & Accessories (A+B+C) (Single Phase inand Single Phase Out)
SPLIT AC AND VOLTAGE STABILIZERSITC of 1.5 Ton 5 Star High wall Split AC Inverter Type IS:1391, Part-1 or Part-11(Hot and Cold) Unit of BEE Rating, (Generally conforming to IS 1391 latest) Inverter (Variable Speed), Heating Mechanism-Electric Heater, Minimum SetTemperature-12 degree Celsius, Maximum SetTemperature-40 degree Celsius, Remote Control, with original company make out door structure including rigging of indoor out door units, pressure testing vacuumingising etc as required. Make:- Blue Star/Hitachi /Carrier. (CATEGORY A or B)
SITC of 2 Ton 5 Star High wall Split AC Inverter Type IS:1391, Part-1 or Part-11 (Hot and Cold) Unit of BEE Rating, (Generally conforming to IS 1391 latest) Inverter (Variable Speed), Heating Mechanism-Electric Heater, Minimum SetTemperature-12 degree Celsius, Maximum SetTemperature-40 degree Celsius, Remote Control, with original company make out door structure including rigging of indoor out door units, pressure testing vacuumingising etc as required. Make:- Blue Star/Hitachi /Carrier/Mitsubishi. (CATEGORY A or B)
SITC of wall mount suitable capacity (4 KVA) Automatic Voltage Stabilizer, voltage range 140V to 280V of copper wound Transformer along with suitable size of connectors. (in & out) Make:- Sen & Pandit/V Guard/ Blue Star
Supply, fitting, fixing of wall mount suitable capacity (5 KVA) Automatic Voltage Stabilizer, voltage range 140V to 280V of copper wound Transformer along with suitable size of connectors in & out. Make:- Sen & Pandit/V Guard/ Blue Star
AC Accessories SITC of Copper Tube of Size 1/4" for Split AC Unit 1/1.5/2/3 Tr Capacity including nitide rubber insulation.
SITC of Copper Tube of Size 1/2" for Split AC Unit 1/1.5/2/3 Tr Capacity including nitide rubber insulation.
SITC of UPVC Drain Pipe for Split AC Unit
SITC of Outdoor Stand for 1.5 Tr Split AC Unit
SITC of Outdoor Stand for 2.0 Tr Split AC Unit
SITC of FR PVC Insulated 3C, 4 Sq. mm Copper Wire.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (23AWG Cable) Make- Legrand-,Schneider- Actasis, Optronix 1 run of Cable
Gem Items FOR SURVEILLANCE (CCTV SYSTEM) (PART-C)
SITC of 2 MP indoor Bullet Varifocal IP (IR) camera (2.8-12mm Lens) (Matrix), Day Night Type, -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps,2.7 to 13.5 mm lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), Alarm: 2 inputs & 2 outputs, Audio: 1 input & 1 output, IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Scene change detection,Motion detection, Face detection, Audio exception detection, Video tampering, UL, FCC, CE certified. Make- Axis/Hikvision/Pelco/Honeywell or as appoved by Architect/ Consultant.
SITC of 2MP IR Bullet Fixed Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. Make- Axis/Hikvision/Pelco or as appoved by Architect/Consultant.
Installation, Testing and Supplying, Commissioning of 8 TB SEAGATE Windows Surveillance Hard Disk SEAGATE (ST8000VX004) Availability: 1000 In Stock Min. Qty. Per Consignee:1Capacity (TB) :8 terabyteWorkload Rating (TB/year) :550R in the NVR/ DVR complete with suitable SATA Cable/ Power Connectors complete as per specifications attached etc. as reqd.
SITC of Surveillance class SanDisk 128 GB Memory Card SanDisk 128GB for camera. Type of memory Card SD HCT,Storage Capacity (GB):128,Insertion /Removable Durability 25000 (Number or Times) Maxim. ReadSpeed(MB/S)Upto100Maxim. Write Speed (MB/Sec) Upto 100, Interface Express Card/34 (SanDisk 128GB Ultra SDXC UHS-IMemory Card - 100MB/s, C10, U1, FullHD, SD Card) Make- Hikvision/Honeywell/Pelco/ or as appoved by Consultant.
SITC of 43" LCD 24X7 Surveillance Monitor ((SMART TV). Make-LG/Samsung or as appoved by Architect/Consultant. Make:- Sony, LG, Panasonic
9 U WALL MOUNT EQUIPMENT RACKSITC of of 9U Wall Mounted Equipment Rack PDU Power Strips Available. (Make : Make : Legrand-VALRACK/ Netrack/Rittal/Schneider/Ortronics or as approved by architect).
T,V. Set SITC of 55" Full HD 1080p LED TV.; FIRSTOUCH Smart Television Tv 55Inch LED Backlit LCD ,Resolution (Pixels)- (3840x2160) UHD, Screen size- 55" , Smart TV, Details of accessories(included in the scope ofsupply) :-Remote Control,Connecting Cable,Batteries, Dimensions (Length xBreadth x Depth) 52” x 1.2” x 31.4. Wall Mount. Power Consumption-138 Watt. Wifi Direct, Built in Wifi. Make-Soni/LG,/Samsung/ Panasonic.
RO WATER PURIFICATION SYSTEMSupply , fitting fixing and commissioning of INDIAN WATER INC. PURE WATERFOR LIFE Fully automatic with autocut off RO Potable WaterPuri 2000 Plus 25 Litre RO+UV+UF Water Purifier Electrically oparated • Purification Technology RO+UV+UF• Capacity 25 Litre • Filter - Pre-filter (optional), sediment filter, activated carbon filter, anti-scalant filter, post-UF filter, • Membrane Type 80 GPD,• Power Features- • Power Requirement- 110V - 300V, 50 Hz, • Operating Voltage - 24V DC V along with all required accessories, like, connecting wires, pipes, stand and fixing euipments along with drain Pipe in put pipe and etc as required. Make- Aquagard, Voltas, Kent.
Cost of Water Purifire INDIAN WATER INC. PURE WATERFOR LIFE 2000 Plus 25 Litre RO+UV+UF Water Purifier Electrically oparated • Purification TechnologyRO+UV+UF• Capacity 25 Litre •
Supply, erection, testing and commissioning of splitter / tap off mounted in suitable sizes MS boxes for MATV system and shall be suitable for interactive system. Make- Reputed (as directed by Consultant)
Two Way (S-2)
Two way tap off (T2)
SITC of 8 port Unmanaged Network PoE Switch: , Unmanaged, 8 100M PoE port, 1 100M uplink port, 802.3af/at, PoE power budget 123W Make:- Cisco /Allied Telesis/ HP-Aruba/ Juniper or as approved by Architect.
SITC of 24 port Unmanaged Network PoE Switch: , Unmanaged, 24 100M PoE port, 1 100M uplink port, 802.3af/at, PoE power budget 310W Make:- Cisco /Allied Telesis/ HP-Aruba/ Juniper or as approved by Architect.
EXTERNAL ELECTRICAL
Point Wiring in PVC Conduit, with Modular type Switch:-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed with PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
Group-C
Power plug wiring in PVC conduit (2x4 sq.mm.):-Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed Medium Class PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required.
Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper condcutor, single core cable in surface/ recessed Medium Class PVC conduit as required.
2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire (for Single Separate 6A) (Circuit shall be taken from nearest switch board)
2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire. (for switch board circuit).
2 X 6.0 sq. mm +1 X 6.0 sq.mm earth wire.
Supplying and fixing of following switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd.
5/6 amps switch
15/16 amp switch
3 pin 5/6A socket outlet
6 pin 15/16 amp socket outlet
S/F Modular type electronic fan regulator:- Supplying and fixing Stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd.
S/F Modular blanking plate:- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required. 1or 2 module (78mmx 78mmx 45mm)
Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required. 6 module (78mmx 205mmx 50mm) (for 2 nos. 6A Sockets & 2no. 6A Switch)
S/F Light plug point with modular type accessoris:-Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular type switch, connections painting etc. as reqd. (for Light plug point).
S/F Power plug ponit with modular type accessories:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular type switch, connections painting etc. as requried.
S/F Ceiling Rose:- Supplying & fixing of 2 pin, 5 amp Ceiling rose on the existing junction box/ wooden block including connection etc. as required.
S/F Batten / Angle Holder:- Supplying and fixing brass batten/angle holder including connection etc. as required.
ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of suspended pre-wired ,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., directly on ceiling or on wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
ITC ceiling fan:- Installation, testing and commissioning of Ceiling fan, icluding wiring the down rods os standard length (Up to 30Cmm) with 1.5 sq. mm FR PVC insulated, copper conductors, single core cable etc. as required.
ITC exhaust fan upto 450 mm sweep:- Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
S/F SP MCB DB:- Supplying and fixing following way, SP&N MCB distribution board of sheet steel for 240 Volts on surface /recess complete with tinned copper bus bar, neutral busbar, earth bar, detachable gland plate, interconnections, phophatized and powder coated painted including earthing etc. as required ( But without MCB/RCCB/ISOLATOR).
8 Way Double Door
S/F 'C' Series MCB:- Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, 'C' curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Double Pole
S/F 20 amps SPN MCB industrial socket outlet:- Supplying and fixing of 20 Amps, 240 Volts, SPN Industrial type, socket out lets, with 2 pole and earth, metal enclosed plug top alongwith 20 Amps."C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket 0ut let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 20 Amps, 415 Volts, TPN Industrial type, socket out lets, with 4 pole and earth, metal enclosed plug top alongwith 20 Amps."C" curve, TPN MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket 0ut let and complete with connections, testing and commissioning etc. as required.
P/F M. V. danger notice plate :- Providing & fixing of M.V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
P/F H.T. danger notice plate:- Providing & fixing of H.T. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Earthing with G.I. Earth Pipe 4.5 Meter long , 40mm dia including accessories, and providing massonry enclosure with cover plate having locking arragement and watering pipe etc. with charcoal/cock and salt as required. Transformer- 2 nos. Earth Pits & 2 Nos. 2 Neutral pits- 4 nos. Main LT Panel- 2 nos. Total - 6 nos.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground/surface as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
LV/MV Cable Laying of 1.1 KV:- MV Cable Laying up to 35 sq. mm. in ground :- Laying of one number PVC insulated and PVC seathed /XLPE power cable of 1.1 KV grade of size not exceeding 35 Sq. mm direct in ground including excavation, sand cushaning, protective covering and refilling the trench etc. as required
MV Cable Laying up to 95 sq. mm. in ground :- Laying of one number PVC insulated and PVC seathed /XLPE power cable of 1.1 KV grade of size exceeding 35 Sq. mm but not exceeding 95 sq.mm direct in ground including excavation, sand cushaning, protective covering and refilling the trench etc. as required
MV Cable Laying up to 185 sq. mm. in ground :- Laying of one number PVC insulated and PVC seathed /XLPE power cable of 1.1 KV grade of size exceeding 95 Sq. mm but not exceeding 185 sq.mm direct in ground including excavation, sand cushaning, protective covering and refilling the trench etc. as required.
11 KV HV CABLE LAYING:- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of grade of size exceeding 1.1 KV but not exceeding 11 KV of size not exceeding 120 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
CABLE ROUTE MARKER:- Supplying and making cable route marker with cement concrete 1:2:4 (1 Cement :2 Coarse sand ;4 gradced stone aggregate 20mm nominal size ) of size 60cmx60cm at the bottom and 50cmx 50cm at the top with a thickness of 10 cm including inscription duly engraved as required.
PVC/XLPE indulated PVC sheathed heavy duty, aluminium armoured cable of grade 1.1KV:- Providing and fixing of PVC/XLPE indulated PVC sheathed heavy duty, aluminium armoured cable of grade 1.1KV as per IS:7098 (Part-1), etc. as required. Make:- Havells / Finolex / Polycab/ KEI.
2 Core 6 Sq. mm XLPE Al. Ar. Cable 1.1kV.
3.5 Core 150 Sq.mm. XLPE Al. Ar. Cable 1.1kV.
4 Core 10 Sq. mm XLPE Al. Ar. Cable 1.1kV.
FANS & EXHAUST FANS:- Supply, installation, testing and commissioning of of following size ceiling fan 3 blades confirming to IS:- 374:2019 including wiring tne down rods, of standard length (up to 30 cm) with 1,5 FR PVC insulated, copper wire suitable for 230 Volts, 50 Hz, single phase supply etc. complete as required.( BLDC 5 Star (32 Watt) IS:374:2019 (energy efficient fans and two yeas warranty )
Supply of 48" (1200 mm) Sweep Ceiling fan BLDC 5 Star (32 Watt) IS:374:2019 (energy efficient fan. Make :Usha/Crompton/ Havells.
SITC of 230 mm (9") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Usha/Crompton / Havells .
SITC of 400 mm (16") sweep AC 230/250 volts, 50 HZ Wall Mounting Revolving Fan with brackets, cooper winding, etc. complete all electric room etc. Make :- Usha/Crompton / Havells .
LED LIGHT FIXTURES (JSR 2021 -Rates) CORRIGENDUM:- S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, Single phase supply rtc. Complete as required.
Supply of 1x 20/22 surface mounted LED 4ft Batten tube light fitting suitable for 230V, 50 Hz, single phase supply etc all complete as required. wall mounted 20/22 watt (4ft Long) LED type batten fitting complete with electronic diver and LED etc. directly on wall including connections with 1.5 Sq. mm FR PVC insulatted copper conductor and earthing the body etc. as requiered. s requiered. Efficacy is 100 lm/W.temperature (5700K ± 355K. The Average life of 25000 burning hrs @L70 & Lumen maintenance as per L70 (Confirming to I.E.C. 62722)Make:- Havells/Philips/Crompton/Wipro.
SITC of following rating Street Lighting Luminarie with pressure die-cast housing and toughened glass cover, IP-66 protection, LUMINOUS EFFICARY 110/lm/w, with lens in existing pole or pipe for supply voltage, 100-270V, AC, 50Hz, luminarie shall be confirm to IS; 10322 part-5/section-3 and shall be complete with all necessary accesoreies as required.Make:- Havells/Philips/Wipro..
45/48 W LED Strret Light. (Campus Light)
SITC of following rating LED post of Lampmade in die cast Alluminium housing with decorative Clear/Opel acrylic diffuser on existing pipe including connection with 1.5 Sq.mm FR PVCcopper conductor in existing PVC pipe etc. all complete as required.
40/45 Watt LED POST OF LAMP CLEAR
All the LED lamp shall be of minimum 60 or above lumens per watt and the LED BATTEN TUBE LIGHTS & other LED light fixtures shall be of 100 or above lumens per watt. LM 79 and LM 80 reports need to be submitted with all accessories by the contractor.Make:-Havells/Philip/Wipro. Supply of 9W/10W LED Bulb in existing holders. (Confirming to IEC : 62722) Cost of 9W/10W LED Bulb
Supplying and fixing Surface mounted 9/10 Watt CFL / LED type bulk head e comprising of pressure die casr housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc. directly on wall /ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc as required.Make:-Havells/Philips/Crompton/Jaguar.
100 KVA, 11/0.433KV OUT DOOR TRANSFORMER OCTC (OFF LOAD TAP CHANGER) (-12.5% to +2.5% in step of 2.5 %)
Supply, installation, testing, fixing and commissioning in correct alignment position, effecting proper connections of continuous rating of 100 KVA, 3Ph, 50Cy, 11/0.433KV, Off Circuit, (OCTC) oil cooled, copper wound, (-12.5% to +2.5% in step of 2.5 %) Outdoor Transformer, at full load and temp. rise not exceeding 45 degree C, by Thermometer in oil and 50 Degree C. by the resistance in winding after continuous run in full load rating. The Transformer should oil immersed winding having Vector DY-11 HT side connected in Delta, & LT Side connected in Star with neutral brought out connected to provide separate earthing. In Transformer HT Side Bushing/Cable End Box, & LT side - Cable End Box. Transformer shall be latest manufacturing standards as per amended IS Specifications and load and no load losses shall be limited to the values given below as per IS or Norms issued by JVVNL or which ever is lower. The transformer, length of MS channels as per the norms of 100 KVA Outdoor Transformer with all accessories, air filled cable box and accessories as per General Specifications of 100KVA out Door Transformer and should have suitable for 11KV 1 Run, 3 Core 35 Sq mm XLPE Al. Ar. Cable and LV termination box shall have suitable arrangement for 1.1 KV, 1 Run, 3.5 Core, 150 Sq. mm XLPE Al. Ar. Cable etc as required. The copper loss and Iron loss shall be as per the Level 2 rating out Door Transformer. (Make:- Power Star/True Volt/ Synergy/Voltamp Transformers Ltd, Barodara/Kiriloskar Elec. Co. Ltd, Arnav Power Tech.) 1 Oil Conservator with filling hole with Cap and plain oil level gauge 2. Silica gel dehydrating breather charged with silica gel 3. Oil drain valve 4. Oil filter valve 5. Lifting eyes hooks 6. Two Earthing terminals 7. Diagram and rating plate 8. Air vent 9. Explosion vent 10. 100mm dia thermo meter with thermometer pocket 11. Four bi directional plain roller. 12. 100KVA (No Load loss 850W and load loss 5800)
Total Cost of 100 KVA 11/0.433KV (OCTC) Outdoor Tansformer.
25 KVA 3 PH, Liquid Cooled Silent D.G. Set confirming to CPCB-II Norms with AMF Panel IS/IEC-60034-1 IS:-1460 IS :-13018 Supply, installation, fixing, commissioning and testing of 25KVA D.G. Set, 415 Volts, 3 Ph. Liquid Cooled Silent Diesel Generator Set (manual control) confirming to IS:1460/ AC supply complete with engine (1500 RPM) and alternator DG Set controller confiring to IS:13018 with accessories including residential type silencer and fuel service tank 75 litres capacity, battery, battery leads, battery charger with all accessories, including MCCB of suitable rating & standard set of tools and anti-vibration mounting pads, etc. The power command controller compactable with BMS, PC & PLC compelte as required, remote mointoring and data logging with digital voltage regulator through inbuilt AVR, digital governing including protection complete as required. Rate shall be inclusive of all items required for D.G. Sets exhaust system including M.S. pipes, insulation, M.S. structure & accessories etc. and shall be compiled to ECBC-2007 norms, along with the following accessories. Make of DG Set :- (KOHLER, Jackson, KOEL- GREEN, Sterling Wison, (Perkins).
Supply of acoustic enclosure for 25 KVA CPCB approved Acoustic enclosure with 80 mm MS base plate, 2 mm CRCA sheet, 50 mm thick foam / 100 mm Rock Wool Insulation, 14 surface tank treatment, dully powder coated and painted with Briliant Blue colour with integrate Fuel Tank, services door, louvers (Fresh Air / Radiator), 1020 dia residential type Silencer, approx dimension L x W x H - as per norms. Complete with following accessories :- Note:- The above 25 KVA Silent DG set costing is not inclusive of construction of 150 mm thick 8' X 4' RCC foundation as DG Platform.
Diesel Engine
The DG set comprises of Engine model For 25 KVA (3R1040T G1) Developing 42 BHP at 1500 RPM complying with the requirements BS5514/ IS 10002, directly coupled to a AC generator capable of developing 25 KVA at 415 v 50Hz, 0.8 pf (lag) generally meeting the requirements of Bs 5000. a power control panel to regulate the AC power is also provided capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. . The DG set will be complete with the following
v Fuel tank for 8 hrs.Operation.
AC GENERATOR
v Single bearing, self-excited, self regulated in brush lessconstruction.
v Automatic VoltageRegulator
v Class H insulation for Stator & RotorWinding.
DG POWER CONTROL PANEL (Microprocessor Based)
v Microprocessor based fullyconfigured
v Graphical bigger LCDdisplay
v Best in class monitoring anddiagnostic
v AC Volt LCDdisplay
v ACAmp.LCDdisplay
v DCAmp.LCDdisplay
v KW LCDdisplay
v Frequency LCDdisplay
v Low Fuel Levelindicator
v Routine Maintenanceindicator
v Moulded Case Circuit Breaker for ShortCircuit&OverloadProtection OR MiniatureCircuitBreaker
v Aluminiumbusbarsofadequaterating.
v Provision for bottom entry & exit of power cabling.
v Set Of Current Transformers.
v Set Of Control Fuses
TECHNICAL SPECIFICATION OF KOEL iGREEN ACOUSTIC ENCLOSURE CONSTRUCTION
Following are some technical features of Acoustic Enclosure:-
1. The enclosure is modular inconstruction
2. Base frame is made of Sheetmetal.
3. Durable industrial locking system is provided ondoors.
4. Doors are gasketed with high quality EDPNgasket.
CORROSION RESISTANCE:
To make the enclosure weather proof: -
1. All sheet metal parts/components are hot dipped in seven tanks process, pretreated and passivated.
2. Sheet metal components are painted with P.P basepower.
3. Base frame is epoxycoated.
4. Zinc passivated hardware is used to avoidrusting
ACOUSTIC INSULATION:
1. Sound proofing of the enclosure done with quality Foam confirming to IS:8183.
2. Acoustic form shall be fire retarded and fireresistant.
3. Attenuates are provided to control sound at entry and exit to and from thecontainer.
4. Specially designed Residential Silencer isprovided.
VENTILATION AND AIR CIRCULATION:
Exhaust pipe is thoroughly insulated by covering it with glass wool and further cladded in Enclosure.
SAFETIES:
Emergency push button to stop the DG set from outside, Lub oil level, Lub oil pressure, Fuel level indicator, coolant level, Canopy temperature, High engine temperature
In above supply item following work are included by supplier :- i) Installation, fitting, fixing, testing and commissioning of the same. ii) Civil part like RCC foundation for commissioning of D.G. Set (NOT INLUDED) iii) Installation of Exhaust system for D.G. Set shall be as per Central & State Pollution Board Norms along (C.P.C.B.). iv) Test run for D.G. Set without load and with load (part wise ) at least 1 hrs each time , in load also total 1 hrs. (in 50% load and 1 hr. in 100% Load-and 1 hr. in 110 % load.) Total 3 hrs. each)
Total Cost of 25 KVA SILENT DG SET WITH AMF PANEL
Supply of 7 Meter Height Octagonal Hot Dip Galvanized pole (BOP 7030) with top dia 70mm bottom dia 130mm & made of 3 mm thickj sheet, base plate dimensions 200x200x12mm (L X B X T) including suitable sizes of foundation bolts all complete as required. (Without ARM) Make:- RR Ispat/ Transrail/ Valmount/Bajaj.
Installation, Testing and commissioning of 7 Meter Height Octagonal Hot Dip Galvanized pole with suitable Tools and Plants, wiring of Luminaires with all materials and construction of shallow foundation, with M25 grade concrete considering safe soil bearing of 10T/mtrs Sq.
Supply fitting, fixing of Single Arm (1 Mtr. Long) suitable for 70 mm Top.
Supply fitting, fixing of Double Arm (2 Mtr. Long)suitable for 70 mm Top
HT CABLE LAYING:- Laying of one number additional PVC insulated and PVC seathed /XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushaning, protective covering and refilling the trench etc. as required up to 120 Sq. mm and up tp 400 sq. mm
1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required.
2 Core 6 Sq. mm. (19mm)
3.5 Core 150 Sq. mm. (50mm)
4 Core 10 Sq. mm. (25mm)
Supplying and making out door cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE aluminium conductor cable of 11 KV grade as required.
35 to 70 Sq.mm.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required
50 mm dia
80 mm dia
100 mm dia
Supplying and fixing of 30 Amps, 415 Volts, TPN Industrial type, socket out lets, with 4 pole and earth, metal enclosed plug top alongwith 30 Amps."C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket 0ut let and complete with connections, testing and commissioning etc. as required.
Supplying, designing, manufacturing, installation, shifting in location, testing and commissioning in correct alignment position, effecting proper connection of all incomer and outgoing feeders of Floor Main Panel dust, damp and vermin proof (IP-42) free floor standing / wall mounted factory built sheet steel enclosed modular construction extendable MAIN LT PANEL, suitable for operatrion on 415 + 10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted (powder coated) complete with aluminium bus bars, interconnection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required.
The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with at least 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry with suitable size base channel and minimum 300 mm Gap from floor for cable entry of incomer Feeder,.
The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A MCB's to be used.
The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm.
The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, multifuction meter, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket.
The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type.
AL. BUS BAR:- The panel includes 415V, 200A, 3Ph, 25kA, 50Hz Electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082. The current density of Aluminum shall not be more than 0.8 Amps/sq.mm cross sectional area of Bus Bar. Aluminiu Bus bar shall be with removable glands plates, cable glands and sending and receiving ends, including connection with outgoing feeders complete in all respects. The support for busbar shall be nonhygroscopic non inflammable epoxy cast resin insulators. The minimum clearance between live part shall be 35-40mm. The Aluminium bus bar shall be with heat shrinkable PVC Slived Red,Yellow,Blue & Black as (RYB & N ) after temperature and incloser derating maximum allowable temp.of bus bar shall be 90 degree C. Feeders to bus Bar interconnections shall be with minimum 1.5/2.5/4/6 sq.mm. FRLS copper wires. Each feeder shall have individual compartment with name plate.
Panel Size - As per Drawing submitted by panel builder..
1 Set Of Fabrication part of LT Panel & busbar system, wiring with FRLS CU Wires, in CRCA Sheet Steel enclosure (IP-43) without any components & its busbar system, in CRCA Sheet Steel enclosure without any components. Name of Panel Builder :-:- EAP- Kolkata / AC Power, kolkata, /Mirco Cosmic Engineering, Patna / Shivalic PowerControl Pvt. Ltd, / Meditron, Meshra, Ranchi
Make of MCCB - L&T D-Sine / Legrand DPX³ / Schneider-NSX / Siemens - 3VL-or 3 VA /ABB T-max
Make of MCB- C Series 10kA- Legrand- DX³/Schneider- ACTI-9/ Siemens- Beta Guard/ L&T- AU VERSION. (Icu=15kA as per Iec 60947-2, Impulse withstand 6KVp, Pollution degree 3, Energy limiting Class 3)
INDICATING
1 Sets Multifunction Meter having LED display accuracy Class 1 as per IEC 62053-21, RS-485 port,(Ethernet/ Modbus ready suitable for monitoring and control with BMS System) in built RTC, Aux Supply: 44-277Vac/dc. Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, Onhrs Interrupts, THD for V&I per phase, Make-Schneider/ Satec/ Rishav/L&T . 3 nos. CT of different power as per incomer & out going /5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:-Kappa / Matrix 3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer & outgoing.Make-L& T/ AE/ Schneider.
INCOMER
1 No. 250A F/P MCCB (25kA) with adjustable thermomagnetc release type with S/C & O/L protection, with extended front rotary handle and spreader links. (Incoming cable size –1 Run 50 Sq mm 3.5 Core Al. Ar. Cable).
OUT- GOING With without DG
6 nos. 63A/FP/25KA/ MCCB with adjustable thermomagnetc release type with S/C & O/L protection, with front rotary handle and spreader links. 2 nos. 32 A DP MCB C Series 10 kA
INTERLOCKING
Provision of Mechnical interlocking between 1 No. 125A/FP/ 25kA, MCCB & 125 A TPN On Load Change Over for power supply & D.G supply, in such a way so that the two supplies are not parallel at any time. Fidder with DG sports 1 no. 125A/FP/25KA/ MCCB with adjustable thermomagnetc release type with S/C & O/L protection, with front rotary handle and spreader links.
1 No. 125 A TPN on Load Change over panelmounted , open execution type Make:- L & T, Socomo, 6 nos. 25A/FP/25KA/ MCCB with adjustable thermomagnetc release type with S/C & O/L protection, with front rotary handle and spreader links. 2 nos. 32 A DP MCB C Series 10 kA
Total Cost of Main LT Panel
Providing and laying of mat made of elastomeric polymers Material (Class-B) one mtr. wide and 2.5 mm thick to withstand 15 KV dielectric strength .
1000 mm x 600 mm x 12 mm thick chequered Rubber Matting of tested quality to with stand 15KV dielectric strenght as per IS:5424
Supply of 440V grade Rubber Hands Gloves. As per IS:4770.
Supply of tool kit with 1 pair 11 KV rubber hand gloves of approved make, as per IS:4770.
Supply of First Aid Box with all necessary materials and medicine as approved by Indian Red Cross / St. John's conforming to IS:2217.
Supply and fixing of Shock Treatment Chart with glass in Aluminium frame and to be fixed on wall in Hindi and English.
Supply and fixing position the approved single line diagram framed in 1000 x 800 mm size glass frame and installed in main switch room.
Fire Extinguisher:-Supplying, commissioning and fixing of Carbon dioxide (Co2) type fire extinguisher of 4.5 Kg. Capacity duly charged confirming to IS: 2828. Make:- Minimax,Real value/Firex/Deflame.
Supplying and Fixing 3 Nos. 9 Ltr capacity G.I. buckets duly painted white inside and red oxide paint out side and written 'FIRE' with white paint and filled with dry sand and mounted on MS angle iron bracket of size 50x50x6mm thick and 1200mm long including grouting in wall/floor etc. as required confirming to IS:2546-1974.
Providing, fitting, fixing, fabricating, erecting of MS angle of section 50 mm x 50 mm x 6 mm size for PCC trench to make support for MS iron plate to be fixed on every after 300 mm in PCC trench.
Providing, fitting, fixing, fabricating, erecting of MS Plate of 12 mm thick for covering PCC cable trench of size 600 mm (L) x 800 mm (W)
Supply of following size of 11KV XLPE / PVC Insulated / PVC sheathed (Heavy Duty) armoured electric cable with aluminium conductor as per IS 7098 (Part-2) 2011 with upto date Amendments. Make:- Havells / Finolex /Gloster.
Supply of 3 Core 50 Sq. mm. XLPE PVC Al. / Ar. Cable 6.6 11 KV
FIRE FIGTHING
Supply, Installation, Testing and Commissioning of electric driven, horizontal type, single/multistage, end suction type, centrifugal pump of cast iron body, C.I impallers with carbon steel shaft & mechanical seal directely coupled with TEFC SQ cage foot mounted type induction motors suiitable for operation on 3 phase, 415 volts 50 Hz AC supply having flow rate of min 450 LPM and head of approx 40 mtrs complete in all respect as required or as directed by engineer incharge.
Terrace Booster Pump
Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 V, 3 phase 50 HZ AC supply with enclosure protection class IP 42.
For Terrace Pump
Supply and fixing of PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes including making end termination with compression gland & bimetalic lugs, and support etc.complete as required 3 × 10 sq.mm.(aluminium)
Providing and fixing IS marked Gate Valve / Foot Valve (incase of -ve suction) complete with companion flanges, bolts, nuts, rubber insetions etc 100 mm diameter
Providing and fixing IS marked butterfly valve (PN 1.6) complete with companion flanges, bolts, nuts, rubber insetions etc. 80 mm diameter
100 mm diameter
Providing and fixing check valve (NRV) complete with companion flanges, bolts, nuts, rubber insetions etc.
80 mm diameter
100 mm diameter
Pressure Gauge Assemble with Gate/Ball Valve
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Air release Valve / Drain Valve
Providing, laying, testing & commissioning of IS 1239 marked black M.S pipe including all fittings i.e bend, elbows, tees, flanges, reducing socket, nuts and bolts, gaskets etc fixed with welded / screwed joints. including necessary excavation, backfilling, removal of surplus soil etc. min. 1 mtr deep excavation and wrapping with anticorrosive treatement with 4 mm thick asphalt tape as per IS:10221, refilling the trench etc. OR fixed with screwed or welded joints, hanged with clamps, hanger supports, dash fasteners, bolts, nuts, rubber insertions etc including threading, cutting, welding, edge preparation, painting of approved colour over two coat of primer, cutting & making good the wall/ floor wherever required, complete as required or as directed by engineer incharge. Make:Tata/Nezone/Jindal
100 mm diameter
80 mm diameter
25 mm diameter
Providing and fixing S.S Fire Hydrant Valve of approved quality with 63 mm female, instant, ovlique, single outlet, 80 mm flanged inlet, brass spindle, cast iron wheel m A.B.S. blank cap and chain. conforming to IS: 5290 complete with companion flange, bolts, nuts, rubber insertion / compressed asbestos gasket etc. and painted in fire red colour.
Providing and fixing swinging, wall mounting type First Aid Hose Reel of approved quality and made from compresed steel sheet with dust cover, cast iron brackets including 30 m long, 19 mm nominal bore, high presure braided rubber hose as per IS:444 Type hose guide, PVC shut off nozzle with 6 mm outlet and 25 mm nominal bore gun metal inlet valve, bolts, nuts rubber insetion etc. painted in Fire red colour including cutting and making good the walls wherver required.
Providing and fixing 25 mm nominal gun metal gate valve class I with CI wheel of approved quality with union (Screwed end)
Providing and fixing in position 63 mm nominal bore and 15 m long synthetic fibre, CP fire hose pipe of approved make bearing IS: 636 -1988 type A mark and having TAC and MMD approved with a pair of 63 x 63 mm gun metal instantaneous type, heavy duty delivery hose coupling (conforming to IS: 903) bound and riveted to the hose pipe with copper rivets and copper wire complete.
Providing and fixing in position short SS brach pipe of approved quality with 63 mm male instatneous type inlet and 15 mm outlet nozzle complete conforming to IS : 903
Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect.
Supplying, fixing, testing & commissioning of 1 set of 63mm two way instantaneous fire brigade connection (FBC) with inbuilt NRV comprising of SS and four SS instantaneous male inlet coupling confirming to IS:604 with plug and cap with chain as required with nut & bolts, washers, high pressure gasket as required.
Providing , fixing Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 20oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (4 Kg Capacity)
Carbon Di-oxide Type , Gas Confirming to IS ‘15222’ , Cylinder Confirming to ‘IS 7285’ & PESO approved ,Controllable Discharge Mechanism, Discharge Hose & Horn As per ‘IS 15683’ & ‘IS 2878’ ISI mark Fire Extinguishers (Wheel Type or Squeeze Grip Type). Operating Temperature :- (-)20oC to (+)55oC Suitable for ‘B’ ‘C’ Class of FIRE (4.5 Kg Capacity)
Providing , fixing Modular type Fire Extinguishers for electrical rooms (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 10oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (5 Kg Capacity)
Supplying, installation, testing and commissioning of optical type Smoke detector and mounting base with LED light complete as required. Make:Qutak/Honeywell/Seimens/Bosch
Supplying, installation, testing and commissioning of duel tone electronic hooter / Flasher / Strobe suitable for wall mounted complete as required. Make:Honeywell/Seimens/ Qutak/ Bosch
Supplying, installation, testing and commissioning of manual call box in suitable enclosure with arrangement to raise the alarm when the glass is manually broken complete as required. Make:Honeywell/Seimens/Qutak/Bosch
Supplying, installation, testing and commissioning of microprocess base main fire alarm control panel with LCD Display lights. The panels shall have 240 volts AC power supply automatic Battery charger 24 Volts sealed lead acid maintenance free battries as complete with batteries, battery charger illuminated numeric digram complete as required. Make:Honeywell/ Seimens/ Qutak/ Bosch
Providing and laying 19mm dia PVC conduit complete with required junction boxes in recessed / surface system PVC insulated copper conductor cable of 2x1.5 sq.mm. in existing conduit as required. Make:Polycab/Mescab
Land Scaping
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm Qty same as in 23.3 Item
Rough dressing the trenched ground including breaking clods. 105
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. 105
Fine dressing of the Ground. 105
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).
Qty as per item No. 23.2
Qty as per item No. 23.3
Qty as per item No. 23.4.2
Qty as per item No. 23.4.2
Mixing earth and sludge or manure in the required proportion specified or directed by the officer-in-charge.
Qty as per item 23.8
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm. efilling the excavated earth after breadking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, with in a lead of 50m lift up to 1.5 m complete (cost of sludge, manure of extra earth to be paid for separately). Around Outer & Inner Length of Bondary Wall
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately): Holes 1.2 m dia and 1.2 m deep.
40% @ 4190 Holes 90 cm dia, and 90 cm deep.
Providing and fixing M. S. tree guard 45 cm square in plan, height 1.20 metre above ground level and 0.40 metre below ground level. The vertical members shall consist of four nos angle iron of size 25x25x3 mm, 1.8 m long, one at each corner and 8 nos flat iron of size 25x3 mm, 1.2 m long. The vertical mambers shall be welded to 4 nos 25x6 mm M. S. flats placed horizontally around the vertical name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer, complete in all respect.
Azadirachta indicia ( Neem ) height 120-130cm in big polybag size 25 cm
Cassia fistula (Amaltash) height 120-135 cm. in big poly bag size 25 cm
Polyalthia longifolia (Ashok) height 150-165 cm. in earthen pot size 25 cm
Polyalthia longifolia (Ashok) height 180-195 cm. in gunny bag size 30 cm
Polyalthia pendula (Ashok Pendula) height 150-165 cm. in earthen pot size 25 cm
Schleichera trijuga (Kusum) height 150-165 cm. in big poly bag size 25 cm
Eugenia jambolana (Jamun) height 150-165 cm. in big poly bag size 25 cm
Providing Plant Dahlia single in different colour with fresh & healthy foliage well developed with 6 to 8 half blooming buds in 20 cm Earthen Pot/Plastic Pot.
Providing Plant Daisy well developed with fresh & healthy foliage in full bloom in 20 cm Earthen Pot/Plastic Pot.
Providing Plant Petunia hybrid different variety in different colour well developed with fresh and healthy foliage in full bloom in 25 cm Earthen Pot/Plastic Pot.
Providing Plant Salvia red Hybrid dwarf variety having 15 to 23 cm ht., specimen 6 plants with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/ Nand
Providing Plant Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot,
Washingtonia filifera palm well developed 90 to 105 cm ht. plant having 5 to 6 straight fresh and healthy leaves in 35 cm Cement Pot
Supply and stacking of plant Cassia biflora of height 45-60 cm. in earthen pots of size 20 cm
Supply and stacking of plant Ficus panda of height 30-45 cm. with 3-4 branches and healthy foliage in p.bag of size 20 cm
Supply and stacking of plant Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm
Supply and stacking of plant Hibiscus variegated of height 60-75 cm. with healthy variegated foliage in earthen pots size 25 cm
Supply and stacking of plant Hibiscus variegated of height 60-75 cm. with healthy variegated foliage in earthen pots size 25 cm
Allamanda cathartica plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots
Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan, Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots.
Clerodendrum splendens plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots
Quisqualis indica plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots
Providing of Areca Palm plant, having ht. 1.20 m to 1.50 m with 5 to 6 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot / Plastic pot.
Providing of Areca palm plant, having ht. 1.50 m to 1.80 m with 6 to 8 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot / Plastic pot.
Providing of Croton Golden plant, having ht. 45 cm to 60 cm with 2 to 3 branches, well developed, fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot.
Providing of Diffenbachia Tropicsnow plant, having ht. 60 cm & above with 8 - 10 leaves, well developed, fresh & healthy in 25 cm size of Earthen pot / Plastic pot.
Providing of Draceana Song of India Green plant (three in one), having ht. 30 cm, well developed, fresh & healthy, lush green foliage from bottom to top in 20 cm size of Earthen pot / Plastic pot.
PORTABLE BADMINTON POLE COUGAR WITH WIGHT
TABLE TENNIS BOARD CAXTON
TABLE TENNIS BAT
TABLE TENNIS BALL
BADMINTON NET
BADMINTON ROCKET YONEX
SHUTTLE CORK YONEX PLASTIC
CARROM BOARD 44" X 44"
BILLIARD TABLE SET 12 FEET X 6 FEET WITH ALL ACCESSORIES
MULTI ADJUSTABLE BENCH (SUPER BENCH)
2.5 KG - 25KG CLASSIC RUBBER DUMBBELLS SET
2 TIER HORIZONTAL DUMBBELL RACK
200KG RUBBER OLMPIC DISC SET
PEC FLY/ REAR DELT MACHINE
HALF RACK
VERTICAL LEG PRESS
MULTI TRAINING STATION
BAR BELL RACK
OLYMPIC BARS
YOGA MATS
COMMERCIAL MOTORISED TREADMILL • Dimension : 87"(L) X 38"(W) X 58"(H). • Motor : AC Motor, 4.5 HP Continuous Duty, 9.0 HP Peak Duty. • Speed : 1.0 To 25 Kmph • Elevation : 0% To 18% Incline • Running Surface : 65" (L) X 24" (W). • Programs : 13 Programs, 12 Preset & 1 Body Fat & 1 Manual. • Display : LED With Scrolling Text 7 Windows, One Big Matrix, Show Time, Distance, Pulse, Speed, Calorie & Incline. • Power Requirements : 220V AC.
COMMERCIAL CROSS TRAINER • Dimension : 84” (L) X 30”(W) X 71”(H) • Strides : 20 Inches natural strides. • Maximum Watt : 250 Watts. • Resistance Level : 16 Levels. • Resistance System : Electromagnetic resistance. • Power : Self generated power system • Display : Dot matrix LED, scrolling text and computerized console. • Strides Wheel : Dual wheel track, fiber glass reinforced nylon wheel with high quality bearing. • User Weight : 175 Kgs.
COMMERCIAL SPINNING BIKE • Dimension : 52” (L) x 25”(W) x 50”(H) • Spin Wheel : 17 Kgs high inertia spin wheel. • Resistance Level : Pad breaking system with infinitely adjustable breaking power. • Resistance System : Adjustable resistance . "+" "-" tension control • Drive System : Centre design drive, Smooth, quiet belt drive mechanism. • Seat : Horizontally and vertically adjustable saddle with quick release. • Crank Assembly :3 Pieces crank assembly with increased strength provides dependable performance for every rider. • User Weight : 200 Kgs.
COMMERCIAL RECUMBENT BIKE E 1 187500 187500 • Dimension: 69”(L) X 25”(W) X 55”(H) • Resistance Level : 15 Levels. • Resistance System : Electro-Magnetic resistance. • Power : Self generated power system. • Seat : Ergonomically designed comfortable seat with flex back cushion contoured for lumbar support with horizontal slide adjustment. • Fly Wheel: 9 Kgs precision balanced. • Programs : 8 Preset Programs (P1 to P8), 1 manual & time, distance & calories can be set as per user requirement . • Drive System : Centre design drive, super silent poly-V belt driven. • Display : LED Display with computerized console. • Crank Assembly : 3 Pieces crank assembly. • User Weight : 200 Kgs.
Commercial Air Rower • Air Resistance Technology For Highly Effective Workout Which Targets Every Major Muscle Group. • High Strength Nylon Pedal Strap For A Smooth & Quiet Pull • Back-Lit LCD Monitor, Complete With 8 Pre-Programmed Rowing Routines • High Quality, Contoured Seat For Optimum Comfort • Steel Rowing Beam For A Smooth Rowing Motion. • Resistance: 9 Resistance Level • Holder: Cell Phone Bracket. • Display Instructions: User-Friendly Computer Console With Dot Matrix Display For Distance / Cycle, Meters Per Stroke / Freq. Min, Calories, Time, Watts, Pedal Width & Heart Rate • Pre-Set Workouts And Games • Requires 8 X 3-Ft. Space; 2-Piece Design For Storage. • Max. User Weight : 130 Kgs.
Labour Cess @ 1%
NIRKON INDIA
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
SBD.pdf
Tender Documents • 0.89 MB
BOQ_75280.xls
BOQ • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .