Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
8 Jul 2022, 12:00 pmClosed
SE EDC 2
PALLAVPURAM
REGARDING ERECTION OF POLE IN LONG SPAN, GUARDING OF LINE AND FIXING PVC SHEER ON STEEL POLE AND STREGHTENING OF 11 KV LT LINE AT KAWAR MARG IN UNDER THE AREA OF EDD-II MAWANA UNDER EDC-2 MEERUT.
2022_PVVNL_710838_1
T63/2022-23
Open Tender
Electrical Works
Lump-sum
90 days
EDD MAWANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC 2
₹2,000
8 Jul 2022
25 Jun 2022
8 Jul 2022
25 Jun 2022
8 Jul 2022
25 Jun 2022
Amount
Cartage of following from store center Meerut to JE store including loading & unloading at both ends maximum distance up to 40 Km.
A) PCC pole 8.5 mt long
B) STP 11 mtr long.
C) Line material such as Stay rod, Stay wire, ACSR weasel, ACSR Rabbit conductor, GI wire, MS Chennel, MS angle. Etc
Cartage of following from JE store to Site of work including loading & unloading at both ends maximum distance up to 40 Km. A) PCC/ pole 8.5 mt long
B) STP 11 mtr long.
C) Line material such as Stay rod, Stay wire, ACSR weasel, ACSR Rabbit conductor, GI wire, MS Chennel, MS angle. etc
Erection of PCC pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.5 mtr in all type of Soil including back filling of the pole with proper ramming including fixing of LT& HT line accessories
Erection of ST pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.5 mtr in all type of Soil including back filling of the pole with proper ramming including fixing of LT& HT line accessories
Fabrication & Fixing of 11 KV Cross arms of MS Angle iron of size 65X65X6 mm Traightening, cutting and drilling the holes.
Guarding of line with G.I. wire having 2 no horizontal wire& 3 Mt distance odf laces of ten SWG G.I wire after fabrication of guard cross arms of & fixing the same in supports.
Repairing of old & rusted Guarding of line with G.I. wire having 2 no horizontal wire& 3 Mt distance odf laces of ten SWG G.I wire after fabrication of guard cross arms of & fixing the same in
Providing & fixing bamboo strips in 3 phase 4 wire in LT line with proper binding.
Cutting & Chopping of tree branches near side of line for making clearance beetween line & tree.
Re-sagging of lose sag of LT line & HT line after opening the bindings then stringing the conductor & rebinding jumpring the same properly.
Providing and fixing the plastic sheet around the steel round pole/ RS joist/Rail up to 7' height from bottem of pole to avoide any misshappenings due to earth fault as per instruction of higher authorities.
Straightening of tilled PCC Pole of 11 KV/LT Lines after opening the bindings from insulators and digging the pit for require depth and refilling the same pit after completion of work including rebinding the conductor with insulators & sagging the conductor.
Reparing of LT Leads of medum power T/F with HT tape empire tape and pvc tape.
Replacment of Dameged LT PVC lead of size 1x400 sq. mm.
Reparing of Damaged & missing part of fencing of medum power T/F plinth.
Baracating of medium power T/F at various places at road side with the help fo wooden balli. Card-bord & bamboo etc.
Replacment & Reparing of old & rusted jumpers of 11 KV & LT line.
Fixing of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.8 Mt and grouting the same in block of size 0.60 x 0.60 x 0.30 Mt and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
Replacement of damage & burnt conductor of LT line with conductor including opening the bindings & removal of damage conductor & making the role then laying lifting sagging & stringing of new conductor with proper bindings & jumprings.as follows:- A). ACSR Wieasel Conductor.
Earthing of STP properly after drive of electrodes if size 20mmx250mm and connection the earthing point with GL wire.
Providing and fixing stay clamps with Nuts & bolts.
Providing and fixing Stay Insulator with Nuts & bolts.
Providing and fixing Holding clamps with Nuts & bolts.
Providing and fixing F-brecket with nuts & bolts
Grouting of ST Pole in block of size 0.45x0.45x1.5 Mtrs. In CC 1:4:8 with Cement, sand & Brick ballast. (All material shall be providing by the Contractor)
Laying of LT ABC Cable of size 3x503x95x3x120
M/S KAVITA CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .