| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹23.6 L+₹4.3 L (22.2%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹24.0 L+₹4.7 L (24.4%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹27.9 L+₹8.6 L (44.4%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
| Sl No | Description | Qty | Unit | shyam construction L1 | M/s RCC L4 | Ms Kamal Kant Agarwal L2 | M/S S S CONSTRUCTION L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down ceiling fans/exhaust fans/fresh air fans of any make and type for rectifying the defects including replacement of unserviceable parts to make the fans fully functional testing and reinstalling at same or any other location as directed at site by Engineer-in-charge.
Notes :
(i). The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair etc complete all as directed by Engineer-in-charge.
(ii) Cost of major items such as ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel,greasing, washers, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc complete will be provided without any extra cost and cost of these minor items or works will be deemed to be included in the quoted rates against this item and nothing extra shall be paid on this account.
(iv) The Spare Part item (s) required to be changed/replaced in appliance to make the appliance efficient workable shall of same makes/manufacturers of appliance. | 2,225 | Each Job | 5 ₹11,125 Lowest | 30 ₹66,750 | 20 ₹44,500 | 40 ₹89,000 |
| 2.00 | M&L for spray painting to ceiling fan 1200 mm/1400 mm and applying two coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and as directed. | 1,800 | Each Job | 12 ₹21,600 Lowest | 27 ₹48,600 | 30 ₹54,000 | 40 ₹72,000 |
| 3.00 | M&L for spray painting to exhaust fan and applying two coat of synthetic enamel paint as approved by Engr-in-charge including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and as directed. | 50 | Each Job | 15 ₹750 Lowest | 27 ₹1,350 | 50 ₹2,500 | 40 ₹2,000 |
| 4.00Dismantling of worn out/ burnt out windings of ceiling / exhaust fan and re-winding the motor of ceiling / exhaust fan with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut and testing for original and consumption complete all as specified and directed for following sizes:- | |||||||
| 4.01 | Ceiling fan 1200 mm sweep. | 1,800 | Each Job | 240 ₹4,32,000 | 280 ₹5,04,000 | 250 ₹4,50,000 | 200 ₹3,60,000 Lowest |
| 4.02 | Ceiling fan 1400 mm sweep. | 300 | Each Job | 250 ₹75,000 | 280 ₹84,000 | 275 ₹82,500 | 200 ₹60,000 Lowest |
| 4.03 | Exhaust fan 150 mm sweep | 15 | Each Job | 240 ₹3,600 | 350 ₹5,250 | 275 ₹4,125 | 150 ₹2,250 Lowest |
| 4.04 | Exhaust fan 200/230/250 mm sweep. | 50 | Each Job | 280 ₹14,000 | 340 ₹17,000 | 300 ₹15,000 | 150 ₹7,500 Lowest |
| 4.05 | Exhaust fan 300 mm sweep. | 50 | Each Job | 290 ₹14,500 | 350 ₹17,500 | 335 ₹16,750 | 200 ₹10,000 Lowest |
| 4.06 | Exhaust fan 375 mm sweep. | 2 | Each Job | 500 ₹1,000 | 420 ₹840 | 420 ₹840 | 230 ₹460 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 Jul 2025, 6:00 pmClosed
GARRISON ENGINEER EAST MATHURA
GE EAST MATHURA
REPAIR/MAINT OF CEILING FANS, EXHUST FANS, FRESH AIR FANS AT ZONE A,B AND C AND REPAIR/ MAINT OF INTERNAL ELECTRIFICATION AND OTHER E/M RELATED MAINTENANCE SERVICES AT OTM ACCN, JCO/ORS MD ACCN, CENTRAL INSTITUTES AND MH IN THE UNDER GE (E) MATHURA
2025_MES_718285_1
1501/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
As per NIT
7 documents required · 7 mandatory
₹500
GE (East) Mathura
₹90,000
Yes
24 Sept 2025
3 Jul 2025
2 Aug 2025
3 Jul 2025
31 Jul 2025
17 Jul 2025
Amount
Taking down ceiling fans/exhaust fans/fresh air fans of any make and type for rectifying the defects including replacement of unserviceable parts to make the fans fully functional testing and reinstalling at same or any other location as directed at site by Engineer-in-charge. Notes : (i). The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair etc complete all as directed by Engineer-in-charge. (ii) Cost of major items such as ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel,greasing, washers, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc complete will be provided without any extra cost and cost of these minor items or works will be deemed to be included in the quoted rates against this item and nothing extra shall be paid on this account. (iv) The Spare Part item (s) required to be changed/replaced in appliance to make the appliance efficient workable shall of same makes/manufacturers of appliance.
M&L for spray painting to ceiling fan 1200 mm/1400 mm and applying two coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and as directed.
M&L for spray painting to exhaust fan and applying two coat of synthetic enamel paint as approved by Engr-in-charge including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and as directed.
Dismantling of worn out/ burnt out windings of ceiling / exhaust fan and re-winding the motor of ceiling / exhaust fan with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut and testing for original and consumption complete all as specified and directed for following sizes:-
Ceiling fan 1200 mm sweep.
Ceiling fan 1400 mm sweep.
Exhaust fan 150 mm sweep
Exhaust fan 200/230/250 mm sweep.
Exhaust fan 300 mm sweep.
Exhaust fan 375 mm sweep.
Exhaust fan 450 mm sweep.
Supply only Capacitors 2.5 MFD suitable for all types of fans complete all as specified and as directed.
Supply only Capacitors 4.0 MFD suitable for all types of fans complete all as specified and as directed.
Supply only SKF 6201 ball bearing suitable for ceiling fan/ exhaust fan/fresh air fan of any type as required including proper alignment of shaft and testing complete all as specified and as directed.
Supply only Bush made out of Gun metal suitable for ceiling fan/exhaust fan as required at site complete all as specified and as directed.
Supply only Shaft of approved quality as per existing for ceiling fan/ exhaust fan/fresh air fan any make as required at site complete all as specified and as directed.
Supply only Canopy (set of two) suitable for ceiling fans of any make, type and size complete all as directed.
Supply only Down rod MS grade 15 mm bore of length upto 75 cm size for ceiling fans of any type and size including cutting, drilling holes, making thread and painting complete all as specified and as directed.
Supply only Exhaust fan blade of type and make as existing or as directed at site complete all as specified and as directed.
Supply only Ceiling fan blade of any type and make as existing or as directed at site of following sizes:-
1200 mm sweep.
1400 mm sweep.
Supply only MS louvers with nuts, bolts and washers suitable for exhaust fan upto 350 mm sweep of same type and make / model as existing complete all as specified and as directed.
All as per Srl Item No 14.00 here-in-before above but for 450 mm Sweep exhaust fan.
Supply only Suitable frames of 300/375/450 mm sweep exhaust fan of any description/make/model complete all as specified and as directed at site.
Supply only Exhaust fan motor 18'' copper winding, 1450 rpm, 230V , 50 Hz ,with fixing accessories to mount on existing frame complete all as specified and as directed.
Supply only Exhaust fan motor 12'' copper winding, 230V , 50 Hz ,with fixing accessories for mount on existing frame complete all as specified and as directed.
Supply only Exhaust fan motor suitable for 8'' to 10'' PVC ventilator/ fresh air fan, copper winding, 230V, 50 Hz , with fixing accessories to mount on existing frame complete all as specified and as directed.
S&F in repair wall mounted fan motor, copper winding, 230V, 50 Hz, with fixing accessories to mount on frame complete all as directed including taking down old unserviceable fan motor from exitsting fan complete all as specified and as directed.
S&F in repair wall mounted fan blade of any type and make as existing complete all as specified and as directed.
S&F in repair of fresh air/ventilator fan made of sturdy engineering plastic with built in louvers, AC, 230Volt single phase, 50 Hz, complete all as specified and directed of following sizes :-
150mm Sweep
200mm Sweep
250mm Sweep
300mm Sweep
M & L for 3 core copper conductor 0.75 sqmm conductor area, PVC insulated, PVC round sheathed multicore, 1100 volt, including with use of PVC conduit pipe / Casing -Caping as per site requirement including taking down old u/s wire complete all as specified and as directed.
M & L for 3 core copper conductor 2.5 sqmm conductor area, PVC insulated, PVC round sheathed multicore, 1100 volt, including with use of PVC conduit pipe / Casing -Caping as per site requirement including taking down old u/s wire complete all as specified and as directed.
S&F in repair fan Regulator electronic step type, piano flush type as per existing type (switch or socket type) on the existing phenolic laminated sheet complete all as specified and as directed.
S&F in repair step type electronic modular type fan regulator 2M on the existing plate complete all as specified and as directed.
S&F in repair MCB distribution board, SPN 2 Way, single door, sheet steel, phosphatised, powder painted, 240 V, complete all as specified.
S&F in repair SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts with all connection complete all as specified and as directed.
S&F in repair LED extruded aluminium decorative & cylindrical shape bollard light 10 W with integrated driver, IP 65, with uniform light distribution complete all as specified and as directed.
S&F in repair MCB Single pole and neutral 240 volts, C series of capacity 6-32 Amps of breaking capacity 10 KA all as directed.
S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder coated with Copper bus-bar 200Amp, two neutral link, earth bar and din rail, blanking plates, cable ties for cable management, 440 V, 4 way including fitting with following MCCB & MCBs with connection complete all as specified and as directed. (a) MCCB 125 Amps, 4 Pole, 16 KA - 01 No Note : - (i) MCB & MCB /MCCB DBs shall be of same make. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items.
S&F wireless Door Bell for office with LED light 300 Meter 1000 Feet Operating Range 32 Ringtones 5 levels Volume, 1 Receiver and 2 Push Button IP 44 Waterproof, White complete with connection all as specified & directed.
S&F LED Driver/Adapter suitable for 36 Watt (2x2 Panel light) complete all as per specified and as directed.
Taking down carefully copper/aluminum copper point wiring (light, fan, socket or power, bell etc.) complete including fixtures & fittings such as ceiling rose, socket, Pendant, regulator, sockets, light fitting etc and removing the material from site and making good the disturbed surfaces of walls, ceiling etc complete all as directed.
Taking down carefully old unserviceable submain wiring of any type complete all as specified and as directed.
Taking down old unserviceable existing SP/SPN/TPN DB/ enclousers any size and type/any descriptions MCB and making good disturbed surface of walls to match the surrounding surface complete all as specified and as directed.
M & L for point wiring with 1.5 Sqmm (nominal area) PVC single core PVC Sheathed (FRLS) copper conductor cable, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less than 20mm dia) and its all accessories complete concealed in wall including cutting & chases and making good all to the disturbed surfaces to match the existing surface, land providing modular flush metal boxes including base plate and cover plate for mounting modular switches, sockets, regulators etc including earth wire of PVC single core sheathed (FRLS) copper conductor cable of 1.5 Sqmm size in green colour complete all as specified in SSR Part-I & II & directed by the Engineer-in-Charge for the followings:-
One light/fan point controlled by one way modular switch 5 amp complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on same board complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on independent board complete all as specified and as directed.
One bell point controlled by one push button complete all as specified and as directed.
One light point controlled by 2 way switch complete all as specified and as directed.
All as per item No. 39.00 here-in-above but for 3/5 pin 16 Amps socket outlet independent with 4 Sqmm PVC Sheathed (FRLS) copper conductor cable complete all as specified and as directed .
S&F Modular switch single pole one-way, 6 Amps 1 Module complete all as specified and as directed.
S&F bell push single pole one-way, 6 Amps 1 Module with indicator complete all as specified and as directed.
S&F Modular switch single pole one-way, 16 Amps 1 Module complete all as specified and as directed.
S&F Modular fan Regulator electronic step type 1 Module complete all as specified and as directed.
S&F modular socket 2-in-1, 5 Pins, 6 Amps combined 2 module complete all as specified and as directed.
S&F modular socket 2-in-1, 3 and 5 Pins, 6/16 Amps combined 2 module complete all as specified and as directed.
S&F Modular switch single pole two-way, 6 Amps 1 Module complete all as specified and as directed.
S&F in repair switch piano type, SP, one way, flush type 5 Amps complete all as specified and as directed.
S&F in repair socket out let 2-in-1 flush type 5 pin 5 Amp complete all as specified and as directed.
S&F in repair socket out let 2-in-1 flush type 3 pin 5 & 15 Amp complete all as specified and as directed.
S&F in repair switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F in repair bell push siwtch piano flush type, SP, one way, 5 Amps complete all as specified and as directed.
S&F in repair ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
S&F in repair lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair mini MCB enclosure including DP 16 Amp 'C' curve type complete all as specified and as directed
S&F in repair Bell Ding dong type, 230 Volts including connections complete all as specified and as directed.
S&F Sub main wiring with two runs single core 4 Sqmm PVC insulated Sheathed (FRLS) cable with stranderd copper conductor, 1100 votls grade drawn through and including concealed PVC conduit 20 mm dia and all its accesories concealed in wall/roof including cutting & chases and making good the disturbed surface, including PVC insulated 4 sqmm Sheathed stranded (FRLS) copper conductor cable for earth wire complete all as specified and as directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire & 20mm PVC Conduit shall be measured as one RM.
All as per item No 56 but for 6 Sqmm.
All as per item No 56 but for 10 Sqmm.
S&F in repair indoor decorative ultra slim surface/Wall mounted LED batten tube light fitting with 1x 20 watt LED Tube including extrusion aluminium housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, neutral white colour complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light fitting 1X9 watt LED Tube fitting (size within 600x25x40 mm) suitable for mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K,>100Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair surface mounted, LED Bulk Head fitting of IP 66 protection including 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and as directed.
S&F LED 9W suitable for B-22 type holder, complete all as specified and as directed.
S&F LED 7W suitable for E-14 type holder, complete all as specified and as directed.
S&F in repair 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connections complete all as specified and as directed.
S&F in repair recess type, 36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair LED decorative bed side light fitting 3 watt flexible alarm complete with all accessories, on/off inbuilt switch and including connection complete all as specified and directed.
S&F in repair indoor wall mounted fitting, brushed nickel finish fixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts (02 Nos)complete all as specified and as directed.
S&F in repair Post top lantern LED type 30 Watt 230V AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in repair LED Round/square recess mounted slim downlighter 15/18 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete all as specified and as directed.
S&F in repair building security light bracket made out of 40mm dia medium grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including applying two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
S&F in repair MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
All as per item No 69 but for SPN 8 way.
All as per item No 69 but for SPN 4 way.
S&F in repair MCB SPN 40-63Amps, 'C' series , breaking capacity10KA, 240V complete all as specified and as directed.
S&F in repair MCB SPN 16-32 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F in repair MCB SP 6-32 Amps, 'C' series , breaking capacity 10KA, 240V complete all as specified and as directed.
S&F in repair metal clad SPN plug to 20 Amp for fixing on AC box complete all as specified and as directed.
S&F Modular MCB DP 16 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 1/2 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 3/4 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and as directed.
All as per item No 82 but for 250mm sweep.
S&F in repair Plastic Surface mounting box 6/8 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and directed.
S&F in repair 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch / socket and connection complete all as specified and as directed. Note :- Switch/socket/regulator etc required to be replaced shall be measured & Paid separately under relevent item of BOQ.
S&F in repair 3 mm thick laminated mica sheet top cover suitable for switch board 8 way to 12 way including removing & re-fixing of existing switch / socket and connection complete all as specified and as directed. Note :- Switch/socket/regulator etc required to be replaced shall be measured & Paid separately under relevent item of BOQ.
S&F in repair Modular metal flush box 1/2 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 3 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 4 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 6 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 8 Module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 1/2 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 3 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 4 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 6 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 8 module complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated, Sheathed, (FRLS) 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces ( making good all to the disturbed surfaces as per existing) including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing having provision for gang box/ 2mm thick MS terminal box as per site for fixing switches, sockets, fan regulators etc complete all as specified and as directed for the following:-
One light point/fan point/bell point controlled by one switch.
One 3 pin 5 Amps socket point controlled by one way switch on same board.
One 3 pin 5 Amps socket point controlled by one switch on independent board.
All as per item No. 95.00 here-in-before but with 4.0 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
S&F switch piano flush type 5 Amps, SP, one way complete all as specified and as directed.
S&F socket out let flush type 2-in-1, 5 pin 5 Amp complete all as specified and as directed.
S&F socket out let flush type 2-in-1, 3 pin 5/15 Amp complete all as specified and as directed
S&F switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F in repair Modular switch single pole one-way, 6 Amps 1 Module complete all as specified and as directed.
S&F in repair Modular switch single pole one-way, 16 Amps 1 Module complete all as specified and as directed.
S&F in repair Modular fan Regulator electronic step type 1 Module complete all as specified and as directed.
S&F in repair modular socket 2-in-1, 5 Pins, 6 Amps combined 2 module complete all as specified and as directed.
S&F in repair modular socket 2-in-1, 3 and 5 Pins, 6/16 Amps combined 2 module complete all as specified and as directed.
S&F SP enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). Note :- Old unserviceable item shall be deposited to E/M store yard.
All as per item No 105 but for 1400 mm sweep.
S&F in repair wall fans 300mm sweep complete with blade.
S&F in repair exhaust fan, steel body AC single phase 230V of size 300mm sweep with blades, and frame and louvers.
All as per item No 108 but for 250 mm sweep
S&F powder coated CRCA steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 100 Amps rated copper bus bar, type complete all as specified and as directed.
S&F in repair MCB TPN 40 to 100 Amps, 'C' series , breaking capacity 10KA, 415V complete all as specified and as directed.
S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder coated with bus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way complete all as specified including fitting suitable MCBs with connections complete all as specified and as directed. Note : MCB /MCCB, DBs shall be of same make and measured and paid seperately under respective items of Sch A. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items.
S&F in repair MCCB 4 pole 415 Volts thermal magnetic based adjustable type 250 Amp, with breaking capacity 36kA Complete all as spccified and as directed.
S&F in repair MCCB 4 pole 415 Volts thermal magnetic based adjustable type 160 Amp, with breaking capacity 25kA Complete all as spccified and as directed.
S&F in repair MCCB 4 pole 415 Volts thermal magnetic based adjustable type 125 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
S&F in repair MCCB 4 pole 415 Volts thermal magnetic based adjustable type 100 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
S&F garden light fitting , made of aluminium die cast, decorative type with 12 watt LED bulb base B-22 fixed on pole with all electrical connection complete. Make: Jainsons Lights, model : 50089 medium.
S&F garden light fitting , made of aluminium die cast, decorative type height 1215 mm, base 260mm including PCC foundation (size 500mm X 500mm height 600 mm) with provision of passing of cable for light complete. Make: Jainsons Lights, model : 50066-2L.
S&F in repair indoor wall mounted fitting, brushed nickel finish fixture, mild steel with glass finish with opal glass diffuser, with LED retrofit bulb of capacity 09 watts all as directed at site. Make:-Havells Cat Part No. FLORETINE WL 1LS B22 SS or equivalent make in Crompton/ Philips C&S.
M&L Cement concrete in foundation, filling & mass concrete for electric pole & mass concrete type C2 1:3:6 using 40mm graded aggregate (for air termination rod pipe).
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables etc and getting out complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each, after filing back in trenches after cables have been laid and tested complete all as specified and as directed.
Supply, laying, jointing and testing of 10sqmm x 2 core XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches/duct/fixing on walls/poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole/Main Panel Box and testing complete all as specified and as directed of following sizes :- Note:- Quoted rate shall deemed be inclusive of cost of HDPE pipe.
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 10mm dia bar both way @ 100mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete all as specified and as directed.
S&F cable with copper conductor PVC round sheathed (flexible) industrial cable 2.5 sqmm, 3 core.
S&F fan regulator piano flush type, electronic step type complete all as specified.
S&F exhaust fan made of sturdy engineering plastic complete withlouvers shutter, Voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300m complete all as specified.
All as per item No 128 but for 250mm.
M&L for submain wiring with Two runs of single core 6 Sqmm for main wire and one run of single core 6 Sqmm as earth wire of stranded copper conductor FRLS PVC insulated unsheathed cables conforming to IS :694 drawn through existing conduit complete all as specified and as directed.
S&F in repair step type electronic modular type fan regulator 1M on the existing plate complete all as specified and as directed.
S&F ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified.
Ms Kamal Kant Agarwal (BID ID -3377347)
M/S S S CONSTRUCTION (BID ID -3370354)
M/s RCC (BID ID -3370215)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .