Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC 6 GURU GOBIND SINGH NAGAR DHAKOLI DHAKOLI PATIALA PUNJAB 140602 | PATIALA | PUNJAB | 140602 | L1 | Accepted-AOC Being a first lowest | |
| 2 | L2₹22.7 L+₹1.9 L (9.16%)Rejected-Finance BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹51,354
Closing Date
25 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(West)Pathankot
GE(West)Pathankot
PROVN OF INTERLOCKING PATHWAY IN UNIT AREA, SPL REPAIR TO SEWAGE LINES AT OTHER RANKS TOILET AREA TO MAIN SEWAGE LINE, AND SPL REPAIR TO BLDG No. P-6/BC(OR BATHROOM) UNDER GE (WEST) PATHANKOT
2023_MES_615752_1
GE/PKT-38/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
Pathankot
As per tender and NIT doc
9 documents required · 9 mandatory
₹500
GE(West)Pathankot
₹51,354
7 Nov 2023
25 Aug 2023
26 Sept 2023
25 Aug 2023
25 Sept 2023
11 Sept 2023
Amount
Surface dressing n exc 15 cm deep in any type of soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for hardcore of Broken stone or boulders n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base Finishing surfaces of concrete to be even and rough complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base Finishing surfaces of concrete to be even and rough complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation or layer of sand cushioning below interlocking paver block complete all as specified and as directed.
M&L for Coloured machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-40 grade rubber moulded glossy finish with grey cement and pigment complete all as secified and as directed. Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks (50% yellow and 50% Red) & laying pattern approved by GE.
M&L for Coloured machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 80 mm thickness, M-40 grade rubber moulded glossy finish with grey cement and pigment complete all as secified and as directed. Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks (50% yellow and 50% Red) & laying pattern approved by GE.
M&L for Cement Concrete , 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in lintel upto 1.50 m span, cills, steps, seismic and other silmilar bands, plinth courses, sring courses,lacing courses, parapets and railings upt 60 cm in height, copings, kneelers, apex stones, bed plates, water troghs and the like including weathering, slightly rounded or camphered angles and throating, complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil.
All as per Srl item No. 11 here-in-before but exc 1.5m and n.exc 3m in depth
Excavation over area not exceeding 1.5 m depth soft/disintegrated soil, complete all as specified and directed by Engr-in-Charge.
All as per item No 13 here-in-before but exceeding 1.5 m and not exceeding 3.00 m depth.
Demolition and breaking up drain pipe (salt glazed stone water or AC)/SWG of any dia set in cement mortar, complete all as specified and directed by Engr-in-Charge.
M&L for HDPE DWC pipe 200mm internal dia and external dia 230mm SN-08 laid in tranches and jointed with cement solvent including testing complete all as specified and as directed by Engineer-in-Charge.
M&L for concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 200 mm bore pipe, complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Removal to excavated material (Soil) to a distance exc. 250m but n.exc 500m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by the Engr-in-Charge.
M&L for PVC (SWR) gully/floor trap 110 mm with grating and 300mm long outlet, setting and jointing with solvent cement
S&F in repair PVC (SWR) bends any radius of 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall of 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) junction single, (single-T), equal or unequal of 110mm bore complete all as specified and directed by Engr-in-Charge.
M&L for RCC design mix, M-25 type B-1 ( using 20 mm graded crushed stone aggregate ) as in Beams, cantilevers, bressummers, lintels over 1.5m span (Note:-TMT bars will be masured and paid sepretly)
M&L for RCC design mix, M-25 type B-1 ( using 20 mm graded crushed stone aggregate ) as in slabs supported on walls, beams and columns in floors, roofs, complete all as specified and directed by Engr-in-Charge. (Note:-TMT bars will be masured and paid sepretly)
Precast reinforced cement concrete, type B-1,1:2:4 (using 20mm graded crushed stone aggreagate)as in manhole cover set in cement mortor 1:4 , complete all as specified and directed by Engr-in-Charge. (Note:-TMT bars will be masured and paid sepretly)
S&F mild steel TMT bars 10 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
S&F mild steel TMT bars 6 to 8 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves and similar work not exc.200 mm thick (horizontal or slopping) for fair finished flat surfaces all as specified and as directed.
S&F in repair 100mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete all as specified.
S&F in repair 100mm dia Cast iron cowls
M&L for brick work with sub-class 'B' bricks in one brick thick honey comb work, built in CM 1:4 complete all as specified and as directed.
M&L for brocken brick as Loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells
Demolition of brick or stone/block masonry built in cement mortar including all quions, arches, pillars etc., but excluding ashlar facings, dressed stone works and precast cement articles, complete all as specified and directed by Engr-in-Charge.
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 10 mm thick on fair face of brick work or concrete/stone surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified.
M&L for Rendering 20 mm thick on fair face of brick work or concrete/stone surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified.
M&L for Rendering 15 mm thick on fair face of brick work or concrete/stone surfaces in CM 1:4 including mixing liquid water proofing compound as per manufacturer instructions, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work, stone, concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 05 mm thick rendering on brick work or concrete surfaces in CM 1:3 as in ceiling of roof slab ,fin, facia, culvert, chajjas, parapet and similar article etc finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge ..
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in , plinth protection and surface finished even and fair with out using extra cement including making joints at every 2.5m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight all as specified and as directed.
S&F in repair Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Surface excavation not exc 30 cm depth and averaging 15cm deep in foul condition for removing heaps of waste, cleaning of flora, fauma, follage and bushes around septic tanks,manholes and soak pits removing debris/ heaps of bushes etc from vicinity and depositing at a place where complete all as specified and as directed
M&L for non abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match including 75mm thick sub base of PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate complete all as specified and directed by Engg-in-charge.
S&F in repair vitreous china wash down water closet (Orissa pattern white of size 580 mm x 440mm with integral foot rest, CI "P" or "S" trap all fittings complete including connection to trap and to flushing pipe anti syphonage pipe including making good to floor,cleaning surface etc complete all as specified and as directed
Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed for manholes of following size of manholes of depth not exceeding 1.00 meter
Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed for manholes of following size of manholes of depth exceeding 1.50 meter but not exceeding 2.00 meter
Cleaning of sewage line in any depth including affected/connected manholes and desludging, dewatering of man hole of any size by mechanical sucking/pressure pump(truck mounted) including cleaning of connected sewage pipe line of size 100/150/160/200/300mm bore laid in trenches and any length,including water closet, gully trap etc by hydraulic jet pressure machine as required at site flushing the line and manholes with water as to make the fully functional line with man hole to entire satisfaction of Engr-in-charge and removing sludge out side the periphery of defence land at his own arrangement where sanitary hazards do not take place as per direction/instruction of civil authority and burried in excavated pits and covering the same. Adequate water for flush out sludge to be arranged by the contractor without any extra cost.Pipe line including manholes cleared/ cleaned under this item is to arranged by the contractor without any extra cost.pipe line including manholes cleared/cleaned under this item is to be maintained by the contractor and kept fully functional by removing any type of blokage of entire period of completion of work without any extra cost and refixing manhole cover after cleaning all as specified and directed. Note: unit rate quoted by tendere shall include taking out sludge from line and manhole(liquid,semi-liquid,solid) excavation of borrow pit for dumping sludge, removing including loading, unloading and transportation etc
Taking down chowkhats or frames exc 1.50 and n.exc 4 Sqm each (without talking off shutters from the freme) complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site.
Taking down shutters of any description exc 1 sqm but not exc 2 sqm each and removing from site complete all as specified and directed.
S&F factory made Pressed steel frame of size 105x60x1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete and back filling of hollow portion of frame including fixing of hold fast with plain cement concrete type B-0, 1:2:4 using 12.5 mm graded crushed stone aggregate including applying two coat of synthetic enamel paint over a coat of pink primer complete all as spd and directed
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F factory made 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, including 2 coat of synthetic enemal paint over a coat of primer confirming to IS- 2202(Part-I-1999) , ISI Marked complete all as specified and directed
S&F 100mm long butt hinges, medium weight, cold rolled mild steel
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised
Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified .
All as per srl item No 68.00 above but 20mm bore Steel water tubing
M&L for 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed.
All as per srl item No 70.00 above but 20mm bore Steel water tubing
S&F in repair 500 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 02 nos 20mm dia tank nipple and 01 Nos 32mm dia drain plug, Ball valves 20mm bore high pressure of PTMT with epoxy coated aluminum rod & high-density plastic ball screwed for iron pipe & fixed. (min. weight 20mm-210 gms) complete all as specified in SSR Part I
S&F in repairs Viterous China wash basin, white, flat back, size 550x400mm excluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand, 32mm bore brass CP waste fittings with long screwed shanks and fly nut with 32mm bore LDPE flush pipe of pressure rating 6kgf/Sqcm 1m long complete all as specfied and as directed.
S&F in repair PVC low level valveless, flushing cistern 10 Ltr capacity with inlet , ball valve, float valve and handle & including brackets for fixing to walls and PVC flush pipe of LDPE pipe of pressure rating 6 kg (f)/ sq.cm complete all as specified and directed by Engr-in-Charge.
S&F in repair Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S&F in repair CP brass towel ring 20mm dia, fancy type, superior quality, including CP screws and wooden/plastic cleats complete all as specified and as directed.
S&F in repair 15mm bore dia fancy type, chromium plated angular valves /stop valves, cast copper alloy, screwed down, high pressure ,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair for 15mm bore Stop valves, fancy type, chromium plated with long shank and cup (concealed type),cast copper alloy, screwed down, high pressure, with crutch or above butterfly handle, screwed both ends for iron pipe or for unions complete all as specified .
S&F in repair 15 mm bore long body CP Bib taps cast copper alloy fancy type with capstan heads (chromium plated),and with crutch or above butterfly handle , high pressure for iron pipe (minimum weight 575 gram)complete all as spd & directed.
S&F in repairs Swan neck CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed for iron pipe (minimum weight 665 gram) complete all as specified and directed.
S&F in repairs Brass CP overhead shower rose 190mm dia (ABS body CP with gray face plate) with rubit cleaning system including fixing to steel pipe or union complete all as specified and directed.
S & F in repair corner glass shelf with bracket fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed.
S&F in repair Brass CP Soap Dish or Soap Holder Dish for Bathroom with fixing arrangement complete all as specified and as directed.
Taking down eaves gutter and rain water pipe any size any pattern ,PVC/ AC pipe including all fittings ,Internal dia of pipe in 75/110mm complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall of 75mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall of 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends 75mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) gully/floor trap 75 mm with grating , setting and jointing with solvent cement
Demolition of existing roof treatment of any description such as worm out tarfelt, mortar of any description & any thickness, shrubs/roots ,vegetation, tree, terracing pcc/brick tiles, concrete bedding etc as directed and Cleaning of all foreign material debris etc by brushing and dusting, washing down with water etc ,surface shall be leveled with a layer of 20 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer's instructions and applying roof treatment with 03mm thick APP modified membrane with non-woven polyster reinforcement(center core) with thermal insulation with white mineral gravel finish on upper side of weight not less than 3.5 kg/sqm , laid by torch application method with overlap 100 mm on length side and 100 mm on the width side as per manufacturer's instructions over one coat of approved cold applied bituminous oil based primer (IS-3384) @ 0.30 litre/sqm complete all as specified and directed.
Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
M&L for Non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:4 including dismantal existing all as specified and directed.
M&L for Glazed coloured ceramic tiles in vertical surface 300X 200X 7mm thick such as skirting dado, etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shed of tile including laid over 10mm thick backing layer of cement mortar (1:4)
S&F in repair 15 mm dia PVC connection of 600mm long including brass check nut at both end.
S&F in repair steel window/Ventilator factory made box type and shutter (double shutter) with sash bar made out of section using flash butt welding, hinges shall be provided to both shutters complete including all fittings including grills made out of 10 mm dia round bars glazing with 3 mm thick oridinary glass, guaging (wire mesh stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts ) and two coat synthetic enamel paint over and including a coat of red oxide primer all as per drg No CEPZ/ TD/032/13 Sheet 1/2 including taking out old windows complete all as specified & directed.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 41,784.00 and any other reduction if any from quoted amount.
GANDOTRA CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .