| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹2.6 L+₹13,830 (5.60%)Rejected-Finance | L2 | Rejected-Finance Quoted higher than L1. | |
| 3 | L3₹2.6 L+₹16,320 (6.61%)Rejected-Finance VILL BARAKURA P O SATBANKURA DIST PASCHIM MEDINIPUR PIN 721253 | SATBANKURA | PASCHIM MEDINIPUR | WEST BENGAL | 721253 | L3 | Rejected-Finance Quoted higher than L1. |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
28 Jun 2024, 1:00 pmClosed
University Engineer, C.U.
Office of the University Engineer Darbhanga Building, 87/1 College Street Kolkata- 700073, University of Calcutta.
S.I.T.C OF AIR CONDITIONER MACHINES FOR THE LAB OF PROF PRITHA BHATTA -CHARYA,DEPT OF ENVIRONMENTAL SCIENCE,PROF ALOKE GHOSH,DEPT OF BIOCHEMISTRY AND PROF PARTHIB BOSE OF ZOOLOGY DEPT. WITH ALL RELATED WORKS, UNIVERSITY OF CALCUTTA.
2024_CU_697030_1
E-tender/Eng/EQ- 49 /24-25
Open Tender
SUPPLY OF ELECTRICAL GOODS/EQUIPMENTS
Item Rate
15 days
BALLYGUNGE SCIENCE COLLEGE CAMPUS, C.U.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹7,000
13 Nov 2024
20 Jun 2024
1 Jul 2024
20 Jun 2024
28 Jun 2024
20 Jun 2024
Amount
SITC of 3star rating split air conditioner machine with R 32 gas incl.remotecontroller of folowing capacity suitable for operation on 230v +/- 10% volt50Hz,single phase ac supply with air cooled evaporator with copper coil fan & fan motor,air cooled condenser with copper coil,hermatically sealed rotary compressor,propeller fans, controls ,control panels incl wiring,necy.power cable connection from unit to power socket,refrigerant pipe of appropriate size between indoor & outdoor unit upto 3 mtr length[ both suction& delivery,incl gas charging complete as reqd,1.5TR [Make: (Hitachi/Daikin/Bluestar,Voltas}or equivalent.Inverter type
Providing & fixing copper pipe thickness with itrile rubber insulation notless than 0.6 mm& suitable size as required for supply& return refri -gerant with suitable insulation for above Acs as per specification of manufacturer complete in all respect as required[in excess of 3.00 mtr length /Machine1/4"[OD-6.35mm][HS code 7411 & IS 8119]
Supplying & laying 20mm dia ISI marked PVC flexi ble pipe along with acce-ssories on surface of the wall to drain out condensed water from indoor unit as required..[Thickness 5-10mm dia 3inch]
S&F factory fabricatedM.S structure for resting/ Placing of 1.5TR capacity split A.C outdoor unit on existing bldg. & fixed by MS fastner.
S&F4C flexible copper cable of size 4sq.mm,from indoor to outdoor unit incl .connection, commis -sioning testing etc as reqd.[ Polycab/Havells]
Hire & labour charges for shuttering with centering &necy. Staging upto 4mtr using approved stout props &thick hard wood planks of apprdthickness with reqd.bracing for concrete slab,beams & coloumns,lintels curved or straight………works (upto roof of G/F)When the height of a particular floor is more than 4mtr the equivalent flr height shall be taken as 4mtr 7 extra for works beyond the initial 4mtrshall be allowed under 12(e) for every 4mtr or part thereof.extra forstaging beyond 4mtr in any floor.(H=12mtr,B=2mtr,L=1.5mtr) Vol=36cum
Dismantling the existing electrical installation ( AC machines etc)As per WB Govt labour rate)
ELEKTRO DYNAMIC
SUSANTA GHOSH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .