| 1 | L1₹10.4 LAccepted-AOC | ₹10.4 L Quoted ₹10.7 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹12.2 L+₹1.5 L (14.2%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | ₹12.2 L+₹1.5 L (14.2%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹13.0 L+₹2.3 L (21.7%)Rejected-Finance | ₹13.0 L+₹2.3 L (21.7%) | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹13.1 L+₹2.4 L (22.7%)Rejected-Finance | ₹13.1 L+₹2.4 L (22.7%) | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹13.6 L+₹2.9 L (27.1%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹13.6 L+₹2.9 L (27.1%) | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
1 Jun 2021, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Outsourcing of resources for operation and management of 11 KV Sub Station Air Force Station Jaisalmer
2021_MES_440970_1
8719/GE/E8
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (AF) Jaisalmer
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹30,000
Yes
19 Jun 2021
6 May 2021
3 Jun 2021
6 May 2021
1 Jun 2021
20 May 2021
Amount
Schedule 'A' Part-I General Note as applicable for serial item No 2.00 of BoQ/Sch 'A' Part-I Contractors attention is hereby invited that estimated cost of serial item No. 2.00 is Rs. 8,97,500.00 based on prevailing rates of Schedule of Minimum fair wages. Quoted amount against serial item No. 2.00 is less than the amount the work (Estimated of serial item No. 2.00 of BoQ/Sch 'A' Part-I) then lowest bidder will have to deposit FDR in favour of Accepting Officer within 07 days from financial bid opened difference in Estimated cost & quoted amount of serial item No. 2.00, in case lowest bidder said FDR is not submitted within stipulated period as mentioned above. The contractor shall be banned for 06 month & thier bid will be rejected and financial bid will not be opened for next 06 months. FDR submitted by the contractor within 07 days from financial bid opened and the same will be realesed only after satisfactory proof of payment of deployed person under the respective serial item No. 2.00 of Sch 'A' Part-I.
Manning and Operation of 11 KV Sub Station, Chandan 3 AFRU and all equipments installed at site and including DG Set, AC Plant etc. One (Skilled Electrician) in three shift of 8 hrs each for 24 hours continuous operation in a day (including Sunday/Hiliday) to maintain sub station in/out side HT Panels as specified, including daily and weekly check-up, monthly quarterly and half yearly maintenance as per Maint. schedule specified under particular specification with all minor consumable and expendable items and labour and tools for smooth and efficient operation all as specified and directed. Note for item No. 2.00 : (a) The contractor shall take over all equipment in serviceable condition at the time of commencement of contract and shall hand over in the same state at the time of completion of contract period. Any damage/loss shall be made good by the contractor at the time of completion of contract. GE's decision will be final and binding. (b) Daily cleaning of all Panels, transformers, recording meter readings. (c) Daily cleaning of all rooms viz floor, walls and ceiling fan including internal electrical fixtures. (d) No unauthorized person shall be allowed to enter in sub division. (e) 11 KV Sub Station will be operated 24 hours round the clock including Sunday/Holidays.
Notes for Serial item No. 2.00 :- (f) All T&P insulating cloths, for operators, log-books, instruction board duly laminated for 'DO or "NOT DO" Fire safety instruction board etc. shall be provided by the contractor. (g) During maintenance & operation of 11 KV Sub station, any parts found defective and require to be replaced same will be measured and paid under Schedule 'A' Part-II. (h) Contractor shall be responsible for group insurance for eleven month of manpower deployed by him against the contract. (j) Contractor shall provided proper uniform of the operator as deployed by him and dress code shall be approved by GE/AGE concerned. (k) Daily attendance register shall be maintained by both contractor and concerned JE and register weekly putup to concerned AGE for the record purpose. (l) Labour deployed by the contractor shall be responsible for complete area cleaning of 11 KV installation, DG Romm, AC Plant etc inside / outside all as specified and directed by Engr-in-Charge. (m) Fuel for operation of DG Sets shall be supplied by the Department as free for filling only. However storage facilities of fuel and collection of fuel from MES Store shall be provided by the contractor. (n) Daily log sheet for running hours, fuel consumption register shall be maintained by the contractor and signed by the JE /Other superintending staff employed by the contractor. (o) Daily checking of oil level, Oil pressure, priming, frequencey temperature shall carried out and records shall be maintained.
Schedule 'A' Part-II Sheet metal enclosure powder coated single phase DB VTPN 4 ways and neutral 415 Volts, AC, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable complete all as specified and directed.
MCB, Single Pole, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, Single Pole, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, SPN, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, SPN, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, TP, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCCB, 3 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 400 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
Sub main wiring with 6.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 6.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 95 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables 6 Sqmm including taking down old unserviceable cable complete all as specified.
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables 10 Sqmm including taking down old unserviceable cable complete all as specified.
Preparation of steel surfaces for electric poles and apply one coat of synthetic enamel paint upto 1.50 mtr length and making of pole number and five strips each 30cm wide in navy blue & white colour using synthetic enamel paind upto 1.50mtr height from top of PCC foundation block complete all as specified and directed.
Preparation of steel surfaces for steel tubular electric poles, swan neck pole of HT/LT over head line and all mild steel clamps, cross arms work on poles with apply one coat of superior aluminium paint upto 1.50 mtr length and making of pole number and five alternate strips each 30cm wide with black and navy blue colour for LT Poles and black and red colour for HT Poles using painted upto 1.50mtr height from top of PCC foundation block complete all as specified and directed.
Galvanized steel water tubing light grade of 40mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed.
Galvanized steel water tubing light grade of 50mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 50mm bore, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out soft/loose soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No. 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc including taking down old earth complete all as specified and directed. Note : (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Energy efficient LED street light fittings of Capacity 45 Watt, Aerodynamically designed street light with excellent thermal management in built tilt angle arrangement with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 100 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections including taking down old unserviceable complete all as specified and directed. Note :- Driver should be BIS registered with "R" marking.
Power Contactor 4 Pole, 500 Amps, type MCX-44 complete including taking down old unserviceable power contactor complete all as specified and directed.
Power Contactor 4 Pole, 160 Amps, type MCX-32 complete including taking down old unserviceable power contactor complete all as specified and directed.
Making earthing pit on existing old earthing where pit is completely damaged including cover 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation and earth work complete all as directed and directed.
Aluminium conductor, steel reinforced (ACSR) of any size, any type, as per existing one and stringing properly on the insulators and binding with aluminium wire 14 SWG, connectors, Jumpers etc complete all as specified and directed. (Note : Measurements and payments shall be made by measuring horizontal distance between centres of two adjacent pole and adding 3% for sag, jointing, jumpers etc).
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat primer, one under coat and one finishing coat of synthetic enamel paint including disconnecting & taking down old unserviceable complete all as specified and directed.
Pin type insulator porcelain vitreous, white, brown or green for working pressure 1100 volts, 100mm height and 65mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut including taking down crecked/unserviceable insulator complete all as specified and directed.
Shackle type insulator porcelain vitreous, white, brown or green, working pressure 1100 Volts, 90mm dia and 75mm height including galvanized mild steel straps of section 31mm x 3mm with 12mm dia insulator bolts, washers and nuts including taking down crecked/unserviceable insulator complete all as specified and directed.
Stay assembly complete with accessories as shown on electrical plate No 1 of SSR Part-I with 20mm dia 1800mm long stay rod, stay wire 7/4mm stranded galvanised including mild steel stay plate 300mm x 300mm x 6mm thick and galvanised thimble, galvanised steel 14mm dia 400mm long, stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90mm x 140mm clearance of hole 25.5mm, including necessary excavation, return filling, removal of surplus soil, loop insulator, clamp, stay wire and PCC 1:2:4, including taking out old unserviceable stay assembly complete all as specified and directed.
Pre Stressed concrete Pole 9.00 mtr long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles, including disconnecting & taking down old unserviceable broken RCC Pole complete all as specified and directed. Note : (i) Excavation in trenches in any types of soil, returning filling in and well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii) PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation bedding complete all as specified and directed. (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level complete all as specified. (iv) PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping including necessary form work complete all as specified and directed. (v) Painting of Pole upto 1.5mtr of height from coping level with alternative strip black and sky blue of width not less than 0.30 mtr and writing pole Number with yellow shade on black base using synthetic enamel paint having height of words exceeding 5cm complete all as specified and directed. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
On Load Changeover switch 200 Amp, 4 Pole, 415 volt, 50 Hz, sheet steel enclosure with front handle to be fixed on wall with flat iron 32x6mm including thimbles, nuts, bolts, washer etc complete, including taking down old unserviceable change over switch, complete all as specified and directed.
On Load Changeover switch 400 Amp, 4 Pole, 415 volt, 50 Hz, sheet steel enclosure with front handle to be fixed on wall with flat iron 32x6mm including thimbles, nuts, bolts, washer etc complete, including taking down old unserviceable change over switch, complete all as specified and directed.
Re-stretching only existing Aluminium conductor, steel reinforced (ACSR) of any size on HT/ LT Pole including binding the Aluminium conductor, steel reinforced (ACSR) with insulators, aluminium binding wire complete all as specified and as directed. Note : (i) The above work includes cleaning pruning of tree branches falling around the conductors (ii) One length shall be measured for complete span of any number conductors and GI wire.
Trimming of trees branches clearing both side 4.0 metre all around by cutting trees branches at ground level of any numbers and any girth on any number of conductor/earth wire of LT/HT over head line during the treeming first taken proper shutdown by informing the concerned JE (E/M) and Engr-in-Charge. Note : (ii) This item shall not operated against item No. 42.00 above. (ii) Pole to Pole distance shall be measured & paid as one unit.
Cable jointing kit for 1100 Volts grade LT cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 25 sqmm 3.5/4 core to 95 sqmm 3.5 core including dismantling & taking out old unserviceable jointing kit complete all as specified and directed
PVC LT line seperator on existing LT over head line to create gap between the line wire complete all as specified and directed. Note :- Necessary T&P as required like ladder/vehicle etc shall be arranged by the contractor for fixing the PVT LT line seperator.
PVC insulated and fire retardant PVC sheathed, copper conductor of round cable size 1.5 sqmm, 3 core for electric connection from feeder /looping box /street light over head line to street light fittings including taking out old unserviceable cable from pole all as specified and directed.
Preparation of existing old painted surface of any description such as LT Panel board, LT feeder Pillar box, LT bus bar chamber at any height and painted inside and outside (strictly existing shade) complete after scratching existing rusted surface then applying one coat of paint (superior quality smoke grey) to achieve fine finishing all around the panels and plinth including repairing of complete LT panel by welding of hinges, door and locking arrangement complete all as directed and directed.
Boring Hole/Driling (Horizontally) under the road / pavement / hard standing with the help of trenchless and necessary machine for inserting Galvanised steel pipe of size 100/80mm not less than one metre below ground level complete all as specified and directed Note : GI pipe shall be measured and paid for seperately in respective items.
M/s Ramesh & Company
SS SODHA ENTERPRISES
JAI ENGINEERING COMPANY
M/s Shree Construction Company
M/S SHRI HARI CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .