General Manager (Engineering)
Haldia Dock Complex Syama Prasad Mookerjee Port
Replacement of existing electrical wiring and appliances at Mooring crew building, Marine Operations Division of Haldia Dock Complex (HDC), SMP, Kolkata
2020_KoPT_582459_1
SDM(P and E)/ T/ 71 /2020-2021
Open Tender
Job Works
Works
120 days
Haldia
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Syama Prasad Mookerjee Port, Kolkata - H.D.C.
₹7,859
Yes
1 Oct 2020
8 Sept 2020
1 Oct 2020
8 Sept 2020
30 Sept 2020
9 Sept 2020
120 days
Amount
Providing PVC pipe of following diameters [thickness not less than 3 mm] complete with fittings, as necessary, by cutting channel of suitable size on masonry wall / floor and fixing the pipe (approx. 18 mm below the top surface of the wall / floor ) by means of iron hooks / binding wire , including mending good damages to building works.
(a) 13 mm dia
(b) 19 mm dia
Providing 'FR' PVC insulated (unsheathed), single core, 1.1 kV grade, copper (stranded) wire (ISI marked) of the following sizes, in the prelaid PVC pipe and making necessary connection, as required.
(a) 2 X 2.5 mm2 (as phase & neutral wires) and 1 X 1.5 mm2 (as Earth Continuity Conductor)
(b) 2 X 4.0 mm2 (as phase & neutral wires) and 1 X 2.5 mm2 (as Earth Continuity Conductor)
(c) 2 X 6.0 mm2 (as Earth Continuity Conductor)
Finishing Copper Wire ends Finishing of the ends of 1.1 kV grade, copper (stranded) wire, by socketting with pin / ring type copper sockets , insulating tapes, etc., including supplying sockets, tapes, etc., as required.
Distribution wiring (alongwith earth wire) [average run 6 m], with 'FR' PVC insulated (unsheathed), single core, 1.1 kV grade, copper (stranded) wire (ISI marked), in suitable size [minimum 13 mm bore, 3 mm thick] PVC concealed pipe [complete with all accessories] embedded in wall, to light / fan / exhaust fan / call bell point [ including supply & fixing of 3 way Ceiling Rose/Batten Holder / Connector, as required ], with Piano Key type switch fixed on CRC sheet metal (16 SWG) switch board with Perspex / Bakelite top cover (3 mm thick) flushed on wall, including necessary connections & making earthing attachment and mending good damages to building works. 2 X 1.5 mm2(as phase & neutral wires) and 1 X 1.5 mm2 (as Earth Continuity Conductor), per point.
Distribution wiring (alongwith earth wire) [Average run 6 m], with 'FR' PVC insulated (unsheathed), single core, 1.1 kV grade, copper (stranded) wire (ISI marked), in suitable size [minimum 13 mm bore, 3 mm thick] PVC concealed pipe [complete with all accessories] embedded in wall and in suitable size PVC casing-capping for ceiling / beam portion only, to light / fan / exhaust fan / call bell point [including supply & fixing of 3 way Ceiling Rose/Batten Holder / Connector, as required ], with Piano Key type switch fixed on CRC sheet metal (16 SWG) switch board with Perspex / Bakelite top cover (3 mm thick) flushed on wall, including necessary connections & making earthing attachment and mending good damages to building works. 2 X 1.5 mm2(as phase & neutral wires) and 1 X 1.5 mm2 (as Earth Continuity Conductor), per point.
Providing double door, sheet steel, powder painted, TPN MCB Distribution board [4 way (4+12), with IP-43 protection and complete with tinned copper bus bar, copper connecting leads, neutral bar, earth bar & din bar] (concealed in wall) by cutting the masonry wall & mending good the damages to original finish, including inter-connection and provision for earthing attachment. (Without MCB / RCCB / Isolator)
Providing following double door, sheet steel, powder painted, SPN MCB Distribution Board [ with IP-43 protection and complete with tinned copper bus bar, copper connecting leads, neutral bar, earth bar & din bar] (concealed in wall) by cutting the masonry wall & mending good the damages to original finish, including inter-connection and provision for earthing attachment. (Without MCB / RCCB / Isolator) 2+10 way
Providing sheet steel, duly painted, 2 way MCB Distribution Board (concealed in wall) by cutting the masonry wall & mending good the damages to original finish, including provision for earthing attachment. (Without MCB / RCCB / Isolator)
Providing 240 V / 415 V, 50 Hz, MCB (C characteristics, 10 kA Breaking capacity) on din rail of existing DBs and necessary connection.
(a) TPN, 100 A
(b) SPN, 6 A - 32 A
(c) SP, 6 A - 32 A
Providing Socket type fan regulator (Step type) on existing sheet metal switch board having Bakelite / Perspex top cover by screw, after making housing for regulator, by cutting Bakelite / Perspex top cover and making necessary connections, as required.
Supply and delivery of 1200 mm sweep Ceiling Fan, suitable for 230 V AC, 50 Hz supply system, complete with capacitor, canopy & all accessories and should have BEE (Bureau of Energy Efficiency) star rating - 5 and as per the "Technical Specification" enclosed.
Fixing only ceiling fan complete with blades, canopy, rubber bush, etc. and making connection [ by providing flexible copper connecting wire (3 X 1.5 mm2)] as required.
Supply and delivery of 600 mm heavy duty sweep Exhaust Fan [ with blade, powder coated] suitable for 230 V AC, 50 Hz supply system, complete with all accessories and as per the "Technical Specification" enclosed.
Fixing only exhaust fan of diameter 600 mm and making connection as required
Supply and delivery of 1 X 20 W , 4 ft LED tube light fittings [box type], complete with all accessories & lamp, suitable for 230 V AC, 50 Hz supply system and as per the "Technical Specification" enclosed.
Fixing only tube light fittings / post top light fittings / round light fittings / single bracket lights / calling bell, complete with all accessories, directly on wall / ceiling / post top / PVC or HW Block by screws / MS fastener.
Distribution wiring (alongwith earth wire), with 'FR' PVC insulated (unsheathed), single core, 1.1 kV grade, copper (stranded) wire (ISI marked), in suitable size [minimum 13 mm bore, 3 mm thick] PVC concealed pipe [complete with all accessories ] embedded in wall , to 240 V, 6 A, 3 pin socket outlet (plug) point [including supply & fixing of 240 V, 6 A, 3 pin flush type socket outlet (plug) & Piano Key type switch on existing CRC sheet metal (16 SWG) switch board ( of light & fan) with Perspex / Bakelite top cover (3 mm thick) flushed on wall], including necessary connections & making earthing attachment and mending good damages to building works. 2 X 1.5 mm2(as phase & neutral wires) and 1 X 1.5 mm2 (as Earth Continuity Conductor), per point.
Providing (after cutting the brick wall) CRC sheet metal (16 SWG) JB-cum- Switch Board (having earthing attachment) of the following sizes , including Bakelite / Perspex top cover (3 mm thick) flushed in wall, including painting and mending good damages to building works.
(a) 100 mm X 100 mm X 50 mm
(b) 150 mm X 100 mm X 50 mm
(c) 175 mm X 100 mm X 50 mm
(e) 250 mm X 100 mm X 50 mm
Providing 240 V, 16 A Piano Key type switch on existing sheet metal switch board having Perspex / Bakelite top cover by screws, after making housing for switch, by cutting Perspex / Bakelite top cover and making necessary connections [with 'FR' PVC insulated (unsheathed), single core, 1.1 kV grade, copper (stranded) wire (ISI marked) of size 4.0 mm2], as required.
Providing 240 V, 16 A, 6 pin flush type socket outlet (plug) [without switch & plug top] on existing sheet metal switch board having Perspex / Bakelite top cover by screws, after making housing for socket outlet (plug), by cutting Perspex / Bakelite top cover and making necessary connections [with 'FR' PVC insulated (unsheathed), single core, 1.1 kV grade, copper (stranded) wire (ISI marked) of sizes 4.0 mm2 (for phase & neutral wires) & 2.5 mm2 (as Earth Continuity Conductor)], as required.
Providing 240 V, 6 A Piano Key type switch / bell push on existing sheet metal switch board having Perspex / Bakelite top cover by screws, after making housing for switch, by cutting Perspex / Bakelite top cover and making necessary connections [with suitable size 'FR' PVC insulated (unsheathed), single core, 1.1 kV grade, copper (stranded) wire (ISI marked)], as required.
Providing 240 V , 6 A, 3 pin flush type socket outlet (plug) [without switch & plug top] on existing sheet metal switch board having Perspex / Bakelite top cover by screws, after making housing for socket outlet ( plug), by cutting Perspex / Bakelite top cover and making necessary connections [with suitable size 'FR' PVC insulated (unsheathed), single core, 1.1 kV grade, copper (stranded) wire (ISI marked)] , as required.
Providing Earthing Stations , using Earth Electrode [made of 3 m long Medium Galvanised Mild Steel Tubes (as per IS:1239) of nominal bore 50 mm ]. 260 mm long G.I. Strip of size 50 mm X 6 mm (with 4 nos. 10 mm dia tap hole, bend to shape of pipe) to be welded at 100 mm below the top of tube for connection of Earth Strip. G.I. Funnel / Cap to be provided on top of the tube. Earth Electrode to be driven in the Earth Pit filled up with alternate layer of Charcoal and Salt. Earth Pit should be provided with suitable size Brick Masonry Inspection Chamber with removable RCC Cover (75 mm thick) with handle.
Interconnection of Earthing Stations by G.I. Strip (Hot Dip) of size 50 mm X 6 mm, with bolts, nuts, washers, etc.
Connecting the earth busbar to Earthing Station (with bolts, nuts, washers, etc.), including supply & laying of G.I. Strip (Hot Dip) of size 25 mm x 6 mm, using GI saddles or through PVC conduit of suitable size , including drilling holes.
Dismantling all existing old wiring, switch boards, MCB DBs, Junction Boxes, light fittings, fans, etc. and depositing the same at the store of HDC (Lock Store).
Jotshna Electricals
stage.html
html • 0.02 MB
finance_611730.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .