| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.2 L
Closing Date
13 Sept 2021, 4:00 pmClosed
Estates Officer
Estates Division SKUAST Jammu Chatha
Repair Renovation of old Registrar Office Scientists Lodge at Guest House Railway Road Jammu
2021_SKUST_136443_6
AU/Estates/21-22/16 dated 23-08-2021
Open Tender
Civil Works
Item Rate
120 days
Guest House Railway Road Jammu
Please refer tender documents
4 documents required · 4 mandatory
₹1,000
Yes
Assistant Comptroller Estates SKUAST Jammu
Exempted
29 Sept 2021
26 Aug 2021
14 Sept 2021
26 Aug 2021
13 Sept 2021
26 Aug 2021
Amount
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Renewal of old putty of glass panes (length) .
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of thickness 4 mm.
Regrading terracing of mud phaska covered with tiles or brick, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand) including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per directions of Engineer-In-Charge.
Providing and fixing brass curtain rods of wall thickness 1.25mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.
20 mm diameter.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work.
Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing Stainless Steel A Isis 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink with drain board
510x1040 mm bowl depth 250 mm.
Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :
Flat back wash basin of size 550x400 mm.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe
32 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminum angle frame with CP brass brackets and guard rail complete fixed with 40mm long screws, rawl pluggs etc. complete
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
15 mm dia. nominal bore
20 mm dia. nominal bore
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Cleanliness of existing tiles by way of rubbing with chemical detergent complete.
Repair to existing kota stone flooring by way of fixing of new stones.
Engagement of welder for repairing of old window chowkhats and hooks etc.
01 weldar for 05 days
01 welding set for 05 days
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm.
Providing and fixing of the following sanitary items with necessary fittings complete item
Soap dish of nominal size (CP)
PVC connection
CP gratings (100 mm)
CP long body bib cok of approved make (15 mm nominal bore)
C.I. waste coupling 30 mm of 79 mm length x 77 mm breadth
Providing & fixing of shower of nominal dia and approved make.
C.P. Angle Valve (15 mm) nominal bore
Providing and fixing of the following G.I. accessories/fittings and making G.I. connection with manholes.
Ball valve of nominal dia (20 mm)
Providing and fixing:-
PVC pipe (100 mm nominal dia)
PVC plain bend (110 mm)
Providing and fixing in position PVC water tank of Sintex or Equivalent brand with lockable cover including connection of inlet-outlet over flow and cleaning pipes including cost of GI pipe , G.I fittings complete item of nominal capacity
Providing & fixing following accessories:-
Aluminium handles
Aluminium tower bolts
Door stopper
Door seal
Construction of brick masonary manholes cement mortar 1:4 ( 1 cement: 4 coarse sand) RCC tap slab with 1:2:4 mix with 20 mm nominal size foundation concrete 1:4:8 inside plastering 12 mm thick with cement mortar 1:3 finished with floating coat of neat cement.
Supplying and fixing of following paino type switch socket on the existing switch board:-
5/6 Ampere switch
3 pin 5/6 Amp socket outlet
15/16 Ampere Switch
6 pin 15/16 Ampere socket outlet
Fan regulator
Batton holder
5 Amp ceiling rose
1x20 LED tube light
9 watt LED bulb
Supplying and drawing of following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed PVC conduit
3x1.5 sqmm
3x2.5 sqmm
3x4 sqmm
Supplying and fixing of 5x32 ampere rating single pole MCB suitable for inductive load in the existing MCB DB box complete with connection testing.
Supplying & fixing of 6 way TPN double door 3 pole and neutral sheet steel MCB distribution board 415 volt on surface/recessed complete with tinned copper bus bar/neutral bus bar earth bar, din bar including connection testing etc as reqd.
Supplying and fixing of following double pole SPN on the existing DB box including connection testing
40 Amp SPN
63 Amp SPN
M/S CHAMAN LAL
BADRI NATH CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .