| 1.00 | Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. | 240 | Cum | 450 ₹1,08,000 | 700 ₹1,68,000 | 250 ₹60,000 | 150 ₹36,000 Lowest |
| 2.00 | Excavation in trenches n exc 1.5 m wide & n exc 1.5 m depth; for foundation etc and getting out in hard/dense soil complete all as specified and directed. | 294.3 | Cum | 306 ₹90,055.8 | 320 ₹94,176 | 300 ₹88,290 Lowest | 300 ₹88,290 Lowest |
| 3.00 | M&L for cement concrete 1:4:8 type D-2 (40 mm graded stone aggregate) as in foundations, filling & mass concrete complete all as specified and directed. | 27.2 | Cum | 3,969 ₹1,07,956.8 | 4,500 ₹1,22,400 | 3,500 ₹95,200 Lowest | 4,200 ₹1,14,240 |
| 4.00 | M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in foundation, incl rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs under reamed piles and mass concrete complete all as specified and directed. | 56 | Cum | 8,100 ₹4,53,600 | 8,500 ₹4,76,000 | 7,200 ₹4,03,200 Lowest | 8,100 ₹4,53,600 |
| 5.00 | M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. | 14.5 | Cum | 8,100 ₹1,17,450 | 9,000 ₹1,30,500 | 7,200 ₹1,04,400 Lowest | 8,200 ₹1,18,900 |
| 6.00 | M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed. | 8 | Cum | 8,280 ₹66,240 | 9,000 ₹72,000 | 7,200 ₹57,600 Lowest | 8,200 ₹65,600 |
| 7.00 | M&L for formwork to sides of flat concrete foundations, footings, based of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter rough finished surfaces complete all as specified and directed. | 346.75 | Sqm | 540 ₹1,87,245 | 400 ₹1,38,700 Lowest | 400 ₹1,38,700 Lowest | 450 ₹1,56,037.5 |
| 8.00 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc Square/ Rectangular, rough finished surfaces of concrete complete all as specified and directed. | 265.5 | Sqm | 540 ₹1,43,370 | 500 ₹1,32,750 | 400 ₹1,06,200 Lowest | 450 ₹1,19,475 |
| 9.00 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surface complete all as specified and directed. | 105 | Sqm | 540 ₹56,700 | 600 ₹63,000 | 400 ₹42,000 Lowest | 500 ₹52,500 |
| 10.00 | S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. | 5,945 | Kg | 117 ₹6,95,565 | 92 ₹5,46,940 Lowest | 98 ₹5,82,610 | 135 ₹8,02,575 |
Tender Value
₹49.3 L
EMD Value
₹98,660
Closing Date
19 Sept 2025, 6:00 pmClosed
GE(S)BANGALORE
GE(S)BANGALORE
SPECIAL REPAIR TO BOUNDARY WALL APPROX 250 MTRS AT OLD MH LINE OF 56 COY ASC (SUP) TYPE G OF AGE B/R (CENTRAL) AND PROVN OF VISITORS ROOM WITH ATTACH TOILET AND DESK ROOM AT RMS OF AGE B/R (SOUTH) UNDER GE (SOUTH) BANGALORE
2025_MES_726978_1
8948/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE(S)BANGALORE
₹98,660
Yes
24 Sept 2025
21 Aug 2025
22 Sept 2025
21 Aug 2025
19 Sept 2025
5 Sept 2025
Amount
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide & n exc 1.5 m depth; for foundation etc and getting out in hard/dense soil complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (40 mm graded stone aggregate) as in foundations, filling & mass concrete complete all as specified and directed.
M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in foundation, incl rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs under reamed piles and mass concrete complete all as specified and directed.
M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for formwork to sides of flat concrete foundations, footings, based of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter rough finished surfaces complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc Square/ Rectangular, rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surface complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F mild steel TMT bars 6mm to 8mm dia and over upto and incl 10 mm dia, cut to length, bent to shape required, incl cranking, bending spirally for hooping for in stirrups, spaces and binders and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F mild steel TMT bars 5mm dia and over upto and incl 10 mm dia, cut to length, bent to shape required, incl cranking, bending spirally for hooping for in stirrups, spaces and binders and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for Precast cement concrete type C1 1:3:6 block masonry with solid blocks exc 10cm in width & setting in CM 1:6 complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
Removing building materials (Debries) to a distance of not exc. 5.0 Km (1 Metric tonne = 1 Load and One Cum = 1735 Kgs) out side MD Land Complete all as directed.
M &L for providing Broken glass coping on top of walls in cement mortar 1:3 complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 incl finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of cement primer complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) exc 250 m but n.exc 500 m and depositing where directed.
S&F mild steel hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling bolting for riveting etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S & F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including, securing or tying at crossings with and provion of galvanised mild steel wire, staples or steel pin etc including dismantling the existing barbed wire, etc complete all as speecified and directed. Note:- Each line of wire shall be measured and paid.
M&L for preparation of new or previously untreated steel or iron surfaces exc. 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Spreading and levelling in layers not exceeding 25 cm thick and well ramming including watering as required complete all as specified and as directed.
M & L Plain Cement Concrete 1:4:8 Type D-2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete complete all as specified and as directed.
M & L Reinforced Cement Concrete 1: 1 1/2 :3 (Nominal Mix) Type A-1 using 20 mm graded crushed stone aggregate in foundations including rafts, footings and mass concrete complete all as specified and as directed.
M & L Reinforced Cement Concrete 1:1 1/2 :3 (Nominal Mix) Type A-1 using 20 mm graded crushed stone aggregate) in columns complete all as specified and as directed.
M & L Reinforced Cement Concrete 1:1 1/2 :3 (Nominal Mix)Type A-1 using 20 mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
Reinforced Cement Concrete1:1 1/2 :3 Type A-1 using 20 mm graded crushed stone aggregate) in slab supported on walls and beams and shelves like complete all as specified and as directed.
Reinforced Cement Concrete1:1 1/2 :3 Type A-1 using 20 mm graded crushed stone aggregate) in chajjas complete all as specified and as directed.
Form work to sides and soffits of suspended slab for fair finished surfaces of concrete complete all as specified and as directed.
M&L treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified.
M&L Hardcore broken stone of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed
M & L 75 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded crushed stone aggregate) in sub base of flooring complete all as specified and as directed.
M & L 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) in floorings including finishing the surface even and smooth using without extra cement complete all as specified and as directed.
S&F non-skid coloured ceramic joint free rectified tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed of 15 mm thick in CM 1:6 etc complete all as specified and as directed.
S & F ultra charged Vitrified coloured ceramic tiles ( light shade) 8-9 mm thick ( Square/rectangular) polished area of each tiles not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white /coloured cement to match over a screed bed of 15 mm thick in CM 1:6 etc complete all as specified and as directed.
S & F ultra charged Vitrified coloured ceramic tiles ( light shade) 8-9 mm thick ( Square/rectangular) polished area of each tiles not exc 0.36 sqm in skirting etc set and jointed in neat cement slurry and pointed in white /coloured cement to match over a screed bed of 10 mm thick in CM 1:4 etc complete all as specified and as directed.
M&L for glazed coloured ceramic tiles 300x450 mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in coloured cement to match including 10 mm thick rendering in cement mortar 1:4 etc complete all as specified and as directed.
M&L 18-20 mm thick Granite black colour including rounding edges to exposed portion as in platforms for wash hand basin / sink (table, rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like laid in cement mortar (1:4) incl pointing in white cement (1:2) using mable dust with admixture of pigments to match with shade granite including cutting for securing of slab,complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished smooth and even without using extra cement.
M&L for rendering 5 mm thick CM 1:4, over 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound complete all as specified and as directed .
M&L for rendering 5 mm thick in ceiling on fair faces of concrete surfaces in cement mortar 1:3 and finished smooth and even without using extra cement.
Supply only liquid water proofing compound complete all as specified and as directed.
S&F Powder coated anodised aluminium frame, for door, windows, ventilators runner & packing with rubber gasket etc, with one or more rebates including joinning cleat for rebates including joining cleats for fixing etc, complete all as specified & directed by Engineer-in-Charge.
S&F 4.0 mm thick figured glass, pin head type and glazing with aluminium beading & rubber gasket in each panes in square n.exc 0.5 sqm in each pane in louvers complete all as specified and as directed.
S&F Powder coated anodised door shutter aluminium section nex weight 0.55kg Per/RM including necessary jointing cleats glazing clips, rubber neoprene handles 2Nos each door hinges alumn anodised snapveding screws etc..Complet all as specitied
S & F framed work such as grills, gratings etc. with ends of bars shouldered or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165.
S&F solid door frame of size 50 x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification & drawing complete all as specified and as directed.
S & F factory mode solid PVC moulded door shutter,28 to 30mm thick (stiles), wht 2,4 ot 6 raised panel desing with 3mm thick Moulded PVC Sheet on the front face & 2mm plain colout PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
M & L for powder coated Aluminium windows of three tracks outer frame,top,side section ,bottom frame( track) with guide track of size 92.5x31x1.50 mm with sliding window shutter 2 nos with glass and one nos with wire mesh9 total 3 nos shutter) from top and side section bottom section with wheel track and inner locking section of size 40x18x1.5 mm including glass 4 mm thick and aluminium wire cloth 0.45 mm nominal dia wire and average width of aperture 1.40 mm complete all as specified and directed
S&F 150 mm long aluminium anodised barrel tower bolts and extruded section and fixed complete all as specified and as directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed .
S&F mild steel butt hinges 75 mm, medium weight cold rolled and fixed complete all as specified and as directed.
S & F in repair of CPVC pipes 25mm Incl. SDR 11 Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S & F in repair of CPVC pipes 20mm all SDR 11 Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S & F 20mm brass elbow
S & F 20mm brass Tee
S & F 20mm brass male threaded adaptor
S & F 20mm brass female threaded adaptor
S & F 20mm brass tank adaptor
S & F 15mm brass elbow
S & F 15mm brass Tee
S&F 15mm dia stop vlave cast copper alloy screwed down high pressure with crutch or buterfly handle chromium plated screwed both ends for iron pipe or unions and fixed for 15mm bore pipe concealed type complete all as directed.
S&F 75mm dia PVC (SWR) floor/Nahani trap, plain with CP grating including solvent cement complete all as specified and as directed.
S&F 110mm dia PVC (SWR) 'P' trap complete all as specified and as directed.
S & F 110mm dia PVC (SWR) bends with oval access door
S & F 110mm dia PVC (SWR) bends
S & F 75mm dia PVC (SWR) bends with oval access door
S & F 75mm dia PVC (SWR) bends
S & F 110mm dia PVC (SWR) reducers
S & F 75mm dia PVC (SWR) vent cowls
M&L for 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
M&L for 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position complete all as specified
S&F 20 mm bore Ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete, all as specified.
S&F vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specifed and as directed.
S&F plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specifed and as directed.
S&F PVC low level flushing cistern 10 ltr capacity, valveless, syphonic action type with inlet, ball valve float and handle incl brakcet and flush pipe 32 mm dia complete all as specifed and as directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.. (Cat Part No of Cera F8030105 AB or equivalent in parryware/hindware/prayag)
S&F vitreous china trough type wash hand basin, white, size 550 x 400 mm including one number brass CP waste coupling, waste pipe 32 mm dia complete all as specified and directed.
S & F 15mm dia fancy pillar taps cast copper alloy with capstan heads, chromium plated, screwed down high pressure without lettered 'HOT' or 'Cold" with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
S&F brass CP 15 mm bore two way bib cock, quarter turn with wall flange and aerator, complete all as specified and as directed.
S&F 15mm dia fancy type chromium plated angle valve screwed both end for iron pipe or for unions , high pressure with long shank & cup (concealed type) having crutch handle complete all as specified and as directed by Engineer-in-Charge.
S&F PVC connections 15mm size with PTMT nuts of length 450mm all as specified.
S&F Soap dish, any type, fixed to plugs with chromium plated brass screws
M&L for newly plaster surface of walls and applying two coats of oil emulsion distemper over a coat of primer over 1 mm thick wall care putty, including stopping of nail holes, filling of cracks, etc and cleaning all window panes from splashes / droppings, complete all as specified and directed.
M&L for newly plastered surfaces of Wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm incl all necessary safety norms to the workers all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coat of oil emulsion, distemper over a coat of primer complete all as specified and as directed.
M & L two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer over 10cm in width or girth not otherwise described after preparation of new or previously untreated steel surfaces complete all as specified and as directed.
M & L 75 mm thick PCC (1:3:6) type C1 using 20 mm graded stone aggregates as in plinth protections finishing the surface even and smooth without using extra cement complete all as specified.
M&L for cleaning the plastered/concrete surfaces with wire brushes and applying water proofing treatment as under: (a) Apply bitumen primer at the rate of 0.27 litre per Sqm as per IS 3384-1986 and bonding bitumen of VG-10 @1.20 Kg per Sqm. (b) APP modified water proofing memebrane as per IS 16540/16532-2017, 3mm thick and weighing not less than 3.80 kg per Sqm reinforce polyster/HMHDPE matt black finish over compatible primer/bonding bitumen and finish the top surface with bituminus aluminium paint @0.10 Ltr per Sqm complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil inc. Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance.
M&L 100 mm thick PCC 1:4:8 type D-2 using (40mm graded crushed stone aggregates) as in sub base etc complete all as specified & directed
M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as approved by GE and as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/ shape, made by table in vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc complete all as specified and as directed.
M&L PCC 1:2:4 Type B-0 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
Supply and laying 20 mm GI pipe fitting tubes medium grade galvanished with all fittings complete laid in trenches Complete all as specified and as directed by Engr-In-Charge.
S & F of float valves of size 20 mm and as reqired at site as complete brass fitting with rod and plastic ball Complete all as specified and as directed by Engr-in-in Charge.
S & F gun metal gate valve with inner wheel head, screwed both ends in iron pipe and fixed of Size 20 mm Complete all as specifed and as directed by Engr-In-Charge.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point all as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm x 4 core complete all as specified and directed by Engr-In-Charge.
M&L for sand cushioning in trenches for bricks of u/g cable with coarse sand laid dry in trenches with uniform thickness complete all as specified and as directed by Engr-In-Charge.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection all as specified and directed Complete all as specified and as directed by Engr - In - Charge.
M&L for for PCC 1:2:4 Type B-1 using 20mm graded stone aggregate in forming channel, benching inside manholes (1/2 or 3/4 section) in manholes and as in copinf incl. necessary formwork etc complete all as specified and as directed.
M & L for Precast reinforced cement concrete 1:2:4 Type B-1 using 20mm graded stone aggregate as in cover slab for manholes set in CM 1:4 complete all as specified.
M&L 15mm thick rendering in CM 1:4 mixed with WPC on fair faces of brick or concrte surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Extra for forming fair finished channel or drain of 30cm inner girth in cement concrete using extra cement complete incl. forms, moulds mitred /stopped ends etc.
M&L for PCC 1;3:6 Type D-2 using 40mm graded stone aggregate for concrete bed to 150mm dia pipe incl. packing under and haunching against the sides of pipe after they are laid and tested complete.
Supply and laying 200mm internal dia DWCPE SN-8 pipes conforming to IS-14930 Part-II/IS 16025 Part-24 laying incl. all necessary work, cutting, jointing and fixing as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 Type B-1 smooth finished and reforming benching complete all as specified.
M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheathed cable with multistandred copper conductor conforming to IS: 694:1990 (for Phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade with ISI mark of appropriate size with all accessories laid in wall/ ceiling/floor etc, concealed with GI flush in box/terminal boxes of sutaible size, including front plate for mounting of modular switch/ socket and combined cover plate with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and flush in box and making good the distributed surfaces matching with existing complete all as specified and as directed for following- One light/ Bell/ fan point controlled by one switch
All as per Item No 113 above here in before but for Modular type Socket 6/10 Amp of two module in independent board, 230 volts complete all as specified and directed by Engr-In-Charge.
All as per Item No 113 above here in before but for Modular type Socket 6/10 Amp of two module on same board, 230 volts complete all as specified and directed by Engr-In-Charge.
All as per Item No 113 above here in before but for Modular type additional light / fan point on the same switch circuit mounted on same switch board controlled with separate switch, 230 volts complete all as specified and directed by Engr-In-Charge.
All as per Item no 113 above here in before but with 2.5 sqmm PVC insulated FRLSH unsheathed cable with GI Flush in box for modular switch/ socket 16 Amps of sutaible size as required with front plate for mounting of modular switch/ socket and combined cover plate of as required at site complete all as specified and as directed by Engr-in-Charge.
S&F for modular switch piano, flush type single pole, one way 16 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
S&F for Modular type Socket 6/16 Amp two way of 230 volts complete all as specified and directed by Engr-In-Charge.
S&F for modular switch piano, flush type single pole, one way 5/6 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
S&F for Modular type Socket 6/10 Amp of two way point complete all as specified and as deirected by engr in charge
S&F Fan Regulator step type 120W modular type Complete all as specified and as directed by Engr-In- Charge.
M&L ceiling rose surface bakelite 65x50 mm two to three terminals.complete all as specified and as directed by Engr-In-Charge.
S&F MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, SPN 8 way with 200 Amps rated bus bar , 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including complete all as specified and as directed complete all as specified and as directed by Engr-In-Charge.
Supply and fixing MCB SPN 40 Amps, 240 Volts complete all as specified and as directed by Engr-In-Charge.
Supply & fixing MCB SP 06-40 Amp, AC, 240 volts, complete all as specified and as directed by Engr-In-Charge.
Supply and fixing surface & wall mounted LED batten 4feet with extruded aluminium housing and robust construction 20 W system lumen including flexible copper 2 core wire from tube light fitting to ceiling rose required length with all accessories all as specified and directed by Engr-in-Charge.
S&F LED weather proof bulk head light fitting of shape and size as per site requirment of wattage upto 10 watt light fitting with mounting clamp, LED driver holder, LED lamps etc including connecting up to in celling rose complete all as specified and as directed by Engr-in-Charge.
Supply and fixing surface & wall mounted LED batten 2 feet 10 W with luminious efficacy not less than 100 lumen/watt including flexible copper 2/3 core wire from tube light fitting to ceiling rose with mounting provisions and all accessories with color of light warm white/cool day light as reqd at site complete all as specified and directed by Engr-in-Charge.
Supply and fix of ceiling fan 1200mm sweep with BLDC electric motor having star rated service wire 6.0 cubic meter per minute /watt, single phase with operating voltage range 140 to 285 volts BEE 5 star rated including mounting arrangement , 3 core flexible copper conductor cable up to ceiling rose , down rod suitable size length etc complete all as specified and directed by Engr in Charge.
Supply and PVC Body sound proof Exhuast fan 250 mm size with single phase 230 Volt 1200 RPM with louvers, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed by Engr-in - Charge
M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified & as directed by Engr-In-Charge.
PRAGATHI BUILDERS (BID ID -3429543)
Srisrinivasaenterprises (BID ID -3420557)
GIRISH M C (BID ID -3421053)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .