Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹14.8 L+₹1.3 L (9.82%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹15.9 L+₹2.4 L (17.8%)Rejected-Finance C 187 NIRMAN VIHAR DELHI 92 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹16.0 L+₹2.5 L (18.8%)Rejected-Finance 227 NEW GANESH VIHAR ADARSH MILL ROAD GHOSIPURA LASHKAR GWALIOR 474012 M P | GWALIOR | MADHYA PRADESH | 474012 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹16.3 L+₹2.8 L (20.7%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹24.1 L
EMD Value
₹48,200
Closing Date
6 Aug 2021, 6:00 pmClosed
GE AF TA GWALIOR
GE AF TA GWALIOR-474020
REPAIR/MAINT OF INTERNAL ELECTRIC FITTINGS AND FIXTURES IN WEST WING OF RUNWAY OF TECH AREA AT AF STN GWALIOR
2021_MES_458567_1
8900/1316/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TA Gwalior
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF TA GWALIOR
₹48,200
Yes
9 Sept 2021
10 Jul 2021
9 Aug 2021
10 Jul 2021
6 Aug 2021
30 Jul 2021
Amount
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc all as directed.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick hylam laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed at site for the following :
(a) One light/ Fan point controlled by one way switch.
(b ) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No-2.03 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :- Make : Havells/Finolex/Polycab
(a) One light/ Fan point controlled by one way switch.
(b ) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No-3.03 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
S&F switch piano flush type single pole one way 5 Amps 230 V complete all as specified and directed.
S&F switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose complete all as specified and directed.
All as per item No 5.00 above but 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) complete all as specified and directed.
S&F socket out let 3 pin, 5 Amps, 230 Volt multipurpose flush piano type complete all as specified and directed.
S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in repair lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge
Supply and fixing in repair 8 Watt Recess mounted fixed LED down light made of extruded aluminium housing and high power LED as light source with diffuser and driver complete all as specified and directed by Engr-in-charge. Make :- Havells CAT Part No SPARLEPROFIXDLR8W830MOD or equivalent in makes of Philips/Bajaj
Supply& Fixing in repairs LED Batten fittings 10 Watt complete with lamp & round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete . Model Wipro Garnet 10W , D531065 of Wipro or Equivalent in makes of of Philips/Bajaj
Supply& Fixing in repairs LED Batten fittings 20 Watt complete with round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete . Model Wipro Garnet 20W , D532065 of Wipro or Eq model of Philips/Bajaj/Havells
S&F ceiling rose surface backelet ISI marked , 2 to 3 terminal all as specified.
S&F in repair, DB sheet metal enclosure 4 way Single door SPN complete all as specified and directed. Make:L&T/Legrand /Havells/C&S
All as per item No-14.00 above but 8 way Double door complete all as specified and directed. Make:L&T/Legrand /Havells/C&S /ABB
All as per item No-14.00 above but 12 way Double door SPN. complete all as specified and directed. Make:L&T/Legrand /Havells/C&S /ABB
S&F in repair MCB SPN 10 to 40 Amps all as specified and rupturing capacity 10 KA, complete all as specified and directed. Make:L&T/Legrand /Havells/C&S /ABB
S&F in repair MCB single pole 5 to 16 Amps all as specified and rupturing capacity 10 KA complete all as specified and directed. Make:L&T/Legrand /Havells/C&S /ABB
S&F in repair, DB sheet metal enclosure 4 way TPN Double door for mounting MCB.complete all as specified and directed. Make:L&T/Legrand /Havells/C&S /ABB
Supply and Fix in repairs MCB TPN, 4 pole 40 Amps 415 Volts all as specified and repturing capacity 10 KA complete all as specified and directed. Make:L&T/Legrand /Havells/C&S /ABB
Supply and Fix in repairs MCB TPN, 4 pole 63 Amps 415 Volts all as specified and repturing capacity 10 KA.complete complete all as specified and directed. Make:L&T/Legrand /Havells/C&S /ABB
M&L for sub main wiring with two runs of 2.5 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/Multi stranded copper conductor drawn through existing PVC conduit/casing caping alongwith accessories fixed an surface/concealed in walls, ceiling, floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 2.5 Sqmm single core as earth continuity wire including taking down old existing submain wiring complete all as specified and directed. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor incl conduit will be messured and paid as one unit length only. Make:Havells/Finolex/Polycab
M&L for sub main wiring with two runs of 4.00 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/Multi stranded copper conductor drawn through existing PVC conduit/casing caping alongwith accessories fixed an surface/concealed in walls, ceiling, floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 4.00 Sqmm single core as earth continuity wire including taking down old existing submain wiring complete all as specified and directed. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor incl conduit will be messured and paid as one unit length only. Make:Havells/Finolex/Polycab
M&L for sub main wiring with two runs of 6.00 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/Multi stranded copper conductor drawn through existing PVC conduit/casing caping alongwith accessories fixed an surface/concealed in walls, ceiling, floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 6.00 Sqmm single core as earth continuity wire including taking down old existing submain wiring complete all as specified and directed. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor incl conduit will be messured and paid as one unit length only. Make:Havells/Finolex/Polycab
M&L for earthing in repairs complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick burried directly in grond earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.50 mtr and below nomal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electric plate No-5 conneced to earthing test point all as specified or indicated including testing on completion.
S&F in replacement 8 Watt LED bollard light with Opel acrylic diffuser and IP-65 protection including necessary concreat work complete all as specified and directed Make :- Havells Cat Part No CONEBL8WLED857SSYMTOPC or equivalent in make of CG/Philips
Supply and fixing in repairs 8 Watt ultra bright PL-L LED suitable for four pin lamp holder alongwith in built surge protection of 3KV complete all as specified and directed. Make:- WIPRO/Havells/Philips
Supplying, fixing in repair & testing decorative recess mounting 36 watt LED full out put luminaries suitable for Armstrong ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed. Make: Cat Part No Havells-VENUSNE02X2PLR18-48WLED830MOD Racess mounted 2x2 LED or equvlent Philips/CG
S&F in repairs moduler switch socket 6 Amps 2/3 pin combined 2 module, complete all aspsecified and directed.
S&F in repairs Modular Switch socket 6/ 16 Amps 2/3 Pin combined 2 module complete all as specified and directed.
S&F in repairs modular switch piano flush type single pole one way 6 Amps,1 module complete all as specifed and directed.
S&F in repairs modular fan regulator Step type 120W 2module complete all as specified and directed.
M&l for LED light fitting, 1x10 w bulk head luminaries, complete with all accessories and including connection up with twin core twisted flesible copper conductor cable with suitable size of 230v, 50 HZ including taking down existing unserviceable light fitting comple all as specified and directed. MAKE: CG LBHN10CDL / Philips/Bajaj
Supply and fixing in repairs Plastic body exhaust fan 250 mm sweep AC, 240 volts fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable including provn of hole and aluminium frame etc for fixing the fan as required at site complete. Make :Orient / Crompton/ Havells/Bajaj
S&F in repairs recess mounting LED panel 12 W 160mm X 160mm luminaire white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission acrylic cover.Make: Bajaj LED Squadra 12 W of Bajaj or eqvt in Wipro/CG
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 60 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :- Havells Model No JETAQUANTOPLUSFLP60WLED757SYSMLENS/Philips/Wipro/Bajaj
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 30 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :- Havells Mode No JETAQUANTOPLUSFLP30WLED757SYSMLENS or equivalent in make of Philips/Wipro/Bajaj
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 30 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :- Havells Model No ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC or equivalent in Philips/Wipro/Bajaj or equivalent others make as specified.
keerti enterprises
M/S KAPIL CONSTRUCTION CO
M/s KKPARASHAR
M/s Yashika Enterprises
m/s varsha traders
M/S DHARMENDRA SINGH TOMAR
Achal Construction
M/S STEAD FAST
AUTOMATION AND SWITCHGEAR CONTROL
M/s Anupam Construction Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .