Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 0 LAL CHOWK GOW KADAL SRINAGAR KASHMIR MAISUMA LALCHOWK VILLAGE TOWN SRINAGAR CITY SRINAGAR SRINAGAR JAMMU AND KASHMIR 190001 INDIA | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.3 L
Closing Date
27 Dec 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr Aquaculture Engineer(XEN) Fisheries Department
Sulieman Complex Dalgate Srinagar
Electrification to Watch and Ward Hut at Bela Boniyar Uri District Baramulla
2021_ASH_154127_2
Short Term E-NIT No 39 of 2021-22 dated 18-12-202
Open Tender
Electrical Works
Item Rate
15 days
Bela Boniyar District Baramulla
Please refer Tender documents.
6 documents required · 6 mandatory
₹200
Revenue Head 0405 Fisheries in Goverment Treasury
Exempted
28 Dec 2021
20 Dec 2021
28 Dec 2021
20 Dec 2021
27 Dec 2021
20 Dec 2021
90 days
Amount
Providing/Laying& Fixing of
PVC channels of different sizes with its allied items for its fixing on the wall.
PVC conduit pipe 25mm dia with its allied items i.e. PVC bend, junction box, cliffs for its fixing over the surface or recessed into the wall as directed
Wiring for lighting points using multi standard copper wire single core 2x1.5 sq mm Polycab or Havells brand ISI marked through PVCchannel/pipe including cost of supply & fixing of modular cover plate fixed on iron/PVC box with grid frame flush mounted 6A - 1 way switch modular Legrand or GM or Havells brand of approved colour cost of wire using 2x1.5sqmm from DB to first switch in sub-circuit complete unit with masonry work and reface the same but excluding cost of PVC pipe/channel.
Wiring for ceiling fan using multi standard copper wire single core 2x1.5 sqmm & 1x1.5sqmm Polycab or Havells brand ISI marked through PVC channel/conduit including providing modular frame cover plate fixed on iron or PVC box with grid flushed mounted 6A/10A one way switch. Fan DimmerLegrand brand ISI marked complete unit but excluding cost of PVC channel/conduit.
Wiring for switch socket outlet using multi standard copper wire single core Polycab brand ISI marked through PVC channel/pipe including providing modular cover plate fixed on iron or PVC box with grid frame flush mounted 16A/20A switch & socket Legrand or GM or Havells make and 2x4 sqmm & 1.5 sqmm multi standard copper wire from D/B to first socket outlet but excluding cost of PVC channel/pipe
2x4 sqmm & 1.5 sqmm
2x2.5 sqmm & 1.5sqmm (for inverter
Wiring for switch socket outlet using multi standard copper wire single core Polycab brand ISI marked through PVC channel/pipe including providing modular cover plate fixed on iron or PVC box with grid frame flush mounted 16A/20A switch & socket Legrand or GM or Havells make and 2x4 sqmm & 1.5 sqmm multi standard copper wire from D/B to first socket outlet but excluding cost of PVC conduict
2x 1.5 sqmm & 1X1 sqmm
2x 2.5 sqmm & 1X1 sqmm
Supply, installation, testing & commissioning of:
Angle or batten holder along with providing PVC block and LED lamp Philips or Havells or Syska brand.
Ceiling Fan 1200mm sweep Usha or Havells or Bajaj make including cost of required items for its fixing.
Bulkhead PVC material complete with fixture items for its fixing on the wall including providing LED lamps Havells or Phillips or Syska.
Single phase & neutral Trip Distribution Board single door made of sheet steel powder coated Havells/Anchor/Legrand/Schneider brand flushed on the wall.
12 way DB
Single Pole MCB 6A or 10A or 16A. Havells/Anchor/Legrand/Schneider brand.
Double Pole MCB rating 16A or 20A or 63A Havells/Anchor/Legrand brand as per site requirement and load.
Providing, fixing of electronic voltage stabilizer VGMW 200 + V-Guard or MicroTek or LivGuard equivalent to 2KVA capacity including providing input leads with plugs & complete cost of commissioning and testing on full load.
P/Fixing of 900 SH PST Exide Solar Hybrid Sine Wave UPS or MicroTek brand or Luminous brand including providing required accessories for its fixing with battery and tall type Inverter trolly of same brand but excluding cost of battery.
Providing & fixing of 12 Volt Battery Exide Solar Tubular (6 LMS) 150L or equivalent brand or MicroTek or Luminous or Amaron brand including cost of complete charging and testing on load along with warranty card.
Providing of earthing in electrodes having 40mm or 50mm dia G.I pipe 8 rft long embedded in a pit of 8’ deep after excavation of boldered soil and refilling with alternative layers of salt, charcoal and soft clay with providing G.I wire along with G.I strip (25x3) mm.
Providing and laying of overhead service lines by using two core wires having 16sq mm aluminium conductor Havells or Polycab made from LT pole
Providing/Fxing of Solar Plate Exide Brand PVC module-EIL 100 maximum power .100W Voltage maximum power VMP 18.18V current at max power (inp) 5.5A or equivalent to Microtek brand or Amaron brand incld cost of required fixture items for its fixing on the roof and with providing 4 sqmm 2 core copper wire from roof upto inverter
ESS ESS ELECTRICALS AND MECH WORKS
stage.html
html • 0.02 MB
finance_343034.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .