Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹37.3 L+₹1.6 L (4.33%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹37.8 L+₹2.0 L (5.72%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹38.3 L+₹2.5 L (7.11%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | Rejected-Technical 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | - | Rejected-Technical not enlisted in required category |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
11 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ARJUN PATRO,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
Repair and Maintenance of multifunction meters, communication equipments and connected works including integration with Central Control Centre for establishment of centralised complaint management system under GE U Elect Supply Delhi Cantt10
2021_MES_459550_2
GE ELECT/D-52/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
1000 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹99,000
Yes
14 Sept 2021
22 Jul 2021
13 Aug 2021
23 Jul 2021
11 Aug 2021
30 Jul 2021
60 days
Amount
PHASE-I
Supply, Installation, Integration and Testing of HT CT operated Trivector Meter with the following specifications: • Meter Type: HT 3 Phase 3 Wire Electronic Tri vector Meter • Standard: IS 14697, IEC 62052-11, IEC 62053-22, IS 15959 • Accuracy: Class 0.5 • Voltage and Current rating: (i) Reference Voltage - 110 V, (ii) Basic Current - 5 A (iii) Maximum continuous current (Imax) - 10 A • Rated Frequency (variation) - 50Hz (±5%) • Power consumption: (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, ref frequency and ref temperature • Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height • Display in the event of Power Failure: Internal battery back-up for LCD display • Communication port: (i) Optical port for local communication (ii) RS 232 / RS 485 port with MODBUS • Energy recording - Unidirectional • Instantaneous parameters (30 Min) - Each Phase Current, Each Phase Voltage, Each Phase Power, Each Phase Power Factor, Each Phase Reactive Power, Power, Power Factor, Apparent Power, Reactive Power, Frequency • Load survey (30 Min) parameters - Energy, Apparent Energy • Daily Survey: Cumulative Energy, Cumulative Apparent Energy • Operating Temperature Range: -10degreeC to +55degreeC, 95% non-condensing RH
Supply, Installation, Integration and Testing of HT CT operated Net Meter with the following specifications: • Meter Type: HT 3 Phase 3 Wire Electronic Tri vector Meter • Standard: IS 14697, IEC 62052-11, IEC 62053-22, IS 15959 • Accuracy: Class 0.5 • Voltage and Current rating: (i) Reference Voltage - 110 V, (ii) Basic Current - 5 A (iii) Maximum continuous current (Imax) - 10 A • Rated Frequency (variation) - 50Hz (±5%) • Power consumption: (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, ref frequency and ref temperature • Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height • Display in the event of Power Failure: Internal battery back-up for LCD display • Communication port: (i) Optical port for local communication (ii) RS 232 / RS 485 port with MODBUS • Energy recording - Bidirectional • Instantaneous parameters (30 Min) - Each Phase Current, Each Phase Voltage, Each Phase Power, Each Phase Power Factor, Each Phase Reactive Power, Power, Power Factor, Apparent Power, Reactive Power, Frequency • Load survey (30 Min) parameters - Energy, Apparent Energy • Daily Survey: Cumulative Energy, Cumulative Apparent Energy • Operating Temperature Range: -10degreeC to +55degreeC, 95% non-condensing RH
Supply, Installation, Integration and Testing of LT CT operated Trivector Meter for LT bulk billing/gross solar generation with the following specifications: • Meter Type: LT 3 Phase 4 Wire Electronic Tri vector Meter • Standard: IS IS 14697, IEC 62052-11, IEC 62053-22, IS 15959 • Accuracy: Class 0.5 • Voltage and Current rating: (i) Reference Voltage - 415V (L-L) and 240V (L-N), (ii) Basic Current - 5 A (iii) Maximum continuous current (Imax) - 10 A • Rated Frequency (variation) - 50Hz (±5%) • Power consumption: (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature • Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height • Display in the event of Power Failure: Internal battery back-up for LCD display • Communication port: (i) Optical port for local communication (ii) RS 232 / RS 485 port with MODBUS • Energy recording - Unidirectional • Instantaneous parameters (30 Min) - Each Phase Current, Each Phase Voltage, Each Phase Power, Each Phase Power Factor, Each Phase Reactive Power, Power, Power Factor, Apparent Power, Reactive Power, Frequency • Load survey (30 Min) parameters - Energy, Apparent Energy • Daily Survey: Cumulative Energy, Cumulative Apparent Energy • Operating Temperature Range: -10degreeC to +55degreeC, 95% non-condensing RH
Supply, Installation, Integration, Commissioning and Testing of Field Remote Terminal Unit (FRTU/PLC) module for automatic meter reading of bulk energy meters including connecting all Trivector/Net meters (max 15 Nos) using RS485/RS232 cable. The module shall be of industrial grade, continuous duty, EMC compliant unit and act as a gateway for interfacing with energy meters to obtain metering data like current, voltage, kVA, kW, kWh, kVAR, pF, Hz etc on Modbus protocol via daisy chain or using RS232 cables and transmit the same to centralized control centre server on IEC-104 protocol through router/modem. The module shall have following configuration as minimum:- (a) Industrial grade min 64 MHz processor or controller with inbuilt memory for data backup in case of link failure (b) Integrated Ethernet port for program download/upload and online monitoring (c) Integrated RS 485 port for connecting Modbus Slaves with data transmission speed of 9.6 to 250 kbps (d) Immediate SMS message triggering in case of alarm with cause of alarm. (e) Supported Protocols IEC 60870-5-104, Modbus TCP/IP, Modbus client and server, FTP, SNTP, HTTPS, HTML (f) 8 Digital Inputs & 4 Digital Outputs (g) Cyber security as per IEC62351 (h) Operating Voltage Range 24 V DC, +/- 15% (j) Security Protocols IPsec and SSL/TSL (k) Conforming to IEC 61000-4-5, IEC 61000-6-2 & IEC 60068-2-27 (l) Protection Degree IP20 (m) Operating Temperature range -10°C to 55°C, Humidity upto 95% (n) Time synchronization with central server & surge voltage protection.
Supply, installation, configuration and testing of LTE router/modem, IP-67 rated, made of aluminium alloy for retrieving metering data from new/existing meter on Modbus/RS232 using RS485/RS232 cable and transmitting the metering to Central data control centre on IEC 104 protocol and having following configuration as minimum:- (a) CPU 580 MHz, (b) Flash memory 32 MB (c) RAM (DDR2) 128 MB, Built-in 64 KB cache (d) Communication Protocols - Modbus RTU/TCP to IEC-60870-5-104, Modbus master (e) Ethernet port RJ45, RS 232 / RS 485 (f) Security - Zone based firewall, VLAN, DMZ, HTTPS local and remote connection, SIM PIN (g) Routing - DHCP, static routing, port forwarding, traffic routing, static / dynamic DNS, DNS proxy, NAT, STP (h) Operating Voltage Range 24/48 V DC, +/- 15% (j) Operating Temperature range -40°C to 60°C, up to 95% RH (k) Dual 5½ U / 1¾ U Din Rail mountable (l) Dual SIM (Static IP / Normal) for two Service providers with Auto Switchover based on Health-check.
Supply, Installation, Integration, Commissioning and Testing of Firewall Gateway for network and web server protection, Intrusion Prevention System, Advanced Threat Protection, traffic scanning, having multifunction LCD module, integrated SSD, multi core intel processor complete with the specifications as specified below: (a) Web protection, control and protection, anti-malware, anti-spam (b) IPSec and SSL VPN for 200 user network with firewall protection (c) Dual VPN support with the help of dual static IPs for redundancy (d) Ethernet Gigabit ports – 06 Nos, USB – 03 Nos, HDMI – 01 No. (e) Gigabit SFP ports – 02 Nos for Fibre connectivity (f) UL and BIS certification, Cyber security compliance as per IEC 62443 (g) Open Protocol support (h) Metal housing, 1 U rack mountable (j) NTP Client/Server, Internet protocol security ESP Tunnel / ESP Transport (k) Operating Temperature Range: 0˚C to 40˚C (l) Aux Power Supply 100V AC - 240V AC, 50-60 Hz
M&L for Integration of metering data points with central data server at main control centre through PDS for display, report generation for billing through central server. All metering data received from field devices/meters/modems shall be integrated on central server based on e-terra scada software to the full satisfaction of Engineer-in-Charge complete all as directed. Note:- Any technical support required during integration services shall be provided by M/s GE T&D being OEM of the System.
M&L for Polycarbonate Box of size 200x300x100mm suitable for indoor/outdoor use, wall/panel mountable type including, din rail, cable-entry/routing arrangement, locking arrangement and connectors complete all as specified and directed.
Supply, installation and commissioning of DC power supply converter module suitable with input voltage range 100V AC to 260V AC and stable output 24V DC +/- 2% supply of 1.5 Amp rating, din rail mountable, complying IEC 60068-2-27, having IP 20, operating temperature range -10degC to 60degC complete all as specified and directed.
Supply, installation and commissioning of MCB DP 6 Amp rating, 230V AC 50 Hz, complying IEC 60898-1, IP 20, operating temperature range -10degC to 60degC complete all as specified and directed.
PHASE-II
AMC of metering system with communication equipment including monthly recharge / bill payment of dual SIM cards per modem complete all as specified and directed for first year. Note:- Date of commencement of AMC shall start from next day after completion of Phase-I. Maintenance of the Metering & Communication Equipments is covered under two year Defect Liability Period.
AMC of metering system with communication equipment including monthly recharge / bill payment of dual SIM cards per modem complete all as specified and directed for second year. Note:- Date of commencement of AMC shall start from next day after completion of Phase-I. Maintenance of the Metering & Communication Equipments is covered under two year Defect Liability Period.
NOTE :-(i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
ALLIED CONSTRUCTION
mayur enterprises
RUHI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .