Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC SREE COLONY BAGDOGRA PO BAGDOGRA DIST DARJEELING WB | L1 | Accepted-AOC Accepted | |
| 2 | L2₹47.2 L+₹86,714.06 (1.87%)Rejected-Finance C O UTTAM BANIK HAIDERPARA OPPOSITE TO WEST BENGAL REPRESENTIVE REST HOUSE P O HAIDERPARA SILIGURI 06 | JALPAIGURI | WEST BENGAL | 734006 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹47.8 L+₹1.5 L (3.28%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹48.2 L+₹1.9 L (4.07%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹48.2 L+₹1.9 L (4.20%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
1 Oct 2022, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
CONSTRUCTION OF TWO STORAGE SHEDS AND CERTAIN SPL REPAIR AND REVENUE AND MINOR WORK AT SEVOKE STN UNDER GE SEVOKE ROAD
2022_MES_546259_2
GE/SEV/29 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹92,000
Yes
21 Oct 2022
15 Sept 2022
3 Oct 2022
15 Sept 2022
1 Oct 2022
23 Sept 2022
16 Sept 2022 - 19 Sept 2022
Amount
Surface dressing n exc 15cm deep getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/loose type soil getting out complete all as specified and directed
M&L for PCC 1:3:6, type C-2 (using 40 mm graded crushed stone agg) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
Use and waste formwork to sides of concrete foundations, plint beams for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) 1:2:4 type B-1 (20 mm graded crushed stone aggregate) in Foundations,footings, foundation beams; bases for columns, etc.; and mass concrete complete all as specified and directed. (Note: Reinforcement and form work shall be measured and paid separately).
Use and waste formwork to sides and soffits of floor or roof beams, beam hunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams for rough finished, flat surfaces etc complete all as specified and directed.
M&L RCC 1:2:4 type B1 (using 20 mm gradded crushed stone aggregated) as in lintels upto 1.5m clear span and lintel band, roof band, plinth courses string courses, lacing courses, parapets and railling upto 60 cm in height coping, kneelers, apex stones, bed plates, water throughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Use and waste formwork to sides of pillars. posts. struts. piers. columns and stan- rchions for rough finished flat surfaces of concrete, square or rectangular complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping for rough finished flat surfaces) complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) 1:2:4 type B-1(20 mm graded crushed stone aggregate) as in columns, pillars ,piers, post and struts complete all as specified and directed. (Note: Reinforcement and form work shall be measured and paid separately).
M&L for Reinforced cement concrete (nominal mix) 1:2:4 type B-1(20 mm graded crushed stone aggregate) as in chajjas complete all as specified and directed. (Note: Reinforcement and form work shall be measured and paid separately).
M&L for RCC 1:2:4 type BI (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and coloumn in floors, roofs, landings, balconies, conopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required incuding cranking, bending spirally for hooping for columns, hooking ends and binding with and incuding mild steel wire (annealed), not less than 0.9mm dia or securing with clips complete all as specified.
All as per item No.14 above but 5 mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in each layer in soft/ loose soil complete all as specified and directed
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for 75 mm thick Sand filling under floors including watering and consolidation as in sand cushioning for interlocking paver blocks complete all as specified and directed.
M&L hardcore of broken stone or boulders of gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100mm thick PCC (1:2:4) type B-2 (using 40mm graded mechanically crushed stone aggregate) as sub base of flooring complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15mm thick screed bed or beding layer of cement motor 1:6 for fixing of stone complete all as specified and directed.
S&F mild steel screw bolts, 12mm dia (machine made) with hexagonal heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut, exceeding 15cm and not exceeding 22.5cm long complete all as specified.
M&L rendering 15mm thick in CM 1: 6 on fair faces of brick masonary walls finished even & smooth without using extra cement complete all as specified and as directed.
M&L for 20 mm thick rendering on fair faces of brick work in CM 1:4 in two layers of 10mm each using water proofing compound in top layer only including finishing the surface even and fair(WPC shall be measured and paid seperately) complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed.
M & L for preparation of new plastered surfaces of walls and applying three coat of white wash, complete all as specified and directed.
S&F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe 410 W Gde-E 250) Quality A complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc completed using ERW or induction butt wilded tubes confirming to IS 1161-1998 grade St - 240 complete all as specified and directed.
S&F rolled mild steel Roof trusses (framed), trussed, purlins, crane, gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc( Fe 410-W Gde-E-250) quality A Including preparation of surface and one shop coat of zinc chromate primer at contractors workshop before fabrication complete all as specified and directed by Engineer-in-Charge..
S&F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, with glazing bars, dovetailed or welded including one shop coat of zinc chrome primer complete all as specified and directed.
S&F 3mm thick sheet glass pin head type and glazing with oil putty in square not exc 0.50 Sqm in each pane complete all as specified and directed.
S&F factory made Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified in SSR Part I and directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
S&F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlines to steel trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
M&L for mild steel expanded metal cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel stapless supplied and fixed complete to wood or steel memberss n .exc 4 kg/sqm complete all as specified.
S&F 150mm dia half round PVC (SWR) pipes with rounded edges including accessories like bend T etc for eaves gutter complete all as specified and as directed.
S&F 150mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed
M&L PCC 1:3:6 type C-2 (using 40 mm gradded crushed stone aggregated) as in surface channels and drains complete all as specified and as directed.
Extra for forming fair finished drain or channel n exc 30 cm inner grith in cement concrete using extra cement including forms moulds mitred stopped end complete all as specified and as directed.
M&L 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection & including bitmen filler at joints paving finished even & smooth without using extra cement complete all as specified and as directed.
M&L for chequered cement concrete tiles 30cm x 30 cm x 25 mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry in floor with grey cement mixed with pigments to match with the colour of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for 10mm thick rendering on other than fair faces of brick or concrete surfaces in CM 1:3 mixed with water proofing compound @3% of cement, finished even and smooth without using extra cement complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep in soft/loose soil and getting out complete all as specified and as directed.
Excavating in post holes (or similar holes) in soft/ loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and as directed.
S&F rolled mild steel section including hollow section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates FE-290 Gde E-165. Complete all as specified and directed.
M&L for preparation new steel and iron surfaces of any description n. exc 10cm in width or grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed
S&F heavy duty Mild steel grating over drains of width 350-450 mm length upto 6m complete all as specified and directed.
M&L for vitrified heavy duty parking tiles 30cm x 30 cm x 12-15 mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry in floor with grey cement mixed with pigments to match with the colour of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L rendering 5mm thick in CM 1: 3 on fair faces of ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed.
M & L for preparation of new/old plastered surfaces of wall and applying 2-3mm thick wall care putty ,complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over and including a coat of primer complete all as specified and directed. .
M & L for preparation of new plastered surfaces of ceiling and applying three coat of white wash, complete all as specified and directed.
M&L for complete removal of existing treatment of wall by brooming down steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water etc applying two coats of oil bound distemper with roller over one coat of primer complete as specified and directed.
M&L for complete removal of existing treatment of wall by brooming down steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water etc applying two coats of antifungal exterior paint (of shade/colour as directed by GE) over one coat of primer all as per manufacture instruction including necessary scaffoldings etc complete as specified and directed.
M & L for preparation of old plastered surfaces of ceiling and applying one coat of white wash, complete all as specified and directed.
Dismantling floor hearth or wall tiling and stone slabs including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed
M&L 20mm thick granite slabs of any type (table rubbed and polished) on cooking platforms set and jointed in net cement slurry and pointed in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including necessary moulding at edges laid over and including 20mm thick cement mortor screed bed in cement mortor (1:6) complete all as specified and directed.
M&L for vitrified Non-skid ceramic tiles 8 to 10mm thick (square/ rectangular) area of each tiles n. exc 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
Taking down chowkats or frames, n.exc 1.5 sqm with shutters (Without taking off shutters from the frame)complete all as specified and directed.
S&F Anodised aluminum section powder coated in partition / frame for door, shutters, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing element of these items shall be deemed to be included in quoted rate.
S&F mild steel Framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe -290 Grade -E-165, complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connections including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down 20 mm bore steel water tubing and connections including cleaning re-fixing or removal to store complete all as specified.
Taking up or down 25 mm bore steel water tubing and connections including cleaning re-fixing or removal to store complete all as specified.
Cutting chases in brickwalls girth exc 10 cm but n exc 20 cm , pinning in making good to facings where required and pointing in cement mortar 1:3 for conceal water tubing etc and making good complete all as specified.
S&F 15 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified.
S&F 20 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified.
S&F 25 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified.
S& F in repair 15 mm bore stop cock/angle cock cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe complete all as specified and directed.
S& F in repair 15 mm bore bib tap cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe complete all as specified and directed.
S&F in repairs 15mm bore CP fancy type Health faucet with 1.5 meter long tube with CP wall bracket complete all as specified and as directed.
S&F PVC connection pipe 15 mm dia, 450 mm long with PTMT nut complete all as specified and as directed
S&F in repairs brass chromium plated, shower rose, 125mm size, complete all as specified and directed.
Roughening surfaces of existing roof treatment and taking out old APP membrane and removing from site including cleaning and washing down with water to remove dust etc complete all as directed.
M&L for providing, laying water proofing treatment over plastered surfaces of RCC roof shall be as under :- (a) The dried plastered surface of slab shall be painted with one coat of bituminous primer @0.4 liter/Sqm. (b) Over the primed surface a layer of APP based polymeric membrane minimum weight of 3 kg/sqm of approved manufacturer minimum 3mm thick, reinforced with polyster non woven fabric (weighing not less than 160gms/sqm) shall be laid by torch application method. The side over laps of membrane shall be minimum75mm and the end laps shall be minimum 100mm and sealing all overlaps and joints shall be done as per manufacturer's instruction. (c) The finished surface shall be given Aluminium paint @ 0.11 Kg/Sqm on APP as per manufacturer's instructions. Make:-M/S TEXSA INDIA LTD (MOPLY-FP) / M/S STP LIMITED (SUPER THERMOLAY) / IWL INDIA LIMITED (HYPERPLAS)/M/S Tiki Tar Danosa (India) Pvt Ltd (Hydro Stop)/M/s Supreme Bituchem India Pvt Ltd (Super Shield)
M&L for 20 mm thick rendering in CM (1:4) over RCC roof surface to receive roof treatment finished even and smooth without using extra cement mixed with water proofing compound as per manufacturers instruction (WPC shall be measured and paid separately).
M&L for 40 mm thick cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in roof padding finished even and smooth using extra cement complete all as specified.
S&F Cubical of size 0.60x0.60x0.675 mtrs (minimum) madeout from 19 mm thick plywood grade BWR including front facia PVC laminated, with wall supported at back, ply on three sides, resting below cooking platform. The cubical shall have three baskets (cutlery, cup saucer and thali) made out of stainless steel of grade 304 fixed with telescopic drawer channels and accessories. The internal surface shall be laminated with white colour complete all as specified and as directed. Make of plywood/laminates:- Green ply industries/ Century / Archid.
S&F Cubical of size 0.60x0.60x0.675 mtrs (minimum) madeout from 19 mm thick plywood grade BWR including front facia PVC laminated, with wall supported at back, ply on three sides, resting below cooking platform. The cubical shall have two baskets made out of stainless steel of grade 304 fixed with telescopic drawer channels and accessories. The internal surface shall be laminated with white colour complete all as specified and as directed. Make of plywood/laminates:- Green ply industries/ Century / Archid.
S&F 19 mm thick plywood grade BWR as in cabinet all as specified and as directed . Make of plywood : Green ply industries Ltd / Century / Archid
M&L 1.5 mm thick PVC laminates and fixed with approved Adhesive as per manufacturer instructions. Make:- Green ply industries Ltd/ Century/ Archid.
M&L 0.9 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer instructions. Make:- Green ply industries Ltd/ Century/ Archid.
S&F Kitchen cabinet hinges 2 hole full overlay complete as specified and directed. Make: Godrej/ Hettich/ Linc
S&F Aluminium anodised profile handle no protuding type and shall match the surface of cubical complete all as specified and as directed. Make: Godrej/ Hettich/ Linc
M&L for coloured 450x300x7 mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick cement mortar backing coat in CM 1:4 etc, complete all as specified and directed.
Demolition of cement concrete in ground floors (un-reinforced) and paving not exc. 15cm thickness (below or above ground level) including removing debris outside MD land complete all as specified and directed.
M&L for PCC 75 mm thick (1:4:8) type D-2 (40 mm graded crushed stone aggregate) as in sub base complete all as specified and as directed.
M&L for coloured Non-skid ceramic tiles 8 to 10mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 20mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed
M&L for preparation of new decorated surfaces of wall and applying two coats of weather proof exterior acrylic emulsion paint (of shade/ colour as directed by GE) over one coat of primer all as per manufacturer instruction including necessary scaffoldings etc complete as specified and directed.
Roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3 kg of cement per sqm complete all as specified.
M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified.
M&L for cement concrete of 1:3:6 Type C-1 using 20 mm graded crushed stone aggregate as filling of pressed steel frame, (lintel, copings, hold fast block etc) complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15mm thick screed bed of cement mortar 1:6 complete all as specified and as directed.
M&L for Brick work with fly ash bricks, as in half brick thick wall built in CM (1:4), complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
S&F Stop valve, 15mm bore cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, fancy type, chromium plate, with long shank and cup (concealed type) complete all as specified and directed.
S&F PVC (SWR) floor trap dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tined tacks, or galvanised wire stapless complete all as specified and as directed.
M&L for 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
M&L for 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of 1000 litre capacity double layer black in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed
S&F 32mm bore high density polyethylene pipes (LDPE) of pressure rating 6 Kgf / cm2, fixed to walls, ceiling or laid in floors etc, complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of size 300x150x250mm of M-25 grade cement concrete in position to the required line , level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete all as specified and as directed.
M&L for concealed point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor FRLS of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC rigid conduit (medium grade) with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per Item Sl No - 111 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.5 sqmm green in colour as earth lead for 5/6 A switch-socket point on independent board complete.
All as per Item Sl No - 111 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.50 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete.
All as per Item Sl No - 111 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.5 sqmm green in colour as earth lead for 5/6 A socket point with switch on same board complete.
M & L for Switch Socket combination 3 Pin, 5 Amp flush type universal, 240 volts, complete as directed.
M & L for Socket outlet 3 Pin, 5 Amp flush type universal, 240 volts, complete all as specified all as directed.
M & L for Switch Socket Combination 5 in 1, 3 pin, 5 and 15 Amp flush type universal, 240 volts, complete all as specified and as directed.
S&F piano switch single pole 5 Amp 230 Volt all as specified and as directed.
S&F ceiling rose ,surface bakelite 65mm x 50mm size with three terminals all specified and as directed.
S&F decorative box type fitting with LED tube 20 watt 4 feet with Al extrudedbatten luminaire for 230 volt AC complete all as directed by EIC.
M&L LED street light of capacity 40 watt in Aluminium PDC housing, with IP66 protection complete all accessories with frame and connecting PVC copper wire not exc 5 mtr complete all as directed.
S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed.
Supply & Fixing DB with sheet metal enclouser 240 volts, 12 way, SPN double door for MCB, including cutting chases for DB of reqd size and making good distrubed surface area complete all as specified and as directed.
Supply & Fixing MCB double pole (DP) 240 volts of capacity 32 Amp ,C curve, complete all as specifie and as directed.
S&F MCB, SP, 10KA, 415V, "C" curve, 06-32 A, ISI Marked complete all as directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position ) earth pit not less than 2.25 mtrs below normal ground level with the top edgeof the earth plate not less than 1.5 mtr (B.G.L.) & connected to galvanised iron wire 4 mm dia by means of bolts,nuts,checknuts & washer of galvanised iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation & earth work in any type of soil , 20 mm dia med grade galavinised steel tube for watering with one end fixed with cast iron funnel & wire mesh, 15 mm bore light grade galvanised steel tubing up to 7.5 mtr length for drawing earth lead including common salt , charcoal in alternate layers etc. complete all as shown in EP no 3 of SSR Part 1 & testing on complection incl taking down old unsv earthing complete.
Taking down carefully old unserviceable copper/aluminium point wiring (light,Exchaust fan, socket or power) complete incl fittings such as switches,ceiling roses, pendents, regulators,bells,sockets,tube light fittings etc, and making good disturbed surface of walls & floors etc complete all as specified and as directed.
Taking down old unserviceable Main Switch, DB's consisting of MCBs wooden/GI/MS sheet board etc for kept in store and for later use all as directed.
Taking down carefully unserviceable sub main wiring of any size/core/type including making good the disturbed surfaces all as directed.
S&F decorative box type fitting with LED tube 9 watt 2 feet with Al extrudedbatten luminaire for 230 volt AC complete all as directed by EIC.
Taking down ceiling fans/exhaust fan of any size,dismantling blades and removing fan and blades complete all as specified and directed. Note:- Ceiling fan should be deposited in MES store yard.
S&F energy efficient BLDC ceiling fan 230V, 1200 mm sweep without remote with all accessories and connecting up with the ceiling rose with required flexible wire of suitable size with ceiling fan complete all as specified and as directed.
Material and labour for concealed sub main wiring with two nos single core PVC insulated unsheathed multi strand copper conductor FRLS cable of size 6 sqmm and one no single core PVC insulated unsheathed multi stranded copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including rigid non-metallic ISI marked PVC conduit medium grade with all fittings and fixings accessories complete all as specified and as directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out excavated material for laying/ taking out pipe line, cables, etc in soft/ loose soil complete all as specified and directed
Supply and laying in trenches/wall LT UG XLPE insulated,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 sqmm 2 core including making necessary connections all as specified and directed.
Supply & laying in trenches clear sand for cushioning under cable 8 cm below and 15 cm above complete in level all as specified and directed by Engr-in-Charge. Note:- Punned thickness shall be measured.
Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
Supply and fixing GI pipe 40mm bore medium grade for cable protection complete all as specified and as directed.
Supply and laying in trenches/wall LT UG XLPE insulated,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 sqmm 4 core including making necessary connections all as specified and directed.
M/S DUTTA & DAS ENGINEERING CO.
Raj Enterprise
M S ALOK SAHA
TAPASH SAHA
SRI SURAJIT SENGUPTA
ASSOCIATED TRADING CORPORATION
SHRI JAYANTA GHOSH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .