Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Mar 2021, 6:00 pmClosed
CWE Amritsar
CWE Amritsar Old Cantt Amritsar
REPAIR REPLACEMENT OF HT OH LINE UG CABLE AND CONNECTED ITEMS OF EXTERNAL ELECTRIC SUPPLY AT OLD CANTT AND GG FORT AREA UNDER GE AMRITSAR
2020_MES_363752_1
CWE/ASR-39/2020-21
Open Tender
Civil Works
Item Rate
180 days
Amritsar
Class D /E
Category bii
8 documents required · 8 mandatory
₹500
GE Amritsar
₹80,000
4 May 2021
13 Feb 2021
20 Mar 2021
13 Feb 2021
18 Mar 2021
1 Mar 2021
Amount
Supply and errecting in true vertical position steel tubular poles 11 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-55 with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion with two coats of aluminium paint over a coat of red oxide primer, including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles including necessary form work where required and fair finish to the exposed surfaces all as specified & directed by Engr-in-charge.
All as per srl item No 2 here-in-before but PCC 1:3:6 type C-2 as in foundation of stays and coping of poles.
M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Supply, laying, jointing and testing HT XLPE cable cross section area 95 Sqmm, 3 core, 11000 V screened, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with alluminium conductor 11 KV pressure earthed system conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985 laid in pipes /ducts/ trenches,under floor and roads or fixed to wall etc incl taking out old unsv cable any type complete all as specified and directed
Supply, laying, jointing and testing HT XLPE cable cross section area 185 Sqmm, 3 core, 11000 V screened, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with alluminium conductor 11 KV pressure earthed system conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985 laid in pipes /ducts/ trenches,under floor and roads or fixed to wall etc incl taking out old unsv cable any type complete all as specified and directed.
M&L indoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 50 to 95 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L indoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 120 to 185 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L indoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 240 to 300 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 50 to 95 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L outdoor type cable end termination kit, heat shirnkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 120 to 185 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 240 to 300 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 50 to 95 Sqmm 3 core heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 120 to 185 Sqmm 3 core , heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 240 to 400 Sqmm 3 core , heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
Supply and laying GI steel tubing80mm dia light grade in replacement (IS-1239) with all fittings in trenches/under roads/along pole/wall for protection of Cable/GI wire/ GI strip etc all as specified and directed.( Note : Exc and earth work shall be measured and paid separetely)
Description as per item No 16 above but 100 mm dia
M&L for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip of size 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in SSR Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 20 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 25mm dia light grade up to 7.5m from complete all as specified ,indicated on electrical plate No 5 and as directed incl testing on completion. NOTE: ( i ) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 25mm/40mmdia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
M&L for earthing complete with copper earth electrode of size 20 mm dia, 450 mm long buried directly in ground boring hole (boring hole not less than 25 to 27 meters deep below ground level and boring hole size minimum 125 mm dia) and copper electrode connected to copper wire 8 mm by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as recommended and specified and testing on completion, including provision of earth strip protected by 32mm dia GI light grade protection pipe from ground level to test point , PCC earth pit and RCC cover charcoal, salt and chemical as recommended quantity by Engr-in-Charge etc complete all as specified and directed at site. Note : 1. All T&P required for boring hole and other connected work included in quoted rate and no extra payment made for it. 2. Test result should be less then 1.50 Ohm and testing of earthing will be responsibility of contractor including testing equipment. 3. Copper wire 8 mm and GI light grade of size 32 mm from ground level to test point included in item rate and no extra payment made for it.
M&L for excavation in trenches in soft/loose soil not exceeding 1.5 meters wide and not exceeding 1.5 meter depth for laying of HT cables complete all as specified and as directed.
M&L for excavation in trenches in soft/loose soil not exceeding 1.5 meters wide and exceeding 1.5 meter depth but n. exc 3 mtr in depth . for foundation for LT cables/poles etc complete all as specified and as directed.
M&L for returning filling in trenches including spreading leveling watering and well ramming in layers each not exceeding 25 cm in soft/loose soil complete all as specified
M&L for removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meters above the starting point, complete all as specified.
M&L for Sand cushioning to UG cable 40cm wide 15cm and 10cm thick above and below the cable in trenches/ducts complete all as specified and directed by Engineer-in-Charge punned down the thickness will be taken from measurement.
Supply and laying un-reinforced precast concrete cable cover class HV type I flat of size 300mm x 180mm x 40mm all as specified factory made ISI marked.
Dismantling of existing HT pole any size/type from foundation in necessary earth work including dismantling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed.
Dismantling of cross arms, fabricated from MS structural section of any type and size, duly bolted from existing position and keeping at side for repair/replacement as directed.
M&L danger notice plate of 1.6 mm thick mild steel sheet, vitrous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20 cm complete all as directed at site. Note- The danger notice for 11/66kv will be written in English,Hindi and Punjabi language as directed by Engineer in charge.
Supply and fixing in replacement of HT jumper of existing two/four pole structure of transformer etc using 95 Sqmm single core aluminium cable conductor , including PG clamp nut, bolts, thimbles and washers etc as required at site all as directed by Engr-in-Charge.
S&F HT cable route indicator of Cast iron not less than 100 mm dia fixed through welding angle iron supoort of size 35 mm x 35mmx5mm thick ,50 cm long including two coats of synthetic enamel paint over a coat of red oxide primer planted in a PCC block of size 60 cm x30cm x 10 cm (PCC 1:3:6) , The whole assembly of PCC iron will be planted in ground upto 30 cm complete all as specified and directed.
Supply and fixing in replacement of aluminium lugs of size 50 Sqmm to 95 Sqmm from HT/LT cable incl cutting of worn out aluminium cable terminal lugs from the cable, crimbing of new aluminium cable core and excavation surface after providing redressing of excavated surface fixed to transformer or pannels.
Description as per item No 31 above but of size 120 Sqmm to 150 Sqmm
Description as per item No 31 above but of size 185 Sqmm to 240 Sqmm
Description as per item No 31 above but of size 300 Sqmm to 400 Sqmm
Repair & Servicing of VCB of any capacity including shifting from one place to other place or PCC plateform in old Amritsar cantt area including HT/LT connection complete all as specified and directed at site by Engr-in-Charge. Note : All T&P and machines required for shifting of VCB to be provided by the contractor and rates included in quoted rate of this item and new item on required measured and paid separtely )
Suppy and fixing Closing coil suitable for 630 Amp 11000 Volts VCB as per sample complete all as specified and directed. Make Kirloskar Model M-500
Suppy and fixing Tripping coil suitable for 630 Amp 11000 Volts VCB as per sample and specified and directed.Make Kirloskar Model M-500
Suppy and fixing Spring charging motor with gear assembly supply 230 volts AC suitable for 630 Amp 11000 Volts VCB as per sample complete all as specified and directed. Make Kirloskar Model M-500
Suppy and fixing FRP Vaccum Bottle Support suitable for 630 Amp 11000 Volts VCB as per sample complete all as specified and directed. Make :Kirloskar Model No.M-500
Suppy and fixing Space heater suitable for 630 Amp 11000 Volts VCB as per sample Make :Kirloskar/Crompton Greaves/Seimens
Supply, fixing, connecting and testing in replacement of unservicable volt meters flush type 96x96 mm digital type 11 KV, suitable for 110/240 volt AC supply suitable for showing three phase values with LCD display including cutting/welding work all as directed.
Supply, fixing, connecting and testing in replacement of unservicable Electronic Buzzer flush type 96x96 mm digital type with input voltage of 230 V AC and output noise level of 90-120 db (decibels) suitable for Control and Relay panel and VCB panel as per existing sample complete all as specified and directed .
Supply and fixed LED indicator lamp 12/24 DC or 230 AC all as specified and as directed
Supply, installation, connecting, and testing of 11 KV single phase indoor resin cast CT of ratio 300/150/5-5A suitable for VCB as per existing type and make including taking down old unserviceable CT all as specified and directed. Make : Instrans/CG/Schneider
Supply, installation, connecting, and testing of 11 KV single phase indoor resin cast CT of ratio 100/50/5-5A suitable for VCB as per existing type and make including taking down old unserviceable CT all as specified and directed. Make : Instrans/CG/Schneider
Material & labour stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including FI clamps 50 x 6 mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long, stay bow 400 x14mm, GI steel plate 300x300x6mm, loop insulator of size 90 x 140mm clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate No. 1 of SSR part - I 2009 on Page No 495 compelete all as specified and directed.
Supply and filling silica gel in different capacity of transformers breathers complete all as specified
Supplying, laying, jointing & testing 2.5 Sqmm 4 core PVC insulated, armoured electric cable with flexible stranded copper conductor, 1100 volts grade complete including taking down old unserviceable cable any type and size all as specified and directed.
Supplying, laying, jointing & testing 2.5 Sqmm 2 core PVC insulated, armoured electric cable with flexible stranded copper conductor, 1100 volts grade complete including taking down old unserviceable cable any type and size all as specified and directed.
Material and labour for taking out and relaying existing HT cable of any size / type after repairing defects etc complete all as specified and directed. (Note : Excavation, earth work, sand cushioning and protection cover, joints will be measured and paid for separately under respective items.)
S&F intrupted based plate for 630 Amp VCB trolly as per manufacture including connection complete all as specified and directed.Make Kirloskar Model M-500
S&F Insulator bush for 630 Amp VCB trolly as per manufacture including connection complete all as specified and directed.Make Kirloskar Model M-500
S&F limit switch 1 No 1 NC for 630 Amp VCB trolly as per manufacture including connection complete all as specified and directed.
S&F drive insulator for 630 Amp VCB trolly as per manufacture including connection complete all as specified and directed.
S&F busbar/VCB insulator for 630 Amp VCB trolly as per manufacture including connection complete all as specified and directed.
S&F mechanism part of trolly for 630 Amp VCB trolly as per manufacture including connection complete all as specified and directed.
S&F HT disc type polymer ball and socket type of diameter 100 mm creep age distance 120mm , tensile strength 45 kN , for working pressure 11000 volts complete compatible with existing system all as specified and directed including removing of old insulator of any type or make.
Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator polymer type type switch Triple pole mechanicaly operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 400 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrengement,assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity as per site requirement and as specified by Engr Incharge , complete with DO fuses assembly with channel and one No. operating Rod of 25 mm dia bore grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut,bolt, washers including taking down existing set all as directed by Engineer-in-charge.
M&L for testing of faulty HT cable by using HT high voltage fault locating machine and finding the fault including all T&P as required on site. Note Each job includes finding out the location of one fault in HT feeder
Supply and fixing glyphosate 41% SL Glykol Herbicide to remove vegatation from E/M Installations complete all as specified and directed by Engr-in-Charge
Opening up the top cover of the transformer by taking out the transformer oil in a separate container after disconnecting / taking out the HT/LT side electric connections from both the primary & secondary side of the transformer of any type / description (indoor / outdoor type ) installed on floor/pole for carrying out necessary repair / rewinding to HT/LT side or any other repair as required after shifting the transformer to contractor's work shop including taking out complete core assembly, Magger the winding for identifying the fault/defective winding, seggregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for transformer of capacity 50 to 160 KVA including assembling & testing on completion & installation the same at the site all as specified and directed.Note : (i) Winding of coil and spares required as per repair shall be measured and paid separately under respective item.(ii) The transpotation charges and taking down/taking up of transformer are inclusive in the quoted rates.(iii) The cost for the dehydration of transformer oil if reqd shall be measured & paid separately.(iv) The cost of insulation material such as paper, cotton tape , latheroid sheet , casl sheet etc are inclusive in the quoted rate.
All as per item No 64 here-in-before but capacity 200 to 500 KVA.
Opening up the top cover of the transformer by taking out the transformer oil in a separate container after disconnecting/taking out the HT/LT side electric connections from both the primary & secondary side of the transformer of any type/ description ( indoor/outdoor type ) installed on four pole for carrying out necessary repair/replacement of HT/LT side bushes or any other repair as required for transformer of capacity 50 to 500 KVA including assembling & testing on completion complete all as specified and directed.
Dehydration and filtering the transformer oil with dehydration machine to achieve dielectric strength of the oil to 40 KV at 2.5 mm gap complete all as specified and directed .Note:- Dehydration machine and other necessary equipments required shall be arranged by the contractor and quoted rates shall be inclusive of this aspect.
Supply and filling for topping up transformer oil in the transformer after dehydration with dehydration machine to achiene dielectric strength of oil to 40 KV at 2.5mm gap complete all as specified.
Material & labour for copper winding wire of any size/description suitable for step down power transformer of any capacity, including winding of coils (HT/LT) as per the manufacturers design & specification to obtain rated KVA complete all as specified.
Servicing of 66kV circuit breaker outdoor type including minor repair of parts, greasing, gas recharging etc complete testing all as specified and directed by Engineer-in-charge
Supply and fixing LT side brass stud with nuts. Bolts and washers for trasnformer of capacity 50 to 200 kVA complete all as specified and directed
Supply and fixing LT side brass stud with nuts. Bolts and washers for trasnformer of capacity 200 to 500 kVA complete all as specified and directed
Supply and fixing HT side brass stud with nuts. Bolts and washers for trasnformer of capacity 50 to 200 kVA complete all as specified and directed
Supply and fixing HT side brass stud with nuts. Bolts and washers for trasnformer of capacity 200 to 500 kVA complete all as specified and directed
Suppy and fixing O/C and E/F relay suitable for 630 Amp 11000 Volts VCB as per sample including provision for fixing in existing panel by cutting/welding work all as specified and directed Make :Alstom/Schneider/ L&T (Model No. MC61ANX4000)
Shifting of transformer of capacity 50kVA to 500 kVA from one place to other place on two/four pole/plinth in old Amritsar cantt area/GG fort including removing and refixing of HT/LT connections complete all as specified and directed (All T&P, hydra crane etc required for the job should be provided by contractor, the quoted rate of this item deemed to include )
Material and labour for fixing aluminium strip 40x10mm, including stainless steel bolts, washers, cutting and making hole as per the LT/HT stud of the transformer of rating 50-500kVA complete all as specified and directed by Engineer-in-charge
Raman Electric Trading Co
Bharat Builder
M/S BALWINDER SINGH
UNITED ENGINEERING CORPORATION
kailu construction co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .