Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC | L1 | Accepted-AOC L1 being accepted. | |
| 2 | L2₹43.1 L+₹68,587.09 (1.62%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹43.1 L+₹77,646.76 (1.83%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹43.4 L+₹1.1 L (2.53%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹43.7 L+₹1.3 L (3.11%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹38.4 L
EMD Value
₹76,700
Closing Date
24 May 2024, 6:00 pmClosed
GARRISON ENGINEER 867 EWS
GE 867 EWS, C/O 99 APO, PIN 913867
SPECIAL REPAIRS TO BLDG NO P-236/1 TO 6 (OR MD ACCN) AT RWA EME ZONE AT KALIMPONG MIL STN UNDER GE 867 EWS
2024_MES_652076_1
GE/867/TOKEN/13 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
KALIMPONG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
₹76,700
20 Jul 2024
3 May 2024
31 May 2024
3 May 2024
24 May 2024
17 May 2024
Amount
Dismantling of plain or corrugated steel sheeting, any gauge and thickness including Nainital or similar pattern roof coverings, complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet (AZ-150) of approved profile of corrugation, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick (AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description, complete all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet, complete all as specified and as directed.
S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensor system (Grid) made out of GI sheet main Tee of size 23.5mmx38.50mmX0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmx19mmX0.36 mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction, complete all as specified and as directed. (Make : Everest or equvalent as approved by GE)
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring, 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in CM (1:6) finished even and rough, complete all as specified and as directed.
M&L for machine cut Kota stone slab as in vertical surfaces such as dado/skirting, 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 10 mm thick rendering in CM (1:4) finished even and rough, complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to IS-13712, grade B-II(a) (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in vertical surface such as skirtings, dados and riser to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in CM (1:6), complete all as specified and as directed.
M&L coloured glazed ceramic tiles 350X250 mm X7mm thick / 450X350X7mm thick fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick backing plaster in CM (1:4) finished even and rough, complete all as specified and as directed.
Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
M&L for 15 mm thick rendering in CM (1:6) on brick work or concrete surfaces, complete all as specified and as directed.
M&L 20 mm thick rendering ( in two coats 10mm+10mm) on fair faces of brick work or concrete surface in CM (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated, complete all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.
Supply only integral water proofing compound, complete all as specified and as directed.
M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces CM (1:3) on concrete surface as in ceiling/chajja and RCC surfaces , to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed.
M&L for complete removal of existing treatment and applying two coat of cement base paint on wall, complete all as specified and as directed.
M&L for preparation of newly plastered surfaces and applying two coat of cement base paint, complete all as specified and as directed.
M&L complete removal of existing treatment on wall and applying two coats of oil bound distemper over plaster of paris putty of 1 mm thickness, complete all as specified and as directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over plaster of paris putty of 1 mm thickness, complete all as specified and as directed.
M&L preparation of newly plastered surfaces of ceiling applying two coats of white wash, complete all as specified and as directed.
M&L preparation of newly plastered surfaces of ceiling applying one coat of white wash, complete all as specified and as directed.
Demolition of brick work or stone/boulder masonary buit in cement mortar including all quions ,arches ,pillars etc but excluding ashler facing dressed stone work and precast, complete all as specified and as directed.
M&L for on plan exc 6 m straight or curved fly ash bricks built in CM (1:6), complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts , coping, filling in pressed steel chowkat or similar work including necessary form work as required, complete all as specified and as directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition, complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B1 (Using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed.
Use & Waste of formwork to sides and soffits of shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and as directed.
S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed.
S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed.
Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and as directed.
S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed.
S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed.
S&F of 110 mm bore PVC (SWR) bend any radius with access door, complete all as specified and as directed.
S&F of 75 mm bore PVC (SWR) bend any radius with access door, complete all as specified and as directed.
S&F of 110 X 75 mm bore PVC (SWR) reducer including jointing with solvent cement, complete all as specified and as directed.
S&F in repairs Brass chromium plated shower rose with or without swivel joints 125 mm size including fixing to steel pipe or union, complete all as specified and as directed.
S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, complete all as specified and as directed.
S&F in repairs angle stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed.
S& F Stainless Steel Sink mixure, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed, complete all as specified and as directed. Make : Jaquar or equivalent as approved by GE.
S&F in repairs kitchen plate rack made out of stainless steel 0.50 mm thick sheet with partitions and size of rack 800 x 250 x900 mm with shape and pattern as per sample kept in Sample room of GE Office, complete all as specified and as directed.
S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S& F Brass CP Basin mixure, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed, complete all as specified and as directed. Make : Jaquar or equivalent as approved by GE.
S&F wall mixer 2 in 1 System-FLR with Provision for Overhead shower with 115 mm Long Bend pipe of make Jaquar or equivalent, complete all as specified and as directed. Make : Jaquar or equivalent as approved by GE.
S&F in repairs brass chromium plated tubular towel rail of 20mm dia D' type 60cm long between flanges, complete all as specified and as directed.
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed.
S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws, complete all as specified and as directed.
S&F in repairs Grating doom 100mm dia, complete all as specified and as directed.
S&F in repairs PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and as directed.
S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete, complete all as specified and as directed.
S&F Vitreous China wash basin, flat back, size 450x300mm white, excluding taps, waste, chain and plug and rcelain stopper but including brackets, complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and as directed.
Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, complete all as specified and as directed.
Taking up or down 20 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, complete all as specified and as directed.
S&F Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and as directed.
S&F in repairs 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement, complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and refixing in same opening after Resecuring or easing & adjusting, complete all as specified and as directed.
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed.
Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed.
S&F 30 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and without sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats, complete all as specified and as directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
S&F 30 mm thick (batten thickness) second class hard wood, Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; t both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed.
S&F Pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed.
S&F Pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed.
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed.
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed.
M&L for 18/19 block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work, complete all as specified and as directed.
M&L for second class hardwood plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or screws, sectional area exc 3 cm and n exc 6 sqm, complete all as specified and as directed.
S&F Mild steel pressed handles, 100mm oval type, stove enamelled black, complete all as specified and as directed.
S&F Mild steel barrel tower bolts 100mm, stove enamelled black, with bright bolt and fixed, complete all as specified and as directed.
S&F Butt hinges, heavy weight, cold rolled mild steel, and fixed, complete all as specified and as directed.
S&F Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws, complete all as specified and as directed.
S&F Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed.
S&F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and as directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, complete all as specified and as directed.
S&F 150 mm size Aluminium handles, cast type, anodised and fixed, complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones, complete all as specified and as directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane, complete all as specified and as directed.
S&F mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-410-0 or Fe 310-0, complete all as specified and as directed.
S&F in repairs 25mm dia curtain rod (curtain rails), alumunium alloy, powder coated with and including decorative knobs etc, complete all as specified and as directed.
M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed.
M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed.
M&L preparation of new wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
M&L preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar, complete all as specified and as directed.
M & L Granite (of any type) work 20MM thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed.
M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection/ path laid slope of 1 in 12 and finshing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges, complete all as specified and as directed. .
M & L for 75mm th Plain cement concrete (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), in sub baseccomplete all as specified and as directed.
M/L polished chequered cement concrete tiles with grey cement and pigment 300X300X25mm thick set jointed and pointed in neat cement slurry complete all as specified and as directed.
M&L 20 mm thick screed bed in CM (1:6), complete all as specified and as directed.
M&L for PCC (1:3:6) Type C-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete with using extra cement incl. forms moulds, mitred / stoped ends, complete all as specified and as directed.
M&L for dismantling of existing water closet after disconnectiing the flush pipe, demolition of entire floor upto bottom of sunken portion, removing debries cleaning the top of the RCC slab in sunken portion incl peripheral surfaces and plastered with 10mm thick cement & sand mortar (1:3) using WPC finished even and smooth without using extra cement cured properly and allowed to dry and applying two or more coats of epoxy resin/polymer modified cementatious coating like brush bond of Fosroc or equivalent both on floor and wall surfaces applied as per manufacturers instructions and plastering the treated surfaces (after testing)for water tightness) 15mm thick with CM (1:3) with WPC incl providing 20mm dia GI spout with 300 mm projection beyound outer face of wall, complete all as specified and as directed. (Area of each WC/Toilet 0.90x1.80)
Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch, socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes, complete all as specified and as directed.
Dismantling and taking down unserviceable main switches, DBs including sub main wiring etc. any type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping not less than 20mm size, medium grade with all necessary fittings, surface wiring, for light /Bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/ on PVC rectangular block with 3 mm thick plastic laminated sheet cover of suitable size (concealed type in permanent bldg and surface in temporary bldg or as directed ) for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc, complete all as specified and as directed. Including testing on completion.
All as per item No 103 here – in – before but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size
All as per item No 103 here-in-before but One 3 pin socket outlet 5/6 Amps on the same board with other switchs with cables 1.5 Sqmm size.
All as per item No 103 here – in – before but for one 3 / 5 -pin switch socket outlet 5/6 amps on independent board.
All as per item No 103 here – in – before but for one switch socket outlet 15/16 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable.
Supply and fix switch piano flush button, single pole, 5/6amps, one way, complete all as specified and as directed.
Supply & fixing Bell push flush type, 5 Amps button, complete all as specified and as directed.
Supply & Fixing Bell, AC 230 Volts single pole including mounting block, complete all as specified and as directed.
Supply and fixing lamp/angle holder insulated body with back plate for batten fitting, complete all as specified and as directed.
Supply and fixing LED retro fit lamp B-22, CCT- 3000 K/ 6500 K holder base with poly carbonate body and aluminium heat shrink of 9 W, complete all as specified and as directed. CAT Part No : LHLDDBEBBI8R009 of havells or equivalent in Crompton/Surya/Philips.
Supply and fix switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5/6 amps flush type, complete all as specified and as directed.
Supply and fixing switch socket combination 2 – in – one 6 Pin , 6 / 16 amps flush type universal, complete all as specified and as directed.
Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal, complete all as specified and as directed.
Supply and fixing Decorative, wall mounting, made up of Polycarbonate body suitable for 10 W LED lamp (B-2 base), complete all as specified and as directed. Cat part No LHDL06160099 Model CITY-3 Make-Havells or equivalent model of Philips/Bajaj/Crompton.
Supply and fixing LED tube lights fitting, 4 feet long 1x 18W, 220V, AC decorative box type with holder including Removable poly cabonate LED tube light with inbuilt driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
S&F metal plug socket single pole and neutral encloser with two pin earth plug with 01 No MCB SP 20 Amp, C series, complete all as specified and as directed.
Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, concealed in wall, complete all as specified and as directed.
S&F TPN DB with suitable for TPN MCB incomer, double door (IP-54), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz, concealed in wall, complete all as specified and as directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP in the DB complete with connection testing and commissioning, complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed.
M&L for sub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC conduit concealed in wall/roof, complete all as specified and as directed. (Note: Three run of 6 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length including taking down of old servicible sub main wiring.)
M&L in repairs for sub main wiring along with earth wire of size two run of 4 sq mm + one run of 4 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof, complete all as specified and as directed. (Note: Three run of 4 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length including taking down of old servicible sub main wiring.)
Taking down electric meter and keeping in safe custody of MES store for reuse, refixing the same with all accessories and necessary fixing arrangements, complete all as specified and as directed.
Taking down existing exhaust fan and keep in safe custody to the MES store and refixing the serviceable exhaust fan to existing location including necessary electric connection grouting of MS fastener of suitable size, complete all as specified and as directed.
Taking down water storage heater (Geyser) and keeping in safe custody of MES store for re-use, refixing the same with all accessories and necessary fixing arrangements, complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC (1:3:6) type C-1, 50 mm thick precast RCC (1:2:4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No.5 of MES SSR Part-I, complete all as specified and as directed.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
G K SUTHAR
PRASAD PRADHAN AND SON
HEM RAJ GURUNG
SANJAY SAW MILL
DEEP CHANDRA JOSHI
MS MAYA PRAKASH GOEL AND SONS
RAMESH GURUNG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .